Power Ele
Power Electrics Parts Brochure
Generating Excellence The largest independent in the UK, offering a nationwide service.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Contents:
Power Electrics Parts
Insulated Gender Converter Connectors
3
Insulated G Style Clamp
with Double Cable Connection
4
with Short Extension Arm
5
with Right Angled Extension Arm
6
with Long Extension Arm
7
Insulated Horizontal Clamp
with Short Extension Arm
8
with Right Angled Extension Arm
9
with Long Extension Arm
10
Insulated Underground Cable Connector
11
JP Fuse Carrier with Integral Generator Input Connector
12
JS Fuse Carrier with Integral Generator Input Connector
13
Insulated Overhead Line Clamp with Generator Connector
14
Powerline Singe Pole Connectors
Panel Inlet
15
Panel Socket
16
Cable Plug
17
Cable Connector
18
Rotary Clamp
19
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Insulated Gender Converter Connectors When confronted with unexpected or incorrect hook-up situations, these Double ended connectors allow conversion from Male to Female or Female to Male Powerline connections on existing Chassis or Cable mounts. The “GEC-MF” unit is supplied with 2 x “CCF” style 750 Amp connectors to convert from an existing Male Insulator to the required Female. The “GEC-FM” unit is supplied with 2 x “CPF” style 750 Amp connectors to convert from an existing Female Insulator to the required Male. All connectors are IP2X when unmated and sealed to IP68 when mated. Available in positions Earth, Neutral, Line 1, Line 2 and Line 3.
Item
Part Number
Male to Female Earth Converter
GEC-MF-E-*-T7
Male to Female Neutral Converter
GEC-MF-N-*-T7
Male to Female L1 Converter
GEC-MF-L1-*-T7
Male to Female L2 Converter
GEC-MF-L2-*-T7
Male to Female L3 Converter
GEC-MF-L3-*-T7
Item
Part Number
Female to Male Earth Converter
GEC-FM-E-*-T7
Female to Male Neutral Converter
GEC-FM-N-*-T7
Female to Male L1 Converter
GEC-FM-L1-*-T7
Female to Male L2 Converter
GEC-FM-L2-*-T7
Female to Male L3 Converter
GEC-FM-L3-*-T7
* Add the following codes to identify connector colour: GN = Green GY = Grey BU = Blue WH - White BR = Brown RD = Red
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
3
Insulation G Style Clamp with Double Cable Connection
45 cm
The insulation G style clamp allows for direct connection of a generator cable to a live LV bus-bar. The clamp is completely insulated in order to meet the requirements of E.S.I.26-3 for live line working. The clamp is fixed to the bus-bar by means of an insulated box spanner. 2 powerlock type generator input or output connection points are incorporated within the clamp to allow for direct connection of the generator cable end. These devices are rated at 1200A. The clamps are also keyed to distinguish between phases and prevent connection errors.
4
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Insulated G Style Clamp with Short Extension Arm
LVB200S The insulated G style clamp allows for direct connection of a generator cable to a line LV bus-bar. The clamp is completely insulated in order to meet the requirements of E.S.I 26-3 for live line working. The clamp is fixed to the bus-bar by means of an insulated box spanner. A powerlock type generator input connection point is incorporated within the clamp to allow for direct connection of the generator cable end. These devices are rated at 600A continuous. The clamps are also keyed to distinguish between phases and prevent connection errors. Typical application would be to connect a generator to the live feeder cabinet prior to synchronization.
24cm Approx.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
5
Insulation G Style Clamp with Right Angled Extension Arm
LVB200R
13cm Approx.
The insulated G style clamp allows for direct connection of a generator cable to a line LV bus-bar. The clamp is completely insulated in order to meet the requirements of E.S.I 26-3 for live line working. The clamp is fixed to the bus-bar by means of an insulated box spanner. A powerlock type generator input connection point is incorporated within the clamp to allow for direct connection of the generator cable end. These devices are rated at 600A continuous. The clamps are also keyed to distinguish between phases and prevent connection errors. Typical application would be to connect a generator to the live feeder cabinet prior to synchronization.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Insulated G Style Clamp with Long Extension Arm
LVB200L The insulated G style clamp allows for direct connection of a generator cable to a line LV bus-bar. The clamp is completely insulated in order to meet the requirements of E.S.I 26-3 for live line working. The clamp is fixed to the bus-bar by means of an insulated box spanner. A powerlock type generator input connection point is incorporated within the clamp to allow for direct connection of the generator cable end. These devices are rated at 600A continuous. The clamps are also keyed to distinguish between phases and prevent connection errors. Typical application would be to connect a generator to the live feeder cabinet prior to synchronization.
40cm Approx.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
7
Insulated Horizontal Clamp with Short Extension Arm
LVK600S The insulated G style clamp allows for direct connection of a generator cable to a line LV bus-bar. The clamp is completely insulated in order to meet the requirements of E.S.I 26-3 for live line working. The clamp is fixed to the bus-bar by means of a hexagonal arm. A powerlock type generator input connection point is incorporated within the clamp to allow for direct connection of the generator cable end. These devices are rated at 600A continuous. The clamps are also keyed to distinguish between phases and prevent connection errors. Typical application would be to connect a generator to the live feeder cabinet prior to synchronization.
28.5cm Approx.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Insulated Horizontal Clamp with Right Angled Extension Arm
LVK600S
The insulated Horizontal clamp allows for direct connection of a generator cable to a live LV bus-bar. The clamp is completely insulated in order to meet the requirements of E.S.I 26-3 for live LV bus-bar. The clamp is fixed to the bus-bar by means of a hexagonal arm. A powerlock type generator input connection point is incorporated within the clamp to allow for direct connection of the generator cable end. These devices are rated at 600A continuous. The clamps are also keyed to distinguish between phases and prevent connection errors. Typical application would be to connect a generator to the live feeder cabinet prior to synchronization.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
9
Insulated Horizontal Clamp with Long Extension Arm
LVK600L The insulated Horizontal clamp allows for direct connection of a generator cable to a live LV bus-bar. The clamp is completely insulated in order to meet the requirements of E.S.I 26-3 for live LV bus-bar. The clamp is fixed to the bus-bar by means of a hexagonal arm. A powerlock type generator input connection point is incorporated within the clamp to allow for direct connection of the generator cable end. These devices are rated at 600A continuous. The clamps are also keyed to distinguish between phases and prevent connection errors. Typical application would be to connect a generator to the live feeder cabinet prior to synchronization.
44cm Approx
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Insulated Underground Cable Generator Connector This compact unit incorporates a Powerlock generator input connection point with a rear termination area to accept solid alloy cable cores. The unit is completely insulated in order to meet the requirements of E.S.I. 26-3 for live line working. This enables a temporary mobile generator to be connected to an underground cable when repair work is undertaken. The cable is excavated, cut and the Powerlock connector then fitted to the cable cores via 2 set screws. The generator cable end can then directly linked into the underground cable. After completion of the repair, the Powerlock fittings are simply removed and the main cable spliced using existing methods.
Desciption
Part Code
Insulated Underground Cable Generator Connector, Neutral Key Position/Black
LVJ900-N-BK
Insulated Underground Cable Generator Connector, Line 1 Key Position/Red
LVJ900-1-R
Insulated Underground Cable Generator Connector, Line 2 Key Position/Yellow
LVJ900-2-Y
Insulated Underground Cable Generator Connector, Line 3 Key Position/Blue
LVJ900-3-BL
Insulated Ratchet Tightening Tool
LVJ900H
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
11
JP Fuse Carrier with Integral Generator Input Connector
LVD401 The JP (3 1/4) fuse carrier provides a safe and efficient means of connecting a mobile generator supply cable to fully shrouded or on shrouded distribution boards. The unit complies with the requirements of EATS 37.2. The generator cable (when fitted with a Powerlock type Line Drain cable coupler) can be plugged directly into the Fuse Carrier and used to feed either the LV Bus-bar or Feeder circuit.
The fuse generator connector is finger proof to avoid accidental touching of live elements. The input connectors are colour coded and mechanically keyed to prevent connection errors; Line 1 units will only accept Line 1 generator connectors. The unit accepts standards BS88-5 fuses (not supplied) The integral generator connector also accepts generator connectors with the secondary locking device which eliminates the potential of accidental disconnection under load conditions. Because this unit is a direct replacement for the existing standard JW3ST fuse unit, it offers a safe, fast and cost effective method of upgrading existing distribution boards to have generator input points. It is not necessary to make any modifications to the cabinet other than remove an existing fuse way and replace with this unit.
