Användning- och underhållsguide.

Page 32

ENGLISH Dry Heater* - MO27 Lack of water in the heater. Every function of the pool is disabled. After solving the problem, turn off and turn on the power again for initialize the water heating procedure. Refer to the “water related problems at flusso” section below.

HTR

DRY

---Figure 34: Message MO27

Overheated heater (OHH)* - MO30

when the water temperature is below 42.2 °C (108 °F). Refer to “Water

Water temperature sensors have detected too many temperatures high, Problems at flusso” