UNIT DEVELOPMENT - WORKING DRAWINGS

Page 1

13 PARK AVENUE, PRESTON, 3072

LIST OF CONTENTS

PROPOSED TWO STOREY UNITS

A02 - SITE PLAN

A01 - GENERAL NOTES A03 - GROUND FLOOR PLAN A04 - FIRST FLOOR PLAN A05 - ELEVATIONS A06 - ELEVATIONS A07 - SECTION

GENERAL NOTES GN01- DO NOT SCALE PLANS, USE WRITTEN DIMENSIONS ONLY. GN02- THE OWNER, BUILDER, SUBCONTRACTOR SHALL VERIFY ALL DIMENSIONS, LEVELS, SETBACKS AND SPECIFICATIONS PRIOR TO COMMENCING ANY WORKS OR ORDERING MATERIALS AND SHALL BE RESPONSIBLE FOR ENSURING THAT ALL BUILDING WORKS CONFORM TO THE BUILDING CODE OF AUSTRALIA, AS CODES (CURRENT EDITIONS), BUILDING REGULATIONS, LOCAL BY-LAWS AND TOWN PLANNING REQUIREMENTS. GN03- ALL WORKS SHALL COMPLY WITH BUT NOT LIMITED TO THE FOLLOWING AUSTRALIAN STANDARDS: AS1288 - GLASS IN BUILDINGS - SELECTION AND INSTALLATION. AS1562 - DESIGN AND INSTALLATION OF SHEET ROOF AND WALL CLADDING. AS1684 - RESIDENTIAL TIMBER FRAMED CONSTRUCTION. AS1860 - INSTALLATION AND PARTICLE BOARD FLOORING. AS2047 - INSTALLATION AND SELECTION OF WINDOWS. AS2049 - ROOF TILES. AS2050 - FIXING OF ROOF TILES. AS2870 - RESIDENTIAL SLABS AND FOOTINGS. AS2904 - DAMP PROOF COURSES AND FLASHINGS. AS3500 - PLUMBING AND DRAINAGE. AS3600 - CONCRETE STRUCTURES AS3660 - PROTECTION OF BUILDINGS FROM SUBTERRANEAN TERMITES AS3700 - MASONRY IN BUILDINGS. AS3740 - WATERPROOFING OF WET AREAS IN RESIDENTIAL BUILDINGS. AS3959 - CONSTRUCTION IN A BUSHFIRE PRONE AREA. AS3786 - SMOKE ALARMS. AS4055 - WIND LOADINGS FOR HOUSING. AS 4100 - STEEL STRUCTURES.

GN18- STUMPS EXCEEDING 1200MM ABOVE GROUND TO BE BRACED CONCRETE STUMPS -100MM SQ UP TO 1400MM LONG (1NO. WIRE) -100MM SQ 1400MM TO 1800MM LONG (2 NO. HD. WIRES) -125MM SQ 1800MM TO 3000MM LONG (2 NO. HD. WIRES) GN19- THE BUILDER SHALL TAKE ALL STEPS NECESSARY TO ENSURE STABILITY OF NEW AND EXISTING STRUCTURES DURING ALL WORKS. GN20- THE BUILDING SHALL ENSURE FOR THE GENERAL WATER TIGHTNESS OF ALL NEW AND EXISTING WORKS. GN21 SMOKE ALARMS TO BE PROVIDED AND INSTALLED IN ACCORDANCE WITH AS3786. NEW DWELLINGS AND ADDITIONS WITH SLEEPING ACCOMMODATION TO BE HARD WIRED WITH BATTERY BACK UP. GN22- WHERE BUILDING IS WITHIN A DESIGNATED BUSH FIRE PRONE AREA COMPLIANCE WITH AS3959 - IS REQUIRED TO A LEVEL OF ATTACK AS CONFIRMED BY THE RELEVANT BUILDING SURVEYOR. GN23- W/C DOORS TO TOILET PANS LOCATED WITHIN 1.2M OF THE DOOR JAMB LIFT OFF HINGES MUST BE FITTING. OTHERWISE THE DOOR MUST SWING OUTWARDS. GN24- TERMITE CERTIFICATE (WHERE REQUIRED) TO BE INSTALLED INSIDE METER BOX PRIOR TO OCCUPANCY PERMIT OR CERTIFICATE OF FINAL INSPECTION ISSUE. GN25- THESE NOTES ARE NEITHER EXHAUSTIVE NOR A SUBSTITUTE FOR REGULATIONS, STATUTORY REQUIREMENTS, BUILDING PRACTICE OR CONTRACTUAL OBLIGATIONS AND UNLESS EXPRESSLY STATED OTHERWISE, ARE PROVIDED ONLY AS GUIDELINES. NO RESPONSIBILITY IS ACCEPTED FOR THEIR USE.

GN04- THESE PLANS SHALL BE READ IN CONJUNCTION WITH ANY STRUCTURAL OR CIVIL ENGINEERING COMPUTATIONS AND DRAWINGS. GN05- WHERE REQUIRED TREAT AREA BENEATH FLOOR AGAINST TERMITE INFESTATION IN ACCORDANCE WITH RELEVANT STANDARD. CONTACT THE RELEVANT MUNICIPAL COUNCIL TO DETERMINE IF THE IS MANDATORY.

GN26- DESIGN GUST WIND SPEED/WIND CLASSIFICATION BUILDING TIE-DOWNS TO BE PROVIDED IN ACCORDANCE WITH AS1684-2006 FOR AN ASSUMED DESIGN GUST WIND SPEED/WIND CLASSIFICATION OF -M/S (SUBJECT TO CONFIRMATION ON SITE BY RELEVANT BUILDING SURVEYOR AT FIRST INSPECTION) REFER TO AS1684 FOR CONSTRUCTION REQUIREMENTS

GN06- SAFETY GLASS TO BE USED IN THE FOLLOWING CASES: I) ALL ROOMS - WITHIN 500MM VERTICAL OF THE FLOOR II) BATHROOMS - WITHIN 2000MM OF THE FLOOR III) LAUNDRY - WITHIN 1200MM VERTICAL FROM FLOOR AND/OR WITHIN 300MM HORIZONTAL FROM ALL DOORS. IV) DOORWAY - WITHIN 300MM HORIZONTAL FROM DOORS. SHOWER SCREENS SHALL BE GRADE A SAFETY GLASS.

GN27- THESE DRAWINGS SHALL BE READ IN CONJUNCTION WITH THE WRITTEN SPECIFICATIONS, ALL CONSULTANTS DRAWINGS AND SPECIFICATIONS AND ANY DISCREPANCIES SHALL BE REFERRED TO NEW DIMENSION DRAFTING.

GN07- WINDOW SIZES ARE NOMINAL ONLY, ACTUAL SIZE WILL VARY ACCORDING TO MANUFACTURER. WINDOWS TO BE FLASHED ALL AROUND.

GN30- ALL DIMENSIONS ARE IN METRES AND/OR MILLIMETRES.

GN08- STORM WATER SHALL BE TAKEN TO LEGAL POINT OF DISCHARGE AS ADVISED BE THE MUNICIPAL DRAINAGE ENGINEER. CONTACT THE COUNCIL IF UNSURE OF POINT OF DISCHARGE.

GN12- PROVIDE WALL TIES TO BRICKWORK AT MAXIMUM 600MM CRS IN EACH DIRECTION AND WITHIN 300MM OR ARTICULATION JOINTS.

GN31- STORMWATER 100MM DIAMETER (MIN) OR AS PER ENGINEERS DESIGN CLASS 6 UPVC STORMWATER LINE LAID TO A MINIMUM GRADE OF 1:100 AND CONNECTED TO THE LEGAL POINT OF STORMWATER DISCHARGE PROVIDE INSPECTION OF OPENINGS TO 9000MM C/C AND AT EACH CHANGE OF DIRECTION THE COVER TO UNDERGROUND STORMWATER DRAINS SHALL NOT BE LESS THAN: - 100MM UNDER SOIL. - 50MM UNDER PAVED OR CONCRETE AREAS. - 100MM UNDER UNREINFORCED CONCRETE OR PAVED DRIVEWAYS. - 75 MM UNDER REINFORCED CONCRETE DRIVEWAYS. DRAINAGE NOTES GN32-GN38 GN32- ALL DRAINAGE AND SEWERAGE PIPES ADJACENT TO BUILDING TO BE SETBACK AT A DEPTH THAT WILL NOT AFFECT ANGLE OF REPOSE (45 DEGREES) TO FOUNDING DEPTH.

GN13- ALL WET AREAS TO COMPLY WITH AS3740. WALL FINISHES SHALL BE IMPERVIOUS TO A HEIGHT OF 1800MM ABOVE FLOOR LEVEL TO SHOWER ENCLOSURES AND 300MM ABOVE BATHS, BASINS, SINKS AND TROUGHS IF WITHIN 75MM OF THE WALL REFER TO CODE FOR ALL REQUIREMENTS.

GN33- SERVICE PIPES AND DRAINAGE PIPE JOINTS TO BE ARTICULATED AT SLAB AND FOOTINGS - WALL PENETRATIONS. BACK FILL TO TRENCHES SHALL BE FULLY COMPACTED.

GN14- SUBFLOOR VENTS ARE TO PROVIDE A RATE OF 7500MM SQ CLEAR VENTILATION PER 1000MM RUN OF EXTERNAL WALL AND 2200MM SQ CLEAR VENTILATION PER 1000MM RUN OF INTERNAL DWARF WALLS (LOCATED BELOW BEARER).

GN34- WHERE SEWERAGE AND WATER PIPES PASS 'THRU' SLAB AND FOOTINGS, PROVIDE SLEEVOR LAGGING AROUND PIPES TO ALLOW RELATIVE MOVEMENT 25MM MINIMUM ALL AROUND.

GN15- PROVIDE CLEARANCE FROM UNDERSIDE OF BEARERS TO FINISHED GROUND LEVEL OF 150MM FOR FLOOR WITH STRIP FLOORING OR 200MM FOR FLOORS WITH PARTICLEBOARD FLOORING AND 400MM IN A TERMITE DECLARED AREA.

GN35- GRADING AND SITE DRAINAGE - THE AREA WITHIN 2000MM OF BUILDING LINE SHALL BE GRADED SO THAT WATER WILL NOT POND AGAINST BUILDING.

GN16- DWELLING ADDITIONS PROVIDE THERMAL INSULATION IN ACCORDANCE WITH NCC ENERGY EFFICIENCY REQUIREMENTS NEW DWELLINGS, TO COMPLY WITH 5 STAR ENERGY RATING REPORT (H.E.R.S.).

GN36- GRADE SHALL BE 50MM WITHIN FIRST METER ON SEVERAL SLOPING SITES ADOPT AG DRAINS ADJACENT TO FOOTINGS WHERE THE GROUND FALLS TOWARDS THE BUILDING.

GN17- STAIR REQUIREMENTS RISERS - 190MM MAXIMUM - 115MM MINIMUM. GOING - 355MM MAXIMUM - 240MM MINIMUM. (DOMESTIC ONLY) RISERS AND TREADS TO BE CONSTANT IN SIZE THROUGHOUT FLIGHT. PROVIDE NON-SLIP FINISH OR SUITABLE NON-SKID STRIP NEAR EDGE OF NOSINGS AND LANDINGS. MAXIMUM GAP TO OPEN TREAD NOT TO EXCEED 125MM FOR WIRE BALUSTRADE SEE NCC VOLUME 2 REQUIREMENTS.

GN37- STORMWATER DRAINAGE DISCHARGE POINT - TO KERB AND CHANNEL LOCATION TO BE DETERMINED ON SITE BY BUILDER, OWNER AND PLUMBER WITH AID OF COUNCIL RECORDS.

GN09- SEWER OR SEPTIC SYSTEM SHALL BE IN ACCORDANCE WITH THE RELEVANT AUTHORITIES REQUIREMENTS GN10- FOOTINGS NOT TO ENCROACH TITLE BOUNDARIES AND EASEMENT LINES. OWNER AND BUILDING TO ENSURE THIS DOES NOT OCCUR. GN11- FOR BUILDINGS IN CLOSE PROXIMITY TO THE BEACH, ENSURE THE ALL STEEL WORK, BRICK CAVITY TIES AND STEEL LINTELS, ETC THAT ARE IMBEDDED OR FIXED INTO MASONRY BE PROTECTED IN ACCORDANCE WITH AS3700 HOT DIPPED GALVANISED.

GSEducationalVersion

GN28- THE CONTRACTOR SHALL CHECK AND VERIFY ALL DIMENSIONS AND LEVELS ON SITE PRIOR TO COMMENCEMENT OF ANY WORK. GN29- WRITTEN DIMENSIONS SHALL TAKE PREFERENCE OVER SCALING AND LARGE DIMENSIONS SHALL TAKE PREFERENCE OVER SMALL ONES.

GN38- ADOPT SEWER GRADE WHEN SUSPENDED UNDER TIMBER FLOOR CLIPPED TO JOIST WITH MINIMUM GRADE.

PROJECT NAME:

CLIENT NAME:

DRAWN BY:

SCALE:

UNIT DEVELOPMENT - WORKING DRAWINGS

MR & MRS AMANDRO

NAOMI GRAHAM

DRAWING NAME:

CLIENT ADDRESS:

DATE:

DRWG NO:

GENERAL NOTES

13 PARK AVENUE, PRESTON, 3072

27/07/2017

A01

NG

Building

Design and Drafting


DISTANCE TO NEAREST CORNER 100.74m

NO.15 DOUBLE STOREY BRICK UNITS

NO.15 SINGLE STOREY BRICK UNITS

D P

1460

D

2200

1216

P

G

D

8°↑

12°↑

12°↑

12°↑

NO.13 PROPOSED DOUBLE STOREY BRICK AND CEMENT SHEET CLAD UNIT/ DWELLING. D P

9385

8°↓

5°↓

5°↓

8°↓

G

8°↑

WM

POS

9200

D P

6000

D P

D P

2255

3600

D P

EXPOSED AGGREGATE DRIVEWAY.

8°↓

4600

5825

GARAGE

8°↓

D P

D P

D P

G

13.72 (5°53'50")

D P

D P

13.72 (5°53'50")

3°→

GARAGE

NO.13 PROPOSED DOUBLE STOREY BRICK AND TIMBER CLAD UNIT/DWELLING.

P

3°←

D P

D P

3221

D

1700

D P

G

POS

PARK AVENUE

50.60 (275°55'50")

D P

2200

POS

1500

50.60 (275°55'50")

POS

BUILDING UNDER CONSTRUCTION DOUBLE STOREY TOWNHOUSES.

POS

NO.11 SINGLE STOREY WEATHERBOARD DWELLING

8600

SITE AREA: 694.39m² SITE COVERAGE: 43.60% PERMEABILITY: 189.83m²

LEGEND STORMWATER PIPES D P

NOTE: CONNECT ALL DOWNPIPES TO LEGAL POINT OF DISCHARGE. LOCATIN TO BE CONFIRMED ONSITE BY BUILDER/PLUMBER WITH THE AID OF COUNCIL RECORDS. *90 DIAMETER DOWNPIPES WITH 100 DIAMETER STORMWATER BELOW @MIN 1:100 FALL.

DOWNPIPES TELEPHONE PIT SEWER INSPECTION SHAFT

WM G

GROUND FLOOR: FIRST FLOOR: GARAGE: DECKING: PORCH: TOTAL POS. : TOTAL BUILD AREA: SHARED DRIVEWAY:

1:200

GSEducationalVersion

UNIT 1 UNIT 2 100.01m² 124.13m² 94.62m² 71.75m² 38.38m² 26.75m² 22.59m² 18.86m² 7.11m² 6.39m² 60.13m² 73.78m² 157.99m² 144.78m² 156.87m²

WATER METER GAS METER

D

DECK AREA

P

PAVED AREA

G

GRASS AREA EXISTING WATER METER - TO BE REMOVED EXISTING GAS METER - TO BE REMOVED

SITE PLAN

PROJECT NAME:

CLIENT NAME:

DRAWN BY:

SCALE:

UNIT DEVELOPMENT - WORKING DRAWINGS

MR & MRS AMANDRO

NAOMI GRAHAM

1:200

DRAWING NAME:

CLIENT ADDRESS:

DATE:

DRWG NO:

SITE PLAN

13 PARK AVENUE, PRESTON, 3072

27/07/2017

A02

NG

Building

Design and Drafting


20610 6240

90

600

1094

150

710

4663

1114

240

2800

750

2850

900

430

230

D08

90

LAMINATE FLOORING

W055

4

KITCHEN

14

TILES

5

13

6

12

7

11

AJ

420

D P

240

9

AJ

420

8

W04

D P

1110

1200

10

1000

PORCH

240

15

16

3260

3

W03

W02

240

2

D01

17

496

STUDY

REF

1111

AJ

600

900 1

1308

D02

W05

8661

450

194

1000

900

W01

2266

2800

LAMINATE FLOORING

2004

850 122 974

LOUNGE

LAMINATE FLOORING

4622

D04

1030

3731

2971

900

81

D P

150

G01

D048 D048

1

2

3

4

5

6

7

8

9

10

11

17 x 179 = 3050

W054

81 D06

90

900

90

10116

D05

DINING

3073

D03

D09

WC TILES

M.

TILES

DECK

D P

LDRY

17 x 179 = 3050

CONCRETE

2311

GARAGE

AJ

2111

D048

2721

5670

6145

D047

1455

2478

AJ

D050

1455

1220

1455

W09

1053

D07

W08

D P

AJ

740

W07

HWS

1190

W06

D P

AJ

500

1234

DECK

89 900 706

D10

W056

900

240

5218

AJ

230

W056

5030 430

5161

89

1967

D P

50.60 (275°55'50")

90

204 600 900

3500

6240

1905

240

230

5510

4681

5770

4663

450

230

4197

AJ

1604

D049

S01 A05

439

5000

230

5765

1633 240

900 2400

669

1321

240

8640

900 3120

1139 150

890

900

90

2200

3116 90

3360

1300 3810

374

136 1500

240

6580

394

1790 240 2030

20610

LEGEND SMOKE DETECTOR EXHAUST FAN

1:100

PROPOSED GROUND FLOOR PLAN

AJ

ARTICULATION JOINTS

HWS

HOT WATER SYSTEM

D P

M.

GSEducationalVersion

METER BOX DOWNPIPES

PROJECT NAME:

CLIENT NAME:

DRAWN BY:

SCALE:

UNIT DEVELOPMENT - WORKING DRAWINGS

MR & MRS AMANDRO

NAOMI GRAHAM

1:100

DRAWING NAME:

CLIENT ADDRESS:

DATE:

DRWG NO:

GROUND FLOOR PLAN

13 PARK AVENUE, PRESTON, 3072

27/07/2017

A03

NG

Building

Design and Drafting


14336 6213 160

3003 787

8123

90

1600

3120

1531

160

1600

696

530 90

1000 600

980

90

2353

671

90

3810

1600

1417

160

1600

1256

2280

1779

50.60 (275°55'50") 160 1 2

160 1800

BATH ROOM

3 4

TILES

560 17 16

D P

D12

900

160

14

5

13

6

12

7

11

EN SUITE

WIR CARPET

7939

4471

639 W17

1250

D11

TILES

8

242

160

496

W03

D P

240

9

840

200

15

10

W10

900

7438

LINEN

D14

90

1200

2877

1340

W11 D15

2000

2470

450

140

3404

900

900

900

850

220

W18

51

218

D13

40

900 MH.

CARPET

D18

17 x 179 = 3050

D16

2830

501

341

D P

D P

W16

MASTER BEDROOM

LANDING

TILES

D17

900

90 90 90 160 420 409 602

2969

8182 W066

1240

1

2

3

5

6

7

8

9

10

11

12

W062

4

17 x 179 = 3050

WC

CARPET

1500 200

BIR

BIR

CARPET

D20

BED.1.

CARPET

62

3281

D054

110

BED.2.

D19 D052

W16

2110

W065 3973

W064

W14

450

W13

160

D P

W12

ROOF BELOW

S01 A05

3427 160

1723

90

900 1190

90

550

1784

4877

1090

1100 3119

929 150

3119

890

900

90

2200

4550 90

1509 90

2580

2211

160

3760

14336

LEGEND SMOKE DETECTOR EXHAUST FAN

1:100

PROPOSED FIRST FLOOR PLAN

AJ

ARTICULATION JOINTS

HWS

HOT WATER SYSTEM

D P

M.

GSEducationalVersion

METER BOX DOWNPIPES

PROJECT NAME:

CLIENT NAME:

DRAWN BY:

SCALE:

UNIT DEVELOPMENT - WORKING DRAWINGS

MR & MRS AMANDRO

NAOMI GRAHAM

1:100

DRAWING NAME:

CLIENT ADDRESS:

DATE:

DRWG NO:

FIRST FLOOR PLAN

13 PARK AVENUE, PRESTON, 3072

27/07/2017

A04

NG

Building

Design and Drafting


JAMES HARDIE F.C. EASYLAP PANELS IN DULUX 'HARPOON'FINISH. COLOURBOND CORRUGATED SHEET ROOFING @12 DEGREE PITCH IN DUNE FINISH WITH RIDGE CAPPING TO MATCH.

+84.97

COLOURBOND CORRUGATED SHEET ROOFING @5 DEGREE PITCH IN DUNE FINISH WITH RIDGE CAPPING TO MATCH.

STEELINE 110X115MM GUTTER, STEELINE FASCIA IN DUNE FINISH WITH 9MM CEMENT SHEET LINNING TO UNDERSIDE OF EAVE. CL BL +82.46

O.

2400

O.

W17

F.

+81.55

A&L ALUMINIUM WINDOWS IN SURFMIST FINISH USED ON ALL WINDOWS AND DOORS.

FFL CL

F.

M.

O.

+78.32F. AJ

420X420MM SQUARE COLUMN WITH CONCRETE CEMENT RENDER IN ECRU SMOOOTH FINISH.

O.

D09

W01

F.

+78.32

F.

GFL

D10

AJ

150

1800

2700

O.

2802

3365

350

5713

W18

GL PGH STANDARD 'GLEDSWOOD BLEND' SMOOTH FINISH BRICK WITH FLUSH LIGHT COLORED MORTAR.

COLOURBOND CORRUGATED SHEET ROOFING 85 DEGREE PITCH IN DUNE FINISH WITH RIDGE CAPPING TO MATCH.

