Styringsparametre

1. Dagens støj situation

2. Støj i plan vist i workshop 2

3. Støj i foreslået helhedsplan

Komfort Vi har brugt komfort som et styringsparameter i udviklingen af prosjektet. Følgende 4 komfort parametre har vi løbende testet og brugt til at finjustere planen. • Støj mitigering Seite 7 • Dagslysfaktor • Timer sol for boliger • Udsigt

3. Comfort

Based on this analysis the following numbers can be extracted: 77.6% of the residential facades have access to the minimum recommendation of 1.5 sun hours of the European daylight norm EN Dagslysfaktor, timer sol for boliger og udsigt er 17037 for the criteria a daily sunlight exposure (on a day between February 1 and March 21). It beregnet i henhold til European Daylight Norm should be noted that an apartment may have openings on two facades so that even some facades EN 17037 that do not fulfill the 1.5 sun hours still offer a good quality of living. Finally, the methodology

developed for this competition allows to quantify different daylight factors Over 50% of the residential façade even achieved 4 hours of sun hours,comfort which qualify them foras the given in the European Daylight Norm EN 17037, such as the access to ‘high’ level of recommendation. sun hours for residential buildings, the daylight availability and the distance of view. These View-out tools allow to assess which qualities can be achieved at different locations of the masterplan. distances

Example: visualization of the sun hours for the north east part of the site for march 21

Støjanalyse er udarbejdet i dialog med Buro Happold

Daylight factor on the façade

Based on this analysis the follow have access to the minimum reco 17037 for the criteria a daily sun should be noted that an apartmen that do not fulfill the 1.5 sun hours

Over 50% of the residential façad ‘high’ level of recommendation. The daylight factor on the façade allows to determine which openings and which glazing quality are more suitable depending where they are located in order to ensure a good daylight quality in the spaces or to use this info for the right space placement. Dagslysfaktor

Timer sol for boliger

Kapitel 2 | Grøn og urban balance

4. Green spaces and impermeability coefficient

TRANSSOLAR Energietechnik GmbH Curiestraße 2 70563 Stuttgart

View-out distances

Udsigt

Daylight factor 16 on the façade