Barnesnoble txam

Page 1

Interior & Exterior Signs & Graphics

October 14, 2011 Memorial Student Center, 300 Joe Routt Blvd. 1241 TAMU College Station, TX 7784


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Drawing Index PAGE NUMBER

01 02-04 05 06 07 08-12 13 14-16 17 18 19 20 21 22 23 24 25 26 27 28 29-32 33 34 35 36 37 38 39 40 41 42-46

SIGN TYPE

XA A S P R U Z W AA X L B C D E F G H XB N I J K BB CC, DD

DESCRIPTION

Index Performance Specification Bid Sheet Sign Location Plan - Basement Sign Location Plan - Level 1 Message Schedule Exterior Sign ID Interior Sign ID Main Concourse Enry Mural Café Wall Mural Café Soffit Mural Stairwell Mural Flex Murals Marketplace Cooler Display Small Dimensional Letters Marketplace Soffit Mural Textbook Vinyl Graphic Hours Sign Café Stanchion Hanging Department Sign Blade Sign Elevator Sign Directory Stanchion Promotional Graphic Exterior Dock Sign Textbook Wall Canvas Graphics Display Small Canvas Graphics Medium Canvas Graphics Large Canvas Graphics Illuminated Department Sign Adidas Store

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

DESCRIPTION

Index

P

01

QUANTITY


PERFORMANCE REQUIREMENTS / GENERAL CONDITIONS I.

dimensions or conditions, and/or changes required in construction details. Problems such as messages being too long to fit into the required formats, difficulty accurately reproducing logo or logotype components, etc., must be brought to the attention of the Owner and McGINTY prior to execution. It is required that the Contractor not resolve any discrepancies without consulting the Owner and McGINTY.

These Performance Requirements / General Conditions are an integral part of the Design Intent Document. The Contractor, sub-contractor and the General Contractor are responsible for all aspects of fabrication identified in this document. Any exclusions or substitutions to this document or to the Design Intent Drawings must be stated in writing to the Owner and to McGINTY at the time of bid.

II. PROPRIETARY INFORMATION NON-DISCLOSURE AGREEMENT All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for use on and in connection with the specific project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of McGINTY and the Owner. The Owner may have additional requirements or restrictions for which the Contractor is also responsible. The acceptance of these drawings by vendor, bidders, fabricators, or Contractors and their agents constitutes agreement to the following conditions: III. DESIGN INTENT BID DRAWINGS A. Design intent drawings are for the sole purpose of design intent only and not intended for construction purposes. B. Resulting working drawings, shop drawings and contract documents including permit documents are the sole responsibility of the Contractor in every respect. C. McGINTY shall review the shop drawings only for conformance with general design intent, and will in no way be responsible or liable for any results of construction from working drawings, material selection, shop drawings, contract documents or any other agreement other than agreement with the Owner authorizing these documents. D. Any Owner requested changes after this document has been completed will be considered additional services. IV. QUALITY ASSURANCE A. Quality of Workmanship: The Contractor shall be responsible for the quality and delivery of all materials and workmanship required for the execution of the contract including the materials and workmanship of any firms or individuals who act as his or her sub-Contractors. Contractors shall be responsible for providing sub-Contractors with complete and up-to-date drawings, performance and material requirements, graphic schedules and other information issued by McGINTY. B. Performance: The Contractor shall base his or her proposal on the performance of all services, including all items of labor, material and equipment required to complete fabrication and installation of specified work within the time frame agreed by the Contractor, Owner and McGINTY. C. Dimensions: Written dimensions on the drawings shall take precedence over scaled dimensions. Contractor shall verify and be responsible for all dimensions and conditions shown by these drawings. D. Sign Package Message Schedule: Copy, quantities and reference shown on the Message Schedule shall take precedence over drawings. The large scale details shall take precedence over the small scale drawings. E.

Execution: Contractor shall notify the Owner and McGINTY of any discrepancies in the drawings or Message Schedule, in field

F.

H. UL Compliance: Complete UL,, or approved nationally recognized testing agency, compliance, as required is the responsibility of the Contractor. Contractor shall provide lighting fixtures and electrical components that meet all UL testing lab requirements for safety, operation, and construction. Fixtures and components must be UL-labeled and listed and shall indicate locations and electrical service required for review by the Owner and McGINTY unless noted otherwise. Contractor is responsible for all final electrical connections.

J.

A.

Electrical Hardware: All transformers, LED power supplies, and electrical hardware shall be concealed, non-audible and non-visible to pedestrians and vehicular traffic. Provide disconnect switch if required by governing agencies.

Stock: All materials, hardware, electrical components, finishes, etc. used to fabricate any and all components shall be “NEW” (not previous used or operated in any other application) and from the most recent original manufacturer’s run/supply and appropriately matched to the service conditions required of the site.

M. Testing: An independent testing lab will be hired by the Owner to do inspection and material testing as required. Do no proceed with the work until unsatisfactory conditions have been corrected by the Contractor in a manner acceptable to the Owner.

Shop Drawings: The Contractor shall submit three sets of detailed shop drawings (2 sets of prints, 1 reproducible set of plans, elevations and scale drawings) to McGINTY and 1 reproducible set of plans plus 1 set of prints to the Owner for review prior to production. These drawings are to show/indicate all materials, finishes, construction details, lighting requirements, installation details, artwork and structure, including locations of all material seams (finished and unfinished). Shop drawings and data shall be reviewed by the Owner and McGINTY with such promptness as to cause no delay in the work. The Contractor shall make all corrections required and resubmit for final review. Final reviewed shop drawings noted “No Exceptions Taken” or “Exceptions as Noted” must be received from the Owner before production starts.

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Shop drawings will be reviewed for compliance with design intent only. The Contractor is responsible for engineering each object to meet all load and wind requirements with sealed drawings and calculations by certified engineers. The Contractor is responsible for all other aspects of fabrication including engineering, procedure, installation techniques and performance as well as coordination with site conditions and related trades. B.

Product Data: The Contractor shall submit manufacturer’s technical data and installation instructions for each fixture provided within the completed, installed unit. Contractor shall provide identification of all material used, including manufacturer’s descriptive literature, control number, name, code number, batch and formula (when available).

C.

Specific Samples: The Contractor shall submit a minimum of two (2) samples (minimum size 6” x 6” or as requested by McGINTY) of each color and finish on the specified materials. Samples must be submitted in a time frame allowable for review, multiple adjustments, and approval with out delay to the project. McGINTY review of samples will be for color, texture, and aesthetic compatibility with existing or adjacent materials. Compliance with all other requirements is the exclusive responsibility of the Contractors. When specified, furnish full-size samples of objects, partial objects, and/or materials. Resubmit samples if requested until required sheen, color, texture, and compliance with Fabricator Performance and Material Requirements is accepted.

Light Emission: All lighting fixtures/sources shall emit a color balanced, consistent and uniform light with no browning, flickering, haloing, or any other uneven effect.

K. Labeling: There shall be no visible labels, manufacturer’s or otherwise, code permitting, on the completed signs or other objects. If labels are required, a sample label and intended location along with an explanation of the requirement must be submitted for McGINTY and Owner review, prior to applications and/or installation. L.

SUBMITTALS

Contractor Recommendations: The Contractor shall carefully study the detail drawings and make recommendations for changes if those changes improve the quality of any fabrication. Such recommendations and changes including any changes in contract amount shall be approved in writing by the Owner and McGINTY prior to preparation of shop drawings or fabrication.

G. Artwork: Electronic artwork as required by the sign Contractor for symbols or custom designed graphic components (i.e.: logos, logo types, arrows, or patterns) will be provided in Mac-based Adobe Illustrator CS or EPS outlined format at full size. The digital artwork will be submitted via e-mail, FTP site or CD as appropriate. The appropriate Adobe Photoshop files will also be provided when necessary. All enlarging and reducing is the responsibility of the sign Contractor. Contractor shall submit an itemized list of all required artwork at time of bid. Note: Any artwork required beyond electronic computer artwork noted above (i.e.: additional custom copy layouts, formatting for other platform(s), linotronic output, or copying to other media, etc.) will be billed to the Contractor on a time and materials basis by McGINTY. McGINTY cannot provide copies of licensed fonts.

I.

V.

D.

E.

F.

Structure: Design installation, internal structure, mounting assemblies and foundations are by Contractor. Contractor shall submit three (3) sets of prints and one (1) reproducible set of comprehensive engineering drawings to McGINTY incorporating an adequate foundation and/or mounting structure for all sign components to meet all load and wind requirements and given site conditions. The Contractor shall, at his or her expense, submit for the Owner’s review, calculations, sealed by certified engineers registered in the state of final installation, for all structure members including foundations. Custom Fabricated Items: The Contractor is to submit shop drawings of all custom fabricated items and specifications on all standard pre-manufactured items. Electrical Requirements: Contractor shall, within five (5) days of contract execution, provide the Owner and General Contractor with a list of electrical requirements and support/blocking requirements for each element (including approximate weight).

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1

10.14.11

Draft Bid Set

2 3

SIGN TYPE

QUANTITY

DESCRIPTION

Performance Specification & General Conditions P

02


PERFORMANCE REQUIREMENTS / GENERAL CONDITIONS G.

H.

I.

J.

Lamp Service: The Contractor shall provide the Owner with complete lamp replacement information, brand, type, wattage, color, etc., for all lighted components. This information shall be in a typewritten format (8-1/2” x 11”) and shall indicate at least one (1) local (site) supplier. Maintenance: The Contractor shall provide the Owner with complete finish/ component care instructions as specified by the manufacturer for on-going cosmetic cleaning and maintenance. Three sets are to be submitted in an 8-1/2” x 11” 3-ring binder. Turn over to Owner one (1) unopened gallon of each color/finish used on the project clearly marked with complete specification and “P” color reference. Copy/Text Layouts: The Contractor shall provide full size copy layouts for all signs if noted on drawings. Layouts must be submitted in a time frame allowable for review, multiple adjustments and approval with out delay to the project. Large Format Digital Output: A 24” wide portion of the final fill size computer output of each image as well as a scaled-down proof of the entire image is required to be submitted to McGINTY for approval prior to final production.

E.

Ultra-Violet/Fading Protection: Contractor shall utilize materials, coatings and processes to minimize as much as possible any noticeable fading of pigmented coatings.

F.

Neon Returns: All exposed neon returns and double backs are to be opaque with a top coat to match the field area immediately behind that neon.

B.

C.

Colors and Surface Textures: All color shall match exactly the color and finish requirements provided by McGINTY. For exposed signage, materials with applied colors or other characteristics related to appearance, Contractor shall provide color matches indicated, or if not indicated, as selected and reviewed by McGINTY. Surface Preparation: All surfaces shall be thoroughly cleaned and free from dust, dirt, rust, scales, mill scales, oil, greasy materials or residue from cleaning. All coatings shall be applied in strict accordance with the manufacturer’s recommendations. All paint products shall conform to local (site) codes. All finishes shall present a uniform opaque color appearance unless specifically indicated otherwise by McGINTY. Paint Finishes: 1.

2.

3.

4.

D.

Ferrous Surfaces Using Matthews paint products, finish with one (1) coat 74734 & 74-735 Metal Pretreat @ .25 mils DFT, one (1) coat Matthews Acrylic Polyurethane 1.0 mil DFT (min.). Observe designer’s specifications regarding specularity (matte to gloss). Aluminum Using Matthews paint products, finish with one (1) coat 74734 & 74-735 Metal Pretreat @ .25 mils DFT or one (1) coat 74-793 Spray Bond @ .15 to .25 mils DFT and 1 coat Matthews Acrylic Polyurethane 1.0 mil DFT (min.).

A.

Acrylic Color Translucent Sheet: Where sheet material is indicated as “color” provide color translucent sheet of density required to produce uniform brightness without halo-like effect. Material provided shall be appropriately matched to the intended permanent field conditions.

B.

Acrylic/Transparent Sheet: Where sheet material is indicated as “clear” provide colorless sheet in gloss finish, with light transmittance of 92%, where tested in accordance with the requirements of ASTM D-1103.

C.

Aluminum Sheet: Provide aluminum sheet for alloy and temper recommended by the aluminum producer for finished for the type of use and finish indicated and with not less than the strength and durability properties specified in ASTM B109 for 5005-H15.

D.

E.

F.

G.

Application: All applications of color/coatings are to be equal and of consistent cover with no streaking, spotting, gradation, or other variations within and from each similar application.

C.

Signage/Cabinet: Details shown on the drawings shall be followed for exterior appearance. Structural design shall utilize unitized, self-supporting framing. Fabricate cabinet, exposed faces and graphic devices to size and styles indicated and produce surfaces free from oil canning, warping, distortion or any other irregularities or inconsistencies. Include internal bracing for stability and attachment of mounting accessories as required. Contractor may change interior construction shown on the details to conform with shop practices. However, these changes must be submitted as part of the shop drawings and be reviewed and accepted by McGINTY prior to fabrication.

D.

Fastening:

Aluminum Extrusions: Provide aluminum extrusions of alloy and temper recommended by the aluminum producer or finisher for the type of use and finish indicated and with not less than the strength and durability properties specified in ASTM B-221 for 6063-T5. Structural Steel: Provide internal structural steel as required to meet the requirements of the permanent installation. Fasteners: Unless otherwise indicated, provide concealed fasteners fabricated from metals that are non-corrosive to either the signage material or the mounting surface. Electrical/Lamps: Provide new electrical components and respective lamps, so as to be easily repaired or replaced from local available stock (24 hr. max. turn-around).

H.

Vinyl Machine Cut Copy/Graphics: Vinyl machine-cut copy and/or graphics shall be of 3M Scotchcal brand film or approved equal.

I.

Paint: Paint shall be Contractor’s highest grade for best ultraviolet light resistance, weatherability, and overall longevity of finish and color. Where possible, use water based, 100% solids, high performance acrylic instead of solvent-based paints. If solvent-based paint must be used, use products that are low-VOC (<380 g/l) and <1% aromatic hydrocarbons by weight. Paint shall have a written warranty against premature fading and be approved by McGINTY prior to construction. Prior to close-out, Contractor shall turn over to Owner three (3) copies of complete paint schedule indicating all colors used.

Bright Metals Match finish (polished, satin, brushed, etc. ) detailed in drawing. If specified, finish with a polyurethane clear coat warranteed against yellowing for seven years. Plastic Surfaces All plastic to be paint finish according to paint manufacturer’s specifications.

Illumination: Illuminate units in the manner indicated using the manufacturer’s standard lighting components including: LED, fluorescent, incandescent, and/or neon, fixtures, LED power supplies, transformers, ballasts, insulators and other components. Make provisions for servicing and for concealed connections to the building system. Coordinate all electrical components with those of the power supply provided. 4860 STERLING DRIVE BOULDER, CO 80301

VII. MATERIALS

VI. FINISHES A.

B.

1.

Fasteners on all visible surfaces shall not be exposed, except where noted.

2.

Surfaces shall not be penetrated during fabrication or installation, except where noted.

3.

Surfaces shall not be deformed, distorted, or discolored by attachment of concealed fasteners.

4.

All fasteners shall be resistant to oxidation or other corrosive action completely through their cross sections.

5.

Work shall be secured with fasteners of the same metal, color and finish as the component they secure where hey are exposed to view.

6.

E.

F.

Fasteners shall be utilized in strict accordance with their manufacturer’s specifications, directions, recommendations and as indicated on Design Intent Drawings.

Neon/Lamp: All exposed neon shall be installed in such a manner as to minimize double backs, exposed wires, etc. All exposed neon shall appear as a continuous line (4’ - 0” min. seamless runs) of light with no irregularities from section to section. Contractor shall coordinate with McGINTY to select exact color of neon and/or lamps. Contractor is responsible for referencing and following code constraints.

TEL 303 402 9233 FAX 303 402 9234

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE

Bid Drawings

Aluminum Sheet: Not less than 0.125” thick unless noted otherwise. Fabricate by the HELIARC or MIG welding process with all visible seams continuous welded, filled and ground smooth, unless the seam occurs along a color break. Then a clean butt joint with concealed backing channel and plug weld is finished to match surrounding finish. All blinds, curves, and folds to be geometrically correct and produced by a consistent mechanical methods unless approved otherwise by McGINTY.

REVISIONS

G.

Jointing and Brake Forming: All sheet material shall have brake formed edges with radii not greater than sheet thickness unless otherwise specified. Adjacent stock shall have edges of similar radii.

SIGN TYPE

H.

Welding: All exposed welds are to be ground smooth and filled to match surface of adjacent material.

VIII. FABRICATION

#

DATE

NOTES

1

10.14.11

Draft Bid Set

2 3

QUANTITY

DESCRIPTION

A.

Copy Application: Provide copy to comply with the requirements indicated for size, style, spacing, content, position, material, finish and color of letter, numbers, symbols and other graphic device.

Performance Specification General Conditions P

03


PERFORMANCE REQUIREMENTS / GENERAL CONDITIONS IX. INSTALLATION A.

B.

C.

D.

E.

F.

G.

H.

X.

B.

Contractor shall be responsible for determining the erection and dismantling of all barricade or protective coverings necessary to safeguard the public and property during the performance and duration of his or her work.

1.

Contractor shall attach objects to substrates in accordance with the project structural engineer’s and the manufacturer’s instructions unless otherwise shown. Install level, plumb, and at the proper height. Repair or replace damaged units as directed by the Owner or McGINTY. Visible abrasions to finished surfaces must be repaired so that damages is noted visible.

The Contractor will be responsible for any damage caused to building, site, and adjacent objects or elements during installation. The Contractor shall be responsible for cleaning up all work areas upon the completion of their work, on a daily basis.

Contractor shall be responsible for matching electrical service available on site to the requirements of the object, including transformers. All necessary electrical components as well as the entire assembly are to be UL listed, or by approved nationally recognized testing lab. Contractor is responsible for compliance with all applicable environmental regulations.

I.

Contractor is responsible for compliance with all OSHA regulations.

J.

Contractor shall be responsible for coordination of all elements with General Contractor, other sub-Contractors and trades people relative to this work. The coordination efforts will include, but not limited to: deliveries, work schedules, and installation. Storage space at the job site is limited and will also require coordination and/or approval. Materials or finished work stored a the job site without prior permission may be relocated at Contractor’s expense.

C.

D.

E.

F.

CLEANING, PROTECTION AND WARRANTIES A.

All items to be installed by the Contractor shall be left in a clean and as-new condition. Upon completion of the installation, clean all soiled surfaces and touch up all finishes in accordance with the manufacturer’s instructions. All debris and packaging material shall be removed and disposed of in a legal manner. The protective masking of the plastic surface shall be removed by the Contractor upon completion or installation. All excavation and site work shall be returned to its original grade configuration after contract items are installed.

No delamination or any portion of the object including vinyl graphics or copy.

B.

Contractor shall secure and pay for all insurance required by law including: Liability, Worker’s Compensation, Comprehensive, Construction Liability, Personal Injury, Comprehensive Auto and Property on- and off-site.

C.

Contractor shall not reveal or disseminate any information to any person(s), private or public, other than McGINTY, Owner or Contractor’s personnel necessary to execute the contract without first contacting the Owner for permission.

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Installation of all items shall be by the Contractor. Installation includes provisions of any required footings, all anchor bolts, fastenings, attachment metals, and other miscellaneous metal items embedded in concrete or building wall material as required, and security of unites in place with no visible fasteners.

The Contractor shall provide required electrical equipment and connection to shell building. The point of connection is to be provided by General Contractor. All electrical connections shall be made by a licensed electrician employed by the Contractor for this purpose. All connections shall be made in accordance with the requirements of the National Electrical Code (N.E.C.) in addition to all applicable local codes. Electrical Contractors shall provide and install all wiring, conduit, junction boxes and electrical devices necessary to provide electrical power to rough-in connections unless otherwise noted. Contractor shall provide concealed neon transformers and all electrical connections beyond rough-in connections by electrical Contractor, according to N.E.C. approved methods.

Finish Surfaces: All units shall be warranteed in writing by the Contractor for a period of no less than one (1) year from the date of Owner acceptance. All finishes (except large format computer output) are to be warranteed for three (3) years from the date of Owner acceptance. There shall be:

G.

No cupping, warping or dishing.

3.

No bubbling, crazing, chalking, rusting or other disintegration of surfaces, messages or edge finishes.

All high resolution large format computer output indicated in the Design Intent Document must comply with the following:

4.

No corrosion developing beneath the paint surface of the support system, except as the result of obvious vandalism.

1. Minimum resolution: 400 dpi, or as approved by McGINTY.

5.

No corrosion of fasteners.

6.

No movement of objects from their foundations. The objects must remain true and plumb on their foundations, except when obvious post-installation external damage has occurred.

7.

No fading of the colors when matched against a sample of the original color and material.

8.

No variation of any other performance stated by McGINTY on the drawings or in the Fabricator Performance and Material Requirements.

Structural/Components: Contractor shall provide Owner with three (3) copies of the written warrant prior to installation guaranteeing to correct, to Owner’s satisfaction, at Contractor’s sole expense, all defects in fabrication and installation of work for a period of one (1) year after the Owner’s acceptance of completed installation. External Lamps: All lamps shall be warranteed against failure for ninety (90) days, all neon for three (3) years, and all ballasts for one (1) year. Lamps are to be replaced within forty-eight (48) hours of notice by Owner and/or General Contractor. In the event of failure within specified times these items are to be replaced by Contractor at Contractor’s sole expense. Lamp Service: The Contractor shall provide Owner with three (3) copies and complete lamp replacement information, brand, type, wattage, color, etc., for all lighted components. This information shall be in a typewritten format (8-1/2” x 11”) and shall indicated at least one (1) local (site) supplier. Lamps must comply with all local, state, and federal regulations. Maintenance: The Contractor shall provide to Owner three (3) copies each of complete finish/component care instructions as specified by the manufacturer for on-going cosmetic cleaning and maintenance. These are to be submitted in an 8-1/2” x 11” 3-ring binder. Contractor to ensure signage, LED, neon, lamps, and electrical components etc. are easily accessible for maintenance. The Contractor shall have total and complete responsibility for the security of all equipment, materials and sign components until reviewed and accepted by Owner.

XI. PERMITS A.

XII. LARGE FORMAT COMPUTER OUTPUT

2.

Securing and paying for all permits required by governmental agencies is the responsibility of the Contractor. Inspection and tests necessary for the construction and placement of all work required by the applicable governing agencies is by the Contractor.

2. Process: 3M SCOTCHPRINT (or approved equal). 3. Substrate: Opaque or Translucent Scotchcal film (or approved equal) or fabric as specified. 4. Finish: 2 mil Matte overlaminate. 5. Input: Electronic art as specified. 6. Warranty: Product must be warranteed against color fading, UV damage, delamination, shrinkage or peeling for a minimum of five (5) years from date of installation. 7. Wall preparation (by General Contractor): Smooth drywall with eggshell finish acceptable. Prepare wall with two (2) coats of exterior grade, semi-gloss latex. Five (5) days dry time prior to application.. XIII. THE AMERICAN WITH DISABILITIES ACT REQUIREMENTS All signs must comply with ADA Guidelines and/or code requirements. A. Provide copy proofed braille to ADA guidelines for permanent room signs requiring Grade Two Braille. Required type and symbols must be raised a minimum of 1/32”.

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

B. Main type on permanent room signs must be raised a minimum of 1/32”.

DATE

C. Signs identifying permanent rooms or spaces must be mounted 60” from finish floor center of sign on the wall surface adjacent to the latch side of the door.

DRAWN BY / JE

D. Characters and backgrounds on ADA signage shall be eggshell, matte, or other non-glare finish. XIV. BID NOTES Original fabrication quotes shall be sent directly to the Owner with copies of all pricing information to be sent simultaneously to McGINTY and, if specified, to the General Contractor.

10.14.11

Bid Drawings REVISIONS #

DATE

NOTES

1

10.14.11

Draft Bid Set

2 3

Pricing shall be submitted in accordance with the bid documents. Bidders are required to clearly indicate in writing within their bid the method of construction anticipated, the materials to be used, and any exclusions or exceptions to the bid documents. Items not bid shall be marked “Not Bid”.

SIGN TYPE

QUANTITY

DESCRIPTION

Performance Specification & General Conditions P

04


BID SHEET: Signs

The Contractor is responsible for verifying the number of units required for each sign type and supplying either; 1) the unit quantity identified for each sign, or 2) quantity located on the installation drawings-which ever is HIGHER. 3) Indicate “not bid” on any items to be omitted from your bid.

Description

Sign Type

Quantity

Exterior ID Sign

XA

1

Exterior Dock ID

XB

2

Unit Cost

Extended Cost

Comments

4860 STERLING DRIVE BOULDER, CO 80301

Store ID

A

4

Hours Sign

B

4

Illuminated Café Stanchion

C

4

Department Sign

D

15

Blade Sign

E

33

Elevator ID

F

2

Directory Stanchion

G

2

Promotional Graphic

H

4

Small Canvas Graphic (20"x30")

I

29

Medium Canvas Graphic (28"x42")

J

15

Large Canvas Graphic (32"x48")

K

5

Mural Graphic (#001)

L

1

Mural Graphic (#007)

N

1

TEL 303 402 9233 FAX 303 402 9234

STANDARD SIGN HOLDER PROVIDED BY BARNES & NOBLE

CUSTOM GRAPHICS PROVIDED BY BUYENLARGE CUSTOM GRAPHICS PROVIDED BY BUYENLARGE CUSTOM GRAPHICS PROVIDED BY BUYENLARGE

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS

Mural Graphic (#036)

O

1

Mural Graphic (#105)

P

1

Café Mural Graphic (#111)

R

1

Mural Graphic or Dimensional Display (#129)

S

1

Mural Graphic (#144)

T

1

DRAWN BY / JE

Stair Mural Graphic (#147)

U

1

Bid Drawings

Mural Graphic (#174)

W

1

REVISIONS

Mural Graphic (#180)

X

1

PROJECT

#BNCO9013

DATE

10.14.11

#

DATE

NOTES

1

Mural Graphic (#106)

Y

1

Mural Graphic (#014, #017, #018, #020, #023)

Z

5

Mural Graphic (#188)

AA

1

Illuminated Department Sign

BB

1

Adidas Store Banner Sign

CC

2

Adidas Store Header Sign

CC

1

* Estimates to include taxes and delivery. Installation for murals only. Other signs to be installed by FFE/GC.

2 3

SIGN TYPE

DESCRIPTION

Bid Sheet Grand Total: Bidder Name:

Contact #:

P

05

QUANTITY


052 002

001

005

003

006

007

008

009

053 012

010

013

011

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

014 P

015 016 017

L

018 019 020

K

050

Texas A&M University

J

023 MH.8

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

H

DATE

024

049

025

DRAWN BY / JE

Bid Drawings

F

048

10.14.11

REVISIONS #

047

DATE

NOTES

1 2

D

3

026

SIGN TYPE

QUANTITY

046

045

044

043

042

041

040

039

038

037

036

035

034

033

032

029

M3

030

M4

5

7

13

14

16

19

23

26

30

36

39

027 028

031

Memorabilia - Murals, Prints and Blade Signs

DESCRIPTION

Sign Location Plan Basement Level

Signs - Wayfinding and Department P

06


109 101

102

103

104

105

106

107

108

111

113

110

115 114

117 116

119-122 118

126

123

125

127

124

128

130 129

132 131

134 133

135

189 136

138

137 184 183

139

182

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

140

181

141

180

142

179

143

178 177

145

176

146

175

147

185 174

148

Texas A&M University 149

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE

Bid Drawings REVISIONS

172

#

DATE

NOTES

1 2 3

171

157

156 191 170

169

168

167

188

166

165

164

163

162

161

187

160

159

154

155

SIGN TYPE

158

153 186

190

Memorabilia - Murals, Prints and Blade Signs

QUANTITY

150 DESCRIPTION

Sign Location Plan Level 1

Signs - Wayfinding and Department P

07


Sign #

Sign Type

Sign Description

Message Side A

Message Side B

001

L

Mural Graphic

(see drawing)

002

F

Elevator ID

Elevator (glyph)

003

K

Large Canvas Graphic

(see drawing)

004

OMIT

005

D

Department Sign

ONLINE ORDERS PICKUP

006

K

Large Canvas Graphic

(see drawing)

007

N

Mural Graphic

(see drawing)

008

OMIT

009

D

Department Sign

SCHOOL & ART SUPPLIES

SCHOOL & ART SUPPLIES

010

A

Store ID

011

C

Café Stanchion

012

E

Blade Sign

013

E

Blade Sign

014

Z

Mural Graphic

015

D

Department Sign

CUSTOMER SERVICES

CUSTOMER SERVICES

016

K

Large Canvas Graphic

(see drawing)

017

Z

Mural Graphic

018

Z

Mural Graphic

019

K

Large Canvas Graphic

020

Z

Mural Graphic

021

OMIT

022

D

Comments

Elevator (glyph) (48"x32") 4860 STERLING DRIVE BOULDER, CO 80301

ONLINE ORDERS PICKUP

TEL 303 402 9233 FAX 303 402 9234

(48"x32")

(32"x48")

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

(see drawing)

(32"x48")

DATE

10.14.11

DRAWN BY / JE

Bid Drawings

Department Sign

REVISIONS #

023

Z

Mural Graphic

024

I

Small Canvas Graphic

(see drawing)

(30"x20")

025

I

Small Canvas Graphic

(see drawing)

(30"x20")

026

K

Large Canvas Graphic

(see drawing)

(32"x48")

027

G

Directory Stanchion

028

E

Blade Sign

029

I

Small Canvas Graphic

(see drawing)

(30"x20")

030

I

Small Canvas Graphic

(see drawing)

(30"x20")

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

Standard B&N Stanchion. Sign frame provided by B&N DESCRIPTION

Message Schedule

P

08


Sign #

Sign Type

Sign Description

Message Side A

Message Side B

Comments

031

D

Department Sign

TEXTBOOKS

TEXTBOOKS

032

I

Small Canvas Graphic

(see drawing)

(30"x20")

033

I

Small Canvas Graphic

(see drawing)

(30"x20")

034

I

Small Canvas Graphic

(see drawing)

(30"x20")

035

I

Small Canvas Graphic

(see drawing)

(30"x20")

036

I

Mural

(see drawing)

(30"x20")

037

I

Small Canvas Graphic

(see drawing)

(30"x20")

038

D

Department Sign

TEXTBOOKS

TEXTBOOKS

039

D

Department Sign

CUSTOMER SERVICES

CUSTOMER SERVICES

040

I

Small Canvas Graphic

(see drawing)

(30"x20")

041

I

Small Canvas Graphic

(see drawing)

(30"x20")

042

I

Small Canvas Graphic

(see drawing)

(30"x20")

043

I

Small Canvas Graphic

(see drawing)

(30"x20")

044

I

Small Canvas Graphic

(see drawing)

(30"x20")

045

I

Small Canvas Graphic

(see drawing)

(30"x20")

046

I

Small Canvas Graphic

(see drawing)

(30"x20")

047

I

Small Canvas Graphic

(see drawing)

(30"x20")

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

048

I

Small Canvas Graphic

(see drawing)

(30"x20")

049

I

Small Canvas Graphic

(see drawing)

(30"x20")

050

XB

Dock ID

DRAWN BY / JE

051

XB

Dock ID

Bid Drawings

052

B

Hours Sign

REVISIONS

DATE

10.14.11

#

053

A

Store ID

DATE

NOTES

1 2 3

101

H

Promotional Graphic

102

E

Blade Sign

103

E

Blade Sign

104

C

Café Stanchion

105

P

Mural

SIGN TYPE

QUANTITY

DESCRIPTION

Message Schedule

P

09


Sign #

Sign Type

Sign Description

Message Side A

106

J

Medium Canvas Graphic

(see drawing)

107

E

Blade Sign

108

F

Elevator ID

109

E

Blade Sign

Elevator

Message Side B

Comments (42"x28")

Elevator 4860 STERLING DRIVE BOULDER, CO 80301

110

E

Blade Sign

111

R

Café Mural

112

OMITTED

113

OMITTED

114

E

Blade Sign

115

J

Medium Canvas Graphic

116

E

Blade Sign

117

J

Medium Canvas Graphic

118

E

Blade Sign

119

J

120

TEL 303 402 9233 FAX 303 402 9234

(see drawing)

(42"x28")

(see drawing)

(42"x28")

Medium Canvas Graphic

(see drawing)

(28"x42")

J

Medium Canvas Graphic

(see drawing)

(28"x42")

121

J

Medium Canvas Graphic

(see drawing)

(28"x42")

122

J

Medium Canvas Graphic

(see drawing)

(28"x42")

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

123

H

Promotional Graphic

124

D

Deparment Sign

125

A

Store ID

DRAWN BY / JE

126

B

Hours Sign

Bid Drawings

127

E

Blade Sign

DATE

CHECKOUT

10.14.11

REVISIONS #

128

E

Blade Sign

129

S

Mural or dimensional display

130

E

Blade Sign

131

E

Blade Sign

132

E

Blade Sign

133

I

Small Canvas Graphic

(see drawing)

(30"x20")

134

I

Small Canvas Graphic

(see drawing)

(30"x20")

135

I

Small Canvas Graphic

(see drawing)

(30"x20")

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

DESCRIPTION

Message Schedule

P

10


Sign #

Sign Type

Sign Description

Message Side A

Message Side B

Comments

136

I

Small Canvas Graphic

(see drawing)

(30"x20")

137

I

Small Canvas Graphic

(see drawing)

(30"x20")

138

I

Small Canvas Graphic

(see drawing)

(30"x20")

139

D

Department Sign

140

I

Small Canvas Graphic

(see drawing)

(30"x20")

141

I

Small Canvas Graphic

(see drawing)

(30"x20")

142

E

Blade Sign

143

E

Blade Sign

144

OMITTED

145

G

Directory Stanchion

146

E

Blade Sign

147

U

Stair Mural

148

J

Medium Canvas Graphic

(see drawing)

(42"x28")

149

J

Medium Canvas Graphic

(see drawing)

(42"x28")

150

E

Blade Sign

151

OMITTED

152

OMITTED

153

E

Blade Sign

154

E

Blade Sign

155

E

Blade Sign

DRAWN BY / JE

156

E

Blade Sign

Bid Drawings

157

C

Café Stanchion

REVISIONS

158

B

Hours Sign

159

XA

Exterior ID Sign

160

E

Blade Sign

161

E

Blade Sign

162

E

Blade Sign

163

D

Department Sign

CHECKOUT

164

J

Medium Canvas Graphic

(see drawing)

(28"x42")

165

J

Medium Canvas Graphic

(see drawing)

(42"x28")

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Standard B&N Stanchion. Sign frame provided by B&N

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

#

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

DESCRIPTION

Message Schedule

P

11


Sign #

Sign Type

Sign Description

Message Side A

Message Side B

Comments

166

J

Medium Canvas Graphic

(see drawing)

(42"x28")

167

E

Blade Sign

168

E

Blade Sign

169

J

Medium Canvas Graphic

(see drawing)

(42"x28")

170

J

Medium Canvas Graphic

(see drawing)

(42"x28")

171

J

Medium Canvas Graphic

(see drawing)

(42"x28")

172

J

Medium Canvas Graphic

(see drawing)

(42"x28")

173

OMITTED

174

W

Dimensional letter display

[LOGO] TEXAS A&M UNIVERSITY [LOGO]

175

D

Department Sign

AGGIE STOP

AGGIE STOP

176

D

Department Sign

CUSTOMER SERVICES

CUSTOMER SERVICES

177

B

Hours Sign

178

E

Blade Sign

179

E

Blade Sign

180

X

Mural

181

E

Blade Sign

182

A

Store ID

183

C

Café Stanchion

185

BB

Illuminated Department Sign

186

H

Promotional Graphic

DRAWN BY / JE

187

H

Promotional Graphic

Bid Drawings

188

AA

Small Dimensional Letters

189

CC

Adidas Store Banner Sign

190

DD

Adidas Store Header Sign

191

CC

Adidas Store Banner Sign

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

AGGIE STOP

AGGIES

AGGIE STOP

DATE

10.14.11

REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

DESCRIPTION

Message Schedule

P

12


15'-8"

1'-108"

1/2"

1/2"

X 14

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

8 9/16" 1"

1

Elevation Detail: Main Exterior Sign Scale: 3/4"=1'-0"

19

16

14

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

1 13

2 14

10.14.11

DRAWN BY / JE, PY

16'-9" (VIF)

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

9'-0"

1'-4 1/2"

1"

2'-0"

11'-3 3/4"

SIGN TYPE

QUANTITY

XA DESCRIPTION

Exterior ID Sign

1

Elevation: Main Exterior Sign Scale: 3/16"=1'-0"

P

13

1


2 1/2" deep dimensional letter, non-illuminated. Letters mechanically fasten to mounting bracket with concealed fastener 1/4" metal letter. Painted Matthews Brushed Aluminum. Mount to face of dimensional letter. 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

REQUIRE SECTION OF COLUMN Metal letter mounting bracket. Painted Dark Metallic Grey (TBD). Fasten to top of sign cabinet.

3

Side View Scale: 1 1/2"=1'-0"

See sheet 13 for mounting location

2

2 1/2" deep dimensional letter. Letters are NOT illuminated. Letters mounted to back panels with concealed fasteners. Color: Dark metallic gray (T.B.D.)

Attachment Detail Scale: 1 1/2"=1'-0"

2 1/2" square support tube anchored to ceiling. Color: Matthews Brushed Aluminum

Adjacent column. Opp. Hand Sim.

Letter mounting bracket. Color: Dark metallic gray (T.B.D.) 1" x 1/2" top and bottom cap. Color: match "Aggie Maroon" school color (T.B.D.)

9'-0"

1/4" painted aluminum dimensional letter mounted flush to sign cabinet. Color: Matthews Brushed Aluminum 6" deep painted aluminum sign cabinet. Cabinet is NOT illuminated. Color: match "Aggie Maroon" school color (T.B.D.)

2

Scale: 1/4"=1'-0"

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

Support tubes anchor to vertical concrete column.

Section: Main Exterior Sign

Texas A&M University

3

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

1

4.21.11

2 3

SIGN TYPE

QUANTITY

XA DESCRIPTION

Exterior ID Sign

Side View Scale: 1 1/2"=1'-0"

NOTES

P

14

1


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Texas A&M University

1 16

14 16

EXTERIOR / INTERIOR SIGNS & GRAPHICS

17

19

20

23

24

PROJECT

#BNCO9013

DATE

10.14.11

AT TEXAS A M UNIVERSITY

OPEN TO STAIRS

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

FIXED PANEL

9'-0"

FIXED PANEL

STORE HOURS

MOND MON DAY– THURSDAY, 8AM– 6PM FRID FRI D AY, 8AM– 5PM www.tamu.bncollege.com

X

DATE

NOTES

1 2

X

3

SIGN TYPE

QUANTITY

A1

1

DESCRIPTION

1

Elevation: Store ID - Main Concourse Entry (#125) Scale: 1/4"=1'-0"

NOTE: FINAL STORE IDENTITY TO BE DETERMINED (SEE PAGE 13 FOR OPTIONS)

#125 Store ID Main Concourse Entrance P

15


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

REQUIRE SECTION OF ENTRY

1

Elevation Detail: Typical Entry Sign Scale: 3/4"=1'-0"

Texas A&M University

Internally illuminated dimensional letters

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

10'-0"

White acrylic push-through letters Internally illuminated sign box

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1'-11 1/4"

1'-1"

1 2 3

AT TEXAS A M UNIVERSITY

SIGN TYPE

QUANTITY

A1

1

DESCRIPTION

1

Elevation Detail: Main Concourse Entry Scale: 3/4"=1'-0"

Store ID Main Concourse & Café Marketplace Entries P

16


1 18

L

K

4'-0"

EQ

J

3'-0"

AT TEXAS A M UNIVERSITY

9'-0"

FIXED PANEL

FIXED PANEL

www.tamu.bncollege.com

4860 STERLING DRIVE BOULDER, CO 80301

TM X

3

AT

STORE HOURS

MONDAY–THURSDAY, 8AM–6PM FRIDAY, 8AM–5PM

TEL 303 402 9233 FAX 303 402 9234

X

Elevation: Café Marketplace Entry Scale: 1/4"=1'-0"

7

EQ

1 18

4'-0"

EQ

10

EQ

AT TEXAS A M UNIVERSITY X

FIXED PANEL

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

2 M4.2

1 18

DATE

Elevation: Lower Level Concourse Entry (continued)

10.14.11

Scale: 1/4"=1'-0"

DRAWN BY / JE, PY

4'-0"

EQ

M4.8

5

6

7

3'-7 1/2"

Bid Drawings REVISIONS #

DATE

NOTES

1

AT TEXAS A M UNIVERSITY

2

TM

9'-0"

3

FIXED PANEL

X

X

FIXED PANEL SIGN TYPE

A2 DESCRIPTION

1

Elevation: Lower Level Concourse Entry

Store ID Lower Level Concourse & Café Marketplace Entrance

Scale: 1/4"=1'-0"

P

17


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

REQUIRE SECTION OF INTERIOR CEILING & WINDOW ARCADE

1

Elevation Detail: Typical Entry Sign Scale: 3/4"=1'-0"

Internally illuminated dimensional letters

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

10'-0"

White acrylic push-through letters

DATE

10.14.11

DRAWN BY / JE, PY

Internally illuminated sign box

Bid Drawings REVISIONS #

DATE

NOTES

1'-11 1/4"

1'-1"

1 2 3

AT TEXAS A M UNIVERSITY

SIGN TYPE

QUANTITY

A2

3

DESCRIPTION

Store ID

1

Elevation Detail: Typical Entry Sign Scale: 3/4"=1'-0"

P

18


5'-10 3/8"

“Bevel” created by masking and sandblasting 4860 STERLING DRIVE BOULDER, CO 80301

Satin Brushed Natural Aluminum #6257 applied to 1/4” acrylic with returns painted black.

4'-10"

TEL 303 402 9233 FAX 303 402 9234

2

Elevation Detail: Main Concourse Entry Mural

3

Scale: NTS Provide plywood blocking to accept A&M Logo Display

26'-2"

Detail: A&M Logo Display Scale: 3/4” = 1’-0” Scotchprint graphic applied to finished wall.

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

8'-8 5/8"

12th Man The tradition of the Twelfth Man was born on the second of January 1922, when an underdog Aggie team was playing Centre College, the nation's top ranked team at the time. As the hard fought game wore on, the Aggies were forced to dig deep into their limited reserves because of injuries. Coach Dana X. Bible remembered that a former squad member, who was playing basketball at the time, was in the press box helping reporters identify players. His name was E. King Gill. Gill was called from the stands, suited up, and stood ready throughout the rest of the game… which A&M finally won 22-14. When the game ended, E. King Gill was the only man left standing on the sidelines for the Aggies. Gill later said, "I wish I could say that I went in and ran for the winning touchdown, but I didn't. I simply got ready and waited--just in case I was needed."This gesture was more than enough for the Aggie Team. Although Gill did not play in the game, he had accepted the call to help his team. He came to be known as the “Twelfth Man” because he stood ready for in case the eleven men on the gridiron needed him. That spirit of readiness for service, desire to support, and enthusiasm helped kindle a flame of devotion among the entire student body; a spirit that has grown vigorously throughout the years. The entire student body at A&M is the Twelfth Man, and they stand during the entire game to show their support. The 12th Man is always in the stands waiting to be called upon if needed.This tradition took on a new look in the 1980's when Coach Jackie Sherrill started the 12th Man Kick-Off Team, composed of regular students through open tryouts. This 12th Man team performed very well and held opponents to one of the lowest yards per return averages in the league. Later, Head Coach R.C. Slocum changed the team to allow only one representative of the 12th Man on the kick-off team. The 12th Man tradition exists also in musical form; the student body sings “The Twelfth Man” after each game in which the Aggies are outscored. Midnight Yell Yell Practice began as a post dinner activity in early 1900’s, when different corps companies would gather together to "learn heartily the old time pep." However, it was not until 1931, that Midnight Yell Practice, as it is known today, was held before the t.u. game. It began, when a group of cadets were gathered in Peanut Owen's dorm room in Puryear Hall. Someone suggested that all of the freshmen should fall out and meet on the steps of the YMCA building at midnight. The cadets notified senior yell leaders Horsefly Berryhill and Two Gun Parker of their intents. Although it could not officially be authorized, they said they may just show up. Needless to say, the word spread quickly, and when the freshmen began to arrive, there were railroad flares and torpedoes stuck in flower pots around the YMCA building to light the area. The first Midnight Yell had begun!!! Today, Midnight Yell is held the night before a home game in Kyle Field and at the Arches on Thursday nights before away games. Also for an away game, a site is designated for a Midnight Yell in the city of our opponent the night before the game. For example, for the t.u. game, it is held at the Texas Capitol in Austin. For a yell at Kyle Field, yell leaders lead the Fightin' Texas Aggie Band and the Twelfth Man into the stadium. The yell leaders lead the crowd in old army yells, the school’s songs, and tell fables of how the Aggies are going to beat the everlivin' hell out of our opponent. Finally, the lights go out, and Aggies kiss their dates. If they don't have a date, all they have to do is “flick their Bic.” As the story goes, the flames make it easier for two dateless people to find a kiss!The purpose of Midnight Yell is to pump up the Twelfth Man for the next day's big game!Gig 'em Pinky Downs, class of 1906 and a member of the Board of Regents from 1923 to 1933, is credited with the Gig ‘Em hand sign. At the 1930 Yell Practice before the TCU football game, Downs shouted out, "What are we going to do to those Horned Frogs?" Answering his own question, he replied, “Gig ‘Em, Aggies!” while making a fist with his thumb extended. A “gig” is a spear-like tool used for hunting frogs. The gesture became known as the first hand sign of The Southwest Conference. Howdy "Howdy" is the official greeting of Texas A&M University. It is our way of ensuring that no one feels like a stranger. The exact origin on this tradition is not known. However, "Howdy" is what sets us apart as the friendliest campus in the world. Bonfire The first Aggie Bonfire began in the early 1900's as a pile of wood and trash next to the train station. The cadets decided to make a Bonfire to congratulate the football team on their win. Although this first Bonfire was held in the early morning hours of November 18, 1907, the first on-campus Aggie Bonfire was not held until 1909. Bonfire grew immensely through the years. The largest Bonfire was in 1969 and stood 109ft., which is only one foot shorter than Rudder tower. After that, the administration decided to regulate the Bonfire height to 55ft. There have been two years that Bonfire did not burn. First, in 1963, following the death of President John F. Kennedy, the senior class made one of the most difficult decision of their time at Texas A&M. In honor of their president, they decided to dismantle the Bonfire, which had recently been completed. The head yell leader at the time, Mike Marlowe, was quoted as saying, "It is the most we have and the least we can give." The second time that Bonfire was built and did not burn was in 1999. On November 18th, Bonfire fell, taking 12 of our fellow Aggies with it. This day was one of the most trying days for Aggies everywhere. At this time, Bonfire has been postponed indefinitely and no one knows if Bonfire will return. The Aggie Spirit has created the Aggie Traditions and that Aggie Spirit will thrive through the trying times. Reveille Reveille, the first lady of Aggieland, is the official mascot of Texas A&M University. She is the highest ranking member of the Corps of Cadets, and she is a Five-Star General. Reveille I came to Texas A&M in January 1931. A group of cadets hit a small black and white dog on their way back from Navasota. They picked up the dog and brought her back to school so they could care for her. The next morning, when "Reveille" was blown by a bugler, she started barking. She was named after this morning wakeup call. The following football season she was named the official mascot when she led the band onto the field during their half-time performance. When Reveille I died on January 18, 1944, she was given a formal military funeral on the gridiron of Kyle Field. She was then buried at the north entrance to the field, as all Reveilles are, facing the scoreboard so that she can always watch the Aggies outscore their opponent. Before naming Reveille II, there were several other unofficial mascot, such as Tripod, Spot, and Ranger. It was not until a later Reveille that she was a full-blood Collie. The most current Reveille is Reveille VIII, and she was officially introduced on August 30, 2008. Reveille is the most revered dog on campus. Company E-2 has the privilege of taking care of Reveille. If she is sleeping on a cadet's bed, that cadet must sleep on the floor. Cadets address Reveille as "Miss Rev, m'am." If she is in class and barks while the professor is teaching, the class is to be immediately dismissed. Reveille is a highly cherished mascot and receives only the best. Silver TapsBy far, one of Texas A&M's most honored traditions is Silver Taps. Silver Taps is held for a graduate or undergraduate student who passes away while enrolled at A&M. This final tribute is held the first Tuesday of the month following the students’ passing. The first Silver Taps was held in 1898 and honored Lawrence Sullivan Ross, the former governor of Texas and president of A&M College. Silver Taps is currently held in Academic Plaza. On the day of Silver Taps, a small card with the deceased students name, class, major, and date of birth is placed at the base of the Academic Plaza flagpole, and the Silver Taps Memorial located behind the flagpole. Around 10:15 that night, the lights are extinguished and hymns chime from Albritton Tower. Students silently gather at the statue of Lawrence Sullivan Ross. At 10:30pm, the Ross Volunteer Firing Squad marches into the plaza and fires a twenty-one gun salute. Buglers then play a special rendition of Silver Taps, by Colonel Richard Dunn, three times from the dome of the Academic Building: once to the north, south, and west. It is not played to the east because it is said that the sun will never rise on that Aggies life again. After the buglers play, the students leave from Academic Plaza in complete silence. Silver Taps is a sacred tradition that Aggies treasure dearly. Replant It is one of the largest student-run, enviromental service projects in the nation. It was orginally developed by Scott Hantman to replenish some of the trees cut for the Bonfire. In the Spring of 1991, he joined Bonfire leaders and planted 400 trees. In 1994, it became a SGA committee that works year-round coordinating the event. They are sponsored by Texas A&M, the National Tree Trust, and the Army Corps of Engineers at Lake Somerville.Thousands of trees are planted each year by hundreds of student volunteers from A&M and the Bryan/College Station area. Trees are planted at local parks, schools, and other public land properties. All trees are donated by the National Tree Trust (between 500-10,000 per year). Corps Texas A&M was established as a military institution, and the Corps of Cadets has played an important part in its history and development. Although membership in the Corps became voluntary in 1965, Texas A&M historically has produced more military officers than any other institution in the nation, except for the service academies. More than 200 of its graduates have become generals or admirals. More Aggies were commissioned and fought in World War II than men from West Point or Annapolis.The Corps of Cadets at Texas A&M is not just another ROTC unit that might be found at most campuses. The 2,200 men and women of the Corps form the largest uniformed body of students outside the U.S. military academies. Although cadets can earn commissions as military officers, membership in the Corps itself carries no military obligation. In fact, only about 30 percent of graduating cadets are commissioned, while the rest pursue civilian careers. The Corps has more to offer than just military training. It is a tightly-knit group of students that offers camaraderie, as well as leadership training that is useful in all post-college careers.Texas A&M has rich military history. More than 200 of its graduates have become generals or admirals. More Aggies were commissioned and fought in World War II than men from West Point or Annapolis. Aggie Ring One of the greatest moments in the life of every Aggie is the day that he or she receives an Aggie Ring. This tradition began with the Class of 1889. The original rings were very different from the one worn today because, at that time, several companies made different versions of the Aggie Ring. E. C. Jonas, Class of 1894, designed a ring that is similar to the ring worn today. There have been only slight changes to this design, with one exception; in 1964, the Legislature of the State of Texas changed the university's name from the Agricultural and Mechanical College of Texas to Texas A&M University, and the name on the ring was changed accordingly.The Aggie Ring is one of the most symbolic of our traditions. Everything seen on the ring represents a value that an Aggie should hold. On the top is a large shield, which symbolizes the desire to protect the reputation of the university. The 13 stripes on the shield represent the 13 original states of America. The five stars on the shield refer to the phases of development of any Aggie: mind or intellect; body; spiritual attainment; emotional poise; and integrity of character.The eagle symbolizes agility and power, and the ability to reach great heights. The large star on the side of the ring symbolizes the Seal of Texas. The five-pointed star is encircled with a wreath of olive and laurel leaves symbolizing achievement and a desire for peace. The live oak leaves symbolize the strength to fight for our country and our state. The leaves are joined at the bottom by an encircling ribbon to show the necessity of uniting these two traits to accomplish one's ambition to serve. An ancient cannon, a saber, and a rifle are on the other side of the ring and symbolize how citizens of Texas fought for their land and are determined to defend it. The saber stands for valor and confidence, while the rifle and cannon stand for a preparedness and defense. The crossed flags of the United States and Texas recognize an Aggie's dual allegiance to both nation and state. Traditionally, students wear their ring with the class year facing them to signify the fact that their time at A&M is not yet complete. During Senior Week at the annual Ring Dance, the student's ring is turned around to face the world proudly, just as the Aggie graduate will be ready to face the world. Muster Aggies gathered together on June 26, 1883 to live over again their college days, the victories and defeats won and lost upon the drill field and classroom. Eventually the annual gathering evolved into a celebration of Texas Independence on San Jacinto Day – April 21st. Over time the tradition has changed, but its very essence has remained “If there is an A&M man in one hundred miles of you, you are expected to get together, eat a little, and live over the days you spent at the A&M College of Texas.” Muster is celebrated in more than four hundred places worldwide, with the largest ceremony on the Texas A&M campus in College Station. Aggie Muster as we know it today is credited to E. E. McQuillen ’20, who served as the Executive Secretary of The Association of Former Students. It is fitting that he was honored to serve as the first Campus Muster speaker. This year we are privileged to have Mrs. Brooke Leslie Rollins ’94 to serve as the 2007 Campus Muster speaker. The committee was recognized as a student organization in 1950. Like the tradition itself, the committee has transcended the eras and events throughout its history and remained true to the timeless ideals of Muster. The Muster Committee is responsible for organizing and planning every aspect of the tradition, from speaker to barbeque, awareness to the Roll Call – this committee continues the livelihood of this great tradition year after year. The committee falls under the discretion of the Student Government Association. The 2007 Muster Committee is composed of 22 committee members, seven sub-chairs, and one chair. Their tasks vary among the five subcommittees: Awareness, Programs, Roll Call and Families, Speaker Selection, and Special Operations.Muster is a time to look to the past, present, and future…not only to grieve but to reflect and to celebrate the lives that connect us to one another. A gesture so simple in nature yet so lasting in spirit, Muster is the lasting impression every Aggie leaves with us; it reminds us of the greatness that lies within these walls, of the loyalty we possess, of the connection that binds us, and of the idea that every Aggie has a place of importance – whether they are present in flesh or spirit.Big Event The Big Event is the largest, one-day, student-run service project in the nation where students of Texas A&M University come together to say ‘thank you’ to the residents of Bryan and College Station. For the past 25 years Aggie students have participated in this annual event to show their appreciation to the surrounding community by completing service projects such as yard work, window washing, and interior/exterior painting. Although The Big Event has become the largest one-day, student-run service project in the nation, our message still remains the same – simply “thank you.”

