Interior & Exterior Signs & Graphics
October 14, 2011 Memorial Student Center, 300 Joe Routt Blvd. 1241 TAMU College Station, TX 7784
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Drawing Index PAGE NUMBER
01 02-04 05 06 07 08-12 13 14-16 17 18 19 20 21 22 23 24 25 26 27 28 29-32 33 34 35 36 37 38 39 40 41 42-46
SIGN TYPE
XA A S P R U Z W AA X L B C D E F G H XB N I J K BB CC, DD
DESCRIPTION
Index Performance Specification Bid Sheet Sign Location Plan - Basement Sign Location Plan - Level 1 Message Schedule Exterior Sign ID Interior Sign ID Main Concourse Enry Mural Café Wall Mural Café Soffit Mural Stairwell Mural Flex Murals Marketplace Cooler Display Small Dimensional Letters Marketplace Soffit Mural Textbook Vinyl Graphic Hours Sign Café Stanchion Hanging Department Sign Blade Sign Elevator Sign Directory Stanchion Promotional Graphic Exterior Dock Sign Textbook Wall Canvas Graphics Display Small Canvas Graphics Medium Canvas Graphics Large Canvas Graphics Illuminated Department Sign Adidas Store
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
DESCRIPTION
Index
P
01
QUANTITY
PERFORMANCE REQUIREMENTS / GENERAL CONDITIONS I.
dimensions or conditions, and/or changes required in construction details. Problems such as messages being too long to fit into the required formats, difficulty accurately reproducing logo or logotype components, etc., must be brought to the attention of the Owner and McGINTY prior to execution. It is required that the Contractor not resolve any discrepancies without consulting the Owner and McGINTY.
These Performance Requirements / General Conditions are an integral part of the Design Intent Document. The Contractor, sub-contractor and the General Contractor are responsible for all aspects of fabrication identified in this document. Any exclusions or substitutions to this document or to the Design Intent Drawings must be stated in writing to the Owner and to McGINTY at the time of bid.
II. PROPRIETARY INFORMATION NON-DISCLOSURE AGREEMENT All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for use on and in connection with the specific project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of McGINTY and the Owner. The Owner may have additional requirements or restrictions for which the Contractor is also responsible. The acceptance of these drawings by vendor, bidders, fabricators, or Contractors and their agents constitutes agreement to the following conditions: III. DESIGN INTENT BID DRAWINGS A. Design intent drawings are for the sole purpose of design intent only and not intended for construction purposes. B. Resulting working drawings, shop drawings and contract documents including permit documents are the sole responsibility of the Contractor in every respect. C. McGINTY shall review the shop drawings only for conformance with general design intent, and will in no way be responsible or liable for any results of construction from working drawings, material selection, shop drawings, contract documents or any other agreement other than agreement with the Owner authorizing these documents. D. Any Owner requested changes after this document has been completed will be considered additional services. IV. QUALITY ASSURANCE A. Quality of Workmanship: The Contractor shall be responsible for the quality and delivery of all materials and workmanship required for the execution of the contract including the materials and workmanship of any firms or individuals who act as his or her sub-Contractors. Contractors shall be responsible for providing sub-Contractors with complete and up-to-date drawings, performance and material requirements, graphic schedules and other information issued by McGINTY. B. Performance: The Contractor shall base his or her proposal on the performance of all services, including all items of labor, material and equipment required to complete fabrication and installation of specified work within the time frame agreed by the Contractor, Owner and McGINTY. C. Dimensions: Written dimensions on the drawings shall take precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions shown by these drawings. D. Sign Package Message Schedule: Copy, quantities and reference shown on the Message Schedule shall take precedence over drawings. The large scale details shall take precedence over the small scale drawings. E.
Execution: Contractor shall notify the Owner and McGINTY of any discrepancies in the drawings or Message Schedule, in field
F.
H. UL Compliance: Complete UL,, or approved nationally recognized testing agency, compliance, as required is the responsibility of the Contractor. Contractor shall provide lighting fixtures and electrical components that meet all UL testing lab requirements for safety, operation, and construction. Fixtures and components must be UL-labeled and listed and shall indicate locations and electrical service required for review by the Owner and McGINTY unless noted otherwise. Contractor is responsible for all final electrical connections.
J.
A.
Electrical Hardware: All transformers, LED power supplies, and electrical hardware shall be concealed, non-audible and non-visible to pedestrians and vehicular traffic. Provide disconnect switch if required by governing agencies.
Stock: All materials, hardware, electrical components, finishes, etc. used to fabricate any and all components shall be “NEW” (not previous used or operated in any other application) and from the most recent original manufacturer’s run/supply and appropriately matched to the service conditions required of the site.
M. Testing: An independent testing lab will be hired by the Owner to do inspection and material testing as required. Do no proceed with the work until unsatisfactory conditions have been corrected by the Contractor in a manner acceptable to the Owner.
Shop Drawings: The Contractor shall submit three sets of detailed shop drawings (2 sets of prints, 1 reproducible set of plans, elevations and scale drawings) to McGINTY and 1 reproducible set of plans plus 1 set of prints to the Owner for review prior to production. These drawings are to show/indicate all materials, finishes, construction details, lighting requirements, installation details, artwork and structure, including locations of all material seams (finished and unfinished). Shop drawings and data shall be reviewed by the Owner and McGINTY with such promptness as to cause no delay in the work. The Contractor shall make all corrections required and resubmit for final review. Final reviewed shop drawings noted “No Exceptions Taken” or “Exceptions as Noted” must be received from the Owner before production starts.
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Shop drawings will be reviewed for compliance with design intent only. The Contractor is responsible for engineering each object to meet all load and wind requirements with sealed drawings and calculations by certified engineers. The Contractor is responsible for all other aspects of fabrication including engineering, procedure, installation techniques and performance as well as coordination with site conditions and related trades. B.
Product Data: The Contractor shall submit manufacturer’s technical data and installation instructions for each fixture provided within the completed, installed unit. Contractor shall provide identification of all material used, including manufacturer’s descriptive literature, control number, name, code number, batch and formula (when available).
C.
Specific Samples: The Contractor shall submit a minimum of two (2) samples (minimum size 6” x 6” or as requested by McGINTY) of each color and finish on the specified materials. Samples must be submitted in a time frame allowable for review, multiple adjustments, and approval with out delay to the project. McGINTY review of samples will be for color, texture, and aesthetic compatibility with existing or adjacent materials. Compliance with all other requirements is the exclusive responsibility of the Contractors. When specified, furnish full-size samples of objects, partial objects, and/or materials. Resubmit samples if requested until required sheen, color, texture, and compliance with Fabricator Performance and Material Requirements is accepted.
Light Emission: All lighting fixtures/sources shall emit a color balanced, consistent and uniform light with no browning, flickering, haloing, or any other uneven effect.
K. Labeling: There shall be no visible labels, manufacturer’s or otherwise, code permitting, on the completed signs or other objects. If labels are required, a sample label and intended location along with an explanation of the requirement must be submitted for McGINTY and Owner review, prior to applications and/or installation. L.
SUBMITTALS
Contractor Recommendations: The Contractor shall carefully study the detail drawings and make recommendations for changes if those changes improve the quality of any fabrication. Such recommendations and changes including any changes in contract amount shall be approved in writing by the Owner and McGINTY prior to preparation of shop drawings or fabrication.
G. Artwork: Electronic artwork as required by the sign Contractor for symbols or custom designed graphic components (i.e.: logos, logo types, arrows, or patterns) will be provided in Mac-based Adobe Illustrator CS or EPS outlined format at full size. The digital artwork will be submitted via e-mail, FTP site or CD as appropriate. The appropriate Adobe Photoshop files will also be provided when necessary. All enlarging and reducing is the responsibility of the sign Contractor. Contractor shall submit an itemized list of all required artwork at time of bid. Note: Any artwork required beyond electronic computer artwork noted above (i.e.: additional custom copy layouts, formatting for other platform(s), linotronic output, or copying to other media, etc.) will be billed to the Contractor on a time and materials basis by McGINTY. McGINTY cannot provide copies of licensed fonts.
I.
V.
D.
E.
F.
Structure: Design installation, internal structure, mounting assemblies and foundations are by Contractor. Contractor shall submit three (3) sets of prints and one (1) reproducible set of comprehensive engineering drawings to McGINTY incorporating an adequate foundation and/or mounting structure for all sign components to meet all load and wind requirements and given site conditions. The Contractor shall, at his or her expense, submit for the Owner’s review, calculations, sealed by certified engineers registered in the state of final installation, for all structure members including foundations. Custom Fabricated Items: The Contractor is to submit shop drawings of all custom fabricated items and specifications on all standard pre-manufactured items. Electrical Requirements: Contractor shall, within five (5) days of contract execution, provide the Owner and General Contractor with a list of electrical requirements and support/blocking requirements for each element (including approximate weight).
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1
10.14.11
Draft Bid Set
2 3
SIGN TYPE
QUANTITY
DESCRIPTION
Performance Specification & General Conditions P
02
PERFORMANCE REQUIREMENTS / GENERAL CONDITIONS G.
H.
I.
J.
Lamp Service: The Contractor shall provide the Owner with complete lamp replacement information, brand, type, wattage, color, etc., for all lighted components. This information shall be in a typewritten format (8-1/2” x 11”) and shall indicate at least one (1) local (site) supplier. Maintenance: The Contractor shall provide the Owner with complete finish/ component care instructions as specified by the manufacturer for on-going cosmetic cleaning and maintenance. Three sets are to be submitted in an 8-1/2” x 11” 3-ring binder. Turn over to Owner one (1) unopened gallon of each color/finish used on the project clearly marked with complete specification and “P” color reference. Copy/Text Layouts: The Contractor shall provide full size copy layouts for all signs if noted on drawings. Layouts must be submitted in a time frame allowable for review, multiple adjustments and approval with out delay to the project. Large Format Digital Output: A 24” wide portion of the final fill size computer output of each image as well as a scaled-down proof of the entire image is required to be submitted to McGINTY for approval prior to final production.
E.
Ultra-Violet/Fading Protection: Contractor shall utilize materials, coatings and processes to minimize as much as possible any noticeable fading of pigmented coatings.
F.
Neon Returns: All exposed neon returns and double backs are to be opaque with a top coat to match the field area immediately behind that neon.
B.
C.
Colors and Surface Textures: All color shall match exactly the color and finish requirements provided by McGINTY. For exposed signage, materials with applied colors or other characteristics related to appearance, Contractor shall provide color matches indicated, or if not indicated, as selected and reviewed by McGINTY. Surface Preparation: All surfaces shall be thoroughly cleaned and free from dust, dirt, rust, scales, mill scales, oil, greasy materials or residue from cleaning. All coatings shall be applied in strict accordance with the manufacturer’s recommendations. All paint products shall conform to local (site) codes. All finishes shall present a uniform opaque color appearance unless specifically indicated otherwise by McGINTY. Paint Finishes: 1.
2.
3.
4.
D.
Ferrous Surfaces Using Matthews paint products, finish with one (1) coat 74734 & 74-735 Metal Pretreat @ .25 mils DFT, one (1) coat Matthews Acrylic Polyurethane 1.0 mil DFT (min.). Observe designer’s specifications regarding specularity (matte to gloss). Aluminum Using Matthews paint products, finish with one (1) coat 74734 & 74-735 Metal Pretreat @ .25 mils DFT or one (1) coat 74-793 Spray Bond @ .15 to .25 mils DFT and 1 coat Matthews Acrylic Polyurethane 1.0 mil DFT (min.).
A.
Acrylic Color Translucent Sheet: Where sheet material is indicated as “color” provide color translucent sheet of density required to produce uniform brightness without halo-like effect. Material provided shall be appropriately matched to the intended permanent field conditions.
B.
Acrylic/Transparent Sheet: Where sheet material is indicated as “clear” provide colorless sheet in gloss finish, with light transmittance of 92%, where tested in accordance with the requirements of ASTM D-1103.
C.
Aluminum Sheet: Provide aluminum sheet for alloy and temper recommended by the aluminum producer for finished for the type of use and finish indicated and with not less than the strength and durability properties specified in ASTM B109 for 5005-H15.
D.
E.
F.
G.
Application: All applications of color/coatings are to be equal and of consistent cover with no streaking, spotting, gradation, or other variations within and from each similar application.
C.
Signage/Cabinet: Details shown on the drawings shall be followed for exterior appearance. Structural design shall utilize unitized, self-supporting framing. Fabricate cabinet, exposed faces and graphic devices to size and styles indicated and produce surfaces free from oil canning, warping, distortion or any other irregularities or inconsistencies. Include internal bracing for stability and attachment of mounting accessories as required. Contractor may change interior construction shown on the details to conform with shop practices. However, these changes must be submitted as part of the shop drawings and be reviewed and accepted by McGINTY prior to fabrication.
D.
Fastening:
Aluminum Extrusions: Provide aluminum extrusions of alloy and temper recommended by the aluminum producer or finisher for the type of use and finish indicated and with not less than the strength and durability properties specified in ASTM B-221 for 6063-T5. Structural Steel: Provide internal structural steel as required to meet the requirements of the permanent installation. Fasteners: Unless otherwise indicated, provide concealed fasteners fabricated from metals that are non-corrosive to either the signage material or the mounting surface. Electrical/Lamps: Provide new electrical components and respective lamps, so as to be easily repaired or replaced from local available stock (24 hr. max. turn-around).
H.
Vinyl Machine Cut Copy/Graphics: Vinyl machine-cut copy and/or graphics shall be of 3M Scotchcal brand film or approved equal.
I.
Paint: Paint shall be Contractor’s highest grade for best ultraviolet light resistance, weatherability, and overall longevity of finish and color. Where possible, use water based, 100% solids, high performance acrylic instead of solvent-based paints. If solvent-based paint must be used, use products that are low-VOC (<380 g/l) and <1% aromatic hydrocarbons by weight. Paint shall have a written warranty against premature fading and be approved by McGINTY prior to construction. Prior to close-out, Contractor shall turn over to Owner three (3) copies of complete paint schedule indicating all colors used.
Bright Metals Match finish (polished, satin, brushed, etc. ) detailed in drawing. If specified, finish with a polyurethane clear coat warranteed against yellowing for seven years. Plastic Surfaces All plastic to be paint finish according to paint manufacturer’s specifications.
Illumination: Illuminate units in the manner indicated using the manufacturer’s standard lighting components including: LED, fluorescent, incandescent, and/or neon, fixtures, LED power supplies, transformers, ballasts, insulators and other components. Make provisions for servicing and for concealed connections to the building system. Coordinate all electrical components with those of the power supply provided. 4860 STERLING DRIVE BOULDER, CO 80301
VII. MATERIALS
VI. FINISHES A.
B.
1.
Fasteners on all visible surfaces shall not be exposed, except where noted.
2.
Surfaces shall not be penetrated during fabrication or installation, except where noted.
3.
Surfaces shall not be deformed, distorted, or discolored by attachment of concealed fasteners.
4.
All fasteners shall be resistant to oxidation or other corrosive action completely through their cross sections.
5.
Work shall be secured with fasteners of the same metal, color and finish as the component they secure where hey are exposed to view.
6.
E.
F.
Fasteners shall be utilized in strict accordance with their manufacturer’s specifications, directions, recommendations and as indicated on Design Intent Drawings.
Neon/Lamp: All exposed neon shall be installed in such a manner as to minimize double backs, exposed wires, etc. All exposed neon shall appear as a continuous line (4’ - 0” min. seamless runs) of light with no irregularities from section to section. Contractor shall coordinate with McGINTY to select exact color of neon and/or lamps. Contractor is responsible for referencing and following code constraints.
TEL 303 402 9233 FAX 303 402 9234
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE
Bid Drawings
Aluminum Sheet: Not less than 0.125” thick unless noted otherwise. Fabricate by the HELIARC or MIG welding process with all visible seams continuous welded, filled and ground smooth, unless the seam occurs along a color break. Then a clean butt joint with concealed backing channel and plug weld is finished to match surrounding finish. All blinds, curves, and folds to be geometrically correct and produced by a consistent mechanical methods unless approved otherwise by McGINTY.
REVISIONS
G.
Jointing and Brake Forming: All sheet material shall have brake formed edges with radii not greater than sheet thickness unless otherwise specified. Adjacent stock shall have edges of similar radii.
SIGN TYPE
H.
Welding: All exposed welds are to be ground smooth and filled to match surface of adjacent material.
VIII. FABRICATION
#
DATE
NOTES
1
10.14.11
Draft Bid Set
2 3
QUANTITY
DESCRIPTION
A.
Copy Application: Provide copy to comply with the requirements indicated for size, style, spacing, content, position, material, finish and color of letter, numbers, symbols and other graphic device.
Performance Specification General Conditions P
03
PERFORMANCE REQUIREMENTS / GENERAL CONDITIONS IX. INSTALLATION A.
B.
C.
D.
E.
F.
G.
H.
X.
B.
Contractor shall be responsible for determining the erection and dismantling of all barricade or protective coverings necessary to safeguard the public and property during the performance and duration of his or her work.
1.
Contractor shall attach objects to substrates in accordance with the project structural engineer’s and the manufacturer’s instructions unless otherwise shown. Install level, plumb, and at the proper height. Repair or replace damaged units as directed by the Owner or McGINTY. Visible abrasions to finished surfaces must be repaired so that damages is noted visible.
The Contractor will be responsible for any damage caused to building, site, and adjacent objects or elements during installation. The Contractor shall be responsible for cleaning up all work areas upon the completion of their work, on a daily basis.
Contractor shall be responsible for matching electrical service available on site to the requirements of the object, including transformers. All necessary electrical components as well as the entire assembly are to be UL listed, or by approved nationally recognized testing lab. Contractor is responsible for compliance with all applicable environmental regulations.
I.
Contractor is responsible for compliance with all OSHA regulations.
J.
Contractor shall be responsible for coordination of all elements with General Contractor, other sub-Contractors and trades people relative to this work. The coordination efforts will include, but not limited to: deliveries, work schedules, and installation. Storage space at the job site is limited and will also require coordination and/or approval. Materials or finished work stored a the job site without prior permission may be relocated at Contractor’s expense.
C.
D.
E.
F.
CLEANING, PROTECTION AND WARRANTIES A.
All items to be installed by the Contractor shall be left in a clean and as-new condition. Upon completion of the installation, clean all soiled surfaces and touch up all finishes in accordance with the manufacturer’s instructions. All debris and packaging material shall be removed and disposed of in a legal manner. The protective masking of the plastic surface shall be removed by the Contractor upon completion or installation. All excavation and site work shall be returned to its original grade configuration after contract items are installed.
No delamination or any portion of the object including vinyl graphics or copy.
B.
Contractor shall secure and pay for all insurance required by law including: Liability, Worker’s Compensation, Comprehensive, Construction Liability, Personal Injury, Comprehensive Auto and Property on- and off-site.
C.
Contractor shall not reveal or disseminate any information to any person(s), private or public, other than McGINTY, Owner or Contractor’s personnel necessary to execute the contract without first contacting the Owner for permission.
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Installation of all items shall be by the Contractor. Installation includes provisions of any required footings, all anchor bolts, fastenings, attachment metals, and other miscellaneous metal items embedded in concrete or building wall material as required, and security of unites in place with no visible fasteners.
The Contractor shall provide required electrical equipment and connection to shell building. The point of connection is to be provided by General Contractor. All electrical connections shall be made by a licensed electrician employed by the Contractor for this purpose. All connections shall be made in accordance with the requirements of the National Electrical Code (N.E.C.) in addition to all applicable local codes. Electrical Contractors shall provide and install all wiring, conduit, junction boxes and electrical devices necessary to provide electrical power to rough-in connections unless otherwise noted. Contractor shall provide concealed neon transformers and all electrical connections beyond rough-in connections by electrical Contractor, according to N.E.C. approved methods.
