Neodent Catalog of Products

Page 1

14

Technical Guidance

28

Morse Taper

54

External Hex

80

Internal Hex

98

Transgingival

110

Zygomatic

118

Surgical Techniques

132

Orthodontic Anchorage and Bone Grafting

140

Instrumental

156

Surgical Instruments 1


Neodent is much more than dental implants .

It’s a company made for you.

2


W

e are a 100% Brazilian company with over 16 years of history, focused essentially on our clients. We have as main characteristic to provide solutions with high technology and assured quality. Operating in five continents, we are proud to be one of the biggest manufacturers of dental implants and prosthetic components in the world.

Leader in Brazil, we have the satisfaction of our clients as our main objective. Therefore, we are commited to work with seriousness and dedication to offer you much more than dental implants. This you already know. What maybe you don´t know is that "much more" implies in aggregate values and qualities that act directly with your work. “Much more” was the result of our

commitment to research and development of new technologies, which allied with sustainability, results in a modern industrial complex which is environmentally correct. The “much more” is present from our technical support, prepared to answer with excellence, even in critical situations. We want to always be much more, so that you also continue being so.

3


The industry To guarantee our innovative potential and high technology, we inaugurated in 2009 the New Industrial Complex with 12.000 m² in one plot of 50.000m², expanding the production potential like no other one in Latin America. The entire project was thought up so that the structure could transmit our values: advances in technology, respect for human beings and socio-environmental responsibility.

PRODUCTION

Continuous Development and Quality Control Besides being able to count upon the best and most modern robotic equipment, the New Industrial Complex hosted a complete materials laboratory: The Integrated Laboratory of Materials – LIM, aimed directly at research, development and quality control. In LIM, we have the Scanning Electron

Microscope

(MEV),

which

assures

quality from the raw-material through to the end product. The equipments for mechanical and metallographic tests assess long-term resistance and enable the microstructural analysis of products. All of this is reflected in excellence for you, client who trusts and takes our name into your consulting room.

QUALITY CONTROL

4


SALA LIMPA CLEAN ROOM

SCANNING ELECTRONIC MICROSCOPE

CYCLIC MECHANICAL TESTS

5


Respect to

AUDITORIUM: CONSTANT PROFESIONAL TRAINING

human standards

RESTAURANT

SPORT COURTS

The respect to human standards is a principle trait in the architectural design of the New Industrial Complex, highlighted by the preference for naturally lit environment and of the use of materials and technologies that provide greater thermoacoustic comfort. Now, our employees have much more infrastructure and ergonomy for their daily activities. We also have a fully-equipped restaurant visually integrated into the grove, which attends to the necessities of the employees and visitors, including during the diverse events promoted. Concerned with constant trainning, we constructed a spacious auditorium to promote the transmission of knowledge, one of the important pillars of our essence. Besides intellectual development, encouragement towards sport is also a priority: sport courts, a golf course, football and wood forest for hiking. These values are the base of a strong trademark that focuses on the people and works for their wellbeing.

6


Environment We work with socio-environmental responsibility, respecting the ideal conditions for growth without harming the planet, and evoking the same consciousness in the whole team of employees and partners. LIQUID TREATMENT STATION

PREFERENCE FOR NATURAL LIGHT

7


We count on the scientific support of ILAPEO – The Latin American Institute of Research and Dental Education - , a centre of excellence in research, advances and innovations in the clinical practice of dentistry. An institute made up of professionals, professors and researchers of the highest level of knowledge who offer post-graduate courses, such as specialisation and master’s degree, recognised by CFO, MEC and CAPES.

MULTIDISCIPLINARY LABORATORY

BLUE CLINIC

AUDITORIUM

8

RECEPTION


Certificates Quality certificates •RDC 59/2000 – ANVISA - Certificate of Good Practices in the Manufacture and Control of Health Products; •ISO 13485 – Health Products – Systems Quality Management – Requisites for regulatory purposes; •CE MARK – European Directive 93/42 CEE – Relative to the Medical Devices; •ISO 9001 – Systems Quality Management.

A global company As well as industrial and commercial headquarters in Curitiba (PR) state of Paraná,Brazil, we also have ten branches in São Paulo (capital), Bauru, Rio de Janeiro, Belo Horizonte, Porto Alegre, Goiânia, Brasília, Londrina, Recife and Vitória. Eight authorised distributers installed in seven states (Amazonas, Bahia, Mato Grosso, Mato Grosso do Sul, Pará, Santa Catarina and Tocantins), as well as branches in Lisbon, Portugal and U.S.A. An international network is spread across more than 13 countries: Argentina, Bolivia, Chile, Colombia, Spain, Italy, Lebanon, Morocco, Peru,

Dominican

Republic,

Taiwan,

Thailand and Venezuela.

The largest company in the Brazilian market, and one of the biggest in the world market, now operating in U.S.A.

Contact Always here for your needs, you can count on our channels of communication: •SAC 08007072526 •Ombuds 08007256363 •www.neodent.com.br •www.neodentusa.com

9 COMMERCIAL HEADQUARTERS


NEOSHAPE

CAD CAM SYSTEM Welcome to the technological innovations that now present themselves to the world of prosthesis. Neodent has the pride and pleasure to announce the Neoshape CAD CAM System. A system that combines new market trends to guarantee precision and quality in the production of the existing prostheses. This breakthrough opens new horizons, offering excellence in personalised aesthetics and planning with digital precision.

1. Pacient

5. End of the prosthesis with porcelain application

2. Scanning

4. Customized piece fabrication in NEODENT Milling Center 3. CAD moulding in 3D planning software

Available Neoshape System Products: •Single or multiple Copings; •Infrastructures of fixed prosthesis; •Infrastructures of hybrid prosthesis (protocol);

Differentials: •Micrometric adaption; •Optimization of production time; •3D Virtual 3D waxing;

•Customized Abutments;

•Laser Technology - Precision and

•Acrylic Infrastructures.

quickness in scanning.

The Neoshape CAD/CAM System allows the choice of diverse materials with an emphasis on Zirconia, Cobalt Chromium, Titanium and Acrylic.

10


CAD CAM SYSTEM How the Neoshape CAD/CAM System works: The dental prosthesis technician (DPT) can plan on the computer screen in three-dimensional shape all aesthetic and functional details of differents prosthetic resolutions in day-to-day laboratorial.

After the virtual waxing conclusion, a computer file is sent to the Neodent Milling Center. The information management is carried out on every received case; then, the file is forwarded to manufacture, where the latest equipment, dedicated exclusively to the Neoshape System, produces the received cases with precision and quality guarantee.

There is where the waxing stops being virtual and becomes real, adding up Neodent technology to the professional knowledge and patient biotype, making smiles more natural and beautiful.

The Neoshape System offers a large library of prosthetic interfaces jointly with its 3D modeling software.

Amongst them:

•Rotational External Hex; •Anti-rotational External Hex; •Mini Conical Abutment; •Universal Post; Also, there is a available option: the metallic

Independent from the chosen material for the prosthesis construction, the mechanical properties and the quality guarantee are ensured by international raw materials of controlled origin, reinforcing our ethical commitment and offering you products with excellence.

interfaces, cemented to the personalised abutments, so that the contact of the implant is obtained through metal with metal.

•Anti-rotational External Hex; •Internal Hex.

The Milling Center The fabrication process starts with the receiving of

Once all the fabrication procedures are

the 3D archive, already projected by the prothesis

concluded, the products are sent directly to the

technician, using the CAD modeling software (virtual

professionals, who now has more time to

waxing).

carry out the perfect layering of

Then, the CAM software defines the best strategy for

the porcelain, ensuring

the production of the received file, taking into account

quality and aesthetics

the dimensions and the particularities of each case, in

in their work.

order to get the result exactly as the same projected by a professional. The latest technology machines execute the milling in an efficient way and with high precision, making the fabrication possible from the single copings through to complete arches. The exquisite finishing of the margin lines, edges and the adaption of the copings and customized abutments with the help of Neoshape system are insurmountable.

11


NeoPoros

Surface Constant evolution and security guarantee

Following years of intense research and development of new technologies, Neodent has achieved the most modern and current techniques for the surface treatment of implants: the Neoporos Surface. Based on the abrasive blasting concept followed by acid subtraction, the Neoporos Surface promotes, from on the use of oxides with controlled granulometry, irregular craters on the implant surface, which are then standardized by the acid subtraction technique. The surface uniformity is obtained during the abrasive blasting and is assured by virtue of the speed robotised control, pressure and particle size that collide with the implant. Various scientific studies are still under way, so that the Neoporos surface is always evolving and promoting much more security for you

Electronic microscopes of the Neoporos Surface in amplifications of 2000X and 5000X. Roughness controlled to guarantee the size of the pores between 2.5 and 5.0Îźm in the entire implant surface.

12


Surface

Histological study of the bone tissue response of

Neodent implants with Neoporos Surface.

Direct contact of the bone to the implant, showing osteogenesis by contact and the osseous induction potential of Neoporos Surface.

Bone crest formed over a cervical portion of the Morse taper implants with Neoporos surface after a period of osseointegration.

13


T e c h n i c a l G u i d a n c e

14


15

Technical Guidance


IMPLANT INDICATION TABLE In accordance with the bone classification of Lekholm and Zard (1985)

Bone type

I

Bone type

II

Bone type

III

Bone type

Morse Taper

Morse Taper

Morse Taper

with Mount

with Mount

"C" Implant Apex

16

"M" Implant Apex

Alvim Implant Apex

EX Implant Apex

IV


CONNECTIONS AND TORQUES

1.2

0.9

Conical 4.1

1.6

Conical and Slim Fit Abutment (Ø 4.1 and Ø 4.3)

20N.cm 20N.cm

Conical Abutment (Ø 5.0)

20N.cm

Mini Conical Abutment (Ø 4.1 and Ø 4.3) 20N.cm

Mini Conical Abutment (Ø 5.0)

32N.cm

Mini Abutment Slim Fit External Hex

Universal Post, Personalizable, Angled and Slim Fit

32N.cm

UCLA (ø3.3)

20N.cm

UCLA (ø4.1; ø4.3; ø5.0)

32N.cm

Mini Ball Attachment

32N.cm 10N.cm

Cylinders

32N.cm

CM and WS Abutment 15N.cm

Angled Mini Conical Abutment CM CM Mini Conical Abutment and WS and CM Micro Abutment

32N.cm

Universal Post CM and WS MORSE TAPER

32N.cm

Universal Post Througt Bolt and Angled

15N.cm

Mini Ball Attachment

32N.cm

Cylinders

Internal Hex

10N.cm

Conical Abutment II Plus

20N.cm

Mini Abutment II Plus

20N.cm

Universal Post II Plus

20N.cm

Angled Post II Plus

20N.cm

UCLA II Plus

20N.cm 20N.cm

Mini Ball Attachment Cylinders

GT

10N.cm

Cylinders

20N.cm

TRANSGINGIVAL

SELECTION OF PROSTHETIC COMPONENTS ACCORDING TO THE ABUTMENT/IMPLANT INTERFACE

Working manner A. Overdenture abutment Multiple Prosthesis

1. Screw retained Type of Prosthesis

•Mini Conical Abutment •Transepithelial Abutment •Micro abutment

Multiple Prosthesis

2. Cemented •Universal Post •Personalizable Post

Single Prothesis •Conical Abutment •CM Abutment

Single Prothesis •Universal Post •Universal Post •Personalizable Post

B. Directly on the implant Multiple Prosthesis

Single Prothesis

•UCLA

Multiple Prosthesis

Single Prothesis

•UCLA

17


30º

18

5.90 4.90

3.90 3.50

2.50

2.90

1.50

4.50

3.50

3.50

5.80

3.50

4.80

2.50

3.80

1.50

5.20

3.50

4.20

2.50

ø 3.3

4.90 3.50

3.90 2.50

1.50

4.90

3.50

3.90

2.50

3.20

1.50

2.50

1.50

17º

2.50

30º

2.90

1.50

Height of the CM Angled Prosthetic Components

Angled Universal Post ø 4.5

Angled Mini Conical Abutment


CYLINDERS FOR OVERCASTING The cylinders and UCLAs for overcasting present

out in accordance with the handling instructions

with perfect adaption and perfect fitting,

as described in the manual, as well as in the

following international quality regulations and

instructions provided by the various manufacturers

standards. The dimensional tolerance between

of overcasting alloys. Thus, the oral rehabilitation

implants, intermediates and manufactured belts,

team can ensure success for the technique more

as well as the individual analysis of each piece,

safely. For best results, always use the entire

are the differences of these components that

sequence of Neodent® products (analogues,

pass through strict industrial quality control at a

abutments, screws, transfer copings, and protectors).

micrometric level.

Believing in the importance of allowing the

NEODENT

RESPECTING YOUR WORK:

customer to choose the product, we offer different All of these products are manufactured using the

metallic alloy cylinders with pre-fabricated belts

latest equipment, ensuring the best adaption.

bases for overcasting.

Castable polymers sleeves fitted over the metal bases are replaced with metal after the

They are:

overcasting process, thus the pre-fabricated

− Cobalt-Chromium;

metalic base has a higher fusion temperature

− Tilite;

than the metal to be overcast. Such polymers

− Gold (Gold Alloy);

facilitate the finishing process of the parts and

− Zirconia.

ensure the overlapping of the overcast metal to the pre-manufactured metal. However, the casting process does not follow the same quality control that the manufacturing process does, therefore, the dental technician should often check for the absence of positive metallic porosities in the screw passage tube. Therefore, the overcasting technique maintains the quality of the fittings among the guaranteed parts from the factory and enables the design and individualisation of the infrastructure, to allow additional material on the manufactured base to hold its shape. The use of these products should be carried

19


NEODENT

HANDLING OF

CYLINDERS FOR OVERCASTING

Regardless of the type of alloy chosen, the

3. Finishing and metal polishing:

dental technician should take special care when

The disembedding of the casted object at

handling the pre-fabricated cylinders, thus

the coating must be done carefully, avoiding

improving the quality of the overcasting and the

abrasive jets blasts, which may alter the pre-

ceramic application processes.

fabricated surface. It is recommended to machining the final

1. Waxing:

infrastructure at a low rotation with the use

The edges waxing of the component cannot

of refrigeration, with specific drills for metal.

overrun the borders that come into contact with

Both of the areas corresponding to the stop of

the implant or the prosthetic component (metallic

the head of the prosthetic screws inside the

base of cylinder), guaranteed to preserve and

passing tube must maintain their full original

adapt the industrial quality control process.

shape, without the presence of positive metal porosities or deformations.

2. Overcasting:

The edges of the cylinders must be covered by

The prosthetic cylinders are made non-sterile

polishing protectors during the polishing and

and are suitable for single use. The metal bases

the finishing of the infrastructure. Corrosive

are manufactured with alloys that have a high

materials, such as those with iron particles,

fusion temperature compared to the metal that

should also not be used.

is to be overcast. In cases where the metal for

Very strict criteria should be applied, because

overcasting has a higher fusion temperature than

flaws in overcasting procedure may cause the

the manufactured parts, they will deform due

loss of the entire work.

to high temperatures. However, if the metal due to be overcast has a fusion temperature much

4. Ceramic application:

lower than the metal in the base, bonding may

The porcelain choice should correspond

occur between the parts and the base of the

to the used alloy (CoCr, Tilite or Gold). The

component, which could result in the release of

ceramic cannot be applied directly over the

the infrastructure.

manufactured bases of the cylinder, so that the

All the cylinders with pre-fabricated bases are

waxing and the overcasting ensure a complete

evaluated one by one, from the reception of the

covering of the infrastructure area in which the

raw material, which is analysed before production,

ceramic is to be applied.

to its final packaging, ensuring quality throughout the entire manufacturing process.

20


NEODENT

COBALT-CHROMIUM PRODUCTS LINE (CoCr) The cylinders for overcasting with pre-

The chemical composition of the high fusion CoCr alloy

fabricated bases of Cobalt-Chromium (CoCr),

follows is in accordance to the international regulation

have a high resistance to water corrosion and

ASTM F-1537, by following this chemical composition:

elevated mechanical resistance to withstand occlusal loads. This is an alloy that has a high biocompatibility and is easy to use by the technician, with an excellent acceptance of

CHEMICAL ELEMENT

Composition (%)

ceramic application for CoCr. In addition, this alloy

Cobalt

58 to 69

is compatible with one of the strongest trends in

Chrome

26 to 30

Molybdenum

5 to 7

Max. Nitrogen

0,25

Max. Carbon

0,14

healthcare worldwide in its absence of Nickel in its chemical composition, resulting in lower risks of allergenic reactions when in contact with living tissues, such as the oral mucosa.

Several cylinders and UCLAs are available in this alloy, and from the customised infrastructures of the Neoshape line. Note the options and mechanical characteristics (rotational or antirotational) for each case, as well as the sequence of products found in this catalogue.

Important information: •Melting range: 1.287 to 1.378°C (2.348 to 2.512 °F); • Density: 8,28 g/cm³; • Coefficient of thermal expansion: 14,2µm/K (600°C).

An alloy compatible for the overcasting procedure that is in accordance with regulations ASTM F1537, ASTM F799, ISO 5832-12 or ISO 5832-4 should be chosen.

The thickness of the metal after overcasting must be at least 0.5 mm, and can be reduced during manufacturing and finishing by up to 0.3 mm.

Welding must be done in the range of 1.120 to 1.150°C (2.048 to 2.102 °F)

21


NEODENT

TILITE LINE The cylinders for overcasting with pre-fabricated bases in Tilite must always be overcast with Tilite alloys (Talladium, Curitiba, Brazil). The Tilite metallic alloys are alloys with a highly resistant NiCr base. The pre-fabricated base has a high fusion temperature, accepting only the Tilite alloys for overcasting. Depending on the ceramic used by the dental technician, they must select which Tilite alloy is to be made in overcasting, according to the table below:

TILITE ALLOY

Premium (P)

CERAMIC Carmen, Ceramax Ceramco, Ceramco II, Ceramco III, C-Mix, Duceram, Duceram Kiss, Elephant, Excelco, Excelsior, Finesse, Fortune, GC Initial MC, Illusion, IPS InLine, Jelenko, Life Essence, Micro-Bond, Microlucent, Olympic II, Pencraft, Reflex, Silhouette, Solera, Tru-Est, Vintage-Halo, Vision, Willians/Wilceram

Important information: •Melting range: 1.204 to 1.302°C (2.200 to 2.375 °F); •Density: 7,7 g/cm³; •Coefficient of thermal expansion: varies according to the Tilite league selected;

Vita (V)

Star (S)

BMK, Creation, Duceram Plus, Elite, Hera Ceram, Symbio Ceram, Vintage-Regular, Vita Omega 900, VM 13, VMK-68, VMK-68N

Avante, Ceramco II Silver, Noritake EX-3, Spectrum, Starlight, Synspar

•Welding must be done in the range of 1.050 to 1.110°C (1.922 to 2.030 °F).

More information can be found in this article: SARTORI, IAM; VELOSO, R. Neodent and Talladium: Casting of the Tilite

Omega (Ω)

IPS Clasic, IPS d.Sign, Vita, Omega VMK-95

manufactured components. Implant News, no. 5, vol. 2, Sept/ Oct 2005.

PMF

Luminesse

Several cylinders and UCLAs are available in

CHEMICAL ELEMENT

Composition (%)

this alloy. Note the options and mechanical

Níckel

characteristics (rotational or anti-rotational) for each case, as well as the sequence of products found in this catalogue.