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

S

1

DESCRIPTION

1

Elevation: Main Concourse Entry Mural Scale: 3/16"=1'-0"

Mural Graphic #129 P

19


376" 140"

Corner of Wall

4860 STERLING DRIVE BOULDER, CO 80301

108"

TEL 303 402 9233 FAX 303 402 9234

FLATSCREEN

3

Elevation: Café Wall Mural #105 (elevation flattened) Scale: 3/8"=1'-0"

L

42

39

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

NOTES

9'-8"

2

7'-3/16"

9’-0"

FLATSCREEN

3

11'-8" (140”)

1

DATE

1

9'-8"

11'-0"

Provide plywood blocking behind to accept Flatscreen mounting bracket

East Elevation: Café Wall Mural #105 Scale: 1/4"=1'-0"

19'-8" (236”)

2

SIGN TYPE

QUANTITY

P

1

DESCRIPTION

Café Wall Mural #105

North Elevation: Café Wall Mural #105 Scale: 1/4"=1'-0"

P

20


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

2'-0" 8"

60'-10"

Elevation Detail: Café Mural #111 (elevation flattened)

2

Texas A&M University

Scale: 3/16"=1'-0"

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

Soffit curves

Mural continues 8 inches up behind mini soffit

10.14.11

3M Scotchprint applied directly to painted surface

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

2'-8"

1 2

9'-0"

9'-8"

3

SIGN TYPE

QUANTITY

R

1

DESCRIPTION

Café Mural #111

1

Elevation: Café Mural #111 Scale: 3/16"=1'-0"

P

21


Drafter’s Notes: Walll Section Detail Pending & New Graphic Pending 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

H

G

F

24'-3" 4'-1 1/8"

Scotchprint mural applied to painted wall

15'-4 1/2"

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

U

1

DESCRIPTION

Stairwell Mural #147 OPTION 1

1

Elevation: Stairwell Mural #147 (Option 1) Scale: 1/4"=1'-0"

P

22


11 1/2"

3/8� Acrylic letters mounted flush to Scotchprint covered wall. Secure tightly to prevent removal

1

Detail - Dimensional Letters

Color: Paint to match Aggie Maroon with high gloss finish

Scale: 3/16"=1'-0" H

G

F

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

24'-3" Scotchprint mural applied to painted wall

4'-1 1/8"

15'-4 1/2"

Texas A&M University

11'-3/4"

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

U

1

DESCRIPTION

1

Elevation: Stairwell Mural #147 (Option 2)

Stair Mural Graphic #147 Option 2

Scale: 1/4"=1'-0"

P

23


3/8" White Sintra

Neon

Open-face, aluminum can letters.

6"

1'-6 1/2"

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

1'-7 1/2"

20"

Attached directly to wall with visible bolts through back of letter.

Vinyl applied to surfaceof Sintra logo Color: to match Aggie Maroon

Electrical required for neon

2

Detail: Reverse Pan Channel Letter (RPC)

3

Scale: 1 1/2"=1'-0"

Detail: RPC Letter - Illuminated

4

Scale: 1 1/2"=1'-0"

End View: RPC Letter - Illuminated Scale: 1 1/2"=1'-0"

5

Detail: A&M Logo Scale: 1 1/2"=1'-0"

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS

39

42 5 23

2 23

45 2 23

46 2 23

48 5 23

PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

1'-4"1'-4"

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

W

1

DESCRIPTION

Market Place Mural #174

1

Elevation: Marketplace Mural #174 Scale: 3/16"=1'-0"

P

23


3'-6"

4860 STERLING DRIVE BOULDER, CO 80301

9'-6"

TEL 303 402 9233 FAX 303 402 9234

#014

2

#017

#018

#020

#023 Texas A&M University

Elevation Details: Lower Level Flex Spirit Shop

EXTERIOR / INTERIOR SIGNS & GRAPHICS

Scale: 1/2"=1'-0" PROJECT

M?

L

K

J

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

3'-6"

Bid Drawings REVISIONS #

DATE

NOTES

1

4.21.11

UPDATED ELEVATION

2

10'-0" 9'-0" 9'-6"

3

SIGN TYPE

QUANTITY

Z

5

DESCRIPTION

Flex Area Spirit Shop

1

School Supplies

Mural Graphic #174 ?