Finish Surfaces: All units shall be warranteed in writing by the Contractor for a period of no less than one (1) year from the date of Owner acceptance. All finishes (except large format computer output) are to be warranteed for three (3) years from the date of Owner acceptance. There shall be:
G.
No cupping, warping or dishing.
3.
No bubbling, crazing, chalking, rusting or other disintegration of surfaces, messages or edge finishes.
All high resolution large format computer output indicated in the Design Intent Document must comply with the following:
4.
No corrosion developing beneath the paint surface of the support system, except as the result of obvious vandalism.
1. Minimum resolution: 400 dpi, or as approved by McGINTY.
5.
No corrosion of fasteners.
6.
No movement of objects from their foundations. The objects must remain true and plumb on their foundations, except when obvious post-installation external damage has occurred.
7.
No fading of the colors when matched against a sample of the original color and material.
8.
No variation of any other performance stated by McGINTY on the drawings or in the Fabricator Performance and Material Requirements.
Structural/Components: Contractor shall provide Owner with three (3) copies of the written warrant prior to installation guaranteeing to correct, to Owner’s satisfaction, at Contractor’s sole expense, all defects in fabrication and installation of work for a period of one (1) year after the Owner’s acceptance of completed installation. External Lamps: All lamps shall be warranteed against failure for ninety (90) days, all neon for three (3) years, and all ballasts for one (1) year. Lamps are to be replaced within forty-eight (48) hours of notice by Owner and/or General Contractor. In the event of failure within specified times these items are to be replaced by Contractor at Contractor’s sole expense. Lamp Service: The Contractor shall provide Owner with three (3) copies and complete lamp replacement information, brand, type, wattage, color, etc., for all lighted components. This information shall be in a typewritten format (8-1/2” x 11”) and shall indicated at least one (1) local (site) supplier. Lamps must comply with all local, state, and federal regulations. Maintenance: The Contractor shall provide to Owner three (3) copies each of complete finish/component care instructions as specified by the manufacturer for on-going cosmetic cleaning and maintenance. These are to be submitted in an 8-1/2” x 11” 3-ring binder. Contractor to ensure signage, LED, neon, lamps, and electrical components etc. are easily accessible for maintenance. The Contractor shall have total and complete responsibility for the security of all equipment, materials and sign components until reviewed and accepted by Owner.
XI. PERMITS A.
XII. LARGE FORMAT COMPUTER OUTPUT
2.
Securing and paying for all permits required by governmental agencies is the responsibility of the Contractor. Inspection and tests necessary for the construction and placement of all work required by the applicable governing agencies is by the Contractor.
2. Process: 3M SCOTCHPRINT (or approved equal). 3. Substrate: Opaque or Translucent Scotchcal film (or approved equal) or fabric as specified. 4. Finish: 2 mil Matte overlaminate. 5. Input: Electronic art as specified. 6. Warranty: Product must be warranteed against color fading, UV damage, delamination, shrinkage or peeling for a minimum of five (5) years from date of installation. 7. Wall preparation (by General Contractor): Smooth drywall with eggshell finish acceptable. Prepare wall with two (2) coats of exterior grade, semi-gloss latex. Five (5) days dry time prior to application.. XIII. THE AMERICAN WITH DISABILITIES ACT REQUIREMENTS All signs must comply with ADA Guidelines and/or code requirements. A. Provide copy proofed braille to ADA guidelines for permanent room signs requiring Grade Two Braille. Required type and symbols must be raised a minimum of 1/32”.
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
B. Main type on permanent room signs must be raised a minimum of 1/32”.
DATE
C. Signs identifying permanent rooms or spaces must be mounted 60” from finish floor center of sign on the wall surface adjacent to the latch side of the door.
DRAWN BY / JE
D. Characters and backgrounds on ADA signage shall be eggshell, matte, or other non-glare finish. XIV. BID NOTES Original fabrication quotes shall be sent directly to the Owner with copies of all pricing information to be sent simultaneously to McGINTY and, if specified, to the General Contractor.
10.14.11
Bid Drawings REVISIONS #
DATE
NOTES
1
10.14.11
Draft Bid Set
2 3
Pricing shall be submitted in accordance with the bid documents. Bidders are required to clearly indicate in writing within their bid the method of construction anticipated, the materials to be used, and any exclusions or exceptions to the bid documents. Items not bid shall be marked “Not Bid”.
SIGN TYPE
QUANTITY
DESCRIPTION
Performance Specification & General Conditions P
04
BID SHEET: Signs
The Contractor is responsible for verifying the number of units required for each sign type and supplying either; 1) the unit quantity identified for each sign, or 2) quantity located on the installation drawings-which ever is HIGHER. 3) Indicate “not bid” on any items to be omitted from your bid.
Description
Sign Type
Quantity
Exterior ID Sign
XA
1
Exterior Dock ID
XB
2
Unit Cost
Extended Cost
Comments
4860 STERLING DRIVE BOULDER, CO 80301
Store ID
A
4
Hours Sign
B
4
Illuminated Café Stanchion
C
4
Department Sign
D
15
Blade Sign
E
33
Elevator ID
F
2
Directory Stanchion
G
2
Promotional Graphic
H
4
Small Canvas Graphic (20"x30")
I
29
Medium Canvas Graphic (28"x42")
J
15
Large Canvas Graphic (32"x48")
K
5
Mural Graphic (#001)
L
1
Mural Graphic (#007)
N
1
TEL 303 402 9233 FAX 303 402 9234
STANDARD SIGN HOLDER PROVIDED BY BARNES & NOBLE
CUSTOM GRAPHICS PROVIDED BY BUYENLARGE CUSTOM GRAPHICS PROVIDED BY BUYENLARGE CUSTOM GRAPHICS PROVIDED BY BUYENLARGE
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS
Mural Graphic (#036)
O
1
Mural Graphic (#105)
P
1
Café Mural Graphic (#111)
R
1
Mural Graphic or Dimensional Display (#129)
S
1
Mural Graphic (#144)
T
1
DRAWN BY / JE
Stair Mural Graphic (#147)
U
1
Bid Drawings
Mural Graphic (#174)
W
1
REVISIONS
Mural Graphic (#180)
X
1
PROJECT
#BNCO9013
DATE
10.14.11
#
DATE
NOTES
1
Mural Graphic (#106)
Y
1
Mural Graphic (#014, #017, #018, #020, #023)
Z
5
Mural Graphic (#188)
AA
1
Illuminated Department Sign
BB
1
Adidas Store Banner Sign
CC
2
Adidas Store Header Sign
CC
1
* Estimates to include taxes and delivery. Installation for murals only. Other signs to be installed by FFE/GC.
2 3
SIGN TYPE
DESCRIPTION
Bid Sheet Grand Total: Bidder Name:
Contact #:
P
05
QUANTITY
052 002
001
005
003
006
007
008
009
053 012
010
013
011
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
014 P
015 016 017
L
018 019 020
K
050
Texas A&M University
J
023 MH.8
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
H
DATE
024
049
025
DRAWN BY / JE
Bid Drawings
F
048
10.14.11
REVISIONS #
047
DATE
NOTES
1 2
D
3
026
SIGN TYPE
QUANTITY
046
045
044
043
042
041
040
039
038
037
036
035
034
033
032
029
M3
030
M4
5
7
13
14
16
19
23
26
30
36
39
027 028
031
Memorabilia - Murals, Prints and Blade Signs
DESCRIPTION
Sign Location Plan Basement Level
Signs - Wayfinding and Department P
06
109 101
102
103
104
105
106
107
108
111
113
110
115 114
117 116
119-122 118
126
123
125
127
124
128
130 129
132 131
134 133
135
189 136
138
137 184 183
139
182
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
140
181
141
180
142
179
143
178 177
145
176
146
175
147
185 174
148
Texas A&M University 149
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE
Bid Drawings REVISIONS
172
#
DATE
NOTES
1 2 3
171
157
156 191 170
169
168
167
188
166
165
164
163
162
161
187
160
159
154
155
SIGN TYPE
158
153 186
190
Memorabilia - Murals, Prints and Blade Signs
QUANTITY
150 DESCRIPTION
Sign Location Plan Level 1
Signs - Wayfinding and Department P