12
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
JS Fuse Carrier with Integral Generator Input Connector
LVD400 The JP (3 5/8) fuse carrier provides a safe and efficient means of connecting a mobile generator supply cable to fully shrouded or on shrouded distribution boards. The unit complies with the requirements of EATS 37.2. The generator cable (when fitted with a Powerlock type Line Drain cable coupler) can be plugged directly into the Fuse Carrier and used to feed either the LV Bus-bar or Feeder circuit. The fuse generator connector is finger proof to avoid accidental touching of live elements. The input connectors are colour coded and mechanically keyed to prevent connection errors; Line 1 units will only accept Line 1 generator connectors. The unit accepts standards BS88-5 fuses (not supplied). The integral generator connector also accepts generator connectors with the secondary locking device which eliminates the potential of accidental disconnection under load conditions. Because this unit is a direct replacement for the existing standard JW4ST fuse unit, it offers a safe, fast and cost effective method of upgrading existing distribution boards to have generator input points. It is not necessary to make any modifications to the cabinet other than remove an existing fuse way and replace with this unit.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
13
Insulated Overhead Line Clamp with Generator Connector
LVF600 The Overhead Line Clamp allows for direct connection of a generator unit to LV overhead line systems. The unit consists of an insulated Line Clamp, 3 metres of 50mm2 flexible copper cable and a powerlock type generator input cable.
The generator connection point offers all standard safety features associated with powerlock type connectors, such as keys to distinguish phases, IP67 sealing and individual phase colour coding.
The Insulated Overhead Line Clamp is also available in a boxed set.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Powerline Single Pole Connectors Panel Inlet - “PIF” These are Panel Inlet connectors. As both the Panel Inlet and Cable Connectors and IP2X Protected, this ensures safety where two loads or supplies are present. For example where both the Temporary Generator and Electricity Network are potentially Live during Synchronisation. They are Finger Protected in the un-mated condition to meet the requirements of IP2X thereby protecting the user from accidental contact with any Live metal. Panel Inlets can be either Front or Rear Mounted on equipment whilst maintaining EN/ESI creepage and clearance requirements and are supplied in either T4 (400Amp) or T7 (750Amp) versions. The “PIF” Connector incorporates a Spring Loaded Locking Pin that engages with the slot on the mating Cable Connectors (CCF). Once mated, the connectors can only be separated by using an unlocking key. Panel Inlet connectors are supplied with pre-installed contacts.
These are Panel Inlet connectors. As both the Panel Inlet and Cable Connectors are IP2X Protected, this ensures safety where two loads or supplies are present. For example where both the Temporary Generator and Electricity Network are www.powerelectrics.com potentially Synchronisation. T. +44 (0)370 850 0858 | F. Live +44during (0)370 850 0851 | E. Parts@powerelectrics.com
15
Powerline Single Pole Connectors Panel Socket - “PSF”
Panel Sockets are typically used as the Live or Supply side of the circuit. They are Panel Sockets areFinger typically used as or Supply sidetoofmeet the circuit. They are Finger Protected in the the Live un-mated condition the requirements of IP2XProtected thereby in the un-mated condition to meet the requirements of IP2X thereby protecting the user from accidental protecting the user from accidental contact with to any Live elements. contact with any Live elements. Panel Sockets can either be Front or Rear Mounted on equipment whilst maintaining EN?ESI creepage and clearance requirements and are supplied in either T4 (400Amp) or T7 (750Amp) versions. Panel Sockets can be either Front or Rear Mounted on equipment whilst maintaining EN/ESI creepage anda clearance supplied in either T4 (400Amp) The “PSF” Connector incorporates slot that requirements engages withand theareSpring Loaded Locking Pin on the T7 (750Amp) versions. mating Cable Plugor(CPF) connector. Once mated, the connectors can only be separated by using an unlocking key. Panel Socket connectors are supplied with pre-installed contacts. The “PSF” Connector incorporates a slot that engages with the Spring Loaded Locking Pin on the mating Cable Plug (CPF) connector.
Once mated, the connectors can only be separated by using an unlocking key.
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Powerline Single Pole Connectors Cable Plug - “CPF” These are Cable Plug connectors. As both the Cable Connector and Cable Plugs are IP2X Protected, this ensures safety where two loads or supplies are present. For example where both the Temporary Generator and Electricity Network are potentially Live during Synchronisation. They are Finger Protected in the un-mated condition to meet the requirements of IP2X thereby protecting the user from accidental contact with any Live elements. Cable Plug Connectors are available with either: + Set Screw termination for cable sizes from 25mm2 up to 120mm2 or + Crimp Termination for cables up to 300m2. The “CPF” Connector incorporates a Spring Loaded Locking Pin that engages with the slot on both the mating Panel Socket and Cable Connectors. Once mated, the connectors can only be separated by using an unlocking key. A plastic watertight strain relief cable gland is supplied as standard to provide IP68 sealing of the cable sheath to the connector.