22

60 to 76

Chrome

12 to 21

Molybdenum

4 to 14

Titanium

4 to 6


NEODENT

GOLD LINE Important information: Among the metallic alloys, the cylinders for overcasting with pre-fabricated bases in gold are to be the first choice for the construction of prosthetic infrastructures on dental implants. Of all of the

• Melting range: 1.400 to 1.490°C (2.552 to 2.714 °F); • Density: 17,5 g/cm³; • Coefficient of thermal expansion: 12,2µm/K (600°C).

existing metallic alloys for the manufacture of dental prosthesis, none were better than the gold alloys in relation to intraoral survival time due to their following characteristics:

The alloys must be chosen to be compatible with the overcasting procedure (gold or semigold) that are in accordance with regulation

• Excellent biocompatibility: no cytotoxic potential (extraction test ISO 10993-5) or allergenic reaction (ISO 10993-10 maximized); • Extremely low levels of corrosion (according to regulation ISO/DIS 10271);

ISO 9693 and ISO 22674.

The thickness of the metal after overcasting should be at least 0.5 mm.

Welding must be done in the range of 800 to

• Excellent mechanical properties; • Reduction of friction coefficient between parts;

890°C (1.472 to 1.634 °F).

• Increased pre-load of the prosthetic screw.

From a technical point of view, this is an alloy of easy handling for the DENTAL TECHNICIAN, since it has an optimal hardness, low capacity for deformation and a white colouring, which makes aesthetics easier. Its high fusion temperature permits overcasting with gold and semi-gold alloys and results in complete safety for the ceramic application.

Cylinders on mini abutments and UCLAs are available in this alloy.

The gold alloy with a high melting has the following chemical composition:

CHEMICAL ELEMENT

Composition (%)

60

Palladium

20

Platinum

19

Iridium

1

Gold

23


NEODENT

ALUMINA LINE In line with global aesthetic trends, the following

Note the sequence of procedures for utilization of

cylinders are available for the sequence of

this product found in this catalogue.

Universal Posts made of Aluminium Oxide: The Alumina line, indicated to cemented unitary

Aluminized feldspatic ceramics are suitable for

prostheses without metal, have the following

the application of these Alumina cylinders. Some

characteristics:

situations require the customisation of the cylinder

• Superior aesthetics and excellent

in order to avoid the excess of unsupported

biocompatibility;

feldspar ceramics, as following the manufacturer’s

• Absence of metallic margin;

instructions of the ceramics. For this, the DENTAL

• Best translucency;

TECHNICIAN must use aluminized ceramics of

• Security on marginal adaptation;

margin or reconstruction, fabricating the final

• Effective Mechanical properties;

infrastructure before the application of the porcelain.

• No possibility of thermal conductivity or oxidation; • Excellent cost/ benefit; • Technical procedures widely known by the DENTAL TECHNICIANS.

24


Zirconium (Zr) is the basic chemical element of

Important information:

Zirconia line. In accordance with the periodic

•Density: 5,3 g/cm³;

table, this is a transition metal and has many

•Flexural resistance: ≥ 1700 MPa.

NEODENT

ZIRCONIA PRODUCTS LINE (Y-TZP)

interesting features, such as high mechanical and corrosion resistance. From this element, is

Special care must be taken when handling

obtained Zirconium Dioxide (ZrO2), better known

Zirconium. The Posts, UCLAs, and infrastructures

as Zirconia.

should not be subjected to the sterilisation,

Zirconia has white colour and a crystalline

which may result in the loss of their mechanical

monocyclic structure. The addition of Yttrium

properties. Moreover, some precautions should be

Oxide (Y2O3) in its composition results in the

taken during the preparation:

formation of a tetragonal crystal (TPZ), which,

•The use of fine grained diamond drills;

from a mechanical point of view, is very important

•Sufficient refrigeration;

because it inhibits the propagation of cracks, a

•Finishing with specific rubber rotatory

fact commonly noted in ceramics in general.

instruments to avoid micro-cracks.

With the scientific name of Tetragonal Zirconium Oxide Polycrystal, stabilized with dense Yttrium

Porcelains specific for Zirconia must be chosen for

highly pure (Y-TZP), the Zirconia line is compliant

application. Note that in some cases the UCLAs

with regulation NBR ISO 13356. It has the

may need the infrastructure in order to increase

following characteristics:

the ceramic volume supported in function of

•Biocompatibility;

the distance of the antagonist and proximal

•White colouring;

dental elements. The Universal Posts must have

•High resistance to corrosion;

infrastructures, whether customizable with

•Limits the formation of cracks;

Neoshape system, or over aluminium cylinders.

•High fracture tenacity.

Today, there are few industries that have the technology to process Zirconia. Therefore, after intensive research, we can offer our clients a line of UCLAs, Universal and Anatomical Posts, as well as customizable infrastructures with our Neoshape line. Not the sequence of this product found in this catalogue.

25


NEODENT

CASTABLE PRODUCTS LINE A product line that gives to DENTAL TECHNICIAN complete freedom to cast the infrastructure with a metallic alloy of their choice, directly over the implant platform or abutment. Often, price is the decisive factor in this choice. Therefore, the adaptation quality to the implant primarily depends on the care in handling by the professional, providing quality assurance of prosthetic components with pre-fabricated metallic base. After casting, we suggest that you always evaluate the adaptation of the analogues prior to cementing the crown.

The castable components are available for all cylinders on intermediary, Universal Posts and UCLAs. Note the sequence of this product found in this catalogue.

26


NEODENT

TITANIUM LINE Among the more traditional alloy in implantology, there is the Titanium, conforming to regulation ASTM F136- Ti6Al4V. Known as Titanium grade V, it is widely used in the manufacture of provisional prosthesis. The dentist or the DPT can adapt resin crowns pre-fabricated over the cylinders and can create temporary crowns with perfect fitting and security, or even create a temporary crown directly over the cylinders, which can be used in immediate loading situations. The prosthetic components in Titanium are provided sterile, guaranteeing security and strengthening our ethical commitment with you. Pre-fabricated components in Titanium must not be overcasted. Although Titanium has a high fusion temperature (approx 1680 ยบC), the alloy undergoes structural changes when subjected to high temperatures. Therefore, metallic alloys with Titanium base still remain a challenge to the science of dental material.

The Titanium prosthetic components are offered as cylinders for all intermediates and implants, also as customized infrastructures with the Neoshape line. Note the mechanical characteristics (rotational or anti-rotational) of each case and the sequence of products found in this catalogue.

27


M o r s e T a p e r

28


• GAP reduced (impermeable fitting); • Stable Anti-rotational fixing; • High mechanical strength; • Unique prosthetic interface, independent of the implant diameter; • First system with Cone morse fitting in Brazil; • The CM angle and the internal thickness of the implant enable the design of the screw thread to reach the cervical portion of the implant; • High resistance, comparable to implants with external hex with regular platform; •NeoPoros Surface.

MORSE TAPER CONE MORSE IMPLANT

ø2

.5 m

ØI

mp

m

t

WS CONE MORSE CM ZYGOMATIC

.0 m

m

4.0, 5.0 e 6.0 mm pla

nt

•CM Abutment (single) •Mini Abutment CM (multiple) •Angled Mini Abutment CM 17º and 30º (multiple) Micro Abutment CM (multiple)

3.5, 3.75, 4.0, 4.3 e 5.0 mm

lan

Ø3

Ø Im

Screw retained Prosthesis

•WS Abutment (single) •Mini Abutment WS (multiple) •CM Transepithelial Abutment (multiple)

Cemented Prosthesis •CM Angled Universal Post 17° and 30° •CM Universal Post Throug Bolt •CM Universal Post (unique body) •Anatomical and Universal Zirconia Post

• WS Universal Post with Screw

Overdenture •CM Mini Ball Attachment •Clip Bar •CM Mini Abutment •CM Micro Abutment

Protocol •CM Micro Abutment •CM Mini Abutment •Angled Mini Conical Abutment 17° and 30° •Cylinder and Distal Bar Passive Fitting Technique •Cylinder - Castable Mini Abutment •Cylinder - Titanium Mini Abutment •Cylinder - Brass Mini Abutment

•Mini Abutment WS Passive Fitting Technique • Castable GT Cylinder • Titanium GT Cylinder • Brass GT Cylinder

29


Implants

Product Characteristics •Cylindrical implant with Morse Taper interface; •NeoPoros Surface; •Pre-mounted; •Double thread (faster installation and less trauma); •High cutting capacity; •Suitable for bones type I and II; •Cover screw not included; •Unique prosthetic interface for all implant diameters; •Cervical diameter equal to implant diameter; •Observe the specific Pilot Drill (same function of countersink drill); •Better prosthetic resolution with CM Implant inserted 2mm intraosseous,below the crest level; •Perforation rotation: 800-1200 rpm; •Insertion rotation: 30 rpm.

CM Pilot 4.3/5.0

Titamax Drill 4.3

Titamax Drill 3.8

CM Pilot 3.3/4.0

CM Pilot 3/3.75

Titamax Drill 3.3

CM Pilot 2.8/3.5

Titamax Drill 3.15

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drill Sequence

3.5 mm 3.75 mm 4.0 mm 5.0 mm Optional

30


7.0 mm

8.0 mm

9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.556

109.557

109.558

109.559

109.560

109.561

109.562

109.544

109.545

109.546

109.547

109.548

109.549

109.550

109.509

109.510

109.511

109.512

109.513

109.514

109.515

109.529

109.530

109.531

109.532

109.533

Ø 3.5

Ø 3.75

Ø 4.0

Ø 5.0

CM Cover Screw 2 mm

117.013

117.017

Healings 0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

6.5 mm

Ø 3.3

106.182

106.168

106.169

106.170

106.183

106.184

106.185

Ø 4.5

106.175

106.171

106.172

106.173

106.174

106.180

106.181

31


Implants

Morse Taper

Product Characteristics • Cylindrical implant with Morse Taper interface; • NeoPoros Surface; • Pre-mounted; • Double thread (faster installation and less trauma); • High compaction capacity (bone expansion); • Suitable for bones type III and IV and in areas with little bone thickness ; • Cover screw not included; • Unique prosthetic interface for all implant diameters; • Cervical diameter equal to implant diameter; • Simplified instrumentation in the prepare of surgical alveolus; • Best prosthetic resolution with CM Implant 2mm infraosseous; • Perforation rotation: 800-1200 rpm; • Insertion rotation: 30 rpm;

CM Pilot 4.3/5.0

Titamax Drill 4.3

Titamax Drill 3.8

CM Pilot 3.3/4.0

CM Pilot 3/3.75

Titamax Drill 3.3

CM Pilot 2.8/3.5

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drill sequence

3.5 mm 3.75 mm 4.0 mm Optional

32


Morse Taper

9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

19.0 mm

109.565

109.566

109.567

109.569

109.570

109.571

109.572

109.573

109.517

109.518

109.519

109.520

109.521

Ø 3.5

109.563

109.564

Ø 3.75

109.568

Ø 4.0

109.516

CM Cover Screw 2 mm

117.013

117.017

Healings

Ø 3.3 Ø 4.5

0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

6.5 mm

106.182

106.168

106.169

106.170

106.183

106.184

106.185

106.175

106.171

106.172

106.173

106.174

106.180

106.181

33


Implants

Product Characteristics •Cylindrical implant with Morse Taper interface; • NeoPoros Surface; • Pre-mounted; • Double thread (faster installation and less trauma); • High compaction capacity (bone expansion); • Suitable for bones type III and IV; • Cover screw not included; • Unique prosthetic interface for all implant diameters; • Observe the specific Pilot Drill (same function of countersink drill); • Cervical diameter equal to implant diameter; • Best prosthetic resolution with CM Implant 2mm infraosseous; • Perforation rotation: 800-1200 rpm; • Insertion rotation: 30 rpm;

CM Pilot 4.3/5.0

Titamax Drill 4.3

Titamax Drill 3.8

CM Pilot 3.3/4.0

CM Pilot 3/3.75

Titamax Drill 3.3

CM Pilot 2.8/3.5

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drill sequence

3.75 mm 4.0 mm Optional

34


9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.594

109.595

109.596

109.597

109.598

109.599

109.600

109.601

109.602

109.603

Ø 3.75

Ø 4.0

CM Cover Screw 2 mm

117.013

117.017

Healings

Ø 3.3 Ø 4.5

0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

6.5 mm

106.182

106.168

106.169

106.170

106.183

106.184

106.185

106.175

106.171

106.172

106.173

106.174

106.180

106.181

35


Implants

Product Characteristics • Conical implant with Morse Taper interface; • NeoPoros Surface; • Pre-mounted; • Double thread (faster installation and less trauma); • Suitable for bones type III and IV and pos-extracting installation; • Cover screw not included; • Unique prosthetic interface for all implant diameters; • Observe the specific Pilot Drill (same function of countersink drill); • Cervical diameter equal to implant diameter; • Best prosthetic resolution with CM Implant 2mm infraosseous; • Perforation rotation: 500-800 rpm; • Insertion rotation: 30 rpm;

CM Pilot 4.3/5.0

Alvim Drill 5.0

CM Pilot 3.6/4.3

Alvim Drill 4.3

CM Pilot 2.8/3.5

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill sequence

3.5 mm 4.3 mm 5.0 mm Optional

36


8.0 mm

10.0 mm

11.5 mm

13.0 mm

16.0 mm

109.551

109.552

109.553

109.554

109.555

109.534

109.535

109.536

109.537

109.538

109.539

109.540

109.541

109.542

109.543

Ø 3.5

Ø 4.3

Ø 5.0

CM Cover screw 2 mm

117.013

117.017

Healings

Ø 3.3 Ø 4.5

0.8 mm

1.5 mm

2.5 mm

3.5 mm

4.5 mm

5.5 mm

6.5 mm

106.182

106.168

106.169

106.170

106.183

106.184

106.185

106.175

106.171

106.172

106.173

106.174

106.180

106.181

37


Implants

Morse Taper

Product Characteristics • Cylindrical implant with Morse Taper interface; • NeoPoros Surface; • Pre-mounted; • Cover screw not included; • Optimization of primary stability; • Excellent alternative to posterior edentulous lower jaw; • Specific Surgical Kit; • Observe the specific Pilot Drill (same function of countersink drill); • In "M" Titamax WS Implant, the pilot drill is optional; • Perforation rotation: 200-300 rpm; • Insertion rotation: 30 rpm; • Unique Morse Taper prosthetic interface (same dimensions as CM Zygomatic Implants).

CM Pilot 5.3/6.0

Titamax Drill 5.3

CM Pilot 4.3/5.3

CM Pilot 4.3/5.0

Titamax Drill 4.3

CM Pilot 3.8/4.3

Titamax Drill 3.8

CM Pilot 3.3/4.0

CM Pilot 3/3.75

Titamax Drill 3.3

CM Pilot 2.8/3.5

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drill sequence

4.0 mm 5.0 mm 6.0 mm Optional for the "M" Implant

38


6.0 mm

5.0 mm

6.0 mm

109.578

109.579

109.580

109.581

Morse Taper

5.0 mm

Ø 5.0

Ø 4.0

109.604

109.605

Ø 5.0

Ø 6.0

109.574

109.575

Ø 6.0

109.576

109.577

CM Cover screw

117.016

Healings

WS

0.8 mm

1.5 mm

2.5 mm

3.5 mm

106.186

106.187

106.188

106.189

39


Prostetics Components

Demonstrative sequence of

CM Abutment and WS Abutment Morse Taper

Prosthetic Torque Ratchet Driver

Titanium

Castable

Tilite / CoCr

Torque Connection 1.2mm

GT Cylinder

GT Protective Cylinder

GT Analogue

GT Open Tray Transfer

GT Transfer

• Same prosthetic sequence as the GT Implant; • Available in Titanium; • Minimum interocclusal space of 5.0mm from the mucosa level;

Prosthetic Torque Ratchet Driver

• Conicity 15°; • Single screw retained prosthesis (anti-rotational); • The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.

Torque Connection 1.6 mm

32

N.cm CM Abutment

40

WS Abutment


115.162

115.147

115.148

115.152

115.163

115.164

WS Abutment

115.165

Tilite

CoCr

118.179

118.176

118.242

• Available: -Titanium: for provisional prosthesis; -Tilite and CoCr: overcastting; -Castable: casting. • With screw; • To screw torque, use Torque Connection 1.2mm (105.005); • Observe indicated torque; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Morse Taper

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 6.5 mm

Titanium

Demonstrative sequence of

CM Abutment

Castable 118.180

CM Abutment and WS Abutment

Anti-rotational

GT Cylinder

0.8 mm 1.5 mm 2.5 mm 3.5 mm 115.180

115.181

115.182

115.183

•Observe corresponding sequence and indicated torque; • Use Torque connection 1.6 mm (105.006); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

GT Protection Cylinder 106.102

• Available in Titanium; • Used to protect the component during the prosthesis construction; • To installation, use Digital Driver 1.2mm (104.007).

GT Analogue 101.037

• Available in Titanium; • Replica of implant platform or prosthetic component; • For prosthesis construction or prosthetic planning.

GT Transfer Open tray

Closed tray

108.039

108.040

• For transference and impression of prosthesis; • Available in Titanium; • For open tray or closed tray technique; • Anti-rotational.

GT Polishing Protector 123.012

• Protector for cylinders during polishing and finishing of prosthesis; • Use the corresponding screw to the cylinder for fixation.

GT Cylinder Screw Titanium

Neotorque

116.038

116.228

41


Prosthetics Components

Demonstrative sequence of

CM Mini Abutment and WS Mini Abutment Morse Taper Prosthetic Torque Rachet Driver

Titanium

Castable

Tilite / Gold / CoCr

Torque Connection 1.2mm

Mini Conical Abutment Cylinder

Protective Cylinder of Mini Conical Abutment

Mini Conical Abutment Analogue

Mini Conical Abutment Transfer

Prosthetic Torque Ratchet Driver

•Available in Titanium; • Minimum interocclusal space of 4.4mm from the mucosa level; • Multiple and screw retained prosthesis; • Conicality 20°; • The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw.

Connection to Conical Torque 4.1 mm

32

N.cm

42

Connection to Conical Torque 4.1 mm

32

N.cm

Connection to Torque 0.9 mm

15

N.cm

WS Mini

CM Mini Conical

Angled CM Mini Conical

Conical Abutment

Abutment

Abutment (17° and 30°)


0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 6.5 mm 115.154

115.149

115.150

115.151

115.153

115.160

115.161

115.167

115.168

30º

115.169

115.170

115.171

•Check measurements in “Technical Guidance”, on page 14.

•Observe corresponding sequence and indicated torque; •Observe indicated Torque Connection; •To control torque, use Prosthetic Torque Ratchet Driver (104.026); •Check the measurement of angled components in Catalog.

WS Mini Conical Abutment 0.8 mm 1.5 mm 2.5 mm 3.5 mm 115.176

115.177

115.178

115.179

Morse Taper

CM Mini Conical Abutment

115.166

Demonstrative sequence of

1.5 mm 2.5 mm 3.5 mm

17º

CM Mini Abutment and WS Mini Abutment

Angled CM Mini Conical Abutment

Cylinder of CM Mini Conical Abutment

ø4.1

Castable

Titanium

Tilite

Gold

CoCr

CoCr for weld

118.112

118.113

118.146

118.206

118.209

118.210

Protective Cylinder of Mini Conical Abutment ø4.1

•Available in: -Titanium: provisional prosthesis; -Tilite and CoCr: overcastting; -Castable: casting; -Gold: gold alloy with high melting range. •Rotational for screwed retained multiple elements; •With screw; •To screw torque, use Torque Connection 1.2mm (105.009) •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

106.054

•Available in Titanium; •Used to protect the component during the prosthesis construction; •To installation, use Digital Driver 1.2mm (104.007).