07
Sign #
Sign Type
Sign Description
Message Side A
Message Side B
001
L
Mural Graphic
(see drawing)
002
F
Elevator ID
Elevator (glyph)
003
K
Large Canvas Graphic
(see drawing)
004
OMIT
005
D
Department Sign
ONLINE ORDERS PICKUP
006
K
Large Canvas Graphic
(see drawing)
007
N
Mural Graphic
(see drawing)
008
OMIT
009
D
Department Sign
SCHOOL & ART SUPPLIES
SCHOOL & ART SUPPLIES
010
A
Store ID
011
C
Café Stanchion
012
E
Blade Sign
013
E
Blade Sign
014
Z
Mural Graphic
015
D
Department Sign
CUSTOMER SERVICES
CUSTOMER SERVICES
016
K
Large Canvas Graphic
(see drawing)
017
Z
Mural Graphic
018
Z
Mural Graphic
019
K
Large Canvas Graphic
020
Z
Mural Graphic
021
OMIT
022
D
Comments
Elevator (glyph) (48"x32") 4860 STERLING DRIVE BOULDER, CO 80301
ONLINE ORDERS PICKUP
TEL 303 402 9233 FAX 303 402 9234
(48"x32")
(32"x48")
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
(see drawing)
(32"x48")
DATE
10.14.11
DRAWN BY / JE
Bid Drawings
Department Sign
REVISIONS #
023
Z
Mural Graphic
024
I
Small Canvas Graphic
(see drawing)
(30"x20")
025
I
Small Canvas Graphic
(see drawing)
(30"x20")
026
K
Large Canvas Graphic
(see drawing)
(32"x48")
027
G
Directory Stanchion
028
E
Blade Sign
029
I
Small Canvas Graphic
(see drawing)
(30"x20")
030
I
Small Canvas Graphic
(see drawing)
(30"x20")
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
Standard B&N Stanchion. Sign frame provided by B&N DESCRIPTION
Message Schedule
P
08
Sign #
Sign Type
Sign Description
Message Side A
Message Side B
Comments
031
D
Department Sign
TEXTBOOKS
TEXTBOOKS
032
I
Small Canvas Graphic
(see drawing)
(30"x20")
033
I
Small Canvas Graphic
(see drawing)
(30"x20")
034
I
Small Canvas Graphic
(see drawing)
(30"x20")
035
I
Small Canvas Graphic
(see drawing)
(30"x20")
036
I
Mural
(see drawing)
(30"x20")
037
I
Small Canvas Graphic
(see drawing)
(30"x20")
038
D
Department Sign
TEXTBOOKS
TEXTBOOKS
039
D
Department Sign
CUSTOMER SERVICES
CUSTOMER SERVICES
040
I
Small Canvas Graphic
(see drawing)
(30"x20")
041
I
Small Canvas Graphic
(see drawing)
(30"x20")
042
I
Small Canvas Graphic
(see drawing)
(30"x20")
043
I
Small Canvas Graphic
(see drawing)
(30"x20")
044
I
Small Canvas Graphic
(see drawing)
(30"x20")
045
I
Small Canvas Graphic
(see drawing)
(30"x20")
046
I
Small Canvas Graphic
(see drawing)
(30"x20")
047
I
Small Canvas Graphic
(see drawing)
(30"x20")
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
048
I
Small Canvas Graphic
(see drawing)
(30"x20")
049
I
Small Canvas Graphic
(see drawing)
(30"x20")
050
XB
Dock ID
DRAWN BY / JE
051
XB
Dock ID
Bid Drawings
052
B
Hours Sign
REVISIONS
DATE
10.14.11
#
053
A
Store ID
DATE
NOTES
1 2 3
101
H
Promotional Graphic
102
E
Blade Sign
103
E
Blade Sign
104
C
Café Stanchion
105
P
Mural
SIGN TYPE
QUANTITY
DESCRIPTION
Message Schedule
P
09
Sign #
Sign Type
Sign Description
Message Side A
106
J
Medium Canvas Graphic
(see drawing)
107
E
Blade Sign
108
F
Elevator ID
109
E
Blade Sign
Elevator
Message Side B
Comments (42"x28")
Elevator 4860 STERLING DRIVE BOULDER, CO 80301
110
E
Blade Sign
111
R
Café Mural
112
OMITTED
113
OMITTED
114
E
Blade Sign
115
J
Medium Canvas Graphic
116
E
Blade Sign
117
J
Medium Canvas Graphic
118
E
Blade Sign
119
J
120
TEL 303 402 9233 FAX 303 402 9234
(see drawing)
(42"x28")
(see drawing)
(42"x28")
Medium Canvas Graphic
(see drawing)
(28"x42")
J
Medium Canvas Graphic
(see drawing)
(28"x42")
121
J
Medium Canvas Graphic
(see drawing)
(28"x42")
122
J
Medium Canvas Graphic
(see drawing)
(28"x42")
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
123
H
Promotional Graphic
124
D
Deparment Sign
125
A
Store ID
DRAWN BY / JE
126
B
Hours Sign
Bid Drawings
127
E
Blade Sign
DATE
CHECKOUT
10.14.11
REVISIONS #
128
E
Blade Sign
129
S
Mural or dimensional display
130
E
Blade Sign
131
E
Blade Sign
132
E
Blade Sign
133
I
Small Canvas Graphic
(see drawing)
(30"x20")
134
I
Small Canvas Graphic
(see drawing)
(30"x20")
135
I
Small Canvas Graphic
(see drawing)
(30"x20")
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
DESCRIPTION
Message Schedule
P
10
Sign #
Sign Type
Sign Description
Message Side A
Message Side B
Comments
136
I
Small Canvas Graphic
(see drawing)
(30"x20")
137
I
Small Canvas Graphic
(see drawing)
(30"x20")
138
I
Small Canvas Graphic
(see drawing)
(30"x20")
139
D
Department Sign
140
I
Small Canvas Graphic
(see drawing)
(30"x20")
141
I
Small Canvas Graphic
(see drawing)
(30"x20")
142
E
Blade Sign
143
E
Blade Sign
144
OMITTED
145
G
Directory Stanchion
146
E
Blade Sign
147
U
Stair Mural
148
J
Medium Canvas Graphic
(see drawing)
(42"x28")
149
J
Medium Canvas Graphic
(see drawing)
(42"x28")
150
E
Blade Sign
151
OMITTED
152
OMITTED
153
E
Blade Sign
154
E
Blade Sign
155
E
Blade Sign
DRAWN BY / JE
156
E
Blade Sign
Bid Drawings
157
C
Café Stanchion
REVISIONS
158
B
Hours Sign
159
XA
Exterior ID Sign
160
E
Blade Sign
161
E
Blade Sign
162
E
Blade Sign
163
D
Department Sign
CHECKOUT
164
J
Medium Canvas Graphic
(see drawing)
(28"x42")
165
J
Medium Canvas Graphic
(see drawing)
(42"x28")
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Standard B&N Stanchion. Sign frame provided by B&N
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
#
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
DESCRIPTION
Message Schedule
P
11
Sign #
Sign Type
Sign Description
Message Side A
Message Side B
Comments
166
J
Medium Canvas Graphic
(see drawing)
(42"x28")
167
E
Blade Sign
168
E
Blade Sign
169
J
Medium Canvas Graphic
(see drawing)
(42"x28")
170
J
Medium Canvas Graphic
(see drawing)
(42"x28")
171
J
Medium Canvas Graphic
(see drawing)
(42"x28")
172
J
Medium Canvas Graphic
(see drawing)
(42"x28")
173
OMITTED
174
W
Dimensional letter display
[LOGO] TEXAS A&M UNIVERSITY [LOGO]
175
D
Department Sign
AGGIE STOP
AGGIE STOP
176
D
Department Sign
CUSTOMER SERVICES
CUSTOMER SERVICES
177
B
Hours Sign
178
E
Blade Sign
179
E
Blade Sign
180
X
Mural
181
E
Blade Sign
182
A
Store ID
183
C
Café Stanchion
185
BB
Illuminated Department Sign
186
H
Promotional Graphic
DRAWN BY / JE
187
H
Promotional Graphic
Bid Drawings
188
AA
Small Dimensional Letters
189
CC
Adidas Store Banner Sign
190
DD
Adidas Store Header Sign
191
CC
Adidas Store Banner Sign
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
AGGIE STOP
AGGIES
AGGIE STOP
DATE
10.14.11
REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
DESCRIPTION
Message Schedule
P
12
15'-8"
1'-108"
1/2"
1/2"
X 14
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
8 9/16" 1"
1
Elevation Detail: Main Exterior Sign Scale: 3/4"=1'-0"
19
16
14
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
1 13
2 14
10.14.11
DRAWN BY / JE, PY
16'-9" (VIF)
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
9'-0"
1'-4 1/2"
1"
2'-0"
11'-3 3/4"
SIGN TYPE
QUANTITY
XA DESCRIPTION
Exterior ID Sign
1
Elevation: Main Exterior Sign Scale: 3/16"=1'-0"
P
13
1
2 1/2" deep dimensional letter, non-illuminated. Letters mechanically fasten to mounting bracket with concealed fastener 1/4" metal letter. Painted Matthews Brushed Aluminum. Mount to face of dimensional letter. 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
REQUIRE SECTION OF COLUMN Metal letter mounting bracket. Painted Dark Metallic Grey (TBD). Fasten to top of sign cabinet.
3
Side View Scale: 1 1/2"=1'-0"
See sheet 13 for mounting location
2
2 1/2" deep dimensional letter. Letters are NOT illuminated. Letters mounted to back panels with concealed fasteners. Color: Dark metallic gray (T.B.D.)
Attachment Detail Scale: 1 1/2"=1'-0"
2 1/2" square support tube anchored to ceiling. Color: Matthews Brushed Aluminum
Adjacent column. Opp. Hand Sim.
Letter mounting bracket. Color: Dark metallic gray (T.B.D.) 1" x 1/2" top and bottom cap. Color: match "Aggie Maroon" school color (T.B.D.)
9'-0"
1/4" painted aluminum dimensional letter mounted flush to sign cabinet. Color: Matthews Brushed Aluminum 6" deep painted aluminum sign cabinet. Cabinet is NOT illuminated. Color: match "Aggie Maroon" school color (T.B.D.)
2
Scale: 1/4"=1'-0"
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
Support tubes anchor to vertical concrete column.