These are Cable Plug connectors. As both the Cable Connector and Cable Plugs are IP2X Protected, this ensures safety where two loads or supplies are present. For example where both the Temporary Generator and Electricity Network are potentially Live during Synchronisation. www.powerelectrics.com
T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
17
Powerline Single Pole Connectors Cable Connector - “CCF”
Cable Connectors areused typically as the or Supply of the circuit. They Cable Connectors are typically as used the Live orLive Supply side side of the circuit. They areare Finger Protected in theFinger un-mated condition meet the requirements IP2X thereby protecting the user from Protected in thetoun-mated condition to meetofthe requirements of IP2X thereby accidental contact with any Live elements. protecting the user from accidental contact with any Live elements. Cable Connectors are available with either:
+ SetCable Screw termination cable with sizeseither: from 25mm2 up to 120mm2 Connectors arefor available or + Crimp Termination fortermination cables up for to 300mm2. Set Screw cable sizes from 25mm² up to 120mm² or Crimp Termination for cables up to 300mm². The “CCF” Connector incorporates a slot that engages with the Spring Loaded Locking Pin on both the mating PanelThe Inlet andConnector Cable Plug connectors. Once mated, thewith connectors only Locking be separated by “CCF” incorporates a slot that engages the Springcan Loaded using an inlocking key. Pin on both the mating Panel Inlet and Cable Plug connectors. A plastic watertight strainthe relief cable gland in be supplied as by standard provide key. IP68 sealing of the Once mated, connectors can only separated using antounlocking cable sheath to the connector.
A plastic watertight strain relief cable gland is supplied as standard to provide IP68
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
Rotary Clamp
Compact unit incorporates a Line Source Finger Proof connector with a rotary type clamp, suitable for use on slotted Bus-bars. The handle meets the requirements of IEC 60900 (live working, hand tools for use up to 1000Vac and 1500Vdc. The clamp is manufactured in high conductivity material and is suitable for 660A continuous operation. The rotary wheel is manufactured from hardened steel which eliminates problems associated with hole elongation. An ergonomic fully insulated installation tool is available for fixing the clamp to a slotted bus-bar.
Line / Colour
Description Code
Earth / Green Neutral / Blue Line 1 / Brown Line 2 / Black Line 3 / Grey Installation Tool
LVE500-E-GN LVE500-N-BL LVE500-1-BN LVE500-2-BK LVE500-3-GY LVE500H
www.powerelectrics.com T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com
19
GENERATING EXCELLENCE t HIRE: Power Electrics provide you with the complete power package, all backed up with 24/7 support. We provide the fully turnkey generator solution. GENERATINGt SALES: EXCELLENCE
GENERATING EXCELLENCE t HIRE: Power Electrics provide you with the t SERVICE: Ourcomplete detail topower service is second to none. All service package, all backed up withengineers 24/7 support. are highly skilled and fully conversant with all
t HIRE: Power Electrics provide you with the complete power aspects of diesel power Generation. package, all backed up with 24/7 support.
t SALES: We provide the fully turnkey generator solution.
t PARTS: Power Electrics Parts Department carries a full range t SALES: We provide the fully turnkey generator solution. of spares and Generator ancillary product lines.
t SERVICE: Our detail to service is second to none. All service engineers are highly skilled and fully conversant with all
aspects of diesel powertGeneration. SERVICE: Our detail to service is second to none. All service
t USED SALES: We offer a variety of pre-owned generators engineers are highly skilled and fully conversant with all manufactured by the biggest brands in Power Generation. of diesel power t PARTS: Power Electrics Partsaspects Department carries a full Generation. range of spares and Generator ancillary product lines.
t PARTS: Power Electrics Parts Department carries a full range
t USED SALES: We offer a variety of pre-owned generators of spares and Generator ancillary product lines. manufactured by the biggest brands in Power Generation.
t USED SALES: We offer a variety of pre-owned generators manufactured by the biggest brands in Power Generation.
Power Electrics (Bristol) Ltd, Head Office, St. Ivel Way, Warmley, Bristol, BS30 8TY
Power Electrics (Bristol) Ltd, Head Office,
St. Ivel Way, Warmley, Bristol, BS30 8TY0858 | F. 0370 850 0851 T. 0370 850
E. enquiries@powerelectrics.com
T. 0370 850 0858 | F. 0370 850 0851
www.powerelectrics.com PowerE. Electrics enquiries@powerelectrics.com
ectrics
www.powerelectrics.com
Power Electrics is a registered dealer for FG Wilson.
Power Electrics is a registered dealer for FG Wilson.
Power Electrics (Bristol) Ltd, Head Office, St. Ivel Way, Warmley, Bristol, BS30 8TY
www.powerelectrics.com T. 0370 850 0858 | F. 0370 850 0851 T. +44 (0)370 850 0858 | F. +44 (0)370 850 0851 | E. Parts@powerelectrics.com Power Electrics is a registered E. enquiries@powerelectrics.com dealer for FG Wilson.