Transfer of Mini Conical Abutment Closed-tray

Cylinder Screw ø4.1

Titanium

Neotorque

116.037

106.227

ø4.1

108.021

Short screw

116.036

Open-tray 108.022

Multifunctional 108.068

•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray or closed tray technique; •Rotational.

Polishment Protector Analogue of Mini Conical Abutment ø4.1

101.020

ø4.1

123.008

•Protector for cylinders during polishing and finishing of prosthesis; •Use the corresponding screw to the cylinder for fixation.

•Available in Titanium; •Replica of prosthetic component; •For prosthesis construction or prosthetic planning.

43


Prosthetics Components

Demonstrative Sequence of

CM Micro Abutment Morse Taper

Prosthetic Torque Ratchet Driver

Titanium

CoCr

Torque Connection 1.2mm

Mini Conical Abutment Cylinder

Protective Cylinder of Mini Conical Abutment

Mini Conical Abutment Analogue

Mini Conical Abutment Transfer

•Available in Titanium; •Multiple and screwed prosthesis; •Indicated to CM Implants with diameter of 3.5mm

Prosthetic Torque Ratchet Driver

and close to each other; •Minimum interocclusal space of 4.4mm from the mucosa level; •The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw. Connection to Conical Torque

32

N.cm CM Micro Conical Abutment

44


1.5 mm 2.5 mm 3.5 mm 115.200

115.201

115.202

• Observe sequence and torque; • To torque, use Conical Torque Connection 4.1mm (105.009); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Castable

118.246

118.245

118.247

Morse Taper

CoCr

CM Micro Abutment

CM Micro Conical Abutment

Titanium

Demonstrative Sequence of

Micro Conical Abutment Cylinder

•Available in: -Titanium: provisional prosthesis; -CoCr: overcastting; -Castable: casting. •Rotational for screwed multiple elements; •With screw; •To screw torque, use Torque Connection 1.2mm (105.009) •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Cylinder Screw Titanium

Neotorque

116.037

106.227

Protective Cylinder of CM Micro Abutment

ø4.1

106.199

• Available in Titanium; • Used to protect the component during the prosthesis construction; • To installation, use Digital Driver 1.2mm (104.007).

Micro Conical Abutment Analogue 101.057

•Available in Titanium; •Replica of prosthetic component; •For prosthesis construction or prosthetic planning.

Open Tray Transfer of Micro Conical Abutment Rotational 108.070

•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray technique; •Rotational.

45


Prosthetics Components

Demonstrative Sequence of

CM Anatomic Post Morse Taper

Indicated Sequence

Optional Sequence Prosthesis Conclusion

Laboratorial Phase

Laboratorial Phase

Prosthetic Torque Ratchet Driver

Conventional Molding

Torque Connection 0.9 mm Customization

15

N.cm Prosthetic Torque Ratchet Driver

CM Anatomic Post

Analogue of CM Implant Torque Connection 0.9 mm

•Available in Zirconia, according to ASTM ISO 13.356;

15

N.cm

•Cemented unitary prosthesis; •Possible customization; •Indicated for aesthetic area.

46

CM Anatomic Post

CM Implant Transfer


1.5 mm 2.5 mm 3.5 mm Zirconia

114.321

114.322

114.323

•To installation, use Torque Connection 0.9mm (105.065); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Morse Taper

CM Anatomic Post

Demonstrative Sequence of

CM Lateral Anatomic Post

CM Anatomic Post

1.5 mm 2.5 mm 3.5 mm Zirconia

114.332

114.333

114.334

•Available in Zirconia; •Cemented prosthesis; •To installation, use Torque Connection 1.2mm (105.005); •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

CM Implant Analogue CM Implant Transfer 101.053 Long 108.041

Short 108.065

• Available in Titanium; • Component with molding function by prosthesis construction; • For closed tray technique.

•Available in Titanium; •Replica of prosthetic interface; •For prosthesis construction or prosthetic planning.

47


Prosthetics Components

Demonstrative Sequence of

CM Universal Post Morse Taper

Castable

Temporary

Aluminium

ø 4.5 Castable

Temporary

Aluminium

ø 3.3

Universal Post Cylinder

ø 3.3

ø 4.5

CM Post Analogue

ø 3.3

ø 4.5

CM Post Transfer

Prosthetic Torque Ratchet Driver

Torque Connection 1.2mm

•Cemented prosthesis; •Straight Universal Post in Titanium body;

32

N.cm

ø3.3 x 4

48

ø3.3 x 6

ø4.5 x 4

ø4.5 x 6


114.129

114.077

114.078

114.079

114.136

114.137

114.138

ø 3.3

114.131

114.080

114.081

114.082

114.142

114.143

114.144

114.130

114.086

114.087

114.088

114.139

114.140

114.141

ø 3.3

114.132

114.083

114.084

114.085

114.145

114.146

114.147

ø 4.5

• Available in Titanium; • Observe indicated torque and connection; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

ø 4.5

6 mm

30º

114.089

114.090

114.091

114.095

114.096

114.097

114.092

114.093

114.094

114.098

114.099

114.100

114.101

114.102

114.103

114.107

114.108

114.109

114.104

114.105

114.106

114.110

114.111

114.112

Morse Taper

ø 4.5

4 mm

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 6.5 mm

6 mm

ø 3.3

•See measurements in “Technical Guidance”.

Universal Post Transfer

ø 3.3

ø 3.3 ø 4.5

6 mm

ø 4.5

4 mm

ø 4.5 ø 3.3

108.042 108.044

ø 3.3 ø 4.5

108.045

ø 4.5

4 mm 6 mm

ø 3.3

Castable

Temporary

118.186

118.181

118.192

118.188

118.183

118.194

118.187

118.182

118.193

118.189

118.184

118.195

• Available in: -Titanium: provisional prosthesis; -Alumina: for “metal free” prosthesis; -Castable: casting. • Cemented prosthesis; • Compatible with all Universal Posts, if not prepared.

Universal Post Analogue

Universal Post Set

ø 4.5

Aluminum

108.043

• Available in polymer; • Component with molding function by prosthesis construction; • For closed tray technique; • Anti-rotational; • Select transfer according to the component to be molded, as prosthetic planning.

ø 3.3

4 mm

Universal Post Cylinder

6 mm

ø 4.5

ø 4.5

108.060 108.062 108.061 108.063

• Components Kit of Universal Post line, containing the Transfer and Provisional / Castable Cylinders.

ø 3.3 ø 4.5 ø 3.3 ø 4.5

4 mm

ø 3.3

17º

6 mm

ø 4.5

6 mm

ø 3.3

4 mm

CM Universal Post in Titanium

4 mm

ø 3.3

CM Universal Post

1.5 mm 2.5 mm 3.5 mm

Demonstrative Sequence of

Angled CM Universal Post in Titanium

101.038 101.040 101.039 101.041

• Available in Titanium; • Replica of prosthetic component platform; • For prosthesis construction and prosthetic planning.

49


Prosthetics Components

Demonstrative Sequence of

CM Universal Post Through Bolt Morse Taper

Prosthetic Torque Ratchet Driver

15

32

N.cm

N.cm

Torque Connection 0.9 mm

Torque Connection

CM Universal Post Through Bolt

WS Post

1.2mm

CM Implant

WS Implant

Analogue

Analogue

•Available in Titanium; •Cemented unitary prosthesis; •Need of Transfer Guide in acrylic resin •Indicated for laboratorial customization.

50

Transfer of Long CM Implant

Transfer of Short CM Implant

Transfer of WS Implant


ø 3.3

114.148

114.149

114.150

114.151

114.152

114.153

114.154

ø 4.5

114.115

114.117

114.118

114.119

114.162

114.163

114.164

ø 3.3

114.155

114.156

114.157

114.158

114.159

114.160

114.161

ø 4.5

114.116

114.120

114.121

114.122

114.165

114.166

Demonstrative Sequence of

6 mm

4 mm

0.8 mm 1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm 6.5 mm

114.167

Morse Taper

CM Universal Post Through Bolt

CM Universal Post Through Bolt

• Available in Titanium; • Component with through bolt; • Cemented prosthesis; • To installation, use Torque Connection 1.2mm (105.005); • Observe indicated torque; • Available in two heights: 4mm and 6mm.

Zirconia Universal Post Through Bolt

WS Universal Post 0.8 mm 1.5 mm 2.5 mm 3.5 mm

6 mm

114.293

ø 4.5

114.286

114.287

114.288

ø 3.3

114.300

114.301

114.302

ø 4.5

114.289

114.290

114.291

114.294

114.295

ø 4.5

•Available in Zirconia; •Component with through bolt; •Cemented prosthesis; •Use a Torque Connector of 0.9 mm (105.006); for installation; •Observe indicated torque; •Available in two heights 4mm and 6mm.

Analogue

4 mm

ø 3.3

114.183

114.184

114.185

114.186

6 mm

4 mm

1.5 mm 2.5 mm 3.5 mm

114.187

114.188

114.189

114.190

• Available in Titanium; • Two pieces; • Component with through bolt; • Cemented prosthesis; • To installation, use Torque Connection 1.2mm (105.005); • Observe indicated torque; • Available in two heights: 4mm and 6mm.

CM Implant Transfer

CM

WS

101.053

101.055

• Available in Titanium; • Replica of prosthetic interface; • For prosthetic planning.

Long

Short

WS

108.041

108.065

108.064

• Available in Titanium; • Component with molding function by prosthesis construction; • For closed tray technique.

51


Prosthetics Components

Demonstrative sequence of

Mini Ball Attachment Morse Taper

O’ring with Cylinder

Disc

Positioner

Positioner

Positioner

straight

14º

Prosthetic Torque Ratchet Driver

Conical Torque Connection 4.1 mm

Ball Attachment Installed

32

•Available in Titanium;

N.cm

•Directly over the implant; •For Overdenture prosthesis, its function is the O’ring retention; •It's recommended capture the components in patient's mouth, one by one; •Application of Nitride Titanium coating for increased the wear resistance; •O’ring with protection disc; •See the demonstrative sequence of Mini Ball Attachment on page 131.

52

CM Mini Ball Attachment


102.070

102.071

102.097

Castable Ball Attachment

102.098

•Available in Titanium; •Select according to the mucosa height; •To installation, use Torque Connection 1.2mm (105.005);

102.078

•Castable: casting in various metals; •May be cemented in natural roots or waxed in bars for overdenture retention.

Morse Taper

102.069

Mini Ball Attachment

1.5 mm 2.5 mm 3.5 mm 4.5 mm 5.5 mm

Demonstrative sequence of

CM Mini Ball Attachment

Positioners straight, 7º e 14º

102.076

•Available in polymer; •Indicated to define the correct distance between Attachment Ball components and O’ring with cylinder; •Corrects the parallelism between the implants; •Essential for O’ring capturing.

O’ring with cylinder 102.073

•Available in polymer; •Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; •Not Autoclavable.

O’ring O’ring Remover 102.075 104.044

•Digital Driver with function of O’ring replacing to the cylinder.

•Available in polymer; •Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; •Not Autoclavable.

Protection Disc O’ring Mount 104.043

•Digital Driver with function of O’ring replacing to the cylinder.

102.077

•Packaging with 10 units.

53


E x t e r n a l H e x

54


•Results in the integrity of the External Hex; •Maintains the original rotational freedom; •Greater practicality and safety; •Higher mechanical resistance to insertion; •Transport tweezers for safety in the handling of the implant.

.3 m

m

He x

2.

7

m

0.7 mm

Ø4

.1 m

m

m

Internal Thread Ø 1.8

Ø3

Internal Thread Ø 2.0

Hex 2.37 mm

1 mm

EXTERNAL HEX

Ø 3.3

m

1 mm

.3 m

m

Ø 4.1

.3

1 mm

Ø5

.0

mm

Ø 4.3

4.5 e 5.0 mm He x3

mm

Internal Thread Ø 2.5

Ø4

Internal Thread Ø 2.0

.7 m

Cemented Prosthesis

•Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17° (multiple) •Castable UCLA •Tilite UCLA •CoCr UCLA •Zirconia UCLA

•Angled Post 17° •Tilite UCLA •Castable UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA

•SF Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17° and 30° (multiple) •SF Conical Abutment (unitary) •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA •Zirconia UCLA •UCLA Zirconia with Titanium interface

•Angled Post 17°and 30° •Universal Post •Customized Post •Castable UCLA •Gold UCLA •Tilite UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA •SF Post

•Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17° and 30° (multiple) •Conical Abutment (unitary) •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA •Zirconia UCLA

•Angled Post 17° •Universal Post •Customized Post •Castable UCLA •Gold UCLA •Tilite UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA

Overdenture

Protocol

3.3 e 3.5 mm

3.75 e 4.0 mm He x2

Screwed Prosthesis

Ø 5.0

4.5 e 5.0 mm

•SF Mini Conical Abutment (multiple) •Angled Mini Conical Abutment 17° and 30° (multiple) •SF Conical Abutment (unitary) •Castable UCLA •Tilite UCLA •CoCr UCLA •Zirconia UCLA

•Angled Post 17° •Customized Post •Castable UCLA •Tilite UCLA •Titanium UCLA •CoCr UCLA •Zirconia UCLA

•Mini Ball Attachment •Clip Bar •Mini Conical Abutment •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA

•Mini Ball Attachment •Clip Bar •Mini Conical Abutment •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA

•Mini Ball Attachment •Clip Bar •Mini Conical Abutment •Castable UCLA •Gold UCLA •Tilite UCLA •CoCr UCLA

•Mini Conical Abutment •Angled Mini Conical Abutment 17° and 30° •Cylinder and Distal External Bar Passive Fitting Technique • Cylinder of Castable Mini Abutment • Cylinder of Titanium Mini Abutment • Cylinder of Brass Mini Abutment •Mini Conical Abutment •Angled Mini Conical •Abutment 17° and 30° •Cylinder and Distal External Bar Passive Fitting Technique • Cylinder of Castable Mini Abutment • Cylinder of Titanium Mini Abutment • Cylinder of Brass Mini Abutment •Mini Conical Abutment •Angled Mini Conical •Abutment 17° and 30° •Cylinder and Distal External Bar Passive Fitting Technique • Cylinder of Castable Mini Abutment • Cylinder of Titanium Mini Abutment • Cylinder of Brass Mini Abutment

55


Implants

Product Characteristics • Cylindrical implant with External Hex interface; • NeoPoros Surface; • Capture and installation with contra-angle or manual without mount use (reduction of surgical time); • Double thread (faster installation and less trauma); • High cutting capacity; • Suitable for bones type I and II; • Cover screw and mount not included; • Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; • Perforation rotation: 800-1200 rpm; • Installation rotation: 30 rpm;

3.75 mm 4.0 mm 4.5 mm 5.0 mm Optional

56

Countersink 5.0

Titamax Drill 4.3

Titamax Drill 3.8

Countersink 4.1

Pilot 3/3.75

Titamax Drill 3.3

Titamax Drill 3.15

Titamax Drill 3.0

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drilling sequence


7.0 mm

9.0 mm

11.0 mm

13.0 mm

15.0 mm

109.284

109.285

109.286

109.287

109.288

109.302

109.303

109.304

109.305

109.306

109.327

109.328

109.329

109.295

109.296

17.0 mm

Ø 3.75 Platform (4.1)

Ø 4.0

Platform (4.1)

Ø 4.5 Platform (5.0)

Ø 5.0

109.294

109.297

Cover screw 4.1 mm

5.0 mm

117.018

117.003

Divergent Healings

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.092

106.093

106.094

106.095

Ø 5.0

106.127

106.128

106.129

106.130

2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.084

106.085

106.086

106.087

Ø 5.0

106.097

106.098

106.099

106.100

Slim Fit Healings 2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.190

106.191

106.192

106.193

Ø 5.0

106.195

106.196

106.197

106.198

57


Implants

Internal Torque

Product Characteristics •Cylindrical implant with External Hex interface; • NeoPoros Surface; • Capture and installation with contra-angle or manual without mount use (reduction of surgical time); • Double thread (faster installation and less trauma); • High compaction capacity (bone expansion); • Suitable for bones type III and IV; • Cover screw not included; • Simplified instrumentation in the prepare of surgical alveolus; • Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; • Prosthetic platform 4.1mm; • Perforation rotation: 800-1200 rpm; • Installation rotation: 30 rpm;

Countersink 5.0

Titamax Drill 4.3

Titamax Drill 3.8

Countersink 4.1

Pilot 3/3.75

Titamax Drill 3.3

Titamax Drill 3.0

Titamax Drill 2.8

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drilling sequence

3.75 mm 4.0 mm Optional

58


11.0 mm

13.0 mm

15.0 mm

17.0 mm

19.0 mm

109.582

109.583

109.584

109.585

109.586

109.587

109.588

109.589

109.590

109.591

109.592

Internal Torque

9.0 mm

Ø 3.75 Platform (4.1)

Ø 4.0

Platform (4.1)

109.593

Cover screw 4.1 mm 117.018

Divergent Healings

Ø 4.1

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.092

106.093

106.094

106.095

Ø 4.1

2.0 mm

3.0 mm

4.0 mm

5..0 mm

106.084

106.085

106.086

106.087

Slim Fit Healings

Ø 4.1

2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.190

106.191

106.192

106.193

59


Implants

Product Characteristics •Cylindrical implant with External Hex interface; • NeoPoros Surface; • Capture and installation with contra-angle or manual without mount use (reduction of surgical time); • Double thread (faster installation and less trauma); • High compaction capacity (bone expansion); • Suitable for bones type III and IV; • Cover screw not included; • Simplified instrumentation in the prepare of surgical alveolus; • Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; • Prosthetic platform 4.1mm; • Perforation rotation: 800-1200 rpm; • Installation rotation: 30 rpm;

3.75 mm 4.0 mm 5.0 mm Optional

60

Countersink 5.0

Titamax Drill 4.3

Titamax Drill 3.8

Countersink 4.1

Pilot 3/3.75

Titamax Drill 3.3

Titamax Drill 3.0

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drilling sequence


7.0 mm

9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.289

109.290

109.291

109.292

109.293

109.311

109.312

109.313

109.314

109.315

109.299

109.300

Ø 3.75 Plataforma (4.1)

Ø 4.0

Plataforma (4.1)

Ø 5.0

109.298

109.301

Cover screw 4.1 mm

5.0 mm

117.018

117.003

Divergent Healings

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.092

106.093

106.094

106.095

Ø 5.0

106.127

106.128

106.129

106.130

2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.084

106.085

106.086

106.087

Ø 5.0

106.097

106.098

106.099

106.100

Slim Fit Healings 2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.190

106.191

106.192

106.193

Ø 5.0

106.195

106.196

106.197

106.198

61


Implants

Product Characteristics •Conical implant with External Hex interface; • NeoPoros Surface; • Capture and installation with contra-angle or manual without mount use (reduction of surgical time); • Suitable for bones type III and IV and pos-extracting installation; • Cover screw and mount not included; • Simplified instrumentation in the prepare of surgical alveolus; • Installation through implant internal hex, increasing the mechanical resistance (when applied elevated torque), preserving the external hex integrity; • External Hex with height of 1mm: platform 4.3 and 5.0;

Countersink 5.0

Alvim Drill 5.0

Countersink 4.3

Alvim Drill 4.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drilling sequence