Section: Main Exterior Sign
Texas A&M University
3
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
1
4.21.11
2 3
SIGN TYPE
QUANTITY
XA DESCRIPTION
Exterior ID Sign
Side View Scale: 1 1/2"=1'-0"
NOTES
P
14
1
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Texas A&M University
1 16
14 16
EXTERIOR / INTERIOR SIGNS & GRAPHICS
17
19
20
23
24
PROJECT
#BNCO9013
DATE
10.14.11
AT TEXAS A M UNIVERSITY
OPEN TO STAIRS
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
FIXED PANEL
9'-0"
FIXED PANEL
STORE HOURS
MOND MON DAY– THURSDAY, 8AM– 6PM FRID FRI D AY, 8AM– 5PM www.tamu.bncollege.com
X
DATE
NOTES
1 2
X
3
SIGN TYPE
QUANTITY
A1
1
DESCRIPTION
1
Elevation: Store ID - Main Concourse Entry (#125) Scale: 1/4"=1'-0"
NOTE: FINAL STORE IDENTITY TO BE DETERMINED (SEE PAGE 13 FOR OPTIONS)
#125 Store ID Main Concourse Entrance P
15
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
REQUIRE SECTION OF ENTRY
1
Elevation Detail: Typical Entry Sign Scale: 3/4"=1'-0"
Texas A&M University
Internally illuminated dimensional letters
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
10'-0"
White acrylic push-through letters Internally illuminated sign box
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1'-11 1/4"
1'-1"
1 2 3
AT TEXAS A M UNIVERSITY
SIGN TYPE
QUANTITY
A1
1
DESCRIPTION
1
Elevation Detail: Main Concourse Entry Scale: 3/4"=1'-0"
Store ID Main Concourse & Café Marketplace Entries P
16
1 18
L
K
4'-0"
EQ
J
3'-0"
AT TEXAS A M UNIVERSITY
9'-0"
FIXED PANEL
FIXED PANEL
www.tamu.bncollege.com
4860 STERLING DRIVE BOULDER, CO 80301
TM X
3
AT
STORE HOURS
MONDAY–THURSDAY, 8AM–6PM FRIDAY, 8AM–5PM
TEL 303 402 9233 FAX 303 402 9234
X
Elevation: Café Marketplace Entry Scale: 1/4"=1'-0"
7
EQ
1 18
4'-0"
EQ
10
EQ
AT TEXAS A M UNIVERSITY X
FIXED PANEL
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
2 M4.2
1 18
DATE
Elevation: Lower Level Concourse Entry (continued)
10.14.11
Scale: 1/4"=1'-0"
DRAWN BY / JE, PY
4'-0"
EQ
M4.8
5
6
7
3'-7 1/2"
Bid Drawings REVISIONS #
DATE
NOTES
1
AT TEXAS A M UNIVERSITY
2
TM
9'-0"
3
FIXED PANEL
X
X
FIXED PANEL SIGN TYPE
A2 DESCRIPTION
1
Elevation: Lower Level Concourse Entry
Store ID Lower Level Concourse & Café Marketplace Entrance
Scale: 1/4"=1'-0"
P
17
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
REQUIRE SECTION OF INTERIOR CEILING & WINDOW ARCADE
1
Elevation Detail: Typical Entry Sign Scale: 3/4"=1'-0"
Internally illuminated dimensional letters
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
10'-0"
White acrylic push-through letters
DATE
10.14.11
DRAWN BY / JE, PY
Internally illuminated sign box
Bid Drawings REVISIONS #
DATE
NOTES
1'-11 1/4"
1'-1"
1 2 3
AT TEXAS A M UNIVERSITY
SIGN TYPE
QUANTITY
A2
3
DESCRIPTION
Store ID
1
Elevation Detail: Typical Entry Sign Scale: 3/4"=1'-0"
P
18
5'-10 3/8"
“Bevel” created by masking and sandblasting 4860 STERLING DRIVE BOULDER, CO 80301
Satin Brushed Natural Aluminum #6257 applied to 1/4” acrylic with returns painted black.
4'-10"
TEL 303 402 9233 FAX 303 402 9234
2
Elevation Detail: Main Concourse Entry Mural
3
Scale: NTS Provide plywood blocking to accept A&M Logo Display
26'-2"
Detail: A&M Logo Display Scale: 3/4” = 1’-0” Scotchprint graphic applied to finished wall.
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
8'-8 5/8"
12th Man The tradition of the Twelfth Man was born on the second of January 1922, when an underdog Aggie team was playing Centre College, the nation's top ranked team at the time. As the hard fought game wore on, the Aggies were forced to dig deep into their limited reserves because of injuries. Coach Dana X. Bible remembered that a former squad member, who was playing basketball at the time, was in the press box helping reporters identify players. His name was E. King Gill. Gill was called from the stands, suited up, and stood ready throughout the rest of the game… which A&M finally won 22-14. When the game ended, E. King Gill was the only man left standing on the sidelines for the Aggies. Gill later said, "I wish I could say that I went in and ran for the winning touchdown, but I didn't. I simply got ready and waited--just in case I was needed."This gesture was more than enough for the Aggie Team. Although Gill did not play in the game, he had accepted the call to help his team. He came to be known as the “Twelfth Man” because he stood ready for in case the eleven men on the gridiron needed him. That spirit of readiness for service, desire to support, and enthusiasm helped kindle a flame of devotion among the entire student body; a spirit that has grown vigorously throughout the years. The entire student body at A&M is the Twelfth Man, and they stand during the entire game to show their support. The 12th Man is always in the stands waiting to be called upon if needed.This tradition took on a new look in the 1980's when Coach Jackie Sherrill started the 12th Man Kick-Off Team, composed of regular students through open tryouts. This 12th Man team performed very well and held opponents to one of the lowest yards per return averages in the league. Later, Head Coach R.C. Slocum changed the team to allow only one representative of the 12th Man on the kick-off team. The 12th Man tradition exists also in musical form; the student body sings “The Twelfth Man” after each game in which the Aggies are outscored. Midnight Yell Yell Practice began as a post dinner activity in early 1900’s, when different corps companies would gather together to "learn heartily the old time pep." However, it was not until 1931, that Midnight Yell Practice, as it is known today, was held before the t.u. game. It began, when a group of cadets were gathered in Peanut Owen's dorm room in Puryear Hall. Someone suggested that all of the freshmen should fall out and meet on the steps of the YMCA building at midnight. The cadets notified senior yell leaders Horsefly Berryhill and Two Gun Parker of their intents. Although it could not officially be authorized, they said they may just show up. Needless to say, the word spread quickly, and when the freshmen began to arrive, there were railroad flares and torpedoes stuck in flower pots around the YMCA building to light the area. The first Midnight Yell had begun!!! Today, Midnight Yell is held the night before a home game in Kyle Field and at the Arches on Thursday nights before away games. Also for an away game, a site is designated for a Midnight Yell in the city of our opponent the night before the game. For example, for the t.u. game, it is held at the Texas Capitol in Austin. For a yell at Kyle Field, yell leaders lead the Fightin' Texas Aggie Band and the Twelfth Man into the stadium. The yell leaders lead the crowd in old army yells, the school’s songs, and tell fables of how the Aggies are going to beat the everlivin' hell out of our opponent. Finally, the lights go out, and Aggies kiss their dates. If they don't have a date, all they have to do is “flick their Bic.” As the story goes, the flames make it easier for two dateless people to find a kiss!The purpose of Midnight Yell is to pump up the Twelfth Man for the next day's big game!Gig 'em Pinky Downs, class of 1906 and a member of the Board of Regents from 1923 to 1933, is credited with the Gig ‘Em hand sign. At the 1930 Yell Practice before the TCU football game, Downs shouted out, "What are we going to do to those Horned Frogs?" Answering his own question, he replied, “Gig ‘Em, Aggies!” while making a fist with his thumb extended. A “gig” is a spear-like tool used for hunting frogs. The gesture became known as the first hand sign of The Southwest Conference. Howdy "Howdy" is the official greeting of Texas A&M University. It is our way of ensuring that no one feels like a stranger. The exact origin on this tradition is not known. However, "Howdy" is what sets us apart as the friendliest campus in the world. Bonfire The first Aggie Bonfire began in the early 1900's as a pile of wood and trash next to the train station. The cadets decided to make a Bonfire to congratulate the football team on their win. Although this first Bonfire was held in the early morning hours of November 18, 1907, the first on-campus Aggie Bonfire was not held until 1909. Bonfire grew immensely through the years. The largest Bonfire was in 1969 and stood 109ft., which is only one foot shorter than Rudder tower. After that, the administration decided to regulate the Bonfire height to 55ft. There have been two years that Bonfire did not burn. First, in 1963, following the death of President John F. Kennedy, the senior class made one of the most difficult decision of their time at Texas A&M. In honor of their president, they decided to dismantle the Bonfire, which had recently been completed. The head yell leader at the time, Mike Marlowe, was quoted as saying, "It is the most we have and the least we can give." The second time that Bonfire was built and did not burn was in 1999. On November 18th, Bonfire fell, taking 12 of our fellow Aggies with it. This day was one of the most trying days for Aggies everywhere. At this time, Bonfire has been postponed indefinitely and no one knows if Bonfire will return. The Aggie Spirit has created the Aggie Traditions and that Aggie Spirit will thrive through the trying times. Reveille Reveille, the first lady of Aggieland, is the official mascot of Texas A&M University. She is the highest ranking member of the Corps of Cadets, and she is a Five-Star General. Reveille I came to Texas A&M in January 1931. A group of cadets hit a small black and white dog on their way back from Navasota. They picked up the dog and brought her back to school so they could care for her. The next morning, when "Reveille" was blown by a bugler, she started barking. She was named after this morning wakeup call. The following football season she was named the official mascot when she led the band onto the field during their half-time performance. When Reveille I died on January 18, 1944, she was given a formal military funeral on the gridiron of Kyle Field. She was then buried at the north entrance to the field, as all Reveilles are, facing the scoreboard so that she can always watch the Aggies outscore their opponent. Before naming Reveille II, there were several other unofficial mascot, such as Tripod, Spot, and Ranger. It was not until a later Reveille that she was a full-blood Collie. The most current Reveille is Reveille VIII, and she was officially introduced on August 30, 2008. Reveille is the most revered dog on campus. Company E-2 has the privilege of taking care of Reveille. If she is sleeping on a cadet's bed, that cadet must sleep on the floor. Cadets address Reveille as "Miss Rev, m'am." If she is in class and barks while the professor is teaching, the class is to be immediately dismissed. Reveille is a highly cherished mascot and receives only the best. Silver TapsBy far, one of Texas A&M's most honored traditions is Silver Taps. Silver Taps is held for a graduate or undergraduate student who passes away while enrolled at A&M. This final tribute is held the first Tuesday of the month following the students’ passing. The first Silver Taps was held in 1898 and honored Lawrence Sullivan Ross, the former governor of Texas and president of A&M College. Silver Taps is currently held in Academic Plaza. On the day of Silver Taps, a small card with the deceased students