Signage Manual Manual de SeĂąalizaciĂłn 09 October 2015 (Draft Document v0.7)
Prepared for: Susanna Mander Global Brand Marketing P. (34) 971 22 44 00 x. 1808 E. susanna.mander@melia.com Prepared by:
Table of Content
General Conditions and Specifications
3
INTERIOR SIGN FAMILY
Code Compliance
5
LR
Light Ring
33
DC Corridor Directional
GRAPHIC STANDARDS 6
SS
Suspended Signs
36
The Melia Brand
7
IT
Transom ID
37
The Brands Applied to Hotels
8-9
IP
Projecting ID
38
Service Brands
10
IR
Room ID
Food & Beverage Logos
11
IG
Guest Room Identification
Colors & Finishes
12
R
Restroom ID
42-43
Typography
13
D
Dynamic Displays
45-48
Arrows
14
Pictograms
15
Construction Documents
Typesetting
16
Dibond
51
Messaging
17
Concrete Foundations
52
Post & Panel, Flag Signs
53
34-35
39-40 41
EXTERIOR SIGN FAMILY P1
Primary Site Identification
19
SI
Secondary Site Identification
20
SI
Entry Monument
21
M
Site ID Monoliths
23
DV Vehicle Directional
24-25
IB
Building Identification
26-27
PF
Pedestrian Flag
IV
Villa ID
P
Podiums
28 29-30 32
Traducciones de español que se muestran en este documento han sido proporcionados en base a los servicios de traducción de Google, y están sujetos a la revisión, interpretación y corrección por un traductor de idiomas español cualificado. Spanish language translactions shown in this document have been provided based on Google translation services, and are subject to the review, interpretation and correction by a qualified Spanish language translator.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
2
General Conditions and Specifications
GENERAL CONDITIONS
Confidentiality:
These Performance Requirements / General Conditions are an integral part of the Melia Resorts Signage Standards Manual which is referred herein as the “Design Intent Drawings”. The entity responsible for the manufacture, construction, production and implementation, their agents, sub-contractors to be referred to herein as the “Manufacturer” is responsible for all aspects of fabrication identified in this document. Any exclusions or substitutions to this document or to the Design Intent Drawings must be stated in writing to Melia Resorts, herein referred to as the “Owner” and/or the Owner’s designated representative.
Care must be taken to not leave drawings in view such that they may be seen by unauthorized parties. The Manufacturer and their subcontractors are responsible for carefully maintaining possession of all drawing and associated information (electronic or hard copy) and may be held accountable for damages that result from disclosure of confidential information
All ideas, designs, arrangements and plans indicated or presented by these drawings are owned by and are the property of the Owner, and were created, evolved and developed for use on and in connection with the specific project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of Owner and/or the Owner’s designated representative. Owner may have additional requirements or restrictions for which the Manufacturer is also responsible. Specifications of materials and methods for this project are included in these Design Intent Drawings. Manufacturers shall provide all engineering required by a licensed engineer to meet the performance intent of the Design Intent Drawings and respective specifications for each and all sign types illustrated, and will meet or exceed all local, state and national codes.
QUALITY ASSURANCE Quality of Workmanship: The Manufacturer shall be responsible for the quality and delivery of all materials and workmanship required for the execution of the contract including the materials and workmanship of any firms or individuals who act as his or her sub-contractors. Manufacturers shall be responsible for providing subcontractors with complete and up-to-date drawings, performance and material requirements, graphic schedules and other information issued by the Owner and/or the Owner’s designated representative. Performance: The Manufacturer shall base his or her proposal on the performance of all services, including all items of labor, material and equipment required to complete fabrication and installation of specified work within the time frame agreed by the Manufacturer and the Owner.
This manual is intended to be printed on A3 paper. Printing on alternate size paper will render the indicated scale of the drawings incorrect.
Dimensions: All measurements in this document are millimeters unless otherwise specified. Imperial dimensions are provided for ease of reference only, and should not be used for construction purposes. Written dimensions on the drawings shall take precedence over scaled dimensions. Manufacturer shall verify and be responsible for all dimensions and conditions shown by these drawings.
The acceptance of these drawings by vendor, bidders, Manufacturers, or Manufacturer and their agents constitutes agreement to the following conditions:
Messaging: Copy indicated on all signs is for reference only and should be reviewed with the Owner prior to application.
Design Intent Drawings are for the sole purpose of design intent only and not intended for construction purposes.
The large scale details shall take precedence over the small scale drawings.
Resulting working drawings, shop drawings and contract documents including permit documents are the sole responsibility of the Manufacturer in every respect.
Execution: Manufacturer shall notify the Owner and/ or the Owner’s designated representative of any discrepancies in the drawings, in field dimensions or conditions, and/ or changes required in construction details. Problems such as messages being too long to fit into the required formats, difficulty accurately reproducing logo or logotype components, etc., must be brought to the attention of the Owner and/or the Owner’s designated representative prior to execution. It is required that the Manufacturer not resolve any discrepancies without consulting the Owner and/or the Owner’s designated representative.
The Owner and/or the Owner’s designated representative shall review the shop drawings only for conformance with general design intent, and will in no way be responsible or liable for any results of construction from working drawings, material selection, shop drawings, contract documents or any other agreement other than agreement with Owner authorizing these documents. Any changes requested by the Owner after this document has been completed will be considered additional services.
Manufacturer’s Recommendations: The Manufacturer shall carefully study the detail drawings and make recommendations for changes if those changes improve the quality of any fabrication. The Owner anticipates that the Manufacturer will be able to make value added recommendations that improve quality, reduce cost and accelerate production time frames - such “value engineering” recommendations are desired. Such recommendations and changes including any changes in contract amount shall be approved in writing by the Owner and/or the Owner’s designated representative prior to preparation of shop drawings or fabrication.
Labeling: Only labels that are required by regulation (e.g., UL listed) may be added to the signs and should be placed in an inconspicuous as possible manner as allowed by these regulations. Stock: All materials, hardware, electrical components, finishes, etc. used to fabricate any and all components shall be “NEW” original manufacturer’s run/supply and appropriately matched to the service conditions required of the site. Reuse of existing components must be approved by the Owner.
Artwork: Electronic artwork as required by the Manufacturer for symbols or custom designed graphic components (i.e., logos, logo types, arrows or patterns) will be provided in electronically in vector formate and should not be altered. All image scaling without distortion is the responsibility of the Manufacturer. Note: Any artwork required beyond electronic artwork noted above (i.e., additional custom copy layouts, formatting for other platform(s), linotronic output, or copying to other media, etc.) will be billed to the Manufacturer on a time and materials basis by Brand On. Brand On cannot provide copies of licensed fonts. UL Compliance: Complete UL, or approved nationally recognized testing agency, compliance, as required is the responsibility of the Manufacturer. Manufacturer shall provide lighting fixtures and electrical components that meet all UL testing lab requirements for safety, operation, and construction. Fixtures and components must be UL-labeled and listed and shall indicate locations and electrical service required for review by the Owner and/ or the Owner’s designated representative unless noted otherwise. Manufacturer is responsible for all final electrical connections and if required by local regulations by licensed electrician. Light Emission: All lighting fixtures/sources shall emit a color balanced, consistent and uniform light with no browning, flickering, haloing, or any other uneven effect. Unintended “light leaks”, “hot spots” or uneven illumination will be considered defects and the product not accepted. The “color temperature” (kelvin) of the light produced shall be consistent with the manufacturer’s parameters of the specified components. Electrical Hardware: All transformers, LED power supplies, and electrical hardware, ballasts, etc. shall be concealed, non-audible and non-visible to pedestrians and vehicular traffic. Provide disconnect switch if required by governing agencies.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
3
Las Especificaciones y Condiciones Generales
CONDICIONES GENERALES
documentos.
Estos Requisitos de Desempeño / Condiciones Generales son una parte integral del Manual de Normas Meliá Resorts Señalización que se hace referencia en este documento como “Diseño Dibujos intención”. La entidad responsable de la fabricación, construcción, producción y puesta en práctica, sus agentes, subcontratistas que se denomina en este documento como el “Fabricante” es responsable de todos los aspectos de la fabricación indicadas en este documento. Cualquier exclusión o sustituciones a este documento oa los dibujos intención del diseño deben solicitarse por escrito a Meliá Resorts, denominados en este documento como el “propietario” y / o el representante designado por el propietario.
Los cambios solicitados por el propietario después de este documento se ha completado se considerarán servicios adicionales.
Todas las ideas, diseños, arreglos y planes indicados o que presentan estos dibujos son propiedad de y son propiedad del propietario, y se crearon, desarrollaron y desarrollados para su uso en y en relación con el proyecto específico. Ninguno de ideas tales, diseños, arreglos o planes será utilizada por o compartida con ninguna persona, firme, o corporación para cualquier propósito sin el permiso por escrito del propietario y / o el representante designado por el propietario. Propietario puede tener requisitos adicionales o restricciones para los que el fabricante también es responsable.
SEGURO DE CALIDAD
Especificaciones de materiales y métodos para este proyecto se incluyen en estas Diseño Dibujos Intención. Los fabricantes facilitarán toda la ingeniería requerida por un ingeniero con licencia para cumplir con la intención de rendimiento de los dibujos la intención del diseño y las respectivas especificaciones para cada uno y todos los tipos de signos ilustradas, y se cumplen o superan todos los códigos locales, estatales y nacionales. Este manual está destinado a ser impreso en papel A3. Impresión en papel de tamaño alternativo hará que la escala indicada de los dibujos incorrecta. La aceptación de estos dibujos por el proveedor, los licitadores, fabricantes, o del fabricante y sus agentes constituye un acuerdo a las siguientes condiciones: Diseño Dibujos Intención son para el único propósito de la intención de diseño y no destinados a la construcción. Resultantes dibujos de trabajo, planos de taller y los documentos contractuales que incluyen documentos de permiso son de exclusiva responsabilidad del fabricante en todos los aspectos. El propietario y / o el representante designado por el propietario deberá revisar los planos de taller sólo para la conformidad con la intención del diseño en general, y de ninguna manera responsable o responsables de los resultados de la construcción de dibujos de trabajo, selección de materiales, planos de taller, pliego de condiciones o cualquier otro acuerdo que no sea un acuerdo con el dueño de la autorización de estos
Confidencialidad: Se debe tener cuidado de no dejar dibujos en vista de tal manera que puedan ser vistos por terceros no autorizados. El fabricante y sus subcontratistas son responsables de mantener cuidadosamente posesión de todo el dibujo y la información asociada (copia electrónica o impresa) y pueden ser considerados responsables por los daños que resulten de la divulgación de información confidencial.
Calidad de Ejecución: El fabricante será responsable de la calidad y la entrega de todos los materiales y mano de obra necesarios para la ejecución del contrato, incluidos los materiales y mano de obra de las firmas o individuos que actúan como sus subcontratistas. Los fabricantes serán responsables de proporcionar los subcontratistas con completa y actualizada dibujos, requisitos de desempeño y materiales, horarios de gráficos y otra información emitida por el propietario y / o el representante designado por el propietario. Rendimiento: El fabricante deberá basar su propuesta sobre el desempeño de todos los servicios, incluidos todos los elementos de trabajo, materiales y equipos necesarios para completar la fabricación e instalación de los trabajos especificados en el plazo acordado por el fabricante y el propietario. Dimensiones: Todas las medidas contenidas en este documento son milímetros menos que se especifique lo contrario. Imperial dimensiones se proporcionan para facilidad de referencia solamente, y no deben ser utilizados para fines de construcción. Dimensiones por escrito sobre los dibujos tendrán prioridad sobre las dimensiones a escala. Fabricante verificará y será responsable de todas las dimensiones y condiciones que se muestran por estos dibujos. Mensajería: Copia indicada en todos los signos es sólo para referencia y debe ser revisado con el propietario antes de la aplicación. Los grandes detalles escala tendrán prioridad sobre los pequeños dibujos a escala. Ejecución: Fabricante notificará al propietario y / o designado el representante del propietario de cualquier discrepancia en los dibujos, en las dimensiones de campo o condiciones, y / o los cambios requeridos en los detalles de construcción. Problemas como los mensajes es demasiado largo para caber en los formatos requeridos, dificultad para reproducir con precisión los componentes logo o logotipo, etc., deben ser llevados
a la atención del propietario y / o del propietario del representante designado antes de la ejecución. Se requiere que el fabricante no resuelve cualquier discrepancia sin consultar con el propietario y / o el representante designado por el propietario. Recomendaciones del fabricante: El fabricante deberá estudiar cuidadosamente los planos de detalle y hacer recomendaciones para cambios si estos cambios mejoran la calidad de cualquier fabricación. El propietario anticipa que el fabricante será capaz de hacer recomendaciones sobre el valor añadido que mejoran la calidad, reducir costos y acelerar los plazos de producción - se desean dichas recomendaciones “ingeniería de valor”. Dichas recomendaciones y cambios, incluyendo cualquier cambio en el monto del contrato deberá ser aprobado por escrito por el propietario y / o del propietario del representante designado antes de la preparación de los planos de taller o de fabricación. Obra de arte: obras de arte electrónico como es requerido por el fabricante para los símbolos o componentes gráficos diseñados a medida (es decir, logotipos, tipos logotipo, flechas o patrones) se proporcionará en forma electrónica en el vector formiato y no debe ser alterado. Todo escalado de imagen sin distorsión es la responsabilidad del fabricante.
iluminación desigual serán considerados defectos y no aceptaron el producto. La “temperatura de color” (kelvin) de la luz producida será coherente con los parámetros del fabricante de los componentes especificados. Hardware eléctrico: Todos los transformadores, fuentes de alimentación LED, y material eléctrico, balastos, etc. se ocultan, no audible y no visible para los peatones y el tráfico de vehículos. Proporcionar interruptor de desconexión si es requerido por las agencias de gobierno. Etiquetado: Sólo etiquetas que son requeridos por la regulación (por ejemplo, la lista de UL) se puede añadir a los signos y debe ser colocado en un discreto posible forma según lo permitido por esta normativa. Stock: Todos los materiales, hardware, componentes eléctricos, acabados, etc. utilizados para la fabricación de cualquier y todos los componentes serán “NUEVO” plazo original del fabricante / oferta y debidamente adaptado a las condiciones de servicio requeridos del sitio. Reutilización de componentes existentes debe ser aprobado por el propietario.
Nota: Cualquier obra requerida allá obra electrónica se ha indicado anteriormente (es decir, los diseños de la copia de encargo adicionales, el formato de otra plataforma (s), salida de Linotronic, o copiar a otros medios de comunicación, etc.) serán facturados al fabricante de una base de tiempo y materiales por Marca On. Marca Por no puede proporcionar copias de fuentes autorizadas. UL Cumplimiento: Completa UL o aprobado agencia de pruebas reconocido a nivel nacional, el cumplimiento, como se requiere es la responsabilidad del fabricante. Fabricante proporcionará los accesorios de iluminación y componentes eléctricos que cumplan con todos los requisitos de las pruebas de laboratorio UL para la seguridad, el funcionamiento y la construcción. Accesorios y componentes deben ser UL-etiquetado y la lista e indicará los lugares y servicios eléctricos necesarios para la revisión por parte del propietario y / o el representante designado por el propietario a menos que se indique lo contrario. El fabricante es responsable de todas las conexiones eléctricas de fi nitivos y si es requerido por las regulaciones locales de electricista con licencia. Emisión de luz: Todos xtures iluminación fi / fuentes deberán emitir una luz de color equilibrado, coherente y uniforme sin dorar, vacilante, haloing, o cualquier otro efecto desigual. No intencionales “fugas de luz”, “puntos calientes” o
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
4
Code Compliance El Cumplimiento del Código
International Building Code (IBC) Fire Safety signage has been designed to conform with IBC requirements. IBC 905.7.1 Fire Cabinets IBC 1022.8 Floor Identification IBC 1022.9 Stairway Identification Signs IBC 2902.4 Restrooms
Consider ADA table and placement dialog.
IBC 3008.2 Emegency Evacuation IBC 3002.3 Elevator Emergency Signs
American Disabilities Act Requirements (ADA) All interior signs have been designed to comply with ADA Accessibility Guidelines and/or code requirements. Modification of text and braille size, placement or construction is prohibited. Provide copy proofed braille to ADA guidelines for permanent room signs requiring Grade 2 Braille. Additional requirements are provided herein.
UNDER DEVELOPMENT
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
5
GRAPHIC STANDARDS NORMAS GRÁFICAS
The Melia Brand La Marca Meliã The Meliã brand is it’s own unique mark. The Meliã brand is to be utilized as shown herein, and can not be altered.
The Generic Brand La Marca Genérica
The Meliã brand is used on all exterior identification and primary site directional signs at the property perimeter only. Once inside/on the property the use of the brand is omitted on signage.
X
Color
1,74X
The Meliã brand is to be always be applied in the two colors shown. The Meliã brand when applied to a field of color is to appear in accordance with the respective message color for each resort scheme, and as black in the urban scheme.
8,91X
Proportions Proporciones
Please refer to Meliã Corporate Visual Identity Manual for additional information and contact details to secure approved artwork for these brands and icon. La marca Meliá se utiliza en todos los signos de identificación exterior y direccionales sitio primario en el perímetro propiedad. Una vez dentro de la propiedad se omite / el uso de la marca de señalización.
X
X
Color La marca Meliá es estar siempre debe aplicarse en los dos colores que se muestran. La marca Meliá cuando se aplica a un campo de color es a aparecer de acuerdo con el color del mensaje respectivo para cada esquema de recurso, y como negro en el esquema urbano. Por favor, consulte Meliá Manual de Identidad Visual Corporativa de la información y datos de contacto adicionales para asegurar obra aprobado para estas marcas y el icono.
Build Diagram Esquema constructivo
1.5X
Clear Zone
1.5X
Zona de protección From this page on, the “n” is the reference measurement from which to calculate all logo proportions. "X" defines proportions for the clear zone for signage applications only.
Clear Zone Zona de protección
Desde esta página y en adelante, la “n” es la medida de referencia para calcular todas las proporciones del logotipo. "X" define las proporciones para la zona de protección únicamente para aplicaciones de señalización.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
7
The Brands Applied to Hotels La Marcas Aplicada a Hoteles The Brand and Its Versions La Marca y Sus Versiones
La Marca Aplicada a Hoteles The Brand Applied To Hotels
Version A. Main Centered Versión A. Principal Centrado
Please refer to Meliã Corporate Visual Identity Manual for additional information and contact details to secure approved artwork for these brands and icon.
Versión C. Una Linea Version C. One Line
Version B. Main Horizontal Versión B. Principal Horizontal
Por favor, consulte Meliá Manual de Identidad Visual Corporativa de la información y datos de contacto adicionales para asegurar obra aprobado para estas marcas y el icono.
X
X X
2,65n 2,1n
2,8n n
2,8n
1,55n
1,18n n
n 12,35n
Proportions Proporciones
12,9n
Proportions Proporciones
Proportions Proporciones
n n
n n
n
Build Diagram Esquema constructivo
n
1.5X
Build Diagram Esquema constructivo
Build Diagram Esquema constructivo
1.5X
1.5X
1.5X Clear Zone
1.5X
1.5X
Zona de protección / Clear Zone
Clear Zone Zona de protección Zona de protección Zona de protección Clear Zone
Clear Zone Zona de protección
It must always be used together with “Hotels & Resorts” or the hotel’s name, except for highlevel signage, where it should appear without this element.
Clear Zone Zona de protección
Siempre se deberá usar acompañada de la denominación “Hotels & Resorts” o los nombres de los hoteles, exceptuando su aplicación en rótulos en altura, donde se aplicará sin esta denominación.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
8
The Brands Applied to Hotels La Marcas Aplicada a Hoteles
Version D. Two Lines Versión D. Dos Lineas
Version E. Horizontal Versión E. Horizontal
Service brands are used solely on signs that identify the specific upscale services and amenities across a given property. Service brands are not to be used on directional signs. When a service needs to be listed on a directional sign it is to be done so in accordance with Typography and Bilingual Messaging. These brands are a unique pieces of artwork which should not be recreated or altered in any way.
Clear Space A brand must be surrounded by an area that is free of any text, graphics, borders, or prominent architectural details such as window, sills, reveals, awnings, etc. This area is called “clear space.” In the exhibits at left, clear space “X” is determined using the height of the portion of the brand defined by the blue X square.
X n 3,23n
Minimum clear space also applied when and where a brand or icon appears on a field of color.
0.93n
Proportions Proporciones
1,8n 1,61n
Por favor, consulte Meliá Manual de Identidad Visual Corporativa de la información y datos de contacto adicionales para asegurar obra aprobado para estas marcas y el icono.
1,26n
S I E R R A N E VA D A
n
1,24n n
Proportions Proporciones
Please refer to Meliã Corporate Visual Identity Manual for additional information and contact details to secure approved artwork for these brands and ic
n
n
Build Diagram Esquema constructivo
.5n .5n
n
Clear Zone / Zona de protección
Build Diagram Esquema constructivo
Clear Zone Zona de protección
X Clear Zone
X
From this page on, the “n” is the reference measurement from which to calculate all logo proportions. "X" defines proportions for the clear zone. Zona de protección
Clear Zone Zona de protección
Desde esta página y en adelante, la “n” es la medida de referencia para calcular todas las proporciones del logotipo. "X" define las proporciones para la zona de protección.
Marcas de servicio se utilizan únicamente en los signos que identifican los servicios y comodidades de lujo específicas a través de una determinada propiedad. Marcas de servicio no deben ser utilizados en las señales direccionales. Cuando un servicio necesita ser incluido en una señal de dirección es de hecho, de acuerdo con la tipografía y mensajería Bilingüe. Estas marcas son unas piezas únicas de obras de arte que no debe ser recreados o alterados de ninguna manera.
Zona de Protección Una marca debe estar rodeado por un área que está libre de cualquier texto, gráficos, bordes, o detalles arquitectónicos prominentes como ventana, alféizares, revela, toldos, etc. Esta zona se llama “espacio libre”. En las exposiciones a la izquierda, espacio libre “X” se determina usando la altura de la parte de la marca definida por el X cuadrado azul. El espacio libre mínimo también se aplica cuando y donde una marca o un icono aparece en un campo de color. Por favor, consulte Meliá Manual de Identidad Visual Corporativa de la información y datos de contacto adicionales para asegurar obra aprobado para estas marcas y el icono.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
9
Service Brands Marcas de Servicios The Level
Kids & Co.
Meliã has created standard F & B logos for those venues which exist across the different resorts. For consistency and branding all resorts must use the same logos. No variations allowed. Please refer to Meliã Corporate Visual Identity Manual for additional information and contact details to secure approved artwork for these Service Brands Meliã ha creado logotipos estándar A & B para aquellos lugares que existen en las diferentes estaciones. Para mantener la coherencia y la marca de todas las estaciones debe utilizar los mismos logotipos. No hay variaciones permitidas. Por favor, consulte Meliá Manual de Identidad Visual Corporativa de la información y datos de contacto adicionales para asegurar obra aprobado para estas marcas de servicio.
.5X
Clear Zone
. X
.5X
Zona de protección
.5X
.5X
Proportions and Clear Zone Proprociones y Zona de protección
The the level logo is made of its own typeface featuring a central V. All logo elements are to be composed in Futura font in its regular version with the spacing and proportions shown above. El logotipo de THE LEVEL esta compuesto por una tipografía propia y con una V central. Todos los elementos del logo NIVEL consistirán en el tipo de letra FUTURO en su versión regular y un ajuste entre caracteres y proporciones se muestra arriba.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
10
Food & Beverage Logos Alimentación y Bebidas Logotipo
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
11
Colors & Finishes Color y Acabados Esquemas Resort / Resort Schemes Clara
Resort interior and exterior signage uses Obscura or Clara print on panel finish to reflect the two options for signage schemes, and as selected are to be consistent across the whole of an individual property. The Urban scheme uses brushed aluminum as its signage substrate. The exceptions to this are special identification signs, exterior totem directional signs, and fire safety signage.
Obscura
Note: The colors shown on this page and throughout the guidelines may not accurately reflect the actual color, depending on publication methods of this manual. Regardless of fabrication method, colors must be consistent throughout the signage package.
Imprimir en Acabado del panel, 600 ppp mínimo, comuníquese Modulex Print on Panel Finish, 600dpi minimum, contact Modulex
Paint
PMS
C
C
M
M
Y
Pintar
PMS
A
Meliã Blue / Azul
TBD
534
Meliã Bronze / Bronce
TBD
404
White / Blanco
TBD
White
0
0
0
Black / Negro
TBD
Black
0
0
Silver / Plata
TBD
8001
50
40
Obscura White / Blanco
TBD
TBD
TBD
Clara Yellow / Amarillo
TBD
7556
Clara Red / Rojo
TBD
8223
77
100
Red / Rojo
TBD
185
Yellow / Amarillo
TBD
123
Green / Verde
TBD
335
K
G
B
HEX
3M Translucent Film
3M Reflective Film Application
HEX
3M Opaco Capa
3M Tanslúcido Capa
3M Reflectante Capa Aplicación
R
G
B
97.6 84.6 36.2 27.3
31
23
94
1F355E
TBD
TBD
N/A
51.2 48.7 56.5 17.8
120
110
99
786E63
TBD
TBD
N/A
0
255
255 255
FFFFFF
3650-10
3630-20
680-10
0
100
0
000000
3650-12
TBD
N/A
40
0
124
124 117
7C7C75
TBD
TBD
N/A
The Level
TBD
TBD
TBD TBD
TBD
TBD
TBD
N/A
Clara Sign Message
100
14
91
43
46
231F20
TBD
TBD
N/A
Obscura Sign Message
0.9
100 92.1
0
235
0
41
EB0029
3650-263
TBD
N/A
Regulatory Symbols
0
23.5 91.0
0
0
149
58
00953A
7725-15
TBD
N/A
Regulatory Symbols
1.9
0
149
58
00953A
TBD
TBD
N/A
Regulatory Symbols
TBD TBD
98.4 11.6 100
K
R
3M Opaque Film
0
0
Resort interior y señalización exterior utiliza Obscura o Clara imprimen en el acabado del panel para reflejar las dos opciones a los regímenes de señalización, y como son seleccionados para ser coherente en el conjunto de una propiedad individual. El esquema urbano utiliza aluminio pulido como su sustrato señalización. Las excepciones a esto son signos especiales de identificación, señales direccionales tótem exteriores, y señalización de seguridad contra incendios. Nota: Los colores que se muestran en esta página y en todas las directrices pueden no reflejar con precisión el color real, en función de los métodos de publicación de este manual. Independientemente del método de fabricación, los colores deben ser consistentes en todo el paquete de señalización.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
12
Typography Tipografía E The ITC Avante Garde Gothic Medium font is used for all application of the Meliã brand.
Typeface for Signage Message Tipografía para el Mensaje de Señalización
The TW Cent MT is used for all sign messaging throughout the signage program:
English/Ingles ITC Avant Garde Gothic Medium / Medio
ITC Avant Garde Gothic Medium
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz !?.,:;“”@#%&1234567890
Used for Spanish body text on most interior and exterior sign types.
Local Language ITC Avant Garde Gothic Book / Libro
ITC Avant Garde Gothic Demi
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz !?.,:;“”@#%&1234567890
ITC Avant Garde Gothic Book Used for English body text on most interior and exterior sign types.
ITC Avant Garde Gothic Light Used for subtext where applicable.
Used for warning and regulatory text. Used for emphasis in dual text weight applications, in conjunction with ITC Avant Garde Gothic Medium and where emphasis of sign message is required. l tipo de letra ITC Avante Garde Gothic Medio se utiliza para todas las aplicaciones de la marca Meliá. El Cent MT TW se utiliza para todos los mensajes de signo a lo largo del programa de señalización:
ITC Avant Garde Gothic Medio
Body Copy ITC Avant Garde Gothic Light / Ligero
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz !?.,:;“”@#%&1234567890
Se utiliza para el cuerpo del texto Español en la mayoría de los tipos de signos interiores y exteriores.
ITC Avant Garde Gothic Libro Se utiliza para el cuerpo del texto Inglés en la mayoría de los tipos de signos interiores y exteriores.
ITC Avant Garde Gothic Ligero Se utiliza para subtexto en su caso
ITC Avant Garde Gothic Demi
Warning ITC Avant Garde Gothic Demi
ABCDEFGHIJKLMNOPQRSTUVWXYZ abcdefghijklmnopqrstuvwxyz !?.,:;“”@#%&1234567890
Se utiliza para la alerta y el texto normativo. Se utiliza para dar énfasis en aplicaciones de doble peso de texto, junto con ITC Avant Garde Gothic Medio y donde se requiere énfasis del mensaje de signo.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
13
Arrows Arrows Arrows Flechas 0 .1
.10X
X
1.5X
All arrows have been designed and selected to create a unique system to support a signs message where required. These symbols are individual pieces art and are not to be changed, revised, or altered in any way. Please contact Global Branding for approved artwork files.
X
X
1.5X
Color Arrow centers on message
Arrows are to be applied to signs in required resort or urban schemes colors. Regulatory pictograms may use colour depending on application. The colour usage table list rules for appropriate use of colour. Todas las flechas y pictogramas han sido diseñados y seleccionados para crear un sistema único para apoyar un mensaje signos cuando sea necesario. Estos símbolos son piezas individuales arte y no deben ser cambiadas, revisadas o modificadas de ningún modo. Por favor, póngase en contacto con Global Branding para archivos de diseño aprobados.
Relationship Relación
Weight Weight
Color Forward/Left Avanzar/Izquierda
Forward Avanzar
Los flechas se han de aplicar a las señales en la estación requerida o esquemas de colores urbanos. Pictogramas reguladoras pueden utilizar el color en función de la aplicación.
Forward/Right Avanzar/Derecho
La lista de tabla de uso de color reglas para el uso apropiado del color.