4.3 mm 5.0 mm

Optional

62


10.0 mm

13.0 mm

16.0 mm

109.321

109.322

109.323

109.324

109.325

109.326

Ø 4.3

Ø 5.0

Cover screw 4.3 mm

5.0 mm

117.018

117.003

Divergent Healings

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.092

106.093

106.094

106.095

Ø 5.0

106.127

106.128

106.129

106.130

2.0 mm

3.0 mm

4.0 mm

5.0 mm

Ø 4.1

106.084

106.085

106.086

106.087

Ø 5.0

106.097

106.098

106.099

106.100

Slim Fit Healings

Ø 5.0

2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.195

106.196

106.197

106.198

63


Implants

with Mount

Product Characteristics •Cylindrical implant with External Hex; • NeoPoros Surface; • Cover screw not included; • Double thread (faster installation and less trauma); • High cutting capacity; • Suitable for bones type I and II in reduced prosthetic spaces (upper lateral incisor and lower incisor); • Prosthetic platform 3.3mm; • External Hex with height of 1mm; • Resistance to the installation torque : 45 N.cm; • Perforation rotation: 500-800 rpm; • Installation rotation: 30 rpm;

3.3 mm

64

Countersink 3.3

Titamax Drill 2.8

Titamax Drill 2.0

Initial Drill

Drilling sequence


with Mount 9.0 mm

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.140

109.141

109.142

109.143

109.144

Ø 3.3

Cover screw 3.3 mm 117.001

Divergent Healings

Ø 3.3

Parallel Healings

2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.065

106.066

106.067

106.068

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.060

106.061

106.062

106.063

65


Implants

with Mount

Product Characteristics •Conical implant with External Hex; • NeoPoros Surface; • Cover screw included; • Suitable for bones type III and IV in reduced prosthetic spaces (upper lateral incisor and lower incisor) and pos-extracting installation; • Prosthetic platform 3.3mm; • External Hex with height of 1mm; • Resistance to the installation torque : 45 N.cm; • Perforation rotation: 500-800 rpm; • Installation rotation: 30 rpm;

Countersink 3.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drilling sequence

3.5 mm Optional

66


with Mount 10.0 mm

13.0 mm

16.0 mm

109.217

109.218

109.219

Ø 3.5 Platform (3.3)

Cover screw 3.3 mm 117.001

Parallel Healings

Divergent Healings

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.065

106.066

106.067

106.068

Ø 3.3

2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.060

106.061

106.062

106.063

67


Prosthetics Components

Demonstrative sequence of

SF Conical Abutment External Hex

Prosthetic Torque Ratchet Driver

Conical Mini Abutment 4.1 Cylinder

Castable

Titanium

CoCr/Tilite

Castable

Titanium

CoCr/Tilite

Torque Connection 1.2

Conical Mini Abutment 5.0 Cylinder

Conical Mini Abutment Protection 4.1 Cylinder

Conical Mini Abutment Protection 5.0 Cylinder

Conical Mini Abutment 4.1 Analogue

Conical Mini Abutment 5.0 Analogue

Conical Micro Abutment 4.1 Transfer Sequence 4.1 / 4.3 mm

Conical Micro Abutment 5.0 Transfer Sequence 5.0 mm

Prosthetic Torque Ratchet Driver

•Available in Titanium; • Minimum interocclusal space of 6.1mm on platform 4.1, and 6.7mm on platform 5.0mm, from the mucosa level; • Conicality 15°; • Single screwed prosthesis (anti-rotational); • Cylinders with screw; • Slim Fit components, that minimize bone remotion of the Countersink Drill, facilitating the intermediate seating and

Conical Torque Connection 4.1 mm

Conical Torque Connection 4.1 mm

the tissue accommodation.

20

N.cm

Conical SF Abutment

68

Conical Abutment 4.3 mm

Conical Abutment 5.0 mm


Ø 4.1

115.192

115.193

115.194

Ø 4.3

115.051

115.052

115.053

Ø 5.0

115.007

115.008

115.009

•Observe corresponding sequence to the component diameter and indicated torque; • For torque, use Conical Torque Connection 4.1mm (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Conical Abutment Cylinder Castable

Titanium

Ø 4.1

118.106

118.107

118.140

Ø 5.0

118.110

118.111

118.142

Tilite

CoCr 118.233

•Anti-rotational for screwed unitary elements; • Observe the corresponding sequence to the component diameter; • Screw included; • To screw torque, use Torque Conection 1.2mm (105.005); • Observe indicated torque; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

External Hex

3 mm

SF Conical Abutment

2 mm

Demonstrative sequence of

1 mm

Antirotational

Slim Fit

SF Conical Abutment

Antirotational

Conical Abutment Transfer Open-tray

Ø 4.1

108.035

Ø 5.0

108.025

Closed-tray 108.075

•Component with molding function by prosthesis construction; • Available in Titanium; • For open tray technique; • Anti-rotational; • Select transfer according to the component to be molded, as prosthetic planning.

Polishing Protector of Conical Abutment

Ø 4.1

123.013

Ø 5.0

123.014

Protection Cylinder of Conical Abutment

Ø 4.1

106.051

Ø 5.0

106.052

•Available in Titanium; • Used to protect the component during the prosthesis construction; • Observe the compatible diameter with the prosthetic component; • To installation, use Digital Driver 1.2mm (104.007).

•Protector for cylinders during polishing and finishing of prosthesis; • Use the corresponding screw to the component for fixation.

Anti-rotational Analogue of Conical Abutment

Cylinder Screw of Conical Abutmentt

Neotorque

Titanium

Neotorque

Ø 4.1

116.004

116.231

Ø 5.0

116.005

116.232

Ø 4.1 Ø 5.0

101.027 101.030

• Available in Titanium; • Replica of prosthetic component platform; • For prosthesis construction or prosthetic planning.

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

69


Prosthetics Components

Demonstrative sequence of

SF Conical Mini Abutment External Hex Prosthetic Torque Ratchet Driver

Conical Mini Abutment 4.1 Cylinder

Castable

Titanium

Gold / CoCr / Tilite

Castable

Titanium

Gold / CoCr / Tilite

Torque Connection 1.2

Conical Mini Abutment 5.0 Cylinder

Protection Cylinder of the Conical Mini Abutment 4.1

Protection Cylinder of the Conical Mini Abutment 5.0

Mini Conical Abutment Analogue 4.1

Mini Conical Abutment Analogue 5.0

Micro Conical Abutment Transfer 5.0

Micro Conical Abutment Transfer 4.1 Sequence 3.3 / 4.1 / 4.3 mm

Sequence 5.0 mm

Prosthetic Torque Ratchet Driver

•Available in Titanium; • Minimum interocclusal space of 4.4mm on platform 4.1, and 4.8mm on platform 5.0mm, from the mucosa level; • Screwed and multiple prosthesis (rotational); • Conicality 20°; • Mini Conical Abutment presents 12 positions of fitting; • The cylinders come with Neotorque screw, except the castables, that comes with Titanium screw. • Slim Fit components, that minimize bone remotion of the

Torque Connection 1.2 mm

20

N.cm

Countersink Drill, facilitating the intermediate seating and

Conical Torque Connection 4.1 mm

32

Torque Connection 1.6 mm

32

N.cm

N.cm

SF Mini Conical Abutment 4.1 mm

SF Mini Conical Abutment 5.0 mm

the tissue accommodation. Angled Mini Abutment 17º e 30º

70


Ø 4.1

115.187

Ø 4.3

115.054

Ø 5.0

115.197

3 mm

115.188

115.055

115.198

115.189

115.056

4 mm 115.190

115.057

2 mm

3 mm

4 mm

Ø 4.1

115.084

115.074

115.075

Ø 4.3

115.076

115.077

115.078

5 mm 115.191

17º

Ø 5.0

115.058

115.199

30º

•Observe corresponding sequence to the component diameter and indicated torque; • Observe indicated torque; • For torque, use Conical Torque Connection 4.1mm (105.009), except for Ø 5.0 Torque Connection 1.6mm (105.006); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

115.095

115.096

Ø 4.1

115.140

115.141

115.142

Ø 4.3

115.111

115.112

115.113

Ø 5.0

115.143

115.144

115.145

•Minimum interocclusal space of 4.4mm on platform 4.1, and 4.8mm on platform 5.0mm, from the mucosa level; • Screwed and multiple prosthesis (rotational); • Observe corresponding sequence to the component diameter; • Observe indicated torque; • For torque, use Torque Connection 1.2 (105.005); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Protection Cylinder of Mini Conical Abutment

Cylinder of Mini Conical Abutment Castable

Titanium

115.094

5 mm

External Hex

2 mm

SF Conical Mini Abutment

Slim Fit

Slim Fit

1 mm

Demonstrative sequence of

Angled Mini Conical Abutment

SF Mini Conical Abutment

Gold

Tilite

Ø 4.1

118.112

118.113

118.146

Ø 5.0

118.114

118.115

118.147

118.206

CoCr

CoCr Para solda

118.209

118.210

Ø 4.1

106.054

Ø 5.0

106.055

118.240

•Rotational for screwed multiple elements; • Observe corresponding sequence to the component diameter; • To screw torque, use Torque Connection 1.2mm (105.005) • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

•Available in Titanium; •Used to protect the component during the prosthesis elaboration; •Observe the compatible diametre with the prosthetic component; •Use the Digital Driver 1.2mm (104.007) for installation.

Mini Conical Abutment Transfer

Polishing Protector of Mini Conical Abutment

Closed-tray

Open-tray 108.022 108.024

Ø 4.1

123.008

Ø 4.1

108.021

Ø 5.0

123.009

Ø 5.0

108.023

Short screw

116.036

•Protector for cylinders during polishing and finishing of prosthesis; • Use the corresponding screw to the component for fixation.

Multifunctional 108.068

•Component with moulding function for the making of the prosthesis; •Available in Titanium; •For the open-tray technique (drag); •Rotational; •Select the transfer in accordance with the component to be moulded conforming to the planned prosthetics.

Cylinder Screw of Mini Conical Abutment

Neotorque

Titanium

Neotorque

Ø 4.1

116.037

116.227

Ø 5.0

116.038

116.228

•Application of a thin carbon-based film which promotes reduced friction resulting in an increase in the preload.

Analogue of Mini Conical Abutment Ø 4.1

101.020

Ø 5.0

101.022

•Available in Titanium; •Replication of the prosthetic component; •For the making of the prosthesis and/or prosthetic planning.

71


Prosthetics Components

Demonstrative sequence of

Universal Post External Hex

Ø4.5

Ø4.5

Universal Post Cylinder

Universal Post Cylinder

Universal Post Cylinder

Aluminum

Temporary

Castable

Ø4.5

Ø4.5

Universal Post Analogue

Ø4.5

Universal Post Transfer

Prosthetic Torque Ratchet Driver

4.5

Torque Connection 1.2

4 ou 6 1, 2 ou 3 mm

32

3.8

N.cm Neotorque Screw

• Available in Titanium; • Cemented prosthesis; • The Universal Post can be prepared according to circunstances, and, in this case, the prosthetic sequence can not be used; • Compatible with platform 4.1 and 4.3 External Hex; • Screw not included; • Available in two heights: 4mm and 6mm

72

Universal Post


114.178

114.179

Ø 4.5 114.180

114.181

108.044

108.045

114.182

External Hex

114.177

Universal Post Transfer

Universal Post

3 mm

Demonstrative sequence of

2 mm

4 mm

1 mm

6 mm

6 mm

Ø 4.5

4 mm

Universal Post

• Component with molding function by prosthesis construction; • Available in polymer; • For closed tray technique; • Anti-rotational; • Select transfer according to the component to be molded, as prosthetic planning.

Cylinder of Universal Post

6 mm

Castable

Temporary

118.188

118.183

118.194

118.189

118.184

118.195

• Available in: Provisional: for provisional prosthesis; Alumina: for “metal free” prosthesis; Castable: casting. • Cemented prosthesis; • Compatible with all Universal Posts, when not prepared.

Universal Post Screw

Ø 4.1 Ø 4.3 Neotorque

Neotorque

Titanium

116.180

116.002

• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Universal Post Analogue

108.062

108.063

• Components Kit of Universal Post line, containing the Transfer and Provisional / Castable Cylinders.

Ø 4.5

4 mm

6 mm

Ø 4.5

4 mm

Universal Post Set

6 mm

Ø 4.5

4 mm

Aluminium

101.040

101.041

• Available in Titanium; • Replica of prosthetic component; • For prosthesis construction and/or prosthetic planning.

73


Post

Prosthetic Components

Demonstrative sequence of

External Hex

Prosthetic Torque Ratchet Driver

Torque Connection 1.2

32

32

32

32

N.cm

N.cm

N.cm

N.cm

Neotorque Screw

Neotorque Screw

Neotorque Screw

Titanium Screw

Slim Fit Post 4.1 mm

Personalised Post 4.1 mm

Personalised Post 5.0 mm

Angled Post (17º e 30º) 3.3/ 4.1/ 4.3 / 5.0 mm

Implant Analogue

Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0

Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0

Conical Transfer 3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

Dragl Transfer 3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

• Available in Titanium; • Cemented prosthesis; • Angled Post presents 12 positions of fitting; • Customizable Post without screw. It is recommended to use the Neotorque screw; • Slim Fit components, that minimize bone remotion of the Countersink Drill, facilitating the intermediate seating and the tissue accommodation.

74


Ø 4.1

Rotational

114.237

114.236

Customizable Post

•To installation, use Torque Connection 1.2mm (105.005); •To unitary elements, select Neotorque Screw; •Screw not included; •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Ø 4.1 for ø 5.0

114.029

Ø 4.1 for ø 6.0

114.030

Ø 5.0 for ø 6.0

114.035

External Hex

Post

Antirotational

Demonstrative sequence of

Slim Fit Post

•Available in Titanium; •Cemented prosthesis; •To installation, use Torque Connection 1.2mm (105.005); •To unitary elements, select Neotorque Screw; •Screw not included; •Observe indicated torque; •To torque control, use Prosthetic Torque Ratchet Driver (104.026). •Available to platform 4.1, 4.3 and 5.0 .

Angled Post

30º

3 mm

4 mm

Ø 3.3

114.025

114.026

114.027

Ø 4.1

114.016

114.017

114.018

Ø 4.3

114.049

114.050

114.051

Ø 5.0

114.071

114.072

114.073

114.009

114.010

Ø 4.1

5 mm

Implant Transfer Closed-tray

114.011

Rotational

•Anti-rotational •Titanium screw included; •Observe indicated torque; •To torque, use Torque Connection 1.2mm (105.005); •To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Antirotational

17º

2 mm

Implant Analogue Titanium

Brass

Ø 3.3

101.002

101.001

Ø 4.1

101.004

101.003

Ø 4.3

101.028

101.024

Ø 5.0

101.006

101.005

Open-tray

Ø 3.3

108.001

108.006

Ø 4.1

108.003

108.067

Ø 4.3

108.029

108.034

Ø 5.0

108.013

108.011

Ø 3.3

108.002

Ø 4.1

108.066

Ø 4.3

108.038

Ø 5.0

108.012

•Component with molding function by prosthesis construction; •Available in Titanium; •Select transfer according to the implant to be molded, as prosthetic planning.

Post Screw

Ø 3.3

Neotorque

Titanium

116.188

116.001

116.180

116.002

116.189

116.003

Ø 4.1 •Available in Brass and Titanium; •Replica of implant platform; •For prosthesis construction and/or prosthetic planning.

Ø 4.3 Ø 5.0

Neotorque

• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

75


Componentes Protéticos

Demonstrative sequence of

UCLA External Hex

Prosthetic Torque Ratchet Driver

Torque Connection 1.2

32

N.cm Neotorque Screw

UCLA 3.3 mm

UCLA 4.1 mm

UCLA 4.3 mm

UCLA 5.0 mm

Analogue 3.3 mm

Analogue 4.1 mm

Analogue 4.3 mm

Analogue 5.0 mm

• Prosthetic component directly over the implant hex; • For screwed or cemented prosthesis; • Available in Rotational or Anti-Rotational; - Tilite and CoCr: overcastting; - Castable: casting; - Titanium: Provisional or Cemented Prosthesis

Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0

Ø3.3 / Ø4.1 / Ø4.3 / Ø5.0

- Gold: Overcasting with high melting range leagues. With Titanium and Neotorque screw; • Observe presentation with screw; • For unitary elements, select Neotorque screw.

76

Closed-tray Transfer

Open-tray Transfer

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm

3.3 mm / 4.1 mm / 4.3 mm / 5.0 mm


118.079

118.001

118.008

118.121

118.004

118.009

118.027

118.101

118.097

118.243

118.040

118.219

Ø 4.1

Zirconia with Titanium belt

118.215 118.204

118.217

118.244

External Hex

Zirconia

118.212

Titanium

UCLA

Antirotational

Gold

Tilite

Ø 3.3

Rotational

Castable

Cobalt-Chrome (Cocr)

SDemonstrative sequence of

UCLA

118.235

Ø 4.3 Ø 5.0

118.237

118.029

118.006

Ø 3.3

118.211

118.078

118.002

118.120

118.005

118.030

118.026

118.119

118.152

118.028

118.007

Ø 4.1

118.205

118.234

Ø 4.3 Ø 5.0

118.236

•Zirconia Line with and without a Titanium base.

UCLA Screw

Ø 3.3

Implant Transfer

Rotational

Antirotational

Closed-tray

Ø 3.3

108.006

Ø 4.1

108.003

108.067

Ø 4.3

108.029

108.034

Ø 5.0

108.013

108.011

Ø 3.3

108.002

Ø 4.1

108.066

Ø 4.3

108.038

Ø 5.0

108.012

Ø 4.3 Ø 5.0

Neotorque

Polishing Protector

Ø 4.1

123.003

Ø 4.3

123.004

Ø 5.0

123.005

116.188

116.001

116.180

116.002

116.189

116.003

• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

•Component with molding function by prosthesis construction; •Available in Titanium; •Select transfer according to the implant to be molded, as prosthetic planning.

123.002

Titanium

Ø 4.1 Open-tray

108.001

Ø 3.3

Neotorque

Implant Analogue Titanium

Brass

Ø 3.3

101.002

101.001

Ø 4.1

101.004

101.003

Ø 4.3

101.028

101.024

Ø 5.0

101.006

101.005

•Available in Brass and Titanium; •Replica of implant platform; •For prosthesis construction or prosthetic planning.

• Protector for cylinders during polishing and finishing of prosthesis; • Use the corresponding screw to the component for fixation.

77


Prosthetic Components

Demonstrative sequence of

Mini Ball Attachment External Hex

O’ring with cylinder

Protection Disc

Positioner straight

Positioner 7º

Positioner 14º

Prosthetic Torque Ratchet Driver

Conical Torque Connection 4.1

32

Installed Ball Attachment

N.cm Mini Ball Attachment 4.1

• Available in Titanium; • Directly over the implant; • It´s recommended capture the components in patient’s mouth, one by one; • O’ring with protection disc; • Application of Nitride Titanium coating for increased the wear resistance; • See the demonstrative sequence of Mini Ball Attachment on page 131.

78

Mini Ball Attachment 4.3

Mini Ball Attachment 5.0


4 mm

5 mm

Ø 4.1

102.060

102.061

102.062

102.093

Ø 4.3

102.063

102.064

102.065

102.094

Ø 5.0

102.066

102.067

102.068

102.095

• To installation, use Conical Torque Connection 4.1mm (105.009); • Observe indicated torque; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Castable Attachment Ball 102.078

•Castable: casting in various metals; •May be cemented in natural roots or waxed in bars for overdenture retention.

External Hex

3 mm

Mini Ball Attachment

2 mm

Demonstrative sequence of

Mini Ball Attachment

Positioners straignt, 7º e 14º

102.076

•Available in polymer; •Indicated to define the correct distance between Attachment Ball components and O’ring with cylinder; •Corrects the parallelism between implants; •Essential for O’ring capturing.