name, class, major, and date of birth is placed at the base of the Academic Plaza flagpole, and the Silver Taps Memorial located behind the flagpole. Around 10:15 that night, the lights are extinguished and hymns chime from Albritton Tower. Students silently gather at the statue of Lawrence Sullivan Ross. At 10:30pm, the Ross Volunteer Firing Squad marches into the plaza and fires a twenty-one gun salute. Buglers then play a special rendition of Silver Taps, by Colonel Richard Dunn, three times from the dome of the Academic Building: once to the north, south, and west. It is not played to the east because it is said that the sun will never rise on that Aggies life again. After the buglers play, the students leave from Academic Plaza in complete silence. Silver Taps is a sacred tradition that Aggies treasure dearly. Replant It is one of the largest student-run, enviromental service projects in the nation. It was orginally developed by Scott Hantman to replenish some of the trees cut for the Bonfire. In the Spring of 1991, he joined Bonfire leaders and planted 400 trees. In 1994, it became a SGA committee that works year-round coordinating the event. They are sponsored by Texas A&M, the National Tree Trust, and the Army Corps of Engineers at Lake Somerville.Thousands of trees are planted each year by hundreds of student volunteers from A&M and the Bryan/College Station area. Trees are planted at local parks, schools, and other public land properties. All trees are donated by the National Tree Trust (between 500-10,000 per year). Corps Texas A&M was established as a military institution, and the Corps of Cadets has played an important part in its history and development. Although membership in the Corps became voluntary in 1965, Texas A&M historically has produced more military officers than any other institution in the nation, except for the service academies. More than 200 of its graduates have become generals or admirals. More Aggies were commissioned and fought in World War II than men from West Point or Annapolis.The Corps of Cadets at Texas A&M is not just another ROTC unit that might be found at most campuses. The 2,200 men and women of the Corps form the largest uniformed body of students outside the U.S. military academies. Although cadets can earn commissions as military officers, membership in the Corps itself carries no military obligation. In fact, only about 30 percent of graduating cadets are commissioned, while the rest pursue civilian careers. The Corps has more to offer than just military training. It is a tightly-knit group of students that offers camaraderie, as well as leadership training that is useful in all post-college careers.Texas A&M has rich military history. More than 200 of its graduates have become generals or admirals. More Aggies were commissioned and fought in World War II than men from West Point or Annapolis. Aggie Ring One of the greatest moments in the life of every Aggie is the day that he or she receives an Aggie Ring. This tradition began with the Class of 1889. The original rings were very different from the one worn today because, at that time, several companies made different versions of the Aggie Ring. E. C. Jonas, Class of 1894, designed a ring that is similar to the ring worn today. There have been only slight changes to this design, with one exception; in 1964, the Legislature of the State of Texas changed the university's name from the Agricultural and Mechanical College of Texas to Texas A&M University, and the name on the ring was changed accordingly.The Aggie Ring is one of the most symbolic of our traditions. Everything seen on the ring represents a value that an Aggie should hold. On the top is a large shield, which symbolizes the desire to protect the reputation of the university. The 13 stripes on the shield represent the 13 original states of America. The five stars on the shield refer to the phases of development of any Aggie: mind or intellect; body; spiritual attainment; emotional poise; and integrity of character.The eagle symbolizes agility and power, and the ability to reach great heights. The large star on the side of the ring symbolizes the Seal of Texas. The five-pointed star is encircled with a wreath of olive and laurel leaves symbolizing achievement and a desire for peace. The live oak leaves symbolize the strength to fight for our country and our state. The leaves are joined at the bottom by an encircling ribbon to show the necessity of uniting these two traits to accomplish one's ambition to serve. An ancient cannon, a saber, and a rifle are on the other side of the ring and symbolize how citizens of Texas fought for their land and are determined to defend it. The saber stands for valor and confidence, while the rifle and cannon stand for a preparedness and defense. The crossed flags of the United States and Texas recognize an Aggie's dual allegiance to both nation and state. Traditionally, students wear their ring with the class year facing them to signify the fact that their time at A&M is not yet complete. During Senior Week at the annual Ring Dance, the student's ring is turned around to face the world proudly, just as the Aggie graduate will be ready to face the world. Muster Aggies gathered together on June 26, 1883 to live over again their college days, the victories and defeats won and lost upon the drill field and classroom. Eventually the annual gathering evolved into a celebration of Texas Independence on San Jacinto Day – April 21st. Over time the tradition has changed, but its very essence has remained “If there is an A&M man in one hundred miles of you, you are expected to get together, eat a little, and live over the days you spent at the A&M College of Texas.” Muster is celebrated in more than four hundred places worldwide, with the largest ceremony on the Texas A&M campus in College Station. Aggie Muster as we know it today is credited to E. E. McQuillen ’20, who served as the Executive Secretary of The Association of Former Students. It is fitting that he was honored to serve as the first Campus Muster speaker. This year we are privileged to have Mrs. Brooke Leslie Rollins ’94 to serve as the 2007 Campus Muster speaker. The committee was recognized as a student organization in 1950. Like the tradition itself, the committee has transcended the eras and events throughout its history and remained true to the timeless ideals of Muster. The Muster Committee is responsible for organizing and planning every aspect of the tradition, from speaker to barbeque, awareness to the Roll Call – this committee continues the livelihood of this great tradition year after year. The committee falls under the discretion of the Student Government Association. The 2007 Muster Committee is composed of 22 committee members, seven sub-chairs, and one chair. Their tasks vary among the five subcommittees: Awareness, Programs, Roll Call and Families, Speaker Selection, and Special Operations.Muster is a time to look to the past, present, and future…not only to grieve but to reflect and to celebrate the lives that connect us to one another. A gesture so simple in nature yet so lasting in spirit, Muster is the lasting impression every Aggie leaves with us; it reminds us of the greatness that lies within these walls, of the loyalty we possess, of the connection that binds us, and of the idea that every Aggie has a place of importance – whether they are present in flesh or spirit.Big Event The Big Event is the largest, one-day, student-run service project in the nation where students of Texas A&M University come together to say ‘thank you’ to the residents of Bryan and College Station. For the past 25 years Aggie students have participated in this annual event to show their appreciation to the surrounding community by completing service projects such as yard work, window washing, and interior/exterior painting. Although The Big Event has become the largest one-day, student-run service project in the nation, our message still remains the same – simply “thank you.”
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
S
1
DESCRIPTION
1
Elevation: Main Concourse Entry Mural Scale: 3/16"=1'-0"
Mural Graphic #129 P
19
376" 140"
Corner of Wall
4860 STERLING DRIVE BOULDER, CO 80301
108"
TEL 303 402 9233 FAX 303 402 9234
FLATSCREEN
3
Elevation: Café Wall Mural #105 (elevation flattened) Scale: 3/8"=1'-0"
L
42
39
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
NOTES
9'-8"
2
7'-3/16"
9’-0"
FLATSCREEN
3
11'-8" (140”)
1
DATE
1
9'-8"
11'-0"
Provide plywood blocking behind to accept Flatscreen mounting bracket
East Elevation: Café Wall Mural #105 Scale: 1/4"=1'-0"
19'-8" (236”)
2
SIGN TYPE
QUANTITY
P
1
DESCRIPTION
Café Wall Mural #105
North Elevation: Café Wall Mural #105 Scale: 1/4"=1'-0"
P
20
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
2'-0" 8"
60'-10"
Elevation Detail: Café Mural #111 (elevation flattened)
2
Texas A&M University
Scale: 3/16"=1'-0"
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
Soffit curves
Mural continues 8 inches up behind mini soffit
10.14.11
3M Scotchprint applied directly to painted surface
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
2'-8"
1 2
9'-0"
9'-8"
3
SIGN TYPE
QUANTITY
R
1
DESCRIPTION
Café Mural #111
1
Elevation: Café Mural #111 Scale: 3/16"=1'-0"
P
21
Drafterâ&#x20AC;&#x2122;s Notes: Walll Section Detail Pending & New Graphic Pending 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
H
G
F
24'-3" 4'-1 1/8"
Scotchprint mural applied to painted wall
15'-4 1/2"
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
U
1
DESCRIPTION
Stairwell Mural #147 OPTION 1
1
Elevation: Stairwell Mural #147 (Option 1) Scale: 1/4"=1'-0"
P
22
11 1/2"
3/8â&#x20AC;? Acrylic letters mounted flush to Scotchprint covered wall. Secure tightly to prevent removal
1
Detail - Dimensional Letters
Color: Paint to match Aggie Maroon with high gloss finish
Scale: 3/16"=1'-0" H
G
F
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
24'-3" Scotchprint mural applied to painted wall
4'-1 1/8"
15'-4 1/2"
Texas A&M University
11'-3/4"
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
U
1
DESCRIPTION
1
Elevation: Stairwell Mural #147 (Option 2)
Stair Mural Graphic #147 Option 2
Scale: 1/4"=1'-0"
P
23
3/8" White Sintra
Neon
Open-face, aluminum can letters.
6"
1'-6 1/2"
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
1'-7 1/2"
20"
Attached directly to wall with visible bolts through back of letter.
Vinyl applied to surfaceof Sintra logo Color: to match Aggie Maroon
Electrical required for neon
2
Detail: Reverse Pan Channel Letter (RPC)
3
Scale: 1 1/2"=1'-0"
Detail: RPC Letter - Illuminated
4
Scale: 1 1/2"=1'-0"
End View: RPC Letter - Illuminated Scale: 1 1/2"=1'-0"
5
Detail: A&M Logo Scale: 1 1/2"=1'-0"
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS
39
42 5 23
2 23
45 2 23
46 2 23
48 5 23
PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
1'-4"1'-4"
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
W
1
DESCRIPTION
Market Place Mural #174
1
Elevation: Marketplace Mural #174 Scale: 3/16"=1'-0"
P
23
3'-6"
4860 STERLING DRIVE BOULDER, CO 80301
9'-6"
TEL 303 402 9233 FAX 303 402 9234
#014
2
#017
#018
#020
#023 Texas A&M University
Elevation Details: Lower Level Flex Spirit Shop
EXTERIOR / INTERIOR SIGNS & GRAPHICS
Scale: 1/2"=1'-0" PROJECT
M?