Left Izquierda
Right Derecho
Direction Dirección
Thicker
Thick
Existing
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
14
Pictograms Pictograms Regulatory Pictograms Pictograms Regulatorios
Restroom Aseos
Men Hombres
All pictograms have been designed and selected to create a unique system to support a signs message where required. These symbols are individual pieces art and are not to be changed, revised, or altered in any way. Please contact Global Branding for approved artwork files.
Women Mujeres
Elevator Elevador
Helio Ice
Golf Course Campo de Golf
Football Field Campo de futbol
Tennis Courts Canchas de tennis
Wet Floor Piso mojado
The symbols are sized porportionately to a universal border element which is not printed on the signs. In this document, pictogram sizes are measured from the border element, and not fromthe symbol itself. When combining pictograms on one sign, the border element should be identical in size. Should additional pictograms be required, please obtain artwork approval prior to use.
Color Pictograms are to be applied to signs in required resort or urban schemes colors. Regulatory pictograms may use colour depending on application. Handicapped Minusválido
Stair Escalera
Luggage Equipaje
Telephone Teléfono
Restaurant Restaurante
Shops Lojas
SPA SPA
Reception Recepción
No pushing No empujar
The colour usage table list rules for appropriate use of colour. Todas las flechas y pictogramas han sido diseñados y seleccionados para crear un sistema único para apoyar un mensaje signos cuando sea necesario. Estos símbolos son piezas individuales arte y no deben ser cambiadas, revisadas o modificadas de ningún modo. Por favor, póngase en contacto con Global Branding para archivos de diseño aprobados.
Bar Bar
Café Café
Meeting Sesión
Running Path Pista de Atletismo
Shower Ducha
Pool Piscina
Beach Playa
Parents are responsible for their children
Do not run No corras
Si se requieren las pictogramas adicionales, por favor obtenga la aprobación del diseño antes del uso.
In case of emergency
CONTACT EXT. 8
Parking Estacionamiento
Taxi Stand Parada de Taxis
First Aid Primeros Auxilios
Strollers Cochecitos
Day Care Guardería para los Niños
Place gargabe inside dumpster
In case of emergency En caso de emergencia
8am - 7pm
Swimming Pool Hours Horario Piscina
Los símbolos son de tamaño porportionately a un elemento de frontera universal que no se imprime en las señales. En este documento, tamaños pictograma se miden desde el elemento de frontera, y no fromthe símbolo en sí mismo. Cuando la combinación de pictogramas en una señal, el elemento de frontera debe ser idéntico en tamaño.
Llifeguard Salvavidas
Color Los pictogramas se han de aplicar a las señales en la estación requerida o esquemas de colores urbanos. Pictogramas reguladoras pueden utilizar el color en función de la aplicación. La lista de tabla de uso de color reglas para el uso apropiado del color.
7pm - 8am
Bicycles Bicicletas
In Case of Fire En Caso de Fuego
Fire Extinguisher No Smoking Extintor de Incendios No Fumar
Smoking Area Do not jump Área de Fumadores No saltes
Food not allowed in the pool
Swimming Pool Hours No lifeguard No hay salvavidas Horario Piscina
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
15
Typesetting Tipografía
Wayfinding Manera Hallazgo
Translation Immediately Follows Primary Language Traducción Sigue Inmediatamente Idioma Principal 1.5X
eq.
Grand Room • Gran Sala
X
Centers on sign
eq.
Tracking está ajustado a 0 en todos los casos. Si la longitud del mensaje requiere; de seguimiento se puede ajustar a menos de 0, pero no superior a -25. Habitaciones con mensajes de signos de identificación se deben establecer en letras mayúsculas, se plantean táctil, y grado 2 Braille es ser proporcionado para cada uno.
X 1.5X X
Direccional X X 1.5X 2X
Conference Room Conferencia Habitacion Main Pool Piscina Principal
Todo señalización encontrar el camino se encuentra en el caso del título. El cuerpo del texto escrito Secundaria caso típico frase. Destinos deben ser agrupados por la dirección (hacia adelante, izquierda, derecha) y se la pueden enumerar por más cercana a más distancia. Puntuacion Un período no es necesario para la mensajería sola palabra. Una bala se utiliza la legibilidad, donde por frases consectuitve, o énfasis, tales como; “Por favor, use zapatos. No hay trajes de baño permitido.”
Multiple Line Multiple Line
The applications of type and message is to be applied consistent across the family of signs and the following rules are made to ensure the look and integrity is on brand.
X 1.5X X
2X
Conference Room Conferencia Habitacion Grand Room • Gran Sala
X X 1.5X
Arrow centers on message
Entre letras es conforme a lo establecido por la altura X se muestra. Relación se estableció la base en el múltiplo de X indicado.
La identificación de la habitación:
Single Line Single Line
Arrow centers on message
RESTROOM • ASEOS
Las aplicaciones de tipo y el mensaje se va a aplicar coherente en toda la familia de signos y se hacen las siguientes reglas para asegurar el aspecto y la integridad es de marca.
Tracking is set to 0 in all cases. If message length requires; tracking can be set to less than 0, but no greater than -25. Room Identification:
2X
Main Pool Piscina Principal
Letterspacing is as established by X height shown. Relationship are established base on the multiple of X indicated.
Room identification sign messages are to be set in all capital letters, are raised tactile, and Grade 2 braille is to be provided for each. Directional All wayfinding signage is set in title case. Secondary body copy written typical sentence case. Destinations are to be grouped by direction (forward, left, right) and are the be listed by nearest to furthest away. Punctuation A period is not required for single word messaging. A bullet is used readability, where for consectuitve sentences, or for emphases such as; “Please wear shoes. No bathing suits allowed.”
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
16
Messaging Mensajería Multiple Messages Grouped by Language Múltiples mensajes agrupados por idioma
Todos los mensajes signo permanente es ser bilingüe.
Warning & Life Safety Warning & Life Safety
El español es el idioma principal para la mensajería signo y se muestra en la ITC Avant Garde Gothic Medium. Español es que aparezca en primer lugar en todos los casos.
TENNIS COURTS
Inglés es el idioma secundario para los mensajes de signos y se muestra en la ITC Avant Garde Gothic Light. Inglés aparece segundo en todos los casos.
OPEN: 8:00 a.m. - 8:00 p.m.
Cuando traducciones en español e inglés se colocan en una sola línea, una bala se utiliza para separar el texto.
It is prohibited to use the Tennis Courts without wearing proper foot wear. The Hotel is not responsible for accidents which may occur within this facility. Reservations can be made for one tennis court for a one hour period. The tennis court will be saved for 10 minutes only after your reservation time. If there are no further reservations, you will be able to use the tennis court as long as you wish. Court available with electricity.
Copia española se muestra en este documento es sólo para fines ilustrativos, y sujetos a revisión para su aprobación. All permanent sign messaging is to be bilingual. Spanish is the primary language for sign messaging and is shown in ITC Avant Garde Gothic Medium. Spanish is to appear first in all cases.
UNDER DEVELOPMENT
English is the secondary language for sign messaging and is shown in ITC Avant Garde Gothic Light. English appear second in all cases. When Spanish and English translations are placed on a single line, a bullet is used to seperate the text. Spanish copy shown in this document is for illustration purposes only, and subject to review for approval.
PISTAS DE TENIS ABIERTO: 8:00 a.m. - 8:00 p.m. Esta prohibido usar las pistas de tenis sin el calzado adecuados a estas.
El hotel no se hace responsable de los accidentes que peudan occurrir en las instalciones de las pisastas de tenis. Le informamos que su reserva de canchas de tennis se mantendra valida 10 minutos despues que usted haya realisada la reserva. Deuies de 10 minutos, pondran ocupar solamente una cancca por una hora dentra del horario establecido. En caso de no tener registrano mas reservas en este dia poderam ustizas las canches el tiempo que gustem. De iluminacion de las canachs.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
17
Site Identification Site Identification
Property Identification
P1. ~ Primary Site Identification
Identificación de la Propiedad
P1. ~ Identifcación Sitio Principal arrojar luz a través de toda la marca . Logotipos nivel pueden aparecer en la misma señal si un complejo comparte una entrada común. Por favor, consulte el Manual de Identidad Visual Corporativa Meliá para la restricción de la colocación del logotipo. El tamaño y la configuración de la señal de identificación del sitio deben ser analizados de forma individual sobre la base de diseño de la arquitectura y el paisaje, los volúmenes de tráfico, distancia de visión, orientación sitio y reglamentos locales. Planos de taller de ingeniería para todos los signos de identificación del sitio primario deben ser suministrados por el fabricante de la muestra antes de la fabricación. Foto de Ejemplo Example Photo
Primary Site Identifcation signs are amongst the most important application of our brand identity. They are the first thing guests see as they arrive on site. Primary Site Identifcation signs are located at all the main entrances to the Resort and are to be integrated with a landscape architecture. The unique features of the main site identification signs are the use of logo elements against a wall finished with coralina stone. Brands are to be applied as reverse pan channel aluminum letters with halo illumination, painted in accordance with respective brand colours. Electrical and power supply is to be concealed within mounting surface, and is to be cooridinated with landscape architect in advance of construction.
Identificación del Sitio de Doble Marca Dual Brand Site Identification
Foto de Ejemplo
Signos identifcación sitio principal se encuentran entre la aplicación más importante de nuestra identidad de marca. Ellos son lo primero que ven los clientes a medida que llegan en el sitio.
If in the event halo illumination is not a practical applications, the use of pin mounted plate letters, painted in accordance with respective brand colours, is an acceptable application of the brand and ground mounted lighting is to be provided to cast light across the entire brand.
Signos identifcación sitio principal se encuentran en todos los principales accesos al Resort y están a integrarse con una arquitectura de paisaje.
Level logos may appear on the same sign if a resort shares a common entryway. Please see Meliã Corporate Visual Identity Manual for restrictions on logo placement.
Las características únicas de los principales signos de identificación de sitio son el uso de elementos de la insignia contra una pared terminada en piedra coralina.
The size and configuration of the Site Identification sign must be analysed on an individual basis based on architectural and landscape design, traffic volumes, viewing distance, site orientation and local bylaws.