1:100

EAST ELEVATION

COLOURBOND CORRUGATED SHEET ROOFING @12 DEGREE PITCH IN DUNE FINISH WITH RIDGE CAPPING TO MATCH. STEELINE 110X115MM GUTTER, STEELINE FASCIA IN DUNE FINISH WITH 9MM CEMENT SHEET LINNING TO UNDERSIDE OF EAVE. JAMES HARDIE F.C. EASYLAP PANELS IN DULUX 'HARPOON'FINISH.

+85.08

+84.97

R.L.

C.L.

+82.46

150

W14

F.

F.

W15

F.

F.

W13

O.

O.

F.

F.

O.

+81.52

F.

W09

AJ

O. O.

+78.32 W08

O.

O.

D08

F.

+78.32

F.

AJ

A&L ALUMINIUM WINDOWS IN SURFMIST FINISH USED ON ALL WINDOWS AND DOORS.

F.

W12

4138

2700

350

6,657

F.

F.

W16

F.F.L. C.L.

G.L.

O.

O. F.

G.F.L.

O.

6760

R.L.

O.

3200

2400

O.

W07

W06

D07

AJ

GARAGE DOUBLE BRICK WALL ON BOUNDARY. PGH STANDARD 'GLEDSWOOD BLEND' SMOOTH FINISH BRICK WITH FLUSH LIGHT COLORED MORTAR.

1:100

NORTH ELEVATION LEVELS GL GROUND LEVEL GFL GROUND FLOOR LEVEL CL CEILING LEVEL FFL FIRST FLOOR LEVEL RL ROOF LEVEL BL BOUNDARY LINE

GSEducationalVersion

PROJECT NAME:

CLIENT NAME:

DRAWN BY:

SCALE:

UNIT DEVELOPMENT - WORKING DRAWINGS

MR & MRS AMANDRO

NAOMI GRAHAM

1:100

DRAWING NAME:

CLIENT ADDRESS:

DATE:

DRWG NO:

ELEVATIONS - NORTH & EAST

13 PARK AVENUE, PRESTON, 3072

27/07/2017

A05

NG

Building

Design and Drafting


COLOURBOND CORRUGATED SHEET ROOFING @5 DEGREE PITCH IN DUNE FINISH WITH RIDGE CAPPING TO MATCH. STEELINE 110X115MM GUTTER, STEELINE FASCIA IN DUNE FINISH WITH 9MM CEMENT SHEET LINNING TO UNDERSIDE OF EAVE. JAMES HARDIE F.C. EASYLAP PANELS IN DULUX 'HARPOON'FINISH. RL

+85.08

+84.97

+84.35

+84.43

RL RL

W10

+81.72

F.

RL

W11

RL

FFL CL

F.

F.

F.

M

+78.32

FL G01

150

GL

W05

AJ

O.

F.

AJ

W04

W03

W02

AJ

4138

+78.32

D01

GFL 150

O.

3402

2700

3200

O.

350

CL

O.

A&L ALUMINIUM WINDOWS IN SURFMIST FINISH USED ON ALL WINDOWS AND DOORS.

2700

6760

RL

6,657

+82.46

6106

O.

O.

2400

6025

CL

GL 420X420MM SQUARE COLUMN WITH CONCRETE CEMENT RENDER IN ECRU SMOOOTH FINISH. PGH STANDARD 'GLEDSWOOD BLEND' SMOOTH FINISH BRICK WITH FLUSH LIGHT COLORED MORTAR.

1:100

SOUTH ELEVATION

JAMES HARDIE F.C. EASYLAP PANELS IN DULUX 'HARPOON'FINISH.

COLOURBOND CORRUGATED SHEET ROOFING @12 DEGREE PITCH IN DUNE FINISH WITH RIDGE CAPPING TO MATCH.

COLOURBOND CORRUGATED SHEET ROOFING @5 DEGREE PITCH IN DUNE FINISH WITH RIDGE CAPPING TO MATCH. +85.08

RL

RL

+84.03

+83.97

STEELINE 110X115MM GUTTER, STEELINE FASCIA IN DUNE FINISH WITH 9MM CEMENT SHEET LINNING TO UNDERSIDE OF EAVE.

CL

BL

CL

+78.32

+78.32

GFL 150

GARAGE DOUBLE BRICK WALL ON BOUNDARY.

+78.32

150

GL

2700

2700

3200

GFL

6106

FFL CL

RL 350

6760

2400

A&L ALUMINIUM WINDOWS IN SURFMIST FINISH USED ON ALL WINDOWS AND DOORS.

AJ

GL PGH STANDARD 'GLEDSWOOD BLEND' SMOOTH FINISH BRICK WITH FLUSH LIGHT COLORED MORTAR.

1:100

WEST ELEVATION LEVELS GL GROUND LEVEL GFL GROUND FLOOR LEVEL CL CEILING LEVEL FFL FIRST FLOOR LEVEL RL ROOF LEVEL BL BOUNDARY LINE

GSEducationalVersion

PROJECT NAME:

CLIENT NAME:

DRAWN BY:

SCALE:

UNIT DEVELOPMENT - WORKING DRAWINGS

MR & MRS AMANDRO

NAOMI GRAHAM

1:100

DRAWING NAME:

CLIENT ADDRESS:

DATE:

DRWG NO:

ELEVATIONS - SOUTH & WEST

13 PARK AVENUE, PRESTON, 3072

27/07/2017

A06

NG

Building

Design and Drafting


90X45 MGP10 TIMBER STUDS @450 CTRS, R2.0 BULK INSULATION WITH REFECTIVE FOIL SARKING, JAMES HARDIE F.C. EASYLAP PANELS IN DULUX 'HARPOON'FINISH. RL COLOURBOND CORRUGATED SHEET ROOFING @5 DEGREE PITCH IN DUNE FINISH ON 70X35 ROOFING BATTENS @ 900 SPACING ON ROOF TRUSSES TO ENGINEERS SPECIFICATIONS @600 SPACINGS.

CL

NORTH BOUNDARY

FFL CL

D13

W15

90X45 MGP10 TIMBER STUDS @450 CTRS, R2.0 BULK INSULATION WITH REFECTIVE FOIL SARKING, PGH STANDARD 'GLEDSWOOD BLEND' SMOOTH FINISH BRICK WITH FLUSH LIGHT COLORED MORTAR.

LANDING

1210

W03

A&L ALUMINIUM WINDOWS IN SURFMIST FINISH USED ON ALL WINDOWS AND DOORS.

STAIRWELL 81520

350

6657

2400

83920

17 16

81170

15 14

LOUNGE

305mm POSI-STRUT TO ENGINEERS SPECIFICATIONS WITH 10MM CEILING LINNING ON THE UNDERSIDE.

13

11

D08

10

D09

795

2410

12

9

2700

8

900

3

341

1435

5 4

178

7 6

LAMINATE FLOORING ON REINFORCED CONCRETE SLAB WITH POLYURETHANE VAPOUR BARRIER WITH 50MM PACKING SAND

2 F.

GFL

F.

O.

O.

1 F.

400

150

GL

78470 78320

350

1:50

SECTION 01

LEVELS GL GROUND LEVEL GFL GROUND FLOOR LEVEL CL CEILING LEVEL FFL FIRST FLOOR LEVEL RL ROOF LEVEL BL BOUNDARY LINE

GSEducationalVersion

PROJECT NAME:

CLIENT NAME:

DRAWN BY:

SCALE:

UNIT DEVELOPMENT - WORKING DRAWINGS

MR & MRS AMANDRO

NAOMI GRAHAM

1:50

DRAWING NAME:

CLIENT ADDRESS:

DATE:

DRWG NO:

SECTION 01

13 PARK AVENUE, PRESTON, 3072

27/07/2017

A07

NG

Building

Design and Drafting


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.