L
K
J
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
3'-6"
Bid Drawings REVISIONS #
DATE
NOTES
1
4.21.11
UPDATED ELEVATION
2
10'-0" 9'-0" 9'-6"
3
SIGN TYPE
QUANTITY
Z
5
DESCRIPTION
Flex Area Spirit Shop
1
School Supplies
Mural Graphic #174 ?
Elevation: Lower Level Flex Spirit Shop Scale: 3/16"=1'-0"
P
24
Open-face, aluminum can letters.
4" 4860 STERLING DRIVE BOULDER, CO 80301
1'-0"
Backs of letters mechanically fasten to raised fins on attachment band.
2
Elevation Detail: RPC Letter - Non-Illuminated Scale: 1 1/2"=1'-0"
11?
3
Side View: RPC Letter - Non-Illuminated Scale: 1 1/2"=1'-0"
eq.
eq.
4
TEL 303 402 9233 FAX 303 402 9234
Detail: Attachment band Scale: 1 1/2"=1'-0"
30?
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
AA
1
DESCRIPTION
Small Dimensional Letters #188
1
Elevation: Small Dimensional Letters #188 Scale: 3/8"=1'-0"
P
25
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Elevation Detail: Marketplace Soffit Mural #180 Scale: NTS
22'-0"
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
2'-8"
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS
9'-8"
2
#
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
X
1
DESCRIPTION
1
Elevation: Marketplace Soffit Mural #180 Scale: 3/8"=1'-0"
Mural Graphic #180 P
26
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Gray Vinyl Applied to painted wall Color: TBD
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
L
1
DESCRIPTION
1
Elevation: Textbook Wall Graphic Mural #001 Scale: 3/8"=1'-0"
Mural Graphic #001 P
27
NOTE: Standard B&N Superstores sign
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
8 1/2 x 11" Paper sign insert Sign holder and template to be provided by B&N College FINAL HOURS TO BE DETERMINED
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
AT TEXAS A M UNIVERSITY
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
B
4
DESCRIPTION
Hours Sign
1
Elevation Detail: Hours Sign Scale: 3"=1'-0" P
28
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
NOTE: New Starbucks logo pending input from Starbucks Corporate
3'-0"
6" 2'-8"
Typical notes for a standard Barnes & Noble (36" x 45") illuminated double-sided cafe sign
2'-7 "
Routed out aluminum faces with show through "Barnes & Noble" and pushed through "Cafe" copy with white vinyl on 2nd surface.
1'-7 1/2"
3'-9 "
"Starbucks" logo is translucent white plex with applied vinyl graphics applied first surface.
FPO
TM
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS
Sign internally illuminated with fluorescent lamps. 6" minimum sign thickness regardless of sign size. Hidden switch.
PROJECT
#BNCO9013
DATE
10.14.11
3'-10"
2" square structural aluminum tube supports. Color: Color: MP18149
DRAWN BY / JE, PY
Bid Drawings
Weighted base for stability.
REVISIONS #
DATE
NOTES
1
8’-cord and plug to adjacent wall outlet
2 3
SIGN TYPE
QUANTITY
C
4
1'-8"
3'-7 1/2"
DESCRIPTION
Illuminated Café Stanchion
1
Elevation: Café Stanchion - Illuminated Scale: 3/4"=1'-0"
2
Side View: Café Stanchion - Illuminated Scale: 3/4"=1'-0"
P
29
NEED SECTION AT CEILING
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Stainless steel cable fastened to ceiling or to blocking above ceiling as appropriate. 3/4" aluminum sleeve covers cable Ceiling conditions vary. Verify ceiling condition for each sign location. Sleeve color: MP19891 - Airstream Sparkle Metallic
1 1/4"
6'-0"
2
Section Detail: Attachment Detail Scale: 1 1/2"=1'-0"
1 1/4" Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
10 1/2"
1 1/4"
Millwork cap Paint MP19891 Airstream Sparkle Metallic
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings
10'-3/4"
1/8" painted Sintra panels (2) Mount panels to 1"x1" painted square tube frame with concealed fasteners. Panel color: Paint panels and frames to match Aggie Maroon
Suspend 8'-0" above floor
REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
D DESCRIPTION
Department Sign
1
Elevation Detail: Department Sign Scale: 1 1/2"=1'-0"
2
End View: Department Sign Scale: 1 1/2"=1'-0"
P
30
15
2"
22"
2"
2"
3/8” Sintra panel Color: painted to match Aggie Maroon
4860 STERLING DRIVE BOULDER, CO 80301
18"
Panel applied to 2” painted tube frame Color: painted to match PMS Cool Gray 11 metallic 5 31
2"
18 1/2"
4 31
Elevation Detail: Blade Sign
3
Scale: 1 1/2"=1'-0"
14
16
2 31
End View: Blade Sign Scale: 1 1/2"=1'-0"
4
Section Detail: Mounting Bracket
5
Scale: 3"=1'-0"
19
Section Detail: Mounting Scale: 3"=1'-0"
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
7'-0"
1
6 1/2"
2
10'-0"
22"
TEL 303 402 9233 FAX 303 402 9234
2 3
SIGN TYPE
QUANTITY
E
33
DESCRIPTION
Blade Sign
P
31
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
012
013
028
102
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
103
107
109
110
#BNCO9013
DATE
10.14.11
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
E 114
1
116
118
127
DESCRIPTION
Blade Sign
Blade Sign Art Scale: NTS
P
32
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
#128
130
131
132
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
142
143
146
150
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
E 153
1
Blade Sign Art Scale: NTS
154
155
ON CORNER COLUMN AT ADIDAS STORE
156
DESCRIPTION
Blade Sign
ON CORNER COLUMN AT ADIDAS STORE P
33
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
160
161
162
167
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
168
178
179
181
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
E DESCRIPTION
Blade Sign
1
Blade Sign Art Scale: NTS
P
34
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Section Detail: Mounting Bracket
4
Scale: 3"=1'-0"
Section Detail: Mounting Scale: 3"=1'-0"
High resolution digital output mounted to painted Sintra panel
1'-6"
2"
5
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS
2"
PROJECT
#BNCO9013
Bracket attached to wall with hidden fastners
DATE
10.14.11
Painted MP19891 Airstream Sparkle Metallic
DRAWN BY / JE, PY
7'-9 1/2"
1'-6"
1/8" painted Sintra panels (2) Mount panels to 2"x2" painted square tube frame with concealed fasteners.
5 31
Bid Drawings REVISIONS #
DATE
NOTES
1
Panel color: Paint panels and frames to match Aggie Maroon 4 31
2 3
SIGN TYPE
QUANTITY
F
2
DESCRIPTION
Elevator ID
1
Elevation: Elevator ID Scale: 3/8"=1'-0"
2
Elevation Detail: Elevator ID Scale: 1 1/2"=1'-0"
3
End View: Elevator ID Scale: 1 1/2"=1'-0"
P
35
NOTE: Standard B&N College Stanchion
23”
Sign holder provided by B&N
23” 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
YOU ARE ON THE
YOU ARE ON THE
MAIN LEVEL
YOU ARE ON THE
MAIN LEVEL
LOWER LEVEL
• Checkout • General Reading • Reference
MAIN LEVEL
• Bargain • Kids Books • World News & • • • •
Periodicals Marketplace Café Customer Services Restrooms
MAIN LEVEL
• Textbooks
LOWER LEVEL
• On-line Order Pickup • School and Art Supplies • Computer Supplies
• Checkout
• Checkout
• General Reading
• General Reading
• Reference
• Reference
• Bargain
• Bargain
• World News & • •
• Prints and Frames • Buyback
MAIN LEVEL
• Kids Books
• •
Periodicals Marketplace Café Customer Services Restrooms
57” AT TEXAS A M UNIVERSITY
tamu.bncollege.com
LOWER LEVEL
• School and Art Supplies
• World News &
Periodicals
• Marketplace • Café • Customer Services • Restrooms
• Textbooks • On-line Order Pickup
• Kids Books
• Textbooks
LOWER LEVEL
57”
• Computer Supplies • Prints and Frames • Buyback
EACH SIGN DOUBLE SIDED SAME ART ON EACH SIDE
• On-line Order Pickup • School and Art Supplies • Computer Supplies • Prints and Frames • Buyback
Digital print with clear protective laminate mounted to 1/8” Sintra panel. BID INSERT PANEL ONLY STANCHIONS EXIST ON SITE.
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings REVISIONS #
DATE
NOTES
1
FPO Only Store ID TBD AT TEXAS A M UNIVERSITY
AT TEXAS A M UNIVERSITY
tamu.bncollege.com
tamu.bncollege.com
2 3
SIGN TYPE
QUANTITY
G
2
DESCRIPTION
Directory Stanchion
1
Directory Stanchion Scale: NTS
2
Elevation Detail: Level 1 Directory Stanchion Scale: 1 1/2"=1'-0"
3
Elevation Detail: Level 1 Directory Stanchion Scale: 1 1/2"=1'-0"
P
36
3'-0" 33 1/2"
B&N to provide 4 double-sided LED light boxes for retail partners to promoteproducts. 50 1/2"
6'-0"
CEILING SECTION REQUIRED
B&N POSTER GRAPHIC AREA
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
3’ x 6’ double-sided LED Light Box. Suspended from ceiling by steel cables. The LED Two Side Premium Light Box: DSA/Phototech
AT TEXAS A M UNIVERSITY
• 1 5/8” deep • Easy change graphics with snap front frame • Bright, even illumination powered by LED’s
tamu.bncollege.com
• Silver or Black finishes • Custom finishes also available • Stainless steel support cables included • UL listed Section: Attachement Detail
2
2
Scale: 3/4"=1'-0"
14.15.16.
19.
17.
Elevation Detail: Promotional Graphics
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
Scale: 3/4"=1'-0"
#BNCO9013
20.
2 37
23.
24.