Example Photo
Las marcas son para ser aplicado como cartas de aluminio canal pan inversa con la iluminación de halo, pintados de conformidad con los respectivos colores de la marca. Suministro eléctrico y el poder se oculta dentro de la superficie de montaje, y debe ser cooridinated con el arquitecto del paisaje antes de la construcción.
Identificación Único Sitio de la Marca Single Brand Site Identification
Noche Ilustración Night Illustration
Engineered shop drawings for all primary site identification signs are to be supplied by the sign manufacturer prior to fabrication.
Si en el caso de iluminación de halo no es una aplicación práctica, el uso de pines montados letras placa, pintado de conformidad con los respectivos colores de la marca, es una aplicación aceptable de la marca y la tierra montado iluminación es que debe proporcionarse a
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
19
Property Identification
SI2. ~ Secondary Site Identification
Identificación de la Propiedad
SI2. ~ Identifcación Sitio Secondario On properties with an additional resort, ie. The Reserve occur a Secondary Site Monument is to be positioned in front of the primary entry, perpendicular to the path of vehicular traffic. Where multiple public entries exist into the main Resort buildings should be identified based on the services provided beyond the entrance. Brands are to be applied as reverse pan channel aluminum letters with halo illumination, painted in accordance with respective brand colours. Electrical and power supply is to be concealed within mounting surface, and is to be cooridinated with landscape architect in advance of construction.
BRACO VILLAGE
BRACO VILLAGE
Entry Monument
If in the event halo illumination is not a practical applications, the use of pin mounted plate letters, painted in accordance with respective brand colours, is an acceptable application of the brand and ground mounted lighting is to be provided to cast light across the entire brand. The size and configuration of the Secondary Site Identification sign must be analysed on an individual basis based on architectural and landscape design, traffic volumes, viewing distance, site orientation and local bylaws. Engineered shop drawings for all primary site identification signs are to be supplied by the sign manufacturer prior to fabrication.
Stoned Clad
Stucco
Horizontal Monument
Bracketed Entry
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
20
Property Identification
SI3. ~ Entry Monument
Identificación de la Propiedad
SI3. ~ Entry Monument
Set Entry Monument forward of center to allow for new tall planting behind.
Only low growth ground cover on front side of Entry Monument.
Plan View
Angle toward entry road.
Cast grey concrete cap.
Scale: 3/32” = 1’ - 0”
6'-10 1/2"
4 1/4"
1'-0" approx.
Typical to letters above. Stucco veneer to match lightest color used on building color scheme
9 13/16"
1'-1 3/4"
Ex. Entry Wall Stone Veneer
1/4” thk. plate letters, pin mounted w 1/2” standoff, if landscape illum. is required.
CMU construction Cast grey concrete trim cap.
BRACO VILLAGE
Stone veneer to match entry wall.
11"
5
1/2"
4 1/2"
5 1/2"
2'-9 1/2" approx.
4'-0"
1 1/2” d fab’d alum. channel letter LED illumination. Electrical and internal raceway provided by GC.
Elevation
Scale: 3/4” = 1’ - 0”
End View
Scale: 3/4” = 1’ - 0”
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
21
Resort Clara Scheme Urban Scheme EsquemaResort Urbana Esquema Clara
Sign Family Sign Family
Clara Resort Scheme
M ~ Site ID Monoliths
Esquema Clara Resort
M ~ Site ID Monoliths
1524 5'-0"
3665 12'-0 1/4"
BRACO VILLAGE
2450 96 1/2"
End View
1891 6'-2 1/2"
2900 114 1/4"
M2. Monolith Clara
M1. Monument Clara
Scale: 1:20
BRACO VILLAGE
M3. Monolith Clara
End View
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
23
Clara Resort Scheme
DV ~ Vehicle Directional
Esquema Clara Resort
DV ~ Direccional del Vehículo The vehicular directional sign are to be used within Resort property and placed perpendicular to the direction of travel. This sign type are not be used for pedestrian traffic. Landscaping must be managed to ensure vegetation does not encroach into the sight lines of the viewer. Should ambiant lighting not be sufficient, ground mount lighting should be installed to flood the entirety of the sign.
70 dia. 2 3/4" 1000 39 1/4"
Should the amount of text required exceed the minimum spacing, use next size of sign larger from the VD sign catalog. Aluminum panel with print on panel (POP) Obscura, or Clara finish. Finish to be the same across an individal property.
400/15 3/4"
900/35 1/2"
Panel:
1000/39 1/4"
90 dia. 3 1/2"
1000 39 1/4"
Illumination: Ground lighting is to be provided to adequately illuminate the whole of the sign. Foundation: Pour in place concrete footing at minumum, per engineered requirements. Provide mow barrier of 50 75mm around perimeter of post(s).
Valet
900/35 1/2"
200/7 3/4"
1000/39 1/4"
2500/98 1/2"
CLARA DV2. Vehicle Regulatory
OBSCURA DV1. Vehicular Directional - Post Mount
Scale: 1:15
CLARA DV3. Vehicle Directional
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
24
Clara Resort Scheme
DV ~ Vehicle Directional
Esquema Clara Resort
DV ~ Direccional del Vehículo Building identification, post mount signs are double sides and are to be located prominent and adjacent to entry of a building providing an service or amenity to the resort guest. Placement is to be perpendicular to path of travel.
1000/39 1/4" X 1.5X X
Landscaping
Panel:
X
1000 39 1/4"
2X
70 dia. 2 3/4"
Main Entry
X X
Arrow centers on message
Where placement of a building identification, post mount sign is parallel to the building entry and only visible from one direction, it is permissable to supply information on the prominent side visible to the resort guest. Aluminum panel with print on panel coralina finish, w/ 25mm rule and signs message printed to match PMS 8004
400/15 3/4"
900/35 1/2"
Copy: Applied vinyls. Illumination: Ground lighting is to be provided to adequately illuminate the whole of the sign.
Main Reception Tennis Courts
CLARA DV2. Vehicle Regulatory
Foundation: Pour in place concrete footing at minumum, per engineered requirements. Provide mow barrier of 50 75mm around perimeter of post(s).
X 1.5X X
eq. X
Valet
Centers on sign
eq.
DO NOT ENTER
Valet Parking Only
Centers on sign
1.5X
2X
Centers on sign
1.5X
eq.
900/35 1/2"
200/7 3/4"
1.5X
eq.
DO NOT ENTER
X
Centers on sign
CLARA DV3. Alternate Message
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
25
Clara Resort Scheme
IB ~ Building Identification
Esquema Clara Resort
IB ~ Building Identification
CONVENTION CENTER
Building Identification Foto de Ejemplo Example Photo
Night Illustration
Foto de Ejemplo Example Photo
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
26
Clara Resort Scheme
IB ~ Building ID
Esquema Clara Resort
IB ~ Building ID
1000/39 1/4" 1.5X
X
400/16”
900/35 1/2"
CONVENTION CENTER CENTRO DE CONVENCION
1.5X
CONVENTION CENTER CENTRO DE CONVENCION
1000 39 1/4"
X
70 dia. 2 3/4"
eq.
YHI SPA & HEALTH CLUB
eq.
CLARA IB2. Building ID - Post Mount
120/4 3/4"
800/32”
YHI SPA & HEALTH CLUB
900/35 1/2"
YHI SPA & HEALTH CLUB
900/35 1/2"
200/7 3/4"
70 dia. 2 3/4"
CLARA IB3. Building ID - Post Mount
X
Scale: 1:15
Centers on sign
CLARA IB4. Building ID - Post Mount
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
27
Clara Resort Scheme
PF ~ Pedestrian Flag
Esquema Clara Resort
PF ~ Pedestrian Flag
4 3/4” x 31 1/2”
4 3/4” x 24”
4 3/4” x 16”
4” x 31 1/2”
4” x 24”
4” x 16”
4 3/4” x 16” Pictogram Layouts
4 3/4” x 16” Pictogram Layouts
CLARA PF ~ Pedestrian Flag Sign
Scale: 1:15
4 3/4” x 31 1/2” Pictogram Layouts
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
28
70 dia. 2 3/4"
IV ~ Villa ID
Esquema Clara Resort
IV ~ Identificación de Villa
800 31 1/2"
39
400/15 3/4"
Clara Resort Scheme
Villa
Villa
40
3931 - 3938 3921 - 3928 3911 - 3918
900/35 1/2"
3931 - 3938 3921 - 3928 3911 - 3918
CLARA IV1. Villa Identification, Double Faced
Reverse Side
Scale: 1:10
800 31 1/2"
39
Villas
3931 - 3938 3921 - 3928 3911 - 3918
40
4031 - 4038 4021 - 4028 4011 - 4018
900/35 1/2"
400/15 3/4"
70 dia. 2 3/4"
Scale: 1:10
CLARA IV1. Villa Identification, Single Face
Scale: 1:10
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
29
Clara Resort Scheme
IV ~ Villa ID
Esquema Clara Resort
IV ~ Identificación de Villa OPTIONAL
PREFERRED
CLARA IV2. Hypothetical Placement Elevation
CLARA IV2. Hypothetical Placement Elevation
CLARA IV2. Hypothetical Placement Elevation
475 615 18 3/4" 24 1/4"
610/24"
765 30"
610/24"
CLARA IV2. Villa Building Numbers
Scale: 1:10
CLARA IV3. Villa Building Number Sign
Scale: 1:10
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
30
Resort Clara Scheme Urban Scheme EsquemaResort Urbana Esquema Clara
Interior Sign Family Interior Sign Family
Clara Resort Scheme
P ~ Podiums
Esquema Clara Resort
P ~ Podios
337 1'-1 1/4"
Aliata venis nus explacide vent dolenti usanis abor apiet dem faccatur, sin cupta volore odiorem quunt ut voluptaepro et facerio nserios parior aditemqui delibus sitas sant ea conseru mquiam ratibusam in pori dolorrum volut doluptati tem.