Elevation: Lower Level Flex Spirit Shop Scale: 3/16"=1'-0"

P

24


Open-face, aluminum can letters.

4" 4860 STERLING DRIVE BOULDER, CO 80301

1'-0"

Backs of letters mechanically fasten to raised fins on attachment band.

2

Elevation Detail: RPC Letter - Non-Illuminated Scale: 1 1/2"=1'-0"

11?

3

Side View: RPC Letter - Non-Illuminated Scale: 1 1/2"=1'-0"

eq.

eq.

4

TEL 303 402 9233 FAX 303 402 9234

Detail: Attachment band Scale: 1 1/2"=1'-0"

30?

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

AA

1

DESCRIPTION

Small Dimensional Letters #188

1

Elevation: Small Dimensional Letters #188 Scale: 3/8"=1'-0"

P

25


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Elevation Detail: Marketplace Soffit Mural #180 Scale: NTS

22'-0"

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

2'-8"

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS

9'-8"

2

#

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

X

1

DESCRIPTION

1

Elevation: Marketplace Soffit Mural #180 Scale: 3/8"=1'-0"

Mural Graphic #180 P

26


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Gray Vinyl Applied to painted wall Color: TBD

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

L

1

DESCRIPTION

1

Elevation: Textbook Wall Graphic Mural #001 Scale: 3/8"=1'-0"

Mural Graphic #001 P

27


NOTE: Standard B&N Superstores sign

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

8 1/2 x 11" Paper sign insert Sign holder and template to be provided by B&N College FINAL HOURS TO BE DETERMINED

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

AT TEXAS A M UNIVERSITY

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

B

4

DESCRIPTION

Hours Sign

1

Elevation Detail: Hours Sign Scale: 3"=1'-0" P

28


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

NOTE: New Starbucks logo pending input from Starbucks Corporate

3'-0"

6" 2'-8"

Typical notes for a standard Barnes & Noble (36" x 45") illuminated double-sided cafe sign

2'-7 "

Routed out aluminum faces with show through "Barnes & Noble" and pushed through "Cafe" copy with white vinyl on 2nd surface.

1'-7 1/2"

3'-9 "

"Starbucks" logo is translucent white plex with applied vinyl graphics applied first surface.

FPO

TM

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS

Sign internally illuminated with fluorescent lamps. 6" minimum sign thickness regardless of sign size. Hidden switch.

PROJECT

#BNCO9013

DATE

10.14.11

3'-10"

2" square structural aluminum tube supports. Color: Color: MP18149

DRAWN BY / JE, PY

Bid Drawings

Weighted base for stability.

REVISIONS #

DATE

NOTES

1

8’-cord and plug to adjacent wall outlet

2 3

SIGN TYPE

QUANTITY

C

4

1'-8"

3'-7 1/2"

DESCRIPTION

Illuminated Café Stanchion

1

Elevation: Café Stanchion - Illuminated Scale: 3/4"=1'-0"

2

Side View: Café Stanchion - Illuminated Scale: 3/4"=1'-0"

P

29


NEED SECTION AT CEILING

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Stainless steel cable fastened to ceiling or to blocking above ceiling as appropriate. 3/4" aluminum sleeve covers cable Ceiling conditions vary. Verify ceiling condition for each sign location. Sleeve color: MP19891 - Airstream Sparkle Metallic

1 1/4"

6'-0"

2

Section Detail: Attachment Detail Scale: 1 1/2"=1'-0"

1 1/4" Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

10 1/2"

1 1/4"

Millwork cap Paint MP19891 Airstream Sparkle Metallic

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings

10'-3/4"

1/8" painted Sintra panels (2) Mount panels to 1"x1" painted square tube frame with concealed fasteners. Panel color: Paint panels and frames to match Aggie Maroon

Suspend 8'-0" above floor

REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

D DESCRIPTION

Department Sign

1

Elevation Detail: Department Sign Scale: 1 1/2"=1'-0"

2

End View: Department Sign Scale: 1 1/2"=1'-0"

P

30

15


2"

22"

2"

2"

3/8” Sintra panel Color: painted to match Aggie Maroon

4860 STERLING DRIVE BOULDER, CO 80301

18"

Panel applied to 2” painted tube frame Color: painted to match PMS Cool Gray 11 metallic 5 31

2"

18 1/2"

4 31

Elevation Detail: Blade Sign

3

Scale: 1 1/2"=1'-0"

14

16

2 31

End View: Blade Sign Scale: 1 1/2"=1'-0"

4

Section Detail: Mounting Bracket

5

Scale: 3"=1'-0"

19

Section Detail: Mounting Scale: 3"=1'-0"

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

7'-0"

1

6 1/2"

2

10'-0"

22"

TEL 303 402 9233 FAX 303 402 9234

2 3

SIGN TYPE

QUANTITY

E

33

DESCRIPTION

Blade Sign

P

31


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

012

013

028

102

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

103

107

109

110

#BNCO9013

DATE

10.14.11

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

E 114

1

116

118

127

DESCRIPTION

Blade Sign

Blade Sign Art Scale: NTS

P

32


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

#128

130

131

132

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

142

143

146

150

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

E 153

1

Blade Sign Art Scale: NTS

154

155

ON CORNER COLUMN AT ADIDAS STORE

156

DESCRIPTION

Blade Sign

ON CORNER COLUMN AT ADIDAS STORE P

33


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

160

161

162

167

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

168

178

179

181

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

E DESCRIPTION

Blade Sign

1

Blade Sign Art Scale: NTS

P

34


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Section Detail: Mounting Bracket

4

Scale: 3"=1'-0"

Section Detail: Mounting Scale: 3"=1'-0"

High resolution digital output mounted to painted Sintra panel

1'-6"

2"

5

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS

2"

PROJECT

#BNCO9013

Bracket attached to wall with hidden fastners

DATE

10.14.11

Painted MP19891 Airstream Sparkle Metallic

DRAWN BY / JE, PY

7'-9 1/2"

1'-6"

1/8" painted Sintra panels (2) Mount panels to 2"x2" painted square tube frame with concealed fasteners.

5 31

Bid Drawings REVISIONS #

DATE

NOTES

1

Panel color: Paint panels and frames to match Aggie Maroon 4 31

2 3

SIGN TYPE

QUANTITY

F

2

DESCRIPTION

Elevator ID

1

Elevation: Elevator ID Scale: 3/8"=1'-0"

2

Elevation Detail: Elevator ID Scale: 1 1/2"=1'-0"

3

End View: Elevator ID Scale: 1 1/2"=1'-0"

P

35


NOTE: Standard B&N College Stanchion

23”

Sign holder provided by B&N

23” 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

YOU ARE ON THE

YOU ARE ON THE

MAIN LEVEL

YOU ARE ON THE

MAIN LEVEL

LOWER LEVEL

• Checkout • General Reading • Reference

MAIN LEVEL

• Bargain • Kids Books • World News & • • • •

Periodicals Marketplace Café Customer Services Restrooms

MAIN LEVEL

• Textbooks

LOWER LEVEL

• On-line Order Pickup • School and Art Supplies • Computer Supplies

• Checkout

• Checkout

• General Reading

• General Reading

• Reference

• Reference

• Bargain

• Bargain

• World News & • •

• Prints and Frames • Buyback

MAIN LEVEL

• Kids Books

• •

Periodicals Marketplace Café Customer Services Restrooms

57” AT TEXAS A M UNIVERSITY

tamu.bncollege.com

LOWER LEVEL

• School and Art Supplies

• World News &

Periodicals

• Marketplace • Café • Customer Services • Restrooms

• Textbooks • On-line Order Pickup

• Kids Books

• Textbooks

LOWER LEVEL

57”

• Computer Supplies • Prints and Frames • Buyback

EACH SIGN DOUBLE SIDED SAME ART ON EACH SIDE

• On-line Order Pickup • School and Art Supplies • Computer Supplies • Prints and Frames • Buyback

Digital print with clear protective laminate mounted to 1/8” Sintra panel. BID INSERT PANEL ONLY STANCHIONS EXIST ON SITE.

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings REVISIONS #

DATE

NOTES

1

FPO Only Store ID TBD AT TEXAS A M UNIVERSITY

AT TEXAS A M UNIVERSITY

tamu.bncollege.com

tamu.bncollege.com

2 3

SIGN TYPE

QUANTITY

G

2

DESCRIPTION

Directory Stanchion

1

Directory Stanchion Scale: NTS

2

Elevation Detail: Level 1 Directory Stanchion Scale: 1 1/2"=1'-0"

3

Elevation Detail: Level 1 Directory Stanchion Scale: 1 1/2"=1'-0"

P

36


3'-0" 33 1/2"

B&N to provide 4 double-sided LED light boxes for retail partners to promoteproducts. 50 1/2"

6'-0"

CEILING SECTION REQUIRED

B&N POSTER GRAPHIC AREA

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

3’ x 6’ double-sided LED Light Box. Suspended from ceiling by steel cables. The LED Two Side Premium Light Box: DSA/Phototech

AT TEXAS A M UNIVERSITY

• 1 5/8” deep • Easy change graphics with snap front frame • Bright, even illumination powered by LED’s

tamu.bncollege.com

• Silver or Black finishes • Custom finishes also available • Stainless steel support cables included • UL listed Section: Attachement Detail

2

2

Scale: 3/4"=1'-0"

14.15.16.

19.

17.

Elevation Detail: Promotional Graphics

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

Scale: 3/4"=1'-0"

#BNCO9013

20.

2 37

23.

24.