DATE
10.14.11
DRAWN BY / JE
Bid Drawings REVISIONS #
BACK TO
SCHOOL FIXED PANEL
NOTES
1 2
9'-0"
FIXED PANEL
DATE
STORE HOURS
MOND MON DAY– THURSDAY, 8AM– 6PM FRID FRI D AY, 8AM– 5PM www.tamu.bncollege.com
3 AT TEXAS A M UNIVERSITY
tamu.bncollege.com X
X
2'-0"
1
Elevation: Promotional Graphics Scale: 1/4"=1'-0"
3'-11"
2'-0" 4'-0"
SIGN TYPE
QUANTITY
H
4
DESCRIPTION
MEN'S RESTROOM
Promotional Graphic
P
37
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Painted aluminum panel 30"
AT TEXAS A M UNIVERSITY
Panel color: Paint face and sides to match Aggie Maroon Satin clear coat to protect from graffiti
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
30"
DRAWN BY / JE, PE
RECEIVING
White type Screened to panel
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
XB
QUANTITY
2
DESCRIPTION
Exterior Dock Sign
1
Elevation Detail: Loading Dock Sign Scale: 1 1/2"=1'-0"
P
38
PRODUCED BY BUYENLARGE
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
66"
Digital output on stretched canvas. Mount flush face of wall. Field verify for condition.
Texas A&M University
2
Elevation Detail: Canvas Graphic Display #007
EXTERIOR / INTERIOR SIGNS & GRAPHICS
Scale: 3/4"=1'-0"
PROJECT
#BNCO9013
eq.
eq.
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1 2
5'-3/8"
3
SIGN TYPE
QUANTITY
N
1 set
DESCRIPTION
1
Elevation: Canvas Graphic Display #007 Scale: 1/4"=1'-0"
Canvas Graphic Display #007 P
39
7
10
#032
13
#033
#035
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
1
Elevation: Lower Level Concourse Entry Scale: 1/4"=1'-0"
14
13 #035
16
19
#037
23
#040
#041
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
1
12.20.10
Elevation: Lower Level Concourse Entry
DRAWN BY / JE
Scale: 1/4"=1'-0"
Bid Drawings 23
26 #043
30 #044
36 #045
39 #046
REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
I
31
DESCRIPTION
1
Elevation: Lower Level Concourse Entry Scale: 1/4"=1'-0"
Small Canvas Graphic 20’ x 30’ P
40
PRODUCED BY BUYENLARGE
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Sign #024
Sign #025
Sign #029
Sign #030
Sign #032
Sign #033
Sign #035
Sign #034
Sign #037
Sign #040
30"
20"
Sign #041
1
Sign #042
Sign #043
Sign #044
Sign #045
Sign #046
Sign #047
Sign #048 Sign #049
Elevation: Lower Level Concourse Entry
Texas A&M University
Scale: 1/4"=1'-0"
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings
F
REVISIONS #
#029
#030
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
I
31
DESCRIPTION
1
Elevation: Lower Level Concourse Entry Scale: 1/4"=1'-0"
Small Canvas Graphic 20’ x 30’ P
41
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Sign #133
Sign #136
Sign #138
Sign #137
2 1
Sign #134
Sign #140
Sign #141
Tradebook Area Wall Graphics
Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.
Scale: 3/4"=1'-0"
Sign #135
Sign #184 No #184 on Sign Location Plan FOUND
Elevation: Lower Level Concourse Entry
Texas A&M University
Scale: 1/4"=1'-0"
EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS
MAYBE WE SHOULD JUST SHOW ONE TYPICAL SIGN PLACEMENT ELEVATIONS INSTEAD OF REPEATING THE SIGN LOCATIONS PLAN IN ELEVATIONS
#
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
I
31
DESCRIPTION
1
Elevation: Scale: 1/4"=1'-0"
Small Canvas Graphic 20’ x 30’ P
42
Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.
42"
PRODUCED BY BUYENLARGE
4860 STERLING DRIVE BOULDER, CO 80301
28"
TEL 303 402 9233 FAX 303 402 9234
Sign #106
3
36
Sign #115
Sign #117
Elevation Detail: Power Aisle Wall Graphics Scale: 3/4"=1'-0"
30
26
23
#115
#117
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY /JE, PY
7
2
Elevation: Lower Level Concourse 10 Scale: 3/16"=1'-0"
13
K
14
16
Bid Drawings5 H
J
36
39 #106
19
REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
J
16
DESCRIPTION
Medium Canvas Graphic
1
Elevation: Lower Level Concourse Scale: 3/16"=1'-0"
P
43
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Sign #148
Sign #149
Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.
1
19
Sign #169
Sign #170
PRODUCED BY BUYENLARGE
Elevation: Lower Level Concourse
Sign #164
Sign #172 16
Scale: 3/16"=1'-0"
D
Sign #171
14 F
#164
G
#171
H
#172
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
10.14.11
DRAWN BY / JE, PY
3 G
Elevation: Lower Level Concourse 7
10
23
Scale: 3/16"=1'-0"
F
4
Elevation: Lower Level Concourse 26 3/16"=1'-0" Scale: D
#148
14
13 30
#149
#169
#170
16
19
Bid Drawings 36
REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
J
16
DESCRIPTION
Medium Canvas Graphic
1
Elevation: Lower Level Concourse Scale: 3/16"=1'-0"
2
Elevation: Lower Level Concourse Scale: 3/16"=1'-0"
P
44
Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.
PRODUCED BY BUYENLARGE
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Sign #165
4
Sign #166
Elevation Detail: Kid’s Department Wall Graphic Scale: 3/4"=1'-0"
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS
Sign #119
3
Sign #120
Sign #121
Sign #122
PROJECT
#BNCO9013
Elevation Detail: Customer Service #1 Backwall Graphic
DATE
10.14.11
Scale: 3/4"=1'-0"
DRAWN BY / JE, PY
23
L
26
30
36
K
Bid Drawings REVISIONS
#165
#166
#119
#120
#121
#122
#
DATE
NOTES
1 2 3
SIGN TYPE
QUANTITY
J
16
DESCRIPTION
Medium Canvas Graphic
1
Elevation: Kid’s Department Wall Graphic Scale: 3/16"=1'-0"
2
Elevation: Customer Service #1 Backwall Graphic Scale: 3/16"=1'-0"
P
45
Stainless steel cable fastened to ceiling or to blocking above ceiling as appropriate. 3/4" aluminum sleeve covers cable
White acrylic push-through letters
Ceiling conditions vary. Verify ceiling condition for each sign location. Sleeve color: MP19891 - Airstream Sparkle Metallic 5'-6"
7" 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
10 1/2" Aluminum sign cabinet. Paint all sides of cabinet to match Aggie Maroon
11"
AGGIE STOP
Suspend 7'-2" above floor
2
Texas A&M University
Elevation Detail: Hanging Departement Sign - Illuminated
3
Scale: 1 1/2â&#x20AC;?=1'-0"
J
H
G
EXTERIOR / INTERIOR SIGNS & GRAPHICS
End View: Handing Department Sign - Illuminated Scale: 1 1/2"=1'-0"
F
PROJECT
#BNCO9013
E
DATE
10.14.11
DRAWN BY / JE, PY
Bid Drawings
AGGIE STOP
REVISIONS #
DATE
NOTES
1
FIXED PANEL
FIXED PANEL X
2 3
X
SIGN TYPE
BB
QUANTITY
1
DESCRIPTION
4'-0"
1
Illuminated Department Sign
Elevation: Level 1 Entry Scale: 1/4"=1'-0"
P
46
PRODUCED BY BUYENLARGE
48" 4860 STERLING DRIVE BOULDER, CO 80301
32"
TEL 303 402 9233 FAX 303 402 9234
Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.
Sign #003
Sign #006
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS #
Sign #016
Sign #019
Sign #026
DATE
NOTES
1 2 3
1
SIGN TYPE
QUANTITY
K
5
Textbook Area Wall Graphics Scale: 3/4"=1'-0"
DESCRIPTION
Large Canvas Graphic
P
47
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
DESCRIPTION
Adidas Store
P
48
QUANTITY
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
SIGN TYPE
DESCRIPTION
Adidas Store
P
49
QUANTITY
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Header Graphic
Floor-to-ceiling panel graphic 8'-3 1/4"
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS
LAY-IN CEILING
PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS #
HARD CEILING
DATE
NOTES
1 2 3
Logo Blade Sign
Floor-to-ceiling panel graphic
SIGN TYPE
DESCRIPTION
Adidas Store
P
50
QUANTITY
2'-6"
Scotchprint graphic appled to aluminum panel.
4860 STERLING DRIVE BOULDER, CO 80301
.09 Aluminum Panel applied to 3/8” Sintra panel Color: Painted BLACK
TEL 303 402 9233 FAX 303 402 9234
1” x 2” painted tube frame Color: painted BLACK
8'-6"
Sign is double-sided GRAPHIC FOR POSITION ONLY TO BE PROVIDED BY ADIDAS
Aircraft cable attaches sign to hard ceiling. Verify field conditions
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings
Aircraft cable anchors to floor
REVISIONS #
DATE
NOTES
1 2 3
1
Adidas Store Graphic Panel Scale: 3/8"=1'-0"
2
Adidas Store Graphic Panel Scale: 3/8"=1'-0"
3
Side View Scale: 3/8"=1'-0"
SIGN TYPE
CC DESCRIPTION
Adidas Store Banner Sign P
51
QUANTITY
2
Aircraft cable attaches sign to hard ceiling. Verify field conditions
4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234
Scotchprint graphic appled to aluminum panel.
1'-5"
GRAPHIC TO BE PROVIDED BY ADIDAS
8'-0"
2
Adidas Store Graphic Panel Scale: 3/8"=1'-0"
.09 Aluminum Panel applied to 3/8” Sintra panel Color: Painted BLACK 1” x 2” painted tube frame Color: painted BLACK
Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT
#BNCO9013
DATE
12.20.10
DRAWN BY / JE
Bid Drawings REVISIONS #
DATE
NOTES
1 2 3
1
Adidas Store Graphic Panel Scale: 3/8"=1'-0"
3
Side View
SIGN TYPE
DD
Scale: 3/8"=1'-0"
DESCRIPTION
Adidas Store Topper Sign P
52
QUANTITY
1