251 10"
Bell Captain
Itat labo. Emolum voluptur sus natus is eaquia velibero descia nostem volliquam facessit eic tem qui sit occatusdae non placcup taquis vernat quam, nobit verciligent quibus as delit, quam endiam haribus aut od maiossum enimaio recerovid quisimagnam fugia as maioratem necti utemperro mos et reri reperum faci Alternate Material Specification: Dibond
CLARA P1. Podium Plaque
Typical Placement Elevation
CLARA P2 . Podium Plaque
Scale: NTS
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
32
OBSCURA LR1. Light Ring - Round, Elevation Detail Custom
OBSCURA LR1. Light Ring - Round, Elevation Custom
Clara Resort Scheme
LR ~ Light Ring
Esquema Clara Resort
LR ~ Light Ring
Scale: 1:15
Scale: 1:30
OBSCURA LR2. Light Ring - Square, Plan View Custom
Scale: 1:30
OBSCURA LR1. Light Ring - Round, Plan View Custom
Scale: 1:30
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
33
Clara Resort Scheme
DC ~ Corridor Directional
Esquema Clara Resort PREFERRED
Ti con erunt utet dolores reiur, cum fugiatur? Laborpo reictur ehendia coressi si comnis molluption eatatio mos doloreperae pliquatis aligendis qui adipite nonem reic to ium, sus re et odis aliciiscim simus magnam, omnia quas seque antiisqui dolorem quiatiis delluptatur auda dolupta menihillam, voloribus exeri utem ut hitiunt ibustia con pernatecabo. Lendit ad quibeatiunt faccuptus. Faceri qui dellaccum imuscipsa quam venda qui si dent dollectur ma qui nimilla sitatque moluptae poreicia quosamusapid que consequatia comnistium ipsa conse poribusam, ipsandi psandae lamus quias et faccuptiae ressunt dis doloreh enisciatur? Number Form: Mounting: Illumination:
45mm/1 3/4”h x 1/4” thk. dimensional Letters
CLARA DC1. Corridor Directional
Scale: 1:10
1850/6'-0 3/4"
Perpendicular corridor opening
Sign Placement Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
34
Clara Resort Scheme
DC ~ Corridor Directional
Esquema Clara Resort OPTIONAL
Ti con erunt utet dolores reiur, cum fugiatur?
457/18"
610/24"
2001 - 2005
Reception Recepción Royal Service
Restaurant Restaurantés YHI Spa & Wellness YHI Spa & Bienestar •
610/24"
•
Restaurant Restaurantés YHI Spa & Wellness YHI Spa & Bienestar •
610/18"
•
Reception Recepción Royal Service
895/35.25"
304/12"
2016 - 2021 Ice • Helio 2022 - 2040
Restrooms Aseos •
Main Pool Piscina Principal THE LEVEL
Laborpo reictur ehendia coressi si comnis molluption eatatio mos doloreperae pliquatis aligendis qui adipite nonem reic to ium, sus re et odis aliciiscim simus magnam, omnia quas seque antiisqui dolorem quiatiis delluptatur auda dolupta menihillam, voloribus exeri utem ut hitiunt ibustia con pernatecabo. Lendit ad quibeatiunt faccuptus. Faceri qui dellaccum imuscipsa quam venda qui si dent dollectur ma qui nimilla sitatque moluptae poreicia quosamusapid que consequatia comnistium ipsa conse poribusam, ipsandi psandae lamus quias et faccuptiae ressunt dis doloreh enisciatur? Number Form:
CLARA DC4. Corridor Directional
Mounting: Illumination:
CLARA DC3. Corridor Directional
CLARA DC2 Corridor Directional
Scale: 1:10
304/12"
Reception Recepción Royal Service
304/12"
•
Confrence Room 2 Sala de Conferenceia 2
2001 - 2005
Restaurant Restaurantés YHI Spa & Wellness YHI Spa & Bienestar •
Restrooms Aseos •
Restroom Aseos •
2016 - 2021
1650/65" Std. Height
CLARA DC5. Corridor Directional
Scale: 1:10
CLARA DC6. Corridor Directional
Sign Placement Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
35
Clara Resort Scheme
SS ~ Suspended Signs
Esquema Clara Resort OPTIONAL 861/34"
861/34"
221/8.75"
Reception Recepción •
CLARA IS1. Suspended ID, Single Line
OBSCURA DS1. Suspended Directional, Single Message
Main Pool Piscina Principal
CLARA IS1. Multiple Line 605/24"
157/6"
157/6"
605/24"
Reception Recepción
Beach • Playa
Main Pool Piscina Principal
Kid’s Pool Piscina para Niños
CLARA IS2. Typical Service ID
OBSCURA DS2. Single Message Only
445/17.5"
157/6"
445/17.5"
157/6"
Alternate Material Specification: Dibond
Shuttle Stop Parada del Autobús
Kid’s Pool Piscina para Niños
OBSCURA DS1. Multiple Message
Beach • Playa Pool • Piscina
Shuttle Stop Parada del Autobús CLARA IS3. Single Message Only
OBSCURA DS3. Single Message Only
317/12.5"
157/6"
157/6"
317/12.5"
OBSCURA DS4. Pictogram Only
Itat labo. Emolum voluptur sus natus is eaquia velibero descia nostem volliquam facessit eic tem qui sit occatusdae non placcup taquis vernat quam, nobit verciligent quibus as delit, quam endiam haribus aut od maiossum enimaio recerovid quisimagnam fugia as maioratem necti utemperro mos et reri reperum faci
2235/8’-0” Std. Height
221/8.75"
Reception Recepción
Beach • Playa
Aliata venis nus explacide vent dolenti usanis abor apiet dem faccatur, sin cupta volore odiorem quunt ut voluptaepro et facerio nserios parior aditemqui delibus sitas sant ea conseru mquiam ratibusam in pori dolorrum volut doluptati tem.
Scale: 1:10
Staff Only Soló Personal CLARA IS4. Single Message
Sign Placement Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
36
Clara Resort Scheme
IT ~ Transom ID
Esquema Clara Resort
IT ~ Transom ID
F PO
BY MELIÃ
IT1. Transome ID, The Level
IT2. Transome ID, Romance by Melia
F PO
BY MELIÃ
IT1. Placement, Transome ID, Royal Service Reversed
IT2. Placement, Transome ID, Romance by Melia
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
37
Clara Resort Scheme
IP ~ Projecting ID
Esquema Clara Resort
IP ~ Identificación de Proyección
157/6"
Aliata venis nus explacide vent dolenti usanis abor apiet dem faccatur, sin cupta volore odiorem quunt ut voluptaepro et facerio nserios parior aditemqui delibus sitas sant ea conseru mquiam ratibusam in pori dolorrum volut doluptati tem.
Typical
CLARA IP1. Projecting ID, Stair
Itat labo. Emolum voluptur sus natus is eaquia velibero descia nostem volliquam facessit eic tem qui sit occatusdae non placcup taquis vernat quam, nobit verciligent quibus as delit, quam endiam haribus aut od maiossum enimaio recerovid quisimagnam fugia as maioratem necti utemperro mos et reri reperum faci
Scale: 1:5
Alternate Material Specification: Dibond
CLARA IP2. Projecting ID, Elevator
100/4"
157/6 "
Typical
CLARA IP3. Projecting ID, Telephone
CLARA IP4. Projecting ID, Ice
Side Elevation
Typical Placement Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
38
PREFERRED
Clara Resort Scheme
IR ~ Room ID
Esquema Clara Resort
IR ~ Room ID
PREFERRED ADA
ECONOMY ADA
133 5 1/4"
221/8.75"
93/3 1/2"
231/9"
231/9"
LUGGAGE MALETAS Luggage
Luggage
CLARA IR. Room ID
CLARA IR. Room ID
LUGGAGE MALETAS
CLARA IR. Room ID
100/4"
LUGGAGE MALETAS Luggage
44/1 3/4"
100/4"
LUGGAGE MALETAS Luggage
1475/58"
1475/58"
1515/59 3/4"
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
39
IR ~ Room ID
Esquema Clara Resort
IR ~ Room ID
PREFERRED ADA
ECONOMY ADA
5 7/8"
7 1/4"
PREFERRED
Clara Resort Scheme
200/8"
CLARA IR. Room ID
Scale: 1:5
140/5 1/2"
93/3 1/2"
231/9"
STAFF ONLY SOLÓ PERSONAL
CLARA IR. Room ID
STAFF ONLY SOLÓ PERSONAL
CLARA IR. Room ID
100/4"
STAFF ONLY SOLÓ PERSONAL
44/1 3/4"
100/4"
STAFF ONLY SOLÓ PERSONAL
1475/58"
1475/58"
1515/59 3/4"
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
40
PREFERRED
Resort Obscura Scheme
IG ~ Guest Room Identification
Esquema Obscura Resort
IG ~ Guest Room Identification
ECONOMY ADA
Guest Room identification signs are used to designate room numbers in throughout the hotel.
133/5 1/4"
133/5 1/4"
1203
CLARA IG1. Guest Room Identification 70mm/2 3/4”h Plate Letters
CLARA IG2. Guest Room Identification ADA Alternate: Dibond
Scale: 1:3
Scale: 1:3
100/4" 100/4" 1203
1400/55"
1575/62"
Typical Placement Elevation
Typical Placement Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
41
Clara Resort Scheme
R ~ Restroom ID
Esquema Clara Resort
R ~ Identificación de Baño Destination identification signs are used throughout the Resort interiors to highlight specific service areas and communicate critical wayfinding information. Suspended destination identification signs are generally hung from the ceiling above the relevant service area. They can be single or double sided. Recommended sizing and layout for this sign type is as shown; however, appropriate scale, positioning and hanging distance should be handled on a site-by-site basis.