DATE

10.14.11

DRAWN BY / JE

Bid Drawings REVISIONS #

BACK TO

SCHOOL FIXED PANEL

NOTES

1 2

9'-0"

FIXED PANEL

DATE

STORE HOURS

MOND MON DAY– THURSDAY, 8AM– 6PM FRID FRI D AY, 8AM– 5PM www.tamu.bncollege.com

3 AT TEXAS A M UNIVERSITY

tamu.bncollege.com X

X

2'-0"

1

Elevation: Promotional Graphics Scale: 1/4"=1'-0"

3'-11"

2'-0" 4'-0"

SIGN TYPE

QUANTITY

H

4

DESCRIPTION

MEN'S RESTROOM

Promotional Graphic

P

37


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Painted aluminum panel 30"

AT TEXAS A M UNIVERSITY

Panel color: Paint face and sides to match Aggie Maroon Satin clear coat to protect from graffiti

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

30"

DRAWN BY / JE, PE

RECEIVING

White type Screened to panel

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

XB

QUANTITY

2

DESCRIPTION

Exterior Dock Sign

1

Elevation Detail: Loading Dock Sign Scale: 1 1/2"=1'-0"

P

38


PRODUCED BY BUYENLARGE

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

66"

Digital output on stretched canvas. Mount flush face of wall. Field verify for condition.

Texas A&M University

2

Elevation Detail: Canvas Graphic Display #007

EXTERIOR / INTERIOR SIGNS & GRAPHICS

Scale: 3/4"=1'-0"

PROJECT

#BNCO9013

eq.

eq.

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1 2

5'-3/8"

3

SIGN TYPE

QUANTITY

N

1 set

DESCRIPTION

1

Elevation: Canvas Graphic Display #007 Scale: 1/4"=1'-0"

Canvas Graphic Display #007 P

39


7

10

#032

13

#033

#035

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

1

Elevation: Lower Level Concourse Entry Scale: 1/4"=1'-0"

14

13 #035

16

19

#037

23

#040

#041

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

1

12.20.10

Elevation: Lower Level Concourse Entry

DRAWN BY / JE

Scale: 1/4"=1'-0"

Bid Drawings 23

26 #043

30 #044

36 #045

39 #046

REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

I

31

DESCRIPTION

1

Elevation: Lower Level Concourse Entry Scale: 1/4"=1'-0"

Small Canvas Graphic 20’ x 30’ P

40


PRODUCED BY BUYENLARGE

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Sign #024

Sign #025

Sign #029

Sign #030

Sign #032

Sign #033

Sign #035

Sign #034

Sign #037

Sign #040

30"

20"

Sign #041

1

Sign #042

Sign #043

Sign #044

Sign #045

Sign #046

Sign #047

Sign #048 Sign #049

Elevation: Lower Level Concourse Entry

Texas A&M University

Scale: 1/4"=1'-0"

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings

F

REVISIONS #

#029

#030

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

I

31

DESCRIPTION

1

Elevation: Lower Level Concourse Entry Scale: 1/4"=1'-0"

Small Canvas Graphic 20’ x 30’ P

41


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Sign #133

Sign #136

Sign #138

Sign #137

2 1

Sign #134

Sign #140

Sign #141

Tradebook Area Wall Graphics

Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.

Scale: 3/4"=1'-0"

Sign #135

Sign #184 No #184 on Sign Location Plan FOUND

Elevation: Lower Level Concourse Entry

Texas A&M University

Scale: 1/4"=1'-0"

EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS

MAYBE WE SHOULD JUST SHOW ONE TYPICAL SIGN PLACEMENT ELEVATIONS INSTEAD OF REPEATING THE SIGN LOCATIONS PLAN IN ELEVATIONS

#

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

I

31

DESCRIPTION

1

Elevation: Scale: 1/4"=1'-0"

Small Canvas Graphic 20’ x 30’ P

42


Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.

42"

PRODUCED BY BUYENLARGE

4860 STERLING DRIVE BOULDER, CO 80301

28"

TEL 303 402 9233 FAX 303 402 9234

Sign #106

3

36

Sign #115

Sign #117

Elevation Detail: Power Aisle Wall Graphics Scale: 3/4"=1'-0"

30

26

23

#115

#117

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY /JE, PY

7

2

Elevation: Lower Level Concourse 10 Scale: 3/16"=1'-0"

13

K

14

16

Bid Drawings5 H

J

36

39 #106

19

REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

J

16

DESCRIPTION

Medium Canvas Graphic

1

Elevation: Lower Level Concourse Scale: 3/16"=1'-0"

P

43


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Sign #148

Sign #149

Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.

1

19

Sign #169

Sign #170

PRODUCED BY BUYENLARGE

Elevation: Lower Level Concourse

Sign #164

Sign #172 16

Scale: 3/16"=1'-0"

D

Sign #171

14 F

#164

G

#171

H

#172

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

10.14.11

DRAWN BY / JE, PY

3 G

Elevation: Lower Level Concourse 7

10

23

Scale: 3/16"=1'-0"

F

4

Elevation: Lower Level Concourse 26 3/16"=1'-0" Scale: D

#148

14

13 30

#149

#169

#170

16

19

Bid Drawings 36

REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

J

16

DESCRIPTION

Medium Canvas Graphic

1

Elevation: Lower Level Concourse Scale: 3/16"=1'-0"

2

Elevation: Lower Level Concourse Scale: 3/16"=1'-0"

P

44


Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.

PRODUCED BY BUYENLARGE

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Sign #165

4

Sign #166

Elevation Detail: Kid’s Department Wall Graphic Scale: 3/4"=1'-0"

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS

Sign #119

3

Sign #120

Sign #121

Sign #122

PROJECT

#BNCO9013

Elevation Detail: Customer Service #1 Backwall Graphic

DATE

10.14.11

Scale: 3/4"=1'-0"

DRAWN BY / JE, PY

23

L

26

30

36

K

Bid Drawings REVISIONS

#165

#166

#119

#120

#121

#122

#

DATE

NOTES

1 2 3

SIGN TYPE

QUANTITY

J

16

DESCRIPTION

Medium Canvas Graphic

1

Elevation: Kid’s Department Wall Graphic Scale: 3/16"=1'-0"

2

Elevation: Customer Service #1 Backwall Graphic Scale: 3/16"=1'-0"

P

45


Stainless steel cable fastened to ceiling or to blocking above ceiling as appropriate. 3/4" aluminum sleeve covers cable

White acrylic push-through letters

Ceiling conditions vary. Verify ceiling condition for each sign location. Sleeve color: MP19891 - Airstream Sparkle Metallic 5'-6"

7" 4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

10 1/2" Aluminum sign cabinet. Paint all sides of cabinet to match Aggie Maroon

11"

AGGIE STOP

Suspend 7'-2" above floor

2

Texas A&M University

Elevation Detail: Hanging Departement Sign - Illuminated

3

Scale: 1 1/2�=1'-0"

J

H

G

EXTERIOR / INTERIOR SIGNS & GRAPHICS

End View: Handing Department Sign - Illuminated Scale: 1 1/2"=1'-0"

F

PROJECT

#BNCO9013

E

DATE

10.14.11

DRAWN BY / JE, PY

Bid Drawings

AGGIE STOP

REVISIONS #

DATE

NOTES

1

FIXED PANEL

FIXED PANEL X

2 3

X

SIGN TYPE

BB

QUANTITY

1

DESCRIPTION

4'-0"

1

Illuminated Department Sign

Elevation: Level 1 Entry Scale: 1/4"=1'-0"

P

46


PRODUCED BY BUYENLARGE

48" 4860 STERLING DRIVE BOULDER, CO 80301

32"

TEL 303 402 9233 FAX 303 402 9234

Digital output on stretched canvas. Mount flush face of fixture. Field verify for condition.

Sign #003

Sign #006

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS #

Sign #016

Sign #019

Sign #026

DATE

NOTES

1 2 3

1

SIGN TYPE

QUANTITY

K

5

Textbook Area Wall Graphics Scale: 3/4"=1'-0"

DESCRIPTION

Large Canvas Graphic

P

47


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

DESCRIPTION

Adidas Store

P

48

QUANTITY


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

SIGN TYPE

DESCRIPTION

Adidas Store

P

49

QUANTITY


4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Header Graphic

Floor-to-ceiling panel graphic 8'-3 1/4"

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS

LAY-IN CEILING

PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS #

HARD CEILING

DATE

NOTES

1 2 3

Logo Blade Sign

Floor-to-ceiling panel graphic

SIGN TYPE

DESCRIPTION

Adidas Store

P

50

QUANTITY


2'-6"

Scotchprint graphic appled to aluminum panel.

4860 STERLING DRIVE BOULDER, CO 80301

.09 Aluminum Panel applied to 3/8” Sintra panel Color: Painted BLACK

TEL 303 402 9233 FAX 303 402 9234

1” x 2” painted tube frame Color: painted BLACK

8'-6"

Sign is double-sided GRAPHIC FOR POSITION ONLY TO BE PROVIDED BY ADIDAS

Aircraft cable attaches sign to hard ceiling. Verify field conditions

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings

Aircraft cable anchors to floor

REVISIONS #

DATE

NOTES

1 2 3

1

Adidas Store Graphic Panel Scale: 3/8"=1'-0"

2

Adidas Store Graphic Panel Scale: 3/8"=1'-0"

3

Side View Scale: 3/8"=1'-0"

SIGN TYPE

CC DESCRIPTION

Adidas Store Banner Sign P

51

QUANTITY

2


Aircraft cable attaches sign to hard ceiling. Verify field conditions

4860 STERLING DRIVE BOULDER, CO 80301 TEL 303 402 9233 FAX 303 402 9234

Scotchprint graphic appled to aluminum panel.

1'-5"

GRAPHIC TO BE PROVIDED BY ADIDAS

8'-0"

2

Adidas Store Graphic Panel Scale: 3/8"=1'-0"

.09 Aluminum Panel applied to 3/8” Sintra panel Color: Painted BLACK 1” x 2” painted tube frame Color: painted BLACK

Texas A&M University EXTERIOR / INTERIOR SIGNS & GRAPHICS PROJECT

#BNCO9013

DATE

12.20.10

DRAWN BY / JE

Bid Drawings REVISIONS #

DATE

NOTES

1 2 3

1

Adidas Store Graphic Panel Scale: 3/8"=1'-0"

3

Side View

SIGN TYPE

DD

Scale: 3/8"=1'-0"

DESCRIPTION

Adidas Store Topper Sign P

52

QUANTITY

1


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.