O’ring with cylinder 102.073

• Available in Titanium (cylinder); • Available in polymer (O’ring); • Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; • Not autoclavable.

O’ring O’ring Remover 104.044

• Digital Driver with function of O’ring replacing to the cylinder.

102.075

• Available in polymer (O’ring); • Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; • Not autoclavable.

Protection Disk 102.077

O’ring Mount

• Package with 10 units.

104.043

• Digital Driver with function of O’ring placement to the cylinder.

79


I n t e r n a l

80

H e x


•Prosthetic components with reduced platform in relation to the implant (Switching Platform); •Installation driver with tweezers to increase the transport security and the implant placement; •Cervical microretentions to bone tissue maintenance; •Unique prosthetic sequence independent of the implant platform diameter.

INTERNAL HEX

2.6

Pla

tfo

rm

Di

am

et

er

mm

Implant Diameter

Internal Thread Ø 1.6

HE X 2.5 AGO mm N

3.75, 4.3 e 5.0 mm

Prosthetic Platform Diameter

4.3 e 5.0 mm

Screwed Prosthesis • Mini Conical Abutment II Plus (multiple); • UCLA Tilite II Plus (unitary); • UCLA CoCr II Plus (unitary); • UCLA Zirconia II Plus • Conical Abutment II Plus

Cemented Prosthesis • Universal Post II Plus • Angled Post II Plus 17° and 30° • UCLA Tilite II Plus • UCLA CoCr II Plus (unitary) • UCLA Zirconia II Plus

Overdenture

Protocol

•Mini Ball Attachment II Plus •Clip Bar • Mini Conical Abutment II Plus • UCLA Tilite II Plus • UCLA CoCr II Plus (unitary).

• Mini Conical Abutment II Plus; • Cylinder and Distal External Bar. Passive Fitting Technique • Cylinder - Castable Mini Abutment • Cylinder – Titanium Mini Abutment • Cylinder – Brass Mini Abutment

81


Implants

Product Characteristics • Cylindrical implant with Internal Hex interface; • NeoPoros Surface; • Double thread (faster installation and less trauma); • High cutting capacity; • Suitable for bones type I and II; • Cover screw not included; • Unique prosthetic interface for all implant diameters; • Perforation rotation: 800-1200 rpm; • Installation rotation: 30 rpm;

Prosthetic Components with

5.0

reduced platform in relation 3.8

to the implant (Switching Platform).

Countersink II 5.0

Titamax Drill 4.3

Titamax Drill 3.8

Countersink II 4.3

Pilot 3/3.75

Titamax Drill 3.15

Titamax Drill 3.0

Pilot 2/3

Titamax Drill 2.0

Initial Drill

Drill sequence

3.75 mm 5.0 mm Optional

82


7.0 mm

9.0 mm

11.0 mm

13.0 mm

15.0 mm

109.462

109.463

109.464

109.465

109.466

(4.3) Ø 3.75

Ø 5.0

109.474

109.475

109.476

109.477

Cover screw

117.014

Healings 2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.176

106.177

106.178

106.179

83


Implants

Product Characteristics: • Conical implant with Internal Hex interface; • NeoPoros Surface; • Suitable for bones type III and IV and pos-extracting installation; • Cover screw not included; • Unique prosthetic interface for all implant diameters; • Perforation rotation: 500-800 rpm; • Installation rotation: 30 rpm;

Prosthetic Components with

5.0

reduced platform in relation 3.8

to the implant (Switching Platform).

Countersink II 5.0

Broca Alvim 5.0

Countersink II 4.3

Alvim Drill 4.3

Alvim Drill 3.5

Alvim Drill 2.0

Initial Drill

Drill sequence

4.3 mm 5.0 mm Optional

84


10.0 mm

13.0 mm

16.0 mm

Ø 4.3 109.478

109.479

109.481

109.482

109.480

Ø 5.0 109.483

Cover screw

117.014

Healings 2.0 mm

3.0 mm

4.0 mm

5.0 mm

106.176

106.177

106.178

106.179

85


Prosthetic Components

Demonstrative Sequence of

Conical Abutment II Plus Internal Hex

Prosthetic Torque Ratchet Driver

Castable

Titanium

Tilite / CoCr

Torque Connection 1.2mm

Conical Abutment Cylinder 4.1

Protection Cylinder of Conical Mini Abutment 4.1

Conical Abutment Analogue 4.1

Conical Abutment Transfer 4.1

•Available in Titanium;

Prosthetic Torque Ratchet Driver

• Minimum interocclusal space of 6.1mm from the mucosa level; • Conicality 15°; • Single screwed prosthesis (anti-rotational); • Concept Switching Platform; • Compatible components with implants diameter (Ø 3.75,

Conical Torque Connection 4.1 mm

Ø 4.3 and Ø 5.0); • The cylinders come with Neotorque screw, except the

20

castables, that comes with Titanium screw.

N.cm Conical Abutment II Plus

86


115.185

115.203

115.186

• For torque, use Conical Torque Connection 4.1mm; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Protection Cylinder of Conical Abutment ø4.1

Titanium

Tilite

CoCr

118.106

118.107

118.140

118.233

118.104

118.105

118.139

118.232

• Available in Titanium; • Used to protect the component during the prosthesis construction; • Observe the compatible diameter with the prosthetic component; • To installation, use Digital Driver 1.2mm (104.007).

Conical Abutment Transfer

•Available: -Titanium: Provisional prosthesis; -Tilite and CoCr: Overcasting; -Castable: Casting. •Anti-rotational for unitary screwed elements; • Screw included; • To screw torque, use Torque Connection 1.2mm (105.005); • Observe indicated torque; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Open tray

Closed tray

Anti-rotational

Castable

106.051

108.035

108.075

Rotational

Anti-rotational

Abutment II Plus

Rotational

115.205

• To torque, use Conical Torque Connection 4.1mm; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Cylinder of Conical

ø4.1

115.204

Internal Hex

115.184

Demonstrative sequence of

2.0 mm 3.0 mm 4.0 mm

1.0 mm 2.0 mm 3.0 mm

Conical Abutment II Plus

Angled Conical Abutment II Plus 17°

Conical Abutment II Plus

108.020

108.018

ø4.1

Conical Abutment Analogue ø4.1

101.027

• Available in Brass and Titanium; • Replica of implant platform or prosthetic component; • For prosthesis construction or prosthetic planning.

• Component with molding function by prosthesis construction; • Available in Titanium; • For open tray or closed tray technique; • Rotational and Anti-rotational; • Select transfer according to the component to be molded, as prosthetic planning.

Cylinder Screw of Conical Abutment

Polishing Protector of Conical Abutment ø4.1

123.013

•Protector for cylinders during polishing and finishing of prosthesis; •Use the corresponding screw to the component fixation.

Neotorque

Titanium

Neotorque

116.004

116.231

• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

87


Prosthetic Components

Demonstrative Sequence of

Mini Conical Abutment II Plus Internal Hex

Prosthetic Torque Ratchet Driver

Titanium

Castable

Gold / Tilite / CoCr

Torque Connection 1.2mm

Mini Conical Abutment Cylinder

Protection Cylinder of Mini Conical Abutment

Mini Conical Abutment Analogue

Multifunctional Mini Conical Abutment Transfer

Mini Conical Abutment Transfer

• Available in Titanium;

Prosthetic Torque Ratchet Driver

• Minimum interocclusal space of 4.4mm from the mucosa level; • Screwed and multiple prosthesis (rotational); • Conicality 20°; • Concept Switching Platform; • Compatible component with implants diameter II Plus (Ø 3.75, Ø 4.3 and Ø 5.0); • The cylinders come with Neotorque screw, except the

Conical Torque Connection 4.1 mm

castables, that comes with Titanium screw.

20

N.cm

Mini Conical Abutment II Plus

88


2 mm

3 mm

4 mm

5 mm

Conical Abutment

115.155

115.156

115.157

115.158

115.159

Castable

Titanium

118.112

118.113

• Observe indicated torque; • To torque, use Conical Torque Connection 4.1mm (105.009); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Ø 4.1

Tilite

Gold

CoCr

118.146

118.063

118.209

CoCr for welding

118.210

•Available in: -Titanium: prosthesis; -Tilite and CoCr: overcastting; -Castable: casting; -Gold alloy: overcastting with high melting range leagues. • Titanium and Neotorque screws included; • Rotational for screwed multiple elements; • To screw torque, use Torque Connection 1.2mm (105.005); • Observe indicated torque; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Internal Hex

1 mm

Conical Mini Abutment II Plus

Cylinder of Mini

Demonstrative Sequence of

Mini Conical Abutment II Plus

Mini Conical Abutment Analogue Ø 4.1

101.020

Protection Cylinder of Mini Conical Abutment

• Available in Titanium; • Replica of prosthetic component platform; • For prosthesis construction and prosthetic planning.

Ø 4.1

Polishing Protector of Mini Conical Abutment Ø 4.1

106.054

• Available in Titanium; • Used to protect the component during the prosthesis construction; • Observe the compatible diameter with the prosthetic component; • To installation, use Digital Driver 1.2mm (104.007).

123.008

• Protector for cylinders during polishing and finishing of prosthesis; • Use the corresponding screw to the component for fixation.

Mini Conical Abutment Transfer Closed tray

Cylinder Screw of Mini Conical Abutment Ø 4.1

Neotorque

Titanium

Neotorque

116.037

116.227

ø4.1

108.021

Screw Short

116.036

Open tray 108.022

Multifunctional 108.068

•Available in Titanium; •Component with molding function by prosthesis construction; •For open tray or closed tray technique; •Rotational;

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

89


Prosthetic Components

Demonstrative sequence of

Universal Post II Plus Internal Hex Ø4.5

Ø4.5

Ø4.5

Universal Post Cylinder

Universal Post Cylinder

Universal Post Cylinder

Aluminium

Provisional

Castable

Ø4.5

Universal Post Analogue

Ø4.5

Universal Post Transfer

Prosthetic Torque Ratchet Driver

ø4.5

4 ou 6

Transmucous Torque Connection 1.2

ø3.8

Neotorque Screw

•Available in Titanium; •Cemented prosthesis; •Screw not included;

20

•The Universal Post can be prepared according to circunstances, and, in this case, the prosthetic sequence can not be used; •Compatible component with implants diameter II Plus (Ø 3.75, Ø 4.3 and Ø 5.0);

90

N.cm Universal Post high 4.0 mm

Universal Post high 6.0 mm


114.126

114.127

114.128

• To installation, use Torque Connection 1.2mm (105.005); • For unitary elements, select Neotorque screw. • Observe indicated torque; • To torque control, use Prosthetic Torque Ratchet Driver (104.026). • Available in two heights of cemented area: 4mm and 6mm.

Ø 4.5

108.044

108.045

Internal Hex

114.125

Universal Post II Plus

114.124

Demonstrative Sequence of

114.123

Universal Post Transfer

4 mm

3 mm

6 mm

2 mm

4 mm

Ø 4.5

1 mm

6 mm

Universal Post

• Component with molding function by prosthesis construction; • Available in polymer; • For closed tray technique; • Anti-rotational; • Select transfer according to the component to be molded, as prosthetic planning.

6 mm

Alumina

Castable

Temporary

118.188

118.183

118.194

118.189

118.184

118.195

Universal Post

•Available in: -Provisional: for provisional prosthesis; -Alumina: for “metal free” prosthesis; -Castable: casting. •Cemented prosthesis; •Compatible for all Universal Posts, when not prepared.

Screw II Plus

Neotorque

Neotorque

Titanium

116.228

116.002

•Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Universal Post Analogue

6 mm

108.062

Ø 4.5

6 mm

Ø 4.5

4 mm

Universal Post Set 4 mm

Ø 4.5

4 mm

Cylinder of Universal Post

101.040

101.041

108.063

•Available in Titanium; •Replica of prosthetic component; •For prosthesis construction and prosthetic planning.

•Components Kit of Universal Post line, containing the Transfer and Provisional / Castable Cylinders;

91


Prosthetic Components

Demonstrative Sequence of

Angled Post II Plus Internal Hex

20

N.cm

Prosthetic Torque Ratchet Driver

Torque Connection 1.2mm

20

N.cm

Angled Post II Plus

Analogue II Plus

•Available in Titanium; •Cemented prosthesis; •Anti-rotational; •Titanium screw included.

Transfer II Plus

92


17º

2 mm

3 mm

4 mm

114.171

114.172

114.173

114.174

114.175

30º

Internal Hex

Angled Post II Plus

Demonstrative Sequence of

Angled Post II Plus 5 mm

114.176

• Observe indicated torque; • To torque, use Torque Connection 1.2mm (105.005); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Implant Transfer

Antir-otacional

Closed Tray

108.046

Open Tray

108.047

•Component with molding function by prosthesis construction; •For open tray or closed tray technique.

Analogue II Plus Ø 4.3

101.032

Ø 5.0

101.034

•Available in Brass; • Replica of implant platform; • For prosthesis construction and prosthetic planning.

93


Prosthetic Components

Demonstrative sequence of

UCLA II Plus Internal Hex

Prosthetic Torque Ratchet Driver

Torque Connection 1.2

CoCr

Tilite

Titanium

Neotorque Screw

UCLA II Plus

UCLA II Plus

UCLA II Plus

Analogue II Plus

•Directly over the implant; •Screwed or cemented prosthesis; •Multiple or unitary elements; •Available in:

-Tilite and CoCr: overcastting;

-Titanium: provisional or cemented prosthesis;

•Screw not included; •For unitary elements, select Neotorque screw.

Transfer II Plus

94

20

N.cm


Internal Hex

UCLA II Plus

Demonstrative Sequence of

Anti-rotational

UCLA II Plus Titanium

Tilite

118.185

118.190

CoCr

118.214

Screw II Plus

Rotational

Ø 4.1 118.213

Neotorque

Titanium

116.226

116.224

• Application of a thin pellicle with carbon basis, which promotes low friction coefficient, resulting in pre-load increase.

Neotorque

Implant Analogue II Plus Implant Transfer

Anti-rotacional

Open tray

Closed tray

Ø 4.3

101.032

•Available in Brass; •Replica of implant platform; •For prosthesis construction and prosthetic planning.

108.046

108.047

•Component with molding function by prosthesis construction; •Available in Titanium; •For open tray or closed tray technique; •Anti-rotational;

95


Prosthetic Components

Demonstrative Sequence of

Mini Ball Attachment II Plus Internal Hex

O’ring with Cylinder

Protection Disc

Positioner Straight

Positioner 7º

Positioner 14º

Prosthetic Torque Ratchet Driver

Conical Torque Connection 4.1

Ball Attachment Installed.

32

• Available in Titanium; • Directly over the implant; • It´s recommended capture the components in patient’s mouth, one by one; • Application of Nitride Titanium coating for increased the wear resistance; • O’ring with protection disc; • See the demonstrative sequence on page 131.

96

N.cm Mini Ball Attachment II Plus


3 mm

4 mm

5 mm

102.090

102.091

102.092

102.096

102.078

•Castable: Casting in various metals; •May be cemented in natural roots or waxed in bars for overdenture retention.

Demonstrative Sequence of

• To installation, use Conical Torque Connection 4.1mm (105.009); • Observe indicated torque; • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

Castable Attachment Ball

Internal Hex

2 mm

Mini Ball Attachment II Plus

Mini Ball Attachment II Plus

Positioners O’ring Remover

Straight, 7º e 14º

102.078

104.044

• Digital Driver with function of O’ring replacing to the cylinder.

• Available in polymer; • Defines the correct distance between Attachment Ball and O’ring; • Essential for O’ring capturing. • Corrects the parallelism between implants;

O’ring with Cylinder 102.073

O’ring Mount 104.043

• Digital Driver with function of O’ring placement to the cylinder.

• Cylinder in Titanium; • O’ring in polymer; • Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; • Not autoclavable.

O’ring 102.075

Protection Disc 102.077

• Available in polymer (O’ring); • Positioned at the overdenture prosthesis base, has the function of Attachment Ball retention; • Not autoclavable.

•Package with 10 units.

97


T r a n s g i n g i v a l

98


• SLIM FIT Profile: Facilitates the procedures of soft tissues synthesis (suture) by the increasing of taper abutment; •Unitary body: higher mechanical strength; •Stabiliser screw of prosthesis with larger diameter (2mm); •High resistance to insertion torque; •Reduction of working time; •Neoporos Surface treatment; •Used for single stage surgery; •Suitable for inferior protocol technique;

2.6 mm

• Work can be made with fewer number of Implants.

.8

mm

3.0 mm

Ø4

Internal Screw Ø 2.0

TRANSGINGIVAL

Screwed Prosthesis •Castable GT Cylinder •Tilite GT Cylinder •Titanium GT Cylinder •CoCr GT Cylinder

3.75, 4.0 e 4.5 mm

Cemented Prosthesis

Overdenture •Clip Bar •Castable GT Cylinder

Protocol •Cylinder and Distal Extension Bar •Neopronto Technique Passive Fitting Technique •Castable GT Cylinder •Titanium GT Cylinder •Brass GT Cylinder

99


Implants

Product Characteristics • Cylindrical implant; • Unitary body; • NeoPoros Surface; • Double thread (faster installation and less trauma); • Suitable for inferior protocol; • Prosthetic component integrated to the implant; • Emergency profile that facilitates tissue accommodation (Slim Fit); • Transmucosa height 3mm; • Perforation rotation: 800-1200 rpm; • Installation rotation: 30 rpm;

Titamax Drill 3.8

Pilot Drill 3/3.75

Titamax Drill 3.3

Titamax Drill 3.0

Titamax Drill 3.15

Pilot Drill 2/3

Titamax Drill 2.0

Initial Drill

Drill sequence

3.75 mm 4.0 mm 4.5 mm Optional

100


11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.337

109.338

109.339

109.340

109.341

109.342

109.343

109.344

109.345

109.346

109.347

109.348

11.0 mm

13.0 mm

15.0 mm

17.0 mm

109.351

109.352

109.353

109.354

109.355

109.356

109.357

109.358

109.455

109.456

109.457

109.458

Ø 3.75

Ø 4.0

Ø 4.5

Ø 3.75

Ø 4.0

Ø 4.5

101


Neopronto

Product Characteristics

Advantages:

•It´s a system for inferior protocol surgery, guided

•Fast treatment;

with prefabricated bars;

•Reduced cost;

• Case in autoclavable polymer;

•Easy technique and practicality;

• Driver, connections and surgical instruments re-

•Prosthetic bar prefabricated in Titanium;

quired to Neopronto technique; • Specific technique with GT Implants.

•Definitive prosthesis; •Guided surgery; •Mandibular protocol.

102


Items contained in the Neopronto Surgical Kit 110.145

1

Neopronto Surgical Kit Case

103.170

1

Initial Drill Plus

103.175

1

Neopronto Drill 2.0 Plus

103.176

1

Neopronto Drill 3.0 Plus

103.177

1

Neopronto Drill 3.3 Plus

103.178

1

Neopronto Drill 3.8 Plus

125.018

1

Neopronto Drill Guide 2.0

125.019

1

Neopronto Drill Guide 3.0

125.020

1

Neopronto Drill Guide 3.3

125.021

1

Neopronto Drill Guide 3.8

111.026

1

Neopronto Bone Tap 3.75

111.027

1

Neopronto Bone Tap 4.0

111.028

1

Neopronto Bone Tap 4.5

113.021

4

Neopronto Implant Mount

104.007

1

Short Digital Driver 1.2

105.001

1

Hex Connector for Short Ratchet

105.002

1

Hex Connector for Contra-angle

104.027

1

Surgical Torque Ratchet

129.001

1

Titanium Tweezers

125.025

1

Neopronto GT Surgical Bar

125.010

2

Neopronto Surgical Guide Pin

125.009

1

Neopronto Surgical Guide

128.014

3

Neopronto Parallel Indicators

103


104

1

Surgical Guide for the Neopronto Bar positioned over the ridge, with demarcation of the distal oblique incisions.

2

Osteotomy of the alveolar ridge.

3

Surgical Guide for the Neopronto Bar positioned over the ridge, to evaluate the disposition of the implants.

4

Margin of safety from the distance of distal Implants in relation to the mentual emergencies with flags of 7 mm.

5

Stabilization of Surgical Guide for Neopronto Bar with guide pin and drilling with graft drill of 1.6 mm.

6

Neopronto Surgical Bar fixing with graft screws of 2.0 x 12 mm.

7

Positioning of Drill Guide 2 mm and drilling with respective drill. Observe double irrigation.

8

Implants installation. Observe the mounters seating over the Neopronto Surgical Bar.

9

Surgical Bar removed and GT Implants installed.


10

Suture completed.

11

Transfers union with acrylic resin.

12

Placement of Multifunctional Guide between the arches to re-establish the intermaxillary relations and make the union with acrylic resins and the transfers. After union, fluid silicon is injected to the soft tissue impression.

Protection Cylinders installation.

15

Installation of Neopronto Prosthetic Bar over the Titanium cylinders and mounting in the articulator.

18

Final intraoral frontal view.

13

See the Multifunctional Guide.

14

16

Observe the difference between the laboratorial work screw for cementing cylinder and the Neopronto Prosthetic Bar Screw.

17

Cemented titanium cylinders in Neopronto Prosthetic Bar.

105


Neopronto Surgical Guide 125.009

• Allows the osteotomy planning in Neopronto cases or in Conventional Protocol cases; • Assists in implant position planning (relation of distal implants with mentuals emergencies); • Guide the perforations for Neopronto Surgical Bar fixing.

Neopronto Drill Guide

• Attachment on Neopronto Surgical Bar to guide perforations; • With screw to fix Neopronto Surgical Bar; • Observe drill sequence according to the implant.

Pin for Neopronto Surgical Guide

125.010

• Stabilizes the Surgical Guide for Neopronto Bar.

106

125.018

ø2.0

125.019

ø3.0

125.020

ø3.3

125.021

ø3.8


Neopronto Surgical Bar

125.025

• Available in Titanium; • Chambers system for irrigation; • Lower perforations to bar fixing with graft screws 2.0mm; • Higher perforations to Drill Guide and GT Implant installation (with mount); • For better adaptation to the bone, use Neopronto Surgical Guide.

Neopronto Prosthetic Bar

125.002

• Available in Titanium; • Prefabricated structure for Neopronto protocol prosthesis; • May be desgasted conform required and would be cemented over the specific Titanium cylinders for Neopronto technique.

Neopronto Parallel Indicator

Neopronto Bone Tap 3.75 mm 4.0 mm

128.014

• Available in Titanium; • Direction guides to implants installation, in relation to the antagonist.

111.026

111.027

4.5mm 111.028

•Available in Titanium; • Forms the first threads to guide the implant during the installation.

107


Neopronto Mount 113.021

•Available in Titanium; •Specific for GT Implant installation in the Neopronto Technique.

Neopronto Drill Plus ø2.0mm ø3.0mm ø3.3mm ø3.8mm 103.175

103.176

103.177

103.178

• Available in surgical stainless steel; • Twist Drill for Ø2.0mm and tri-spade to anothers diameters; • Markings from 9 to 17mm. DRILLS PLUS: Count with the application of a thin pellicle with carbon basis, which promotes low friction coefficient and reduction of the heat generated on osteotomy.

GT Analogue 101.037

•Available in Titanium; •GT Implant replica; •For prosthesis construction or prosthetic planning.

GT Open Tray Transfer 108.010

• Available in Titanium; • Torque screw included to use with multifunctional guide; • Rotational for protocol.

Neopronto Prosthetic Bar Screw

116.157

• Final fixing of protocol prosthesis; • Torque of 20 N.cm; • To torque, use Torque Connection 1.2mm (105.005); • To torque control, use Prosthetic Torque Ratchet Driver (104.026).

108


GT Protection Cylinder 106.102

• Available in Titanium; • Protect the GT Implant Abutment during the prosthesis confeccion; • To installation, use Digital Driver 1.2 (104.007).

Neopronto Cylinder Screw 116.038

•Use Driver 1.2.

Neopronto Cylinder Work Screw ø 5.0 mm 116.087

• Available in Titanium; • Its function is the union of Prosthetic Bar to the model during the prosthesis construction.

GT Passive Fitting Cylinder Castable

Brass

Titanium

118.174

118.173

118.172

• Cylinders to use the Passive Fitting technique with casted structure over the GT Implants.

Cylinder for cementing of the Neopronto Bar

Observation: After the implants installation, if there is no passive fitting fo Prosthetic Bar, is indicated use the cylinders from the Passive Fitting Technique (described on Surgical Techniques book).

118.013

• Available in Titanium; • Allows prosthesis passivity; • Cemented before waxing; • Screw included only for cementation.

Observation: After the implants installation, if there is no passive fitting fo Prosthetic Bar, is indicated use the cylinders from the Passive Fitting Technique (described on Surgical Techniques book).

109


Z y g o m a t i c

110


111

Zygomatic


Implants

m

0.7 m

Hex ø 3.

2.7

m 0m

mm

Ø

4.

1m

m

Product Characteristics: • Cylindrical implant; • Morse Taper interface, with different dimensions of the conventional implants (same dimensions of WS Titamax Implant) or External Hex 4.1mm; • Smooth surface; • Pre-mounted; • Cover screw not included; • Double thread in CM Zygomatic version; • It is indicated to use the Transepithelial Abutment according to the prosthetic interface.

Observation: accreditation.

This

technique

Information on www.neodent.com.br

Nominal Length

Ø 4.4mm

Ø 3.9mm

112

requires

specific


Morse Taper 30.0 mm

109.522

35.0 mm

109.523

40.0 mm

45.0 mm

47.5 mm

50.0 mm

52.5 mm

109.524

109.525

109.526

109.527

109.528

40.0 mm

45.0 mm

47.5 mm

50.0 mm

52.5 mm

109.451

109.452

109.461

109.453

109.454

External Hex 30.0 mm

109.460

Zygomatic CM Cover Screw

35.0 mm

109.450

External Hex Cover Screw 4.1

117.016

117.018

113


Prosthetic Components

Demonstrative sequence of

Transepithelial Zygomatic Abutment

Prosthetic Torque Ratcht Driver

Torque Connection 1.2mm

Castable

CoCr

Tilite

Transepithelial Abutment Cylinder

Protection Cylinder of Transepithelial Abutment

Transepithelial Abutment Analogue

Transfer

Prosthetic Torque Ratchet Driver

•Available in Titanium; •Minimum interocclusal space of 4.5mm; •Screwed and multiple prosthesis; •Exclusive for Zygomatic Implants;

Conical Torque Connection 4.1mm

•Machined cylinder in Tilite and CoCr for overcastting and castable for casting.

32

N.cm

20

N.cm

Morse Taper External Hex Transepithelial Abutment Transepithelial Abutment

114


5 mm

6 mm

115.023

115.024

115.025

115.026

Morse Taper Transepithelial Abutment 3 mm

4 mm

5 mm

6 mm

115.172

115.173

115.174

115.175

Zygomatic Abutment

4 mm

Transepithelial

3 mm

Demonstrative sequence of

External Hex Transepithelial Abutment

•Morse Taper Model compatible with WS Titamax.

Transepithelial Abutment Analogue 101.018

• Brass; • Transpithelial abutment replica; • For prosthesis construction or prosthetic planning.

Transepithelial Abutment Cylinder Castable

CoCr

Tilite

118.034

118.254

118.150

• Castable: casting; • Tilite: overcastting in Tilite (screw included); • CoCr: overcasting in various metals (screw included).

Protection Cylinder of Transepithelial Abutment

106.056

• Available in Titanium; • Suitable to protect the component in mouth during the prosthesis elaboration; • To installation, use Digital Driver 1.2mm (104.007).

Transepithelial Abutment Open Tray Transfer

108.026

• Available in Titanium; • Open Tray: • Rotational.

Cylinder Screw 116.004

115


Kit Zygomatic

Product Characteristics: • Case in autoclavable polymer; • Drills and connections for Zygomatic Implants – External Hex and Morse Taper; • Insert not included (KAVO).

Observation: This technique requires specific accreditation. Information on www.neodent.com.br

116


* •I ll u st ra

ti ve p h o to

Items contained in Zygomatic Kit 110.214

1

Zygomatic Surgical Kit Case

104.042

1

Zygomatic Installation Driver

105.067

1

Zygomatic Contra-Angle Connection

105.069

1

Connection for exchange of Zygomatic Drills

103.190

1

Zygomatic Spherical Drill 2.9 Plus

103.191

1

Zygomatic Twist Drill 2.7 Plus

103.192

1

Zygomatic Pilot Twist Drill 2.7/3.3 Plus

103.193

1

Zygomatic Twist Drill 3.3 Plus

103.197

1

Zygomatic Countersink Drill CM Plus

103.208

1

Zygomatic Pilot Twist Drill 3.3/3.7 Plus

128.016

1

Zygomatic Height Measurer CM

124.004

1

Zygomatic Labial Protector

129.011

1

Zygomatic Bicortal Probe

129.012

1

Zygomatic Probe

104.007

1

Short Digital Driver 1.2

104.039

1

Short Digital Driver 0.9

117


S u r g i c a l

118

T e c h n i q u e s


119

Surgical Techniques


S u r g i c a l Te c h n i q u e s

Characteristics of Neoguide Kit

Characteristics of Narrow Neoguide Kit

•Specific composition for the technique;

•Case in autoclavable polymer

•Case in autoclavable polymer;

•Instruments for use of the technique, only with CM

•Drivers, connections and surgical instruments necessary to the Neoguide technique; • Technique suitable for virtual planning and flapless surgery.

Implants with diameter of 3.5 mm in reduced prosthetic spaces (mesio-distal); •Supplement to Neoguide Kit; •The Narrow Neoguide technique does not use the implant insertion guide.

Obs.: This technique requires specific accreditation. Information on www.neodent.com.br

120


Items included in Neoguide Surgical Kit

*il lu st ra tiv

110.220

1

Neoguide Surgical Kit Case

103.180

1

Neoguide Rotatory Punch

103.181

1

Neoguide Manual Punch

103.182

1

Neoguide Lance Drill

103.179

1

Neoguide Drill 1.3

103.183

1

Neoguide Drill 2.0

103.184

1

Neoguide Drill 2.8

103.185

1

Neoguide Drill 3.0

103.186

1

Neoguide Drill 3.3

103.187

1

Neoguide Pilot Drill 3.5

103.188

1

Neoguide Pilot Drill 3.75

103.189

1

Neoguide Pilot Drill 4.0

105.002

1

Hex Connector for Contra-angle

105.001

1

Hex Connector for Short Ratchet

104.007

1

Short Digital Driver 1.2

104.005

1

Digital Driver for Torque Connectors

125.037

1

Driver for Neoguide Mount

125.033

1

Neoguide Drill Guide 2.0

125.034

1

Neoguide Drill Guide 2.8

125.035

1

Neoguide Drill Guide 3.0

125.036

1

Neoguide Drill Guide 3.3

125.032

4

Neoguide Guide Clamp

113.033

5

Neoguide Mount 3.5

113.034

5

Neoguide Mount 3.75

113.035

5

Neoguide Mount 4.0

104.027

1

Surgical Torque Ratchet

129.001

1

Titanium Tweezers

125.029

5

Implant Guide 3.5

125.030

5

Implant Guide 3.75

125.031

5

Implant Guide 4.0

e ph ot os

Items included in Narrow Neoguide Kit 110.225

1

Narrow Neoguide Surgical Kit Case

103.196

1

Narrow Neoguide Pilot Drill

103.194

1

Narrow Neoguide Rotatory Punch

103.195

1

Narrow Neoguide Manual Punch

125.039

1

Narrow Neoguide Drill Guide 2.0

125.040

1

Narrow Neoguide Drill Guide 2.8

113.037

2

Narrow Neoguide CM Mount

121


Neoguide Pilot Drills Neoguide Drills

Neoguide Kit

ø1.3

ø2.0

ø2.8

ø3.0

ø3.3

103.179

103.183

103.184

103.185

103.186

• Twist Drill for Ø1.3 and Ø2.0 and Tri-Spade for another diameters; • Available in surgical stainless steel; • Sequence for perforation of surgical alveolus; • Drill 1.3 for perforation in the fixing tubes of Surgical Guide; • Markings from 7 to 17mm.

Narrow Neoguide Kit

ø3.5

ø3.75

ø4.0

103.187

103.188

103.189

103.196

• Surgical stainless steel coated in carbon, which provides a lower friction coefficient; • Preparation of the bone crest for seating of cervical third in CM Titamax Implants; • Indicated for bones type I and II.

DRILL PLUS: Count with the application of a thin pellicle with carbon basis, which promotes low friction coefficient and reduction of the heat generated on osteotomy.

Punch Neoguide Initial Drill

103.182

• Surgical Stainless Steel with a carbon coating that provides reduced frictions; • Breaking of cortical bone.

Rotatory

Manual

Neoguide Kit

103.180

103.181

Narrow Neoguide Kit

103.194

103.195

• Surgical stainless steel coated in carbon, which provides a lower friction coefficient; • Guided circular incision for mucosa removing; • Rotatory Punch – used with contra-angle; • Manual Punch – used manually with Digital Drivers for Torque Connections (104.028); • Also indicated as circular scalpel.

Neoguide Mount ø3.5

ø3.75

ø4.0

Neoguide Kit

113.033

113.034

113.035

Narrow Neoguide Kit

113.037

• Surgical stainless steel; • Specific mount for Neoguide technique; • Narrow Neoguide Kit Mount is used only to the installation of CM Implants Ø3.5mm.

122

Driver for Neoguide Mount

125.037

• Assists in exchange of conventional Mount for the specific Mount of the Neoguide Technique.


Guide for Neoguide Implants

ø3.5

ø3.75

ø4.0

125.029

125.030

125.031

• Available in Titanium; • Guide for installation of CM Implants in Neoguide Technique; • The colors indicate the CM Implant diameter.

Guide Clamp

125.032

• Titanium; • Pin for fix the surgical guide over the ridge; • Effective length of 12mm and Ø 1.3mm.

Neoguide Support Drill Guide

101.054

ø2.0

ø2.8

ø3.0

ø3.3

Neoguide Kit

125.033

125.034

125.035

125.036

Narrow Neoguide Kit

125.039

125.040

• Available in Titanium; • Used with Mini Conical Abutment Analogue for obtain the work model; • 3 spreaders with 1mm of height included; • Technique for prosthesis construction before the surgery.

• Use the corresponding drill to the Surgical Guide diameter (colors); • Embedded in the washers of Surgical Guide; • The colors indicate the CM Implant diameter.

123


S u r g i c a l Te c h n i q u e s

Demonstrative sequence of

Passive Fitting

Technique that allows the passive fitting without welding through Titanium cylinder cementation in the metallic structure. Used for multiple prosthesis and results in laboratorial working time reduction.

124


Castable

Brass

Titanium

118.250

118.248

118.249

Demonstrative sequence of

Passive Fitting

Passive Fitting Cylinders of Micro Conical Abutment

Passive Fitting Cylinders of Mini Conical Abutment

ø4.1 ø5.0

Castable

Brass

Titanium

118.083

118.081

118.082

118.089

118.087

118.088

Passive Fitting Cylinders of Transepithelial Abutment Castable

Brass

Titanium

118.086

118.084

118.085

GT Passive Fitting Cylinders Castable

Brass

Titanium

118.174

118.173

118.172

Passive Fitting Working Screw 4.1 mm

5.0 mm

116.086

116.087

125


Demonstrative sequence of

Passive Fitting

126

1

Regularization of the alveolar ridge.

2

Surgical perforation concluded, checking the correct distance of the Distal Implant in relation to the mentual foramen with a 7mm flag.

3

Installation of 5 CM "C" Titamax Implants Ă˜3.75.

4

Installation of CM Mini Abutments.

5

Installation of squared transfers, replacing by the short screws (mini abutment cylinder screw) and making the union of transferents with acrylic resin.

6

Positioning of the Multifunctional Guide to obtain the intermaxillary relations. Make the union with acrylic resin of the transferents. After union, inject fluid silicon to the soft tissue impression.

7

Removal of Multifunctional Guide and installation of Mini Abutment Analogues to the transferents.

8

Work model with artificial gingiva.

9

Castable Passive Fitting Cylinder, Brass Passive Fitting Cylinder and Titanium Passive Fitting Cylinder with slots and lower diameter than brass, compensating the casting contraction.


Demonstrative sequence of

Passive Fitting

10

Brass Cylinders are placed over the analogues and receive Castable Cylinders fixed with work screws.

11

Casting ring with waxed infrastructure.

12

Casted infrastructure.

13

Infrastructure adaptation over the model.

14

Observe area for cementation.

15

Cementation with Panavia速 (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;

16

Cementation with Panavia速 (Kuraray Med. Inc. Tokyo-Japan) of the structure over the Titanium cylinders;

17

Final intraoral view.

127


S u r g i c a l Te c h n i q u e s

Demonstrative sequence of

Distal Bar Distal Bar Cylinder Mini Abutment

ø4.1

118.169

ø5.0

118.160

GT

118.171

• Available in Titanium; • Retentions to facilitate the acrylic resin union; • Indicated torque: 10 N.cm; • Use Torque Connection 1.2 (105.005); • To torque, use Torque Connection 1.2 (105.005).

Distal Bar Mini Abutment

ø4.1

125.011

ø5.0

125.012

GT

125.023

• Use in Distal Implants to strengthen the Cantilever.

• Technique for facilitate mandibular rehabilitations with Polishing Protector

Passive Fitting using a prosthesis type implant-supported provisional protocol.

Mini Abutment

ø4.1

123.008

ø5.0

123.009

GT

123.012

• Protector for cylinders during finishing and polishing of prosthesis; • Use the corresponding screw to the component for fixation.

128


Demonstrative sequence of

Distal Bar

1

GT Implant installed.

2

Wear prosthesis, maintaining the integrity of posterior area.

3

Cylinders installation in Central Implants and of Distal Bar in posterior implants.

4

Proof of the inferior prosthesis with wear (centrical occlusion position, without interference in cylinders).

5

Placement of a rubber dam over the cylinders to the soft tissue protection.

6

Application of autopolymerizable acrylic resin in the cylinders.

7

Acrylic resin application between the cylinders

8

Application of inferior prosthesis in wear area, repositioning in mouth, patient in occlusion even your full polimerization.

9

Remotion of inferior prosthesis after resin polimerization, cylinders captured.

10

Wear, finishing and polishing of inferior prosthesis with polishing protectors.

11

Implant-supported provisional prosthesis concluded.

12

Final intraoral posterior view.

129


S u r g i c a l Te c h n i q u e s

Demonstrative sequence of

Bar Clip

119.009 Castable Cover for Clip (needs casting)

Clip Bar casted.

119.008 Clip

119.007 Bar (needs casting)

130


Demonstrative sequence of

Attachment Ball Mini

1

Construction of new total prosthesis.

2

4

Attachment Ball installed.

5

7

Placement of O’rings.

8

Inferior view of alleviation.

9

11

Second O’ring captured.

12

10

First O’ring captured.

Implants installed.

3

Components.

Using of positioners to correct the parallelism between the Implants and determinate the correct distance between O’ring and Attachment.

6

Placement of protection disks.

Proof of prosthesis to verify adaption without interference.

Lateral view of set.

131


B o n e

G r a f t i n g &

O r t h o d o n t i c

132

A n c h o r a g e


133

and

Orthodontic Anchorage

Bone Grafting


B one G raft I N G AND O rthodontic A nchorage K I T

* il lu st

ra ti v e

p h o to

Complete Kit: Bone Grafting & Orthodontic Anchorage 110.227 104.018 105.063 105.023 103.045 103.079 103.044 103.043 103.078 103.042 103.207 104.033 105.039 105.040 105.025

134

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

Bone Grafting and Orthodontic Anchorage Case Bone Grafting Manual Driver Philips Connection for Manual Driver Philips Connection for Contra-angle Drill 1.6 for Contra-angle Drill 1.3 for Contra-angle Drill 1.1 for Contra-angle Drill 1.6 for Straight Piece Drill 1.3 for Straight Piece Drill 1.1 for Straight Piece Graver for Bone Grafting and Orthodontic Anchorage Orthodontic Anchorage Driver Contra-angle connection – Anchorage - Long Contra-angle connection – Anchorage – Short Ratchet Adaptor for contra-angle connections


Bone Grafting Kit 110.227

1

Bone Grafting and Orthodontic Anchorage Case

104.018

1

Bone Grafting Manual Driver

105.063

1

Philips Connection for Manual Driver

105.023

1

Philips Connection for Contra-angle

103.045

1

Drill 1.6 for Contra-angle

103.079

1

Drill 1.3 for Contra-angle

103.044

1

Drill 1.1 for Contra-angle

103.043

1

Drill 1.6 for Straight Piece

103.078

1

Drill 1.3 for Straight Piece

103.042

1

Drill 1.1 for Straight Piece

103.207

1

Graver for Bone Grafting and Orthodontic Anchorage

Orthodontic Anchorage Kit 110.227

1

Bone Grafting and Orthodontic Anchorage Case

103.079

1

Drill 1.3 for Contra-angle

103.044

1

Drill 1.1 for Contra-angle

103.078

1

Drill 1.3 for Straight Piece

103.042

1

Drill 1.1 for Straight Piece

104.033

1

Orthodontic Implant Driver

105.039

1

Long Connection

105.040

1

Short Connection

105.025

1

Ratchet Adaptor

135


BONE GRAFTING AND ORTHODONTIC ANCHORAGE

1m m

Hole Diameter: 0,7mm

Hex Size: 2.7 mm

Screw for Bone Grafting 6 mm

8 mm

10 mm

12 mm

14 mm

Ø 1.5 mm

116.194

116.196

116.198

116.199

116.200

Ø 2.0 mm

116.203

116.205

116.207

116.209

Expanded Head

8 mm

10 mm

12 mm

14 mm

116.210

116.211

116.212

116.213

Ø 1.5 mm Ø 2.0 mm

116.214

116.215

116.216

• Available in Titanium; • Osseous block fixation; • Self-tapping.

Implants for Orthodontic Anchorage

Expanded Head

136

Standard Head

Ø 1.5 mm

Ø 2.5 mm

Ø 3.70mm

Ø 2.0 mm

Ø 3.0 mm

Ø 3.85 mm

Collar

7 mm

9 mm

11 mm

Ø 1.3 mm

Low

109.484

109.485

109.486

Ø 1.3mm

Medium

109.487

109.488

109.489

Ø 1.6 mm

Low

109.493

109.494

109.495

Ø 1.6mm

Medium

109.496

109.497

109.498

• Implants for orthodontic movement; • Available in Titanium alloy according to ASTM-F136 (level V); • Torque resistance up to 10 N.cm (Ø 1.3mm) and 20 N.cm (Ø 1.6mm); • Self-tapping; • Collar height: -Low Collar: 0mm. -High Collar: 1mm.


B one G raft I N G AND O rthodontic A nchorage 11 mm 9 mm 7 mm

Drills for Orthodontic Anchorage Ø 1.1mm

Ø 1.3mm

Ø 1.6mm

Straight Piece

103.042

103.078

103.043

Contra-angle

103.044

103.079

103.045

Graver for Bone Grafting and Orthodontic Anchorage 103.207

• Suitable for bones type I and II; • Markings referent to the implant length (7.9 and 11mm).

• Stainless steel; • Initial severance of cortical.

Connections and Adaptors Orthodontic Anchorage 105.040

105.039

Short

Long

105.025

Orthodontic Implant Driver 104.033

• Stainless steel; • Manual installation of Orthodontic Anchorage implants.

• Connections for Anchorage Implant installation with Ratchet and Contraangle.

137


B one G raft I N G AND O rthodontic A nchorage

Hand Driver

104.018

• Assists in handling of Philips Driver (105.063) and of Graver for Bone Grafting and Orthodontic Anchorage (103.207).

Philips Driver

• Stainless steel; • Screws installation for Bone Grafting.

138

Straight part

ContraAngle

105.063

105.023


B one G raft I N G AND O rthodontic A nchorage

Sequence of

1

Package of Orthodontic Anchorage Implant.

2

Seal opening to get the implant in sterile capsule.

3

Cover removal to access the implant.

4 Capture of implant with Orthodontic Anchorage Contra-angle

5

Option to insert the implant with a micromotor.

6 Implant installation.

7 Insert option of implant manually with Orthodontic Anchorage Driver (104.033).

Connection(105.040).

8 Implant installed.

139


I n s t r u m e n t s

140


Instruments

Sterilise Sterilize on the eve of or in the day of procedure. It is recommended, preferably, follow the method of sterilization by steam autoclaving, and also the parameters and procedures established in the regulation BS EN ISO 17665-1:2006 Moist heat. Requirements for the development, validation and routine control of a sterilization process for medical devices, or to proceed conforming to the instructions manual from the manufacturer of the autoclave. WARNING: THE KITS ARE DAMAGED WHEN SEALED WITH ADHESIVE TAPE. DO NOT STERILIZE PRODUCTS MADE IN POLYMER AT HOTHOUSE. VALIDITY OF STERILIZATION: 7 to 15 days, since kept in clean environment, dry and away from the sun.

HYGIENE Kits Neodent and surgical instruments should be properly cleaned after each use. Do not let them in contact with moisture for prolonged periods. 1st Step: Disassemble piece (if applicable). 2nd step: Immerge the whole piece in enzymatic detergent with solution of 10%. 3rd Step: Wash in an ultrasonic washer for about 10 minutes, 4th step: Rinse with distilled water in abundance to remove completely the solution residues, making use of brushes. 5th step: Dry with clean and dry cloth or compressed air. 6th step: Realize visual inspection, observing if the cleaning process has been successful. If there is any dirt, the piece should be re-immersed in detergent – 1st and 2nd steps -, and, if is necessary, the cleaning should be done with the help of a wire brush for dental use (repeat the rinsing and drying sequence). 7th Step: Select the packaging in accordance with the sterilization process. Preferably use surgical level film and paper envelope.

IMPORTANT: Never store the material without complete drying. Drying is very important to prevent oxidations. ATTENTION: Do not use not incrusted products (non-enzymatic). They tend to darken the pieces and also cause oxidation. The use of enzymatic liquid with concentration higher than 10%, as well as drying of pieces containing cleaning solution residues, helps oxidation and must be avoided.

141


Surgical Kit

Product Characteristics: • Case in autoclavable polymer; • Drivers, connections and surgical instruments for Titamax Implants and External Hex Alvim, Internal Hex, Morse Taper and GT.

Observation: Items contained in Surgical Kit are also sold separately. Following, three surgical kits are suggested: Initial, Intermediary and Advanced.

142


Advanced

Intermediate

Initial

110.206

1

Surgical Kit Case

X

X

X

103.170

1

Initial Drill PLUS

X

X

X

103.171

1

Alvim Twist Drill 2.0 PLUS

X

X

X

Twist Drill 2.0 PLUS

X

X

X

Pilot Drill 2/3 PLUS

X

X

X

X

X

X

X

Items contained in Surgical Kit

103.162 103.213

*i ll u st

ra ti ve

p ic tu re

1 1

103.163

1

Twist Drill 2.8 PLUS

X

103.164

1

Twist Drill 3.0 PLUS

X

103.165

1

Twist Drill 3.15 PLUS

X

103.166

1

Twist Drill 3.3 PLUS

X

X

X

103.167

1

Twist Drill 3.8 PLUS

X

X

X

Twist Drill 4.3 PLUS

X

X

X

X

103.168

1

103.172

1

Alvim Drill 3.5 PLUS

X

103.173

1

Alvim Drill 4.3 PLUS

X

X

103.174

1

Alvim Drill 5.0 PLUS

X

X

103.209

1

Countersink Drill 3.3 PLUS

X

X

X

103.239

1

SF Countersink Drill 4.1 PLUS

X

X

X

X

103.211

1

Countersink Drill 4.3 PLUS

X

103.242

1

SF Countersink Drill 4.5 and 5.0 PLUS

X

X

103.216

1

CM Pilot Drill 2.8/3.5 PLUS

X

X

103.217

1

CM Pilot Drill 3/3.75 PLUS

X

X

103.218

1

CM Pilot Drill 3.3/4.0 PLUS

X

X

103.219

1

CM Pilot Drill 3.6/4.3 PLUS

X

X

103.220

1

CM Pilot Drill 4.3/5.0 PLUS

X

X

103.091

1

Extension Drill

X

X

X

105.047

1

Connection for TI Contra-angle 4.1 and 4.3

X

X

X

105.045

1

Short TI Ratchet Connection 4.1 and 4.3

X

X

X

105.046

1

Long TI Ratchet Connection 4.1 and 4.3

X

X

X

105.050

1

Contra-angle TI Connection 5.0

X

X

X

105.048

1

Short TI Ratchet Connection 5.0

X

X

X

105.049

1

Long TI Ratchet Connection 5.0

X

X

X

105.001

1

Hex Connection for Short Ratchet

X

X

X

105.018

1

Hex Connection for Long Ratchet

X

X

X

105.002

1

Hex Connection for Contra-angle

X

X

X

128.015

1

Height Measurer CM

X

X

113.014

1

H.E. Long Mount 3.3

X

X

113.020

1

GT Mount

X

113.036

1

CM Long Mount 3.5

X

X

128.019

1

Parallel Indicators 2.8/3.5

X

X

X

128.020

1

Parallel Indicators 3.0/3.75

X

X

X

128.021

1

Parallel Indicators 3.3/4.0

X

X

X

128.022

1

Parallel Indicators 3.6/4.3

X

X

X

128.023

1

Parallel Indicators 4.3/5.0

X

X

X

104.039

1

Short Digital Driver 0.9

X

X

X

104.007

1

Short Digital Driver 1.2

X

X

X

104.028

1

Digital Driver for Contra-angle Connections

X

104.027

1

Surgical Torque Ratchet Driver

X

X

X

129.004

1

Depth Probe

X

X

X

129.001

1

Titanium Tweezers

X

X

X

105.030

1

Short Ratchet Connection II Plus

X

105.031

1

Long Ratchet Connection II Plus

X

105.068

1

Contra-angle Connection II Plus

X

103.077

1

Countersink Drill II Plus 4.3

X

103.070

1

Countersink Drill II Plus 5.0

X

X

X

143


WS Kit

Product Characteristics: • Case in autoclavable polymer; • Drivers, connections and surgical instruments for CM Titamax Implants and WS Titamax installation.

Observation: Items contained in Surgical Kit are also sold separately. Descriptions shown next.

144


Items contained in WS Kit *i ll u st

ra ti ve

p ic tu re

110.218

1

WS Surgical Kit Case

103.170

1

Initial Drill Plus

103.162

1

Twist Drill 2.0 PLUS

103.163

1

Twist Drill 2.8 PLUS

103.164

1

Twist Drill 3.0 PLUS

103.166

1

Twist Drill 3.3 PLUS

103.167

1

Twist Drill 3.8 PLUS

103.168

1

Twist Drill 4.3 PLUS

103.169

1

Twist Drill 5.3 PLUS

103.091

1

Extension Drill

103.213

1

Pilot Drill 2/3 PLUS

103.217

1

CM Pilot Drill 3.0/3.75 PLUS

103.218

1

CM Pilot Drill 3.3/4.0 PLUS

103.214

1

Pilot Drill 3.8/4.3 PLUS

103.220

1

CM Pilot Drill 4.3/5.0 PLUS

103.215

1

Pilot Drill 4.3/5.3 PLUS

103.221

1

CM Pilot Drill 5.3/6.0 PLUS

104.007

1

Short Digital Driver 1.2

104.027

1

Surgical Torque Ratchet

105.001

1

Hex Connection for Short Ratchet

105.018

1

Hex Connection for Long Ratchet

105.002

1

Hex Connection for Contra-angle

114.230

1

WS Post 4.5x6x0.8 Prosthetic Selection

114.231

1

WS Post 4.5x6x1.5 Prosthetic Selection

114.232

1

WS Post 4.5x6x2.5 Prosthetic Selection

114.233

1

WS Post 4.5x6x3.5 Prosthetic Selection

128.020

1

Parallel Indicators 3.0/3.75

128.021

1

Parallel Indicators 3.3/4.0

128.024

1

WS Parallel Indicators 4.3/5.0

128.025

1

WS Parallel Indicators 5.3/6.0

129.001

1

Titanium Tweezers

129.004

1

Depth Probe

145


Drills

Product Characteristics: The drills suffer wear during their use. Evaluate their cut effectiveness periodically and observe the need for substitution to avoid loss of implants.

DRILLS PLUS: Counts upon the application of a thin pellicle with carbon basis which promotes reduced friction and reduction of the heat generated in the osteotomy.

146


16.0 13.0 10.0

11.5

Alvim Drill

8.0

Plus (Scaled) Surgical Stainless Steel

Zirconia

Ø 3.5

103.172

103.253

Ø 4.3

103.173

103.254

Ø 5.0

103.174

103.255

Countersink Drill Plus External Hex

Slim Fit

• Surgical Stainless Steel and Zirconia; • Instrumentation sequence of surgical alveolus for Alvim Implants; • Lenghts: -Standard: 35 mm.

Internal Hex Zirconia

Ø 3.3

103.209

103.263

Ø 4.3

103.077

103.298

Ø 4.1

103.242

103.292

Ø 5.0

103.070

103.299

Ø 4.3

103.211

103.293

Ø 5.0

103.210

103.267

103.212

103.268

17.0 15.0

Ø 4.5/ Ø 5.0

13.0 11.0 9.0 7.0 5.0

Surgical Stainless Steel

Surgical Stainless Steel

Zirconia

• Surgical Stainless Steel and Zirconia; • Prepare of the bone crest for cervical third seating in Implants 3.3, 3.75, 4.0,4.5 and 5.0mm (external hex) and 4.3 and 5.0mm (internal hex).

6.0

Initial Drill Plus

Ø 2.0

103.170

• Surgical Stainless Steel; • Cortical disruption; • Diameter of 2.0mm.

Twist Drill Plus

Long

Intermediate

Ø 2.0

103.228

103.162

103.222

Ø 2.8

103.229

103.163

103.223

Ø 3.0

103.230

103.164

Pilot Drill Plus 2.0 Nível ósseo

Alvim

Short Alvim

Surgical Stainless Steel

Surgical Stainless Steel

1.0

Short

Zirconia

2/3 mm

103.213

2.8/3.5 mm

103.216

103.272

3/3.75 mm

103.217

103.273

3.3/4 mm

103.218

103.274

3.6/4.3 mm

103.219

103.275

4.3/5 mm

103.220

103.276

3.8/4.3 mm

103.214

103.270

4.3/5.3 mm

103.215

103.271

5.3/6 mm

103.221

103.277

Ø 3.15 Ø 3.3

103.171

Zirconia 103.232

103.224

103.165

103.245

103.246

103.166

103.225

103.247

Ø 3.8

103.167

103.226

103.248

Ø 4.3

103.168

103.227

103.249

Ø 5.3

103.231

103.244

103.169

103.250

• Surgical Stainless Steel and Zirconia; • Instrumentation sequence of surgical alveolus for Titamax Implants; • Lenghts: -Short: 31mm; -Intermediate: 35mm; -Long: 43mm.

• Surgical Stainless Steel and Zirconia; • Its function is increase the surgical alveolus diameter, facilitating the next drill entry; • Substitutes the Countersink Drill in use of the Morse Taper Implants; • Markings indicates: osseous level, 1.0mm and 2.0mm intraosseous.

147


Parallel Indicators

128.023

3.6/4.3

128.022

3.3/4.0

128.021

3.0/3.75

128.020

2.8/3.5

128.019

Ø 5.3/6.0

128.025

Ø 4.3/5.0

128.024

WS

4.3/5.0

• Available in Titanium; • Instrumental for implant position orientation; • Diameter of the central belt corresponding to the CM Implants diameter; • Smaller side for use after drill 2.0mm; • Bigger side for use after last drill, before the implant installation.

Ratchet Connection

External Hex – Ti

Internal Hex – II Plus

Short

Long

Short

Long

Short

Long

4.1/4.3

4.1/4.3

5.0

5.0

4.3/5.0

4.3/5.0

• For the installation of External Hex TI Implants and Internal Hex II Plus with Surgical Torque Ratchet Driver (104.027); • Ratchet Connection II Plus with markings indicating the face position of internal hex.

105.045

105.046

105.048

105.049

105.030

105.031

Contra-angle Connection

External Hex – TI

4.1/4.3

5.0

Internal Hex – II Plus

4.3/5.0

• To capture the implant directly on the package; • For installation of External Hex Ti Implants and Internal Hex Ti Implants with contra-angle, or coupled to the Digital Driver (104.028) for manual installation; • With tweezers to increase the security in transport and implant installation.

105.047

148

105.050

105.068


Hex Connection for Contra-Angle

• Available in surgical stainless steel; • Adaptation of hex mounters; • For implant insertion, using motor and contra-angle; • Silicone ring for best fixing and mounter transport. 105.002

Hex Connection for Ratchet (Ratchet Driver Connection)

• Available in surgical stainless steel; • Adaptation of hex mounters; • Fit in squared ratchets; • Silicone ring for best fixing and mounter transport. 105.001

105.018

Mounters (Implant Mount) CM

External Hex.

ø3.5 mm

ø3.3 mm

GT

• Available in Titanium; • Requires Hex Connections 105.002 in motor use and 105.001 for Ratchet; • Use Hex Driver 1.2mm for handling (104.007); • Long mounters 3.3 and 3.5 indicated for substitute the implant mount in cases of reduced interproximal space (mesio-distal).

113.036

113.014

113.020

Drill Extension

• Available in surgical stainless steel; • With clamp bolt for drill fixation; • Fix screw to the drill extension; • For tighten and unleash the screw, it is necessary only around half turn of Hex Driver 1.2 (104.007).

103.091

149


Digital Driver

• Available in surgical stainless steel; • Connected to the Contra-angle Connections Ti and II Plus, it becomes a manual driver for the implant installation.

104.028

Hex Digital Driver 0.9 mm Short

Medium

Long

• Available in surgical stainless steel; • With divergent hex for best fixing and screw transport; • Handling of Cover Screws in Implants 3.3, 3.5, 3.75,4.0, 4.3 and Healing 3.3 height 2mm. -Short: 20mm; -Intermediate: 25mm; -Long: 38mm.

104.039

104.041

104.040

Hex Digital Driver 1.2 mm

Short

Medium

Long

• Available in surgical stainless steel; • With divergent hex for best fixing and screw transport; • Handling of Mounters in Implants and Cover Screws. -Short: 20mm; -Intermediate: 25mm; -Long: 38mm.

104.007

150

104.012

104.010


Titanium Tweezers

129.001

• To implants manipulation; • New system of tweezers, that avoids the deviation of the active tip; • Scale in milimeters, for conference during the procedures.

Surgical Torque Ratchet Driver 104.027

• Available in surgical stainless steel; • Extremely secure (a variation of less than 5%); • Realize calibration annually; • Fitting for square connections; • Collapsible ratchet, that allows the correct cleaning of set.

Use Instructions

The Surgical Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.

For this, only apply the force on the RATCHET STEM, 1 until it reaches the value set in LATERAL GRADUATION 2 which corresponds to the desired torque.

The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.

The Neodent Surgical Torque Ratchet has pre-calibrated torques. •Prosthetic: 10,15,20,32 and 45 N.cm; •Surgical: 45,60 and 80 N.cm.

CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.

151


ProsthetIc Instruments

1 1 1 1 1 1 1 1 1 1 1 1 1 1

152

110.213 105.065 105.041 105.005 105.006 105.007 105.008 105.009 105.044 105.071 128.015 104.005 104.016 104.026

Prosthetic Kit Case Torque Connection 0.9 Short Torque Connection 1.2 Torque Connection 1.2 Torque Connection 1.6 Slot Torque Connection Square Torque Connection Conical Torque Connection 4.1 Short Conical Torque Connection 4.1 Long Torque Connection 1.2 CM Height Meter Digital Driver for Torque Connections Transfer Driver Prosthetic Torque Ratchet Driver

X X X X X X X X X X X X X X

tr a ti v

e p ic tu re

Basic

Complete

* il lu s

X X X X X

X X

X


Prosthetic Adaptation Driver

104.036

•Mandrel for analogues fixing and prosthetic components machining..

Prosthetic Torque Ratchet Driver 104.026

• Surgical stainless steel; • Cleansing and sterilizing of the disassembled ratchet; • Extremely secure (variation less than 5%); • Realize calibration annually; • Fitting for square connections;

Use Instructions

The Surgical Torque Ratchet Driver was projected to allow the required torque application, and also allow that this torque be checked simultaneously with the same instrument.

The Neodent Surgical Torque Ratchet has pre-calibrated torques. •Prosthetic: 10,15,20,32 and 45 N.cm; • Surgical: 45,60 and 80 N.cm.

For this, only apply the force on the RATCHET STEM, 1 until it reaches the value set in LATERAL GRADUATION, 2 which corresponds to the desired torque.

The ratchet function serves for both sides. Just pull and turn the pin driver 180°. However, the torque function is only in clockwise.

CAUTION: When you reverse the direction of torque, the gear can be detached from the driver body and fall it. Therefore, this reversal should only be done with the driver connected to the piece or outside the patient’s mouth.

153


Drivers and Torque Connections 1.2 Short

105.041

1.6 Short

105.042

Conical 4.1 Short

105.044

0.9

1.2

105.065

1.6

105.005

105.006

Slot

105.007

Square

105.008

Conical 4.1

105.009

1.2 Long

105.071

Digital

104.005

•Surgical Stainless Steel; •Observe corresponding connection to the prosthetic component screw; •To torque control, the connections must be adapted to the Prosthetic Torque Ratchet Driver (104.026); •To connections manual torque, must be adapted to the Digital Driver (104.007);

Digital Driver 1.2mm

Digital Driver 0.9mm Short

104.039

Intermediate

Long

104.041

104.040

• Surgical Stainless Steel; • Length: -Short: 2 cm; -Intermediate: 2.6 cm; -Long: 3.8 cm; • Observe screw indications.

Short

Medium

Long

104.007

104.012

104.010

• Surgical Stainless Steel; • Length: -Short: 2cm; -Intermediate: 2,6 cm; -Long: 3,8 cm. • Observe screw indications.

Contra-angle Torque Connections 0.9

1.2

1.6

Slot

105.066

105.010

105.012

105.013

Transfer Driver

104.016

• Surgical Stainless Steel; • Indicated for Conical Transfer (used in closed tray transfer).

• Connections for torque in prosthesis screws with motor; • Observe connection according to the corresponding screw.

154


Prosthetic Instruments • Ill ust rati ve Pho to

110.223 114.191 114.192 114.193 114.194 114.195 114.196 114.197 114.198 114.199 114.200 114.201 114.202 114.203 114.204 114.205 114.206 114.207 114.208 114.209 114.226 114.227 114.228

CM Prosthetic Selection Kit Case CM Post 3.3x4x0.8 Prosthetic Selection CM Post 3.3x4x1.5 Prosthetic Selection CM Post 3.3x4x2.5 Prosthetic Selection CM Post 3.3x4x3.5 Prosthetic Selection CM Post 3.3x4x4.5 Prosthetic Selection CM Post 3.3x4x5.5 Prosthetic Selection CM Post 3.3x4x6.5 Prosthetic Selection CM Post 3.3x6x0.8 Prosthetic Selection CM Post 3.3x6x1.5 Prosthetic Selection CM Post 3.3x6x2.5 Prosthetic Selection CM Post 3.3x6x3.5 Prosthetic Selection CM Post 3.3x6x4.5 Prosthetic Selection CM Post 3.3x6x5.5 Prosthetic Selection CM Post 3.3x6x6.5 Prosthetic Selection CM Post 4.5x6x0.8 Prosthetic Selection CM Post 4.5x6x1.5 Prosthetic Selection CM Post 4.5x6x2.5 Prosthetic Selection CM Post 4.5x6x3.5 Prosthetic Selection CM Post 4.5x6x4.5 Prosthetic Selection CM Anatomical Post Height 1.5 Prosthetic Sel. CM Anatomical Post Height 2.5 Prosthetic Sel. CM Anatomical Post Height 3.5 Prosthetic Sel.

114.210 114.211 114.212 114.213 114.214 114.215 114.216 114.217 114.218 114.219 114.220 114.221 114.222 114.223 114.224 114.230 114.231 114.232 114.233 104.007 114.335 114.336 114.337

CM Post 4.5x4x5.5 Prosthetic Selection CM Post 4.5x4x6.5 Prosthetic Selection CM Post 4.5x6x0.8 Prosthetic Selection CM Post 4.5x6x1.5 Prosthetic Selection CM Post 4.5x6x2.5 Prosthetic Selection CM Post 4.5x6x3.5 Prosthetic Selection CM Post 4.5x6x4.5 Prosthetic Selection CM Post 4.5x6x5.5 Prosthetic Selection CM Post 4.5x6x6.5 Prosthetic Selection CM Angled Post 3.3x6x1.5 17º Prosthetic Selection CM Angled Post 3.3x6x2.5 17º Prosthetic Selection CM Angled Post 3.3x6x3.5 17º Prosthetic Selection CM Angled Post 3.3x6x1.5 30º Prosthetic Selection CM Angled Post 3.3x6x2.5 30º Prosthetic Selection CM Angled Post 3.3x6x3.5 30º Prosthetic Selection WS Post 4.5x6x0.8 Prosthetic Selection WS Post 4.5x6x1.5 Prosthetic Selection WS Post 4.5x6x2.5 Prosthetic Selection WS Post 4.5x6x3.5 Prosthetic Selection Short Digital Driver 1.2 CM Anatomical Post Lateral 1.5 Prosthetic Selection CM Anatomical Post Lateral 2.5 Prosthetic Selection CM Anatomical Post Lateral 3.5 Prosthetic Selection

155


S u r g i c a l

156

I n s t r u m e n t s


157

SURGICAL INSTRUMENTS


Bone Profile Drill External Hex

Internal Hex

Ø 3.3 mm Ø 4.1 mm Ø 4.3 mm Ø 5.0 mm Ø 4.3 mm Ø 5.0 mm

Trephine Burs

103.039

Ø 3.3 mm Ø 4.1 mm Ø 4.3 mm Ø 5.0 mm Ø 8.0 mm Ø 10.0 mm 103.051

103.026

103.087

103.027

103.028

103.029

103.030

103.085

103.031

0.35mm

Flags 7 mm

9 mm

12 mm

128.003

128.008

128.007

• Surgical Stainless Steel; • Adaptive to mirrors handle; • Indicated for surgical/prosthetic planning.

Angle Meter 30º

17º 128.017

• Available in Titanium; • Angulations: 17° and 30°. • For selection and angulation planning of prosthetic component during the surgical procedure; • Use indication: after Twist Drill 2.0.

Alvim Radiographic Positioner Ø 3.5 mm Ø 4.3 mm Ø 5.0 mm 129.009

129.013

129.014

• Available in Titanium; • Used to check flapless osteotomy depth; • It is suggested make the periapical radiography for evaluation.

Prosthetic Surgical Guide 16

Guide

Pin

13

103.092

103.093

10

11.5 8

• Available in Titanium; • Components for surgical guide construction; • Internal diameter of prosthetic guide 2mm; • Heights: 6mm and 10mm; • Surgical Guide: package with 10 units (5 units of 10mm and 5 units of 6mm); • Surgical Guide Pin: package with 5 units.

158

103.103

• Surgical Stainless Steel; • Used in the second surgical phase; • Adapt the bone around implant platform, preparing the emergency profile compatible with the prosthetic component profile; • Each drill has a guide with specific diameter.

• Surgical Stainless Steel; • Osseous cylinder collect; • Implants removal;

128.018

103.102


Osteotomes 1.8 mm

2.5 mm

3.0 mm

3.5 mm

4.0 mm

4.5 mm

110.154

110.155

110.156

110.157

110.158

110.159

• Surgical Stainless Steel; • Concave cutting tip for atraumatic elevation of maxillary sinus floor; • Used in the preparing of surgical alveolus for implants installation in posterior maxillary area, which has less osseous height; • Markings from 7 to 17mm.

17 mm 13 mm 9 mm

15 mm 11 mm 7 mm

Osteotomes Modified

1.8 mm

2.5 mm

3.0 mm

3.5 mm

110.160

110.161

110.162

110.163

• Surgical Stainless Steel; • Convex tip; • Used when thickness bone is insufficient, requiring compression and prior bone expansion to the implant placement; • Markings from 7 to 17mm. 17 mm 13 mm 9 mm

15 mm 11 mm 7 mm

Osteotomes Tray

110.180

• Autoclavable polymer; • Osteotomes sold separately.

159


Mallet

126.001

•Surgical Stainless Steel; •Used in compactors and expanders; •Weight: 150g.

Curettes for Sinus Lifting

126.008

126.009

126.010

• Surgical Stainless Steel; • Detachment of sinusal membrana.

160

126.011

126.012


Metal Bone Scraper 127.018

127.016

127.017

127.019

Negativo

Reto

Positivo

Lâmina

• Used to remove autogenous bone applied in reconstructive surgery; • Autoclavable; • Blade included; • Silicone handle; • Blade coated with Aluminium Nitride.

Disposable Bone Scraper

127.023

• Used to remove autogenous bone; • Unique usage; • Sterile.

Disposable Bone Collector • Used to collect autogenous bone; • Polymer; • Unique usage; • Adaptive to vacuum pump; • Two disposable sieves included; • Use the second tip to saliva suction (beware of contamination).

107.003

107.008

161


Surgical Labial Retractor

124.001

• Available in Surgical Stainless Steel; • Rounded corners to minimize the surgical trauma.

Columbia Retractor 124.003

• Available in Surgical Stainless Steel; • Rounded corners to minimize the surgical trauma.

Depth Probe 129.004

• Available in Titanium; • For probing preparation and depth analysis; • Scale in milimeters for conferences during procedure.

Scalpel Handle 129.008

• Available in Surgical Stainless Steel; • For use of conventional scalpel blade; • Blade not included.

162


Blade and Handle Bivers • Handle and blade in surgical stainless steel; • Atraumatic exodontics to implants installation; • Similar with a periostomal; • Blades supplied individually.

129.002

129.005

Complement Tray 110.211

• Autoclavable polymer; • Used to organize the drills and auxiliar connections.

Bone Mill

127.011

• Surgical Stainless Steel; • Bone volume gain; • The blade has 3-year of warranty against rust; • With lever for better facility during utilization; • Bone mill pestle with slots to optimize the bone block locking during use; • Avoid bone handling originated in tissue bank.

Test

Bovine bone block with volume = 1,76 cm³

Particles amplified.

Volume gain was approximately of 7 times.

163


Surgical Motor

Calibration System Contra-angle

Electronic and Mechanical (Dynamometre)

Electronic

With light

Without light

Control Unit

PORTABLE

1 CONTROL PANEL WITH EASIER INTERFACE

The Neosurg XT and XT Plus are small, light and can be easily transported anywhere. The products are ideal for anyone who tends to more than one surgery and wishes to have just one surgical motor.

2 MECHANICAL CALIBRATION SYSTEM As well as electronic calibration, the Neosurg XT Plus has a torque ratchet to guarantee yet more precision of the micro motor and contra-angle. The calibration is executed directly by the professional, without the need for maintenance from the manufacturer.

3 PUMP CONNECTED TO THE MOTOR It´s not necessary to autoclave, the hose system is sterilisation only.

Micro Motor Contra-angle

4 IRRIGATION SYSTEM WITH METAL CONNECTORS Allows perfect adaption of the irrigation handle, offering resistance and security. Can be sterilised.

5 MICRO MOTOR REINFORCED WITH A TITANIUM COATING Use the magnetic induction system, which does not produce noises nor vibrations. High Precision of the torque and variation of speeds.

6 OPTICAL FIBER (XT PLUS VERSION) Rigid body of the micro motor to not risk breaking. Doesn´t lose brightness with time of use, unlike the LED.

7 CONTRA- ANGLE WITH REDUCED SIZE Highly resistant Titanium Body (XT Plus version), Internal and external irrigation system. Head with a reduced size and ergonomically compact body. Better visibility, access and mobility within the oral cavity.

164

INTELLIGENT CONTROL PEDAL

All adjustments of the irrigation system, programs and speeds can be triggered by the pedal, leaving the hands free for surgical procedure. It was developed to avoid the accidental activation of micro motor system (progressive acceleration.)


Illumination

2

Exclusive Neosurg Xt Plus

1

3

4

XT

130.001

XT PLUS

132.023

CONTRA-ANGLE WITH DENTAL LEVER

132.002

CONTRA-ANGLE PUSH BUTTON WITH LIGHT

5 6

132.025

7 165


INTERNATIONAL DISTRIBUTORS Argentina Horácio Y Norberto Calamante Santa Fé 3153 2000 Rosario Phone: 54 341 438 4433 Hcalamante@disden.com.ar

AFFILIATES

Chile Comercial Express Dent Rut 78.378.3160-3 Av. Presidente Errazuriz 4125 Las Condes – Santiago - Chile Phone: 56 2 233 6690/ 56 2 263 3720 Rafaelrecabarren@expressdent.cl

Bauru Al. Dr. Octávio Pinheiro Brizolla, 7-46 17012-059 - Bauru - SP - Brazil Phone: ++ 55 14 3201-3500

Colombia Neoimplants Colômbia Ltda. Calle 119 N. 14 A - 25 Ofic. 107 - Bogotá Phone: 752 151 560 17595 Eduardo_abadia@yahoo.com

Belo Horizonte R. Grão Pará, 554 30150-341 - Belo Horizonte - MG - Brazil Phone: ++ 55 31 3071-8700

Spain P.D. Per, S.L Cristóbal De Boleda, 14 25006 - Lleida Phone: 34 9021 17077/ 9021 17120 Perdental@perdental.com

Brasília SH/SUL, QD. 06 CONJ “A” BL. “F” Loja 20 70316-901 - Brasília - DF - Brazil Phone: ++55 61 3298-3200 Curitiba Av. Visconde de Guarapuava, 3832 80250-220 - Curitiba - PR - Brazil Phone: ++ 55 41 2169-1000 USA 3785 NW 82 Avenue Suite 211 Zip Code 33166 Doral - FL Phone: 305-913-7136 Goiânia R. T-55, 199 - Sl. 4 a 6 74150-320 - Goiânia - GO - Brazil Phone: ++ 55 62 3878-7700 Londrina R. Senador Souza Naves, 1510 86010-160 - Londrina - PR - Brazil Phone: ++ 55 43 3306-2000 Porto Alegre R. Félix da Cunha, 836 - Cj. 202 90570-000 - Porto Alegre - RS - Brazil Phone: ++ 55 51 3272-7400 Portugal Av. Defensores de Chaves, 15 - 3º D 1000-109 Lisboa - Portugal Phone: ++ (351) 21 013 4400 Recife R. Francisco Alves, 325 - Sl. 401 50070-490 - Recife - PE - Brazil Phone: ++ 55 81 3202-6900 Rio de Janeiro R. 2 de Dezembro, 38 - Cj. 302 a 305 22220-040 - Rio de Janeiro - RJ - Brazil Phone: ++55 21 3622-8900 São Paulo R. Francisco Leitão, 469 - Sl. 1809 05414-020 - São Paulo - SP - Brazil Phone: ++ 55 11 3728-2700 Vitória R. Cassiano Antônio Moraes, 100 - Loja 02 29050-525 - Vitória - ES - Brazil Phone: ++ 55 27 3203-5300

166

DISTRIBUTORS IN BRAZIL

Italy Bio-sfera Via C. Pavese, 50 Peschiera Borromeo – Mi Phone: 39 349 224 1190 Roberto.vernice@bio-sfera.com

Campo Grande – MS Alphadent Implantes e Instrumentais R. Padre João Cripa, 2385 – Bairro: Vila Alta CEP: 79010-180 Phone: (67) 3027-5993 / 0800 600 5993

Lebanon Implanet Dekwaneh Slaf Main Road Yervan Bldg - Beirut Phone: 961 169 2123 Implanet.ida@hotmail.com

Cuiabá – MT Alphadent Implantes e Instrumentais Phone: (67) 3027-5993 / 0800 601 5993 Av. São Sebastião, 2454 – Bairro: Popular CEP: 78045-400

Morocco Sarl Innov Mat Sect 2, Rue Al Missouak Nr 20 Hay Riad - Rabat Phone: 212 37 680892 / 212 61 228379 Coi@menara.ma

Florianópolis – SC Implantológica - Revenda Neodent Phone: (48) 3225-6069 / 0800 600 6069 R. Tenente Silveira, 713 – Centro CEP: 88.010-301 Manaus – AM A R. Rodriguez Phone: (92) 2121-7700 Av. Nabuco, 2235 CEP: 69.020-0z Salvador - BA Implante Way Produtos Médicos-Odontológicos Ltda Phone: 0800 284 5378 / Fax: (71) 3351-5378 Rua Senador Theotônio Vilela, 190 Ed. Convention Center , SL 506 - Pq Bela Vista BA CEP 40279-435

Paraguay D & D Distribuidora S.A Cap. Lezcano Esq Pascual Toledo 2321 Ruc 80025797-9 - Asunción Phone: 595 21 310 302 Comercial@dealer.com.py Dominican Republic Deposito Dental Idemefa S/a Calle Pedro A Bobea, Esq. Primera, Bella Vista Santo Domingo Phone: 809 535 2585 Idemefa@codetel.net.do Taiwan Hanns Dental Suply Company 2f 50 Fuxing N Road, 10488 Taipei - Taiwan Rov Phone: 852 254 01158 Celine.medcare@msa.hinet.net Venezuela Dental El Bosque Av. Universitaria Resd Diamante Local P.B. Valle Abajo - Caracas Phone: 58 212-6614280 / 6617790 / 6619497 Implantesneodent@gmail.com


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.