CLARA Scale: 1:5 RR4. Projecting ID, Restrooms, Assessible
Alternate Material Specification: Dibond
CLARA RW4.2. Projecting ID, Women
100/4"
CLARA RM4.1. Projecting ID, Men, Accessible
100/4"
Men
93/3 1/2"
MEN • HOMBRES
CLARA RW4.1. Projecting ID, Women, Accessible 1475/58"
CLARA RM4.2. Projecting ID, Men
Side Elevation
Typical Placement Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
42
PREFERRED
Clara Resort Scheme
R ~ Restroom ID
Esquema Clara Resort
R ~ Identificación de Baño
PREFERRED ADA
ECONOMY ADA
221/8.75"
231/9"
93/3 1/2"
231/9"
RESTROOMS • ASEOS
RESTROOMS ASEOS
Restrooms
CLARA RR1. Restroom ID
Scale: 1:4
CLARA RR1.1. Restroom ID, Accessible
CLARA RR3. Restroom ID, ADA
100/4"
RESTROOMS • ASEOS Restrooms
44/1 3/4"
100/4"
RESTROOMS ASEOS
1475/58"
1475/58"
1515/59 3/4"
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
43
Resort Clara Scheme Urban Scheme EsquemaResort Urbana Esquema Clara
Displays Dinรกmicos Dynamic Displays
Clara Resort Scheme
D ~ Dynamic Displays
Esquema Clara Resort
D ~ Dynamic Displays DM1. 40” Digital Display, Monolith Digital displays are to be used for information that requires frequent updates.
669/26 3/4"
400/15 3/4"
400/15 3/4"
574/22 1/2"
Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services. Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include room bookings, wayfinding, orientation, hotel activities, service advertising and multimedia . When do I use this sign? Monolith digital displays are to incorporate touch screen technology and interactive content. These may be placed at Reception areas or in the Main lobby.
161/6 1/4"
DM2. 32” Digital Display Monolith
605/23 3/4"
Digital displays are to be used for information that requires frequent updates.
161/6 1/4" Welcome to Paradisus Palma Real
June 20, 2015 ABC Corporation 10:00 am - 12:00 pm
Cygnus Group 12:30 pm - 4:00 pm
Dallas Stars 10:00 am - 5:00 pm
Grandview Heights 1:00 pm - 7:00 pm
Modulex 7:00 pm - 8:30 pm
Melia Corporate 10:00 am - 4:00 pm
Welcome to Paradisus Palma Real
Room 201
June 20, 2015 ABC Corporation
Room 201
10:00 am - 12:00 pm
Cygnus Group 12:30 pm - 4:00 pm
Room 103
Dallas Stars 10:00 am - 5:00 pm
Room 207
Grandview Heights 1:00 pm - 7:00 pm
Modulex
Room 106
7:00 pm - 8:30 pm
Melia Corporate
Room 105
10:00 am - 4:00 pm
XYZ Brand
Mr. Jones, please phone your...
DM1. 40” Digital Display Monolith, Elevation
Room 103
Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include room bookings, wayfinding, orientation, hotel activities, service advertising and multimedia .
Room 207
When do I use this sign?
Room 201
Room 201
Room 106
Room 105
Monolith digital displays are to incorporate touch screen technology and interactive content. These may be placed at Reception areas or in the Main lobby.
Room 202
1821/71 3/4"
1949/76 3/4"
9:00 am - 10:00 am
Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services.
DM2. 32” Digital Display Monolith, Elevation
A
40” Ariadne Digital Display Monolith Front panels with direct print Clara finish. Touch screen display with integrated multimedia controller 352686
B
Antispill, mighty glass display
A
32” Ariadne Digital Display Monolith Front panels with direct print Clara finish. Touch screen display with integrated multimedia controller 352684
B
Antispill, mighty glass display
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
45
Clara Resort Scheme
D ~ Dynamic Displays
Esquema Clara Resort
D ~ Dynamic Displays DP1. 40” Digital Display, Portrait
Wall mount displays may be touchscreen and interactive or conventional screens.
X
X
Wall mount digital diplays may be used inReception areas, VIP lounges, shuttle stops or other key touchpoints. Content may include guest welcome, room bookings, wayfinding, orientation, hotel activities, service advertising and multimedia .
X = 56/2 1/4” w/ Touch X = 44/1 3/4” w/o Touch
Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services.
X = 56/2 1/4” w/ Touch X = 44/1 3/4” w/o Touch
Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include orientation, direction, guest welcome, service advertising, event listings and multimedia. Signs should be inset & mounted flush with wall surface wherever possible. 490/19 1/4"
595/23 1/2"
DP2. 32” Digital Display, Portrait Wall mount digital diplays may be used inReception areas, VIP lounges, shuttle stops or other key touchpoints. Content may include guest welcome, room bookings, wayfinding, orientation, hotel activities, service advertising and multimedia .
LOS EVENTOS DE HOY TODAY’S EVENTS
LOS EVENTOS DE HOY TODAY’S EVENTS
Sunday July 3, 2015
Sunday July 3, 2015
Salsa Lessons Activity Pool 11 am
South Beach Area 3 pm
Kids Volleyball
Great Room 10 pm
Make a reservation for dinner tonight. Aqua yoga at the Main Pool 7:30...
DP1. 40” Digital Display Portait - Wall Mounted, Elevation
Great Room 10 pm
2040/80 1/4"
Karaoke Contest
Karaoke Contest
1175/46 1/4"
South Beach Area 3 pm
Make a reservation for dinner tonight. Aqua yoga at the Main Pool 7:30...
Wall mount displays may be touchscreen and interactive or conventional screens.
Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services.
2040/80 1/4"
Kids Volleyball
Activity Pool 11 am
989/39 1/4"
Salsa Lessons
Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include orientation, direction, guest welcome, service advertising, event listings and multimedia. Signs should be inset & mounted flush with wall surface wherever possible.
A
Ariadne Digital Wall Mount Display with integrated multimedia controller
B
3 mm aluminum header panel with direct print Clara finish. Vinyl or direct print graphics
C
Antispill, mighty glass display
DP2. 32” Digital Display Portait - Wall Mounted, Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
46
Clara Resort Scheme
D ~ Dynamic Displays
Esquema Clara Resort
D ~ Dynamic Displays DL1. 40” Digital Display, Landscape
Wall mount digital diplays may be used in Reception areas, VIP lounges, shuttle stops or other key touchpoints. Content may include guest welcome, room bookings, wayfinding, orientation, hotel activities, service advertising and multimedia . X
Wall mount displays may be touchscreen and interactive or conventional screens.
X = 56/2 1/4” w/ Touch X = 44/1 3/4” w/o Touch
Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services. Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include orientation, direction, guest welcome, service advertising, event listings and multimedia. Signs should be inset & mounted flush with wall surface wherever possible.
792/31 1/4"
X = 56/2 1/4” w/ Touch X = 44/1 3/4” w/o Touch
979/38 1/2"
793/31 1/4"
DL2. 32” Digital Display, Landscape
Activity Pool 11 am
Kids Volleyball
792/31 1/4"
Salsa Lessons
Salsa Lessons Activity Pool 11 am
Kids Volleyball South Beach Area 3 pm
642(?)/25 1/4"
Sunday July 3, 2015
Sunday July 3, 2015
Wall mount digital diplays may be used in Reception areas, VIP lounges, shuttle stops or other key touchpoints. Content may include guest welcome, room bookings, wayfinding, orientation, hotel activities, service advertising and multimedia . Wall mount displays may be touchscreen and interactive or conventional screens.
Karaoke Contest
South Beach Area 3 pm
Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services.
Great Room 10 pm
Karaoke Contest
DL1. 40” Digital Display Portait - Wall Mounted, Elevation
2040/80 1/4"
2040/80 1/4"
Great Room 10 pm
Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include orientation, direction, guest welcome, service advertising, event listings and multimedia. Signs should be inset & mounted flush with wall surface wherever possible.
A
Ariadne Digital Wall Mount Display with integrated multimedia controller
B
3 mm aluminum header panel with direct print Clara finish. Vinyl or direct print graphics
C
Antispill, mighty glass display
DL2. 32” Digital Display Portait - Wall Mounted, Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
47
Clara Resort Scheme
D ~ Dynamic Displays
Esquema Clara Resort
D ~ Dynamic Displays DD1. 15” Digital Display @ Door Digital room identification signs are to be used in Convention Centers, meeting rooms, and banquet rooms where information is changed regularily. They may also be used at the Resort’s discretion outside restaurant entries.
31/1 1/4"
31/1 1/4"
430/17" 332/13"
Displays are not touch screen or interactive.
Meeting Room 1
Meeting Room 1
# 10 23
316/12 1/2"
414/16 1/2"
# 10 23
10:00 am - 12:00 pm
ABC Corporation
10:00 am - 12:00 pm
ABC Corporation Marketing Strategies for the Upcoming Year Hosted by: Jane Krowski
Marketing Strategies for the Upcoming Year
Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services. Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include room bookings, RSS feeds . Signs should be inset & mounted flush with wall surface wherever possible.
Hosted by: Jane Krowski
DD2. 10” Digital Display @ Door
12:00 am - 4:00 pm Cygnus Group
Digital room identification signs are to be used in Convention Centers, meeting rooms, and banquet rooms where information is changed regularily. They may also be used at the Resort’s discretion outside restaurant entries. Displays are not touch screen or interactive. Signs must be installed with power and data as per manufacturers specifications. Interface with hotel booking systems and networks must be approved by Meliã Information Services. Content is shown for illustration purposes only and should meet all Meliã branding guidelines. Content may include room bookings, RSS feeds .
73/3"
Meeting Room 1 # 10 23
73/3"
Signs should be inset & mounted flush with wall surface wherever possible.
Meeting Room 1
ABC Corporation
# 10 23
Marketing Strategies for the Upcoming Year Hosted by: Jane Krowski
10:00 am - 12:00 pm
10:00 am - 12:00 pm
ABC Corporation Marketing Strategies for the Upcoming Year
12:00 am - 4:00 pm Cygnus Group
Hosted by: Jane Krowski
DD1. 15” Digital Display @ Door - Wall Mounted, Elevation
1525/60"
1525/60"
12:00 am - 4:00 pm Cygnus Group
A
Ariadne Digital Wall Mount Display with integrated multimedia controller
B
3 mm aluminum header panel with direct print Clara finish. Vinyl or direct print graphics
C
Antispill, mighty glass display
DD2. 10” Digital Display @ Door - Wall Mounted, Elevation
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
48
Modulex Construction Drawings Documentos de Construcciรณn Modulex
Construction Documents
Dibond
Documentos de Construcción
Surface The final result is a very nice mat surface ranging from just a background color and text to an allcovering photo. The edge of the panels appears elegantly with the black core as the dominating expression. Basic Steel Modulex Basic Steel is more expensive than Modulex Basic Bond. First of all, the price of the plate is higher because it has been given a polished stainless steel look on the one side. Furthermore, the direction of polishing has to be taken into account when nesting the plates to prevent the panels from turning 90° to minimize waste. Finally, the POP process is significantly slower as the panels always need a printed white layer under the ordered graphics or text. Logistics ATTENTION! For both products it is recommended that the graphics for each single panel is created separately by use of the templates that you can find in Modulex Product Handbook. If this is not the case and we receive an AI file with a number of panels in one file it is MANDATORY that you use the template as base for each panel. At least each panel needs the panel shape and actual panel size from the template placed in the correct layer. It is not possible to order other texting technics as foil for these products and layers in the AI file for these technics will be ignored. If no AI files are delivered with the order it will not be released into production.
Basic Bond and Basic Steel w08 / 2013
Content:
General Information
General information
1
Standard features and options
2
Schematic process
3
Assortment
4
Maintenance
5
As a natural consequence of the development within the POP technologies, Modulex is now introducing a new interior sign assortment called Basic Bond and Basic Steel. The assortment is based on very basic sign products characterized mainly by text and graphics. The material used is 3 mm sandwich plates and a separate production flow. The assortment is supplementing the existing Modulex assortment very well and is well suited for projects with cut-throat pricing. Material and process The panels are made from 3 mm thick sandwich plates with a PE-core (polyethylene) and a covering layer of 0.3 mm aluminum. Modulex Basic Bond is painted on both sides with a white polyester paint and subsequently by means of the POP technology covered with the specified color, graphics and text. The print process is very rational: The panels are placed digitally on a full plate (1250 x 2500) and then printed. This allows the most optimal printing speed and the lowest possible price. To make it possible to deliver a single panel or a just a few panels for a given order, more orders are keyed into the system after which the software automatically places the panels on the plate ensuring as little waste as possible. This process is called “nesting”. Each individual panel is now cut out of the big plate. Finally, the panels are sorted, packed with the mounting tape and shipped.
Limitations The POP technology is continuously developing; there is, however, still a negligible risk that two identical panels produced at different times may vary in color tones. Normally, this will only be visible if the two panels are placed very close to each other. A claim will only be allowed in case of a strikingly visible difference in for instance a background color on panels delivered in the same delivery. Very small tolerances are incorporated in the process and we therefore recommend omitting graphic elements along the edges of the panels to avoid small displacements of the print compared to the panel.
Standard features and options Warranty:
The supplementation guarantee applies to all articles that are produced, marketed and delivered by Modulex. Within 10 years of delivery by Modulex of products for a main or first order, Modulex guarantees to be able to make supplementary deliveries of products with a similar functionality and design (shape, color, typography and graphics) as delivered under the main order, unless otherwise specifically stated in Modulex’ offer or order confirmation. As for digital products, the guaranteed supplementary period is only three years following delivery of main order by Modulex. As for third party products, Modulex grants the same supplementary guarantee as the producer.
Typical use:
Panels: (polyethylene) with a covering layer of 0.3 mm aluminum Panel finish:
Print on Panel (Steel) Graphical method:
Installation method:
Size specification Throughout this document measurements will be given in both millimeters and inches. The metric measurements are exact whereas the English standard is calculated and therefore shown in brackets: 25.4 [1.0]
1
2
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
50
Construction Documents
Concrete Foundations
Documentos de Construcción
Cimientos de Hormigón
Compass - Dimensioning & Concrete Foundation
Dimensioning:
In connection with dimensioning of Compass exterior post and panel signs there are several factors to be considered. First of all the type of leg as well as installation method (ground sleeve or concrete) must be decided and the wind load conditions should be taken into consideration. In general a strong leg allows a large sign. A concrete foundation instead of a ground sleeve has the same effect. Finally, there is the wind load. A climate with gentle winds makes it possible to create larger sign surfaces, just as locations under shelter or near vegetation give increased opportunities.
= sign width 500 mm).
The chapter Installation contains a document, which describes the wind load issue in details in relation to Compass as well as Pacific Exterior. The document describes how to determine the actual wind load category.
The chapter Wind Load includes all information about dimensioning of Compass post and panel signs. A chart has been prepared for each of the 9 different wind load categories (A1 - C3). Each chart shows the fixed maximum total panel sizes in combination with various legs and installation methods. The chapter comprises post and panel signs with 2 and 3 legs.
In connection with post and panel signs on 1 leg only, i.e. projecting signs on leg, centre panels on leg or a leg with a combination of projecting and centre panels, the wind load is not important. The below calculations of maximum sign sizes can thus be used under all conditions.
The below table shows L and B in relation to concrete foundation when 3 legs in Ø=90 mm are used: MODULE 500 = sign width 500 mm x 2 sections). Foundation size (measured in mm) Module 500 mm
Centre and projecting panels:
Projecting panels: Ground sleeve can be used if the sign panel area does not exceed 4000 cm2 (max. 5 panels). Centre panels: Ground sleeve can be used if the sign panel area does not exceed 4800 cm2.
If concrete foundation is used in accordance with the below drawing, the sign panel area can be increased accordingly. The drawing shows the dimensions.
Foundation size (measured in mm) Module 800 mm
Module 1000 mm
Module 500 mm
Module 1250 mm
L
B
L
B
L
B
L
B
Ø70/60x60
1000
950
1000
1250
900
1450
900
1700
Ø90/ID 175
1000
1250
1000
1550
1000
1750
900
2000
ID 250 1
1100
1275
1100
1575
1100
1775
1100
2025
Foundation size (measured in mm)
ID 250 2
1700
1340
1750
1640
1700
1840
1600
2090
Module 1600 mm
ID 250 3
-
-
1800
1640
1900
1840
1900
2090
Ø90/3 pcs
Ø90/3 pcs
Module 800 mm
Module 1000 mm
Module 1250 mm
L
B
L
B
L
B
L
1100
1680
1000
2275
900
2680
900
Module 2000 mm
Module 3000 mm
B 3180
Module 4000 mm
L
B
L
B
L
B
L
800
3880
800
4680
700
6680
600
B 8680
Foundation size (measured in mm) Module 1600 mm Module 2000 mm
Module 3000 mm
Module 4000 mm
L
B
L
B
L
B
L
B
Ø70/60x60
800
2050
800
2450
700
3450
600
4450
Ø90/ID 175
900
2350
800
2750
800
3750
700
4750
ID 250 1
1100
2375
1200
2775
1100
3775
1000
4775
ID 250 2
1500
2440
1400
2840
1300
3840
1200
4840
ID 250 3
1900
2440
2000
2840
1700
3840
1500
4840
Sign constructions (only Ø=90 mm) with 3 legs:
Use of chemical bolts in foundation after delivery of sign:
All Compass post and panel signs can be fitted with chemical bolts. The concrete foot is used as template for drilling of holes.
Casting of bolts in foundation prior to delivery of sign:
In the chapter "Part Drawings" you will find detailed information about the placing of holes in the various concrete feet so that the bolts can be placed correctly in the foundation. The below drawing is used when the distance between the legs are calculated. The chart shows the distance from centre of leg to panel. The distance from leg to leg is calculated by means of the following formula: Panel width (both standard and XY) + distance from centre of the leg to panel for both legs (may be different). Example: Module width 1600 mm + 56 mm + 56 mm (for Ø=90 mm) = 1712 mm.
Concrete foundation: In most cases the concrete foundation described in the below chart will be sufficient, but it must be underlined that the chart is only meant as a guide, and that Modulex cannot be held responsible for conditions in relation to concrete foundations. Local conditions should always be thoroughly evaluated.
Post and panel signs with 2 legs:
The drawing illustrates that the height of the foundation is always 1000 mm. L=length and B=width is variable in relation to the chosen leg (strong legs allow large signs) and the sign width. L & B appear from the below chart (MODULE 500
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
51
Compass - Post & Panel Sign Post and panel (25 mm) signs can be composed by several elements: There are 5 different posts, see survey. The posts can be mounted in ground sleeves or on concrete foot. The chosen example is a plane panel mounted on a 70 mm post. 25 mm plane panels are available in front interchangeable version. It is important to avoid overload. Please see survey of post heights / maximum sign area.
Construction Documents
Post & Panel, Flag Signs
Documentos de Construcción
Post & Panel, Flag Signs
Compass - Flag Sign - Mounting & Assembly Mounting Option A
Assembly
Material: All parts are made of aluminium. Assembling unit is stainless steel. Surface Treatment: All visible parts are painted with oven-hardening polyester paint. Standard Colours: MODULEX standard colours. The colour of the aluminium end clips follows the panel colour. Assortment: 100 and 120 mm high panels. See Order List. Only for Ø=70 mm post without tracks. Mounting Option A: Mounting Option B: Comments: End clips are flat. Please order panel and mounting unit. Assembling unit is meant for vertical alignment of panels. Please order separated
Material:
Surface Treatment:
Standard Colours:
Panels and posts are made of aluminium. Top cover for post is injection moulded Pocan. Ground sleeves are made of steel. All aluminium parts are painted with oven-hardening polyester paint. The ground sleeve is galvanised and the coupling profile is anodised. Panels are available in MODULEX standard colours. Coupling profile is black.
Assortment:
See Order List.
Comments:
Post and panel signs with Ø=70 mm posts can be fitted with bridging tube. It is possible to fit a light cap on all posts.
MELIÃ Sign Manual / MELIÃ Manual de Señalización I 2015.10.09
52
To place and order, please contact Modulex Americas Inc. 1001 Brickell Bay Drive, 27th Floor, Suite 2704 Miami, FL 33131 USA p. 1.305.503.7737 info@modulexgroup.com www.modulexgroup.com
Prepared by:
Part of the Modulex Group of Companies These drawings involve confidential proprietary rights of Modulex Americas Inc. (o/a Brand On) and all design, manufacturing, reproductions, use and sale rights regarding the same are expressly reserved. These drawings are submitted under a confidential relationship for a specified purpose and the recipient by accepting this document assumes custody and agrees (a) that this document will not be copied or reproduced in whole or in part, not it’s contents revealed in any manner or to any person except to meet the purpose for which it was delivered and (b) that any special features peculiar to this design will not be incorporated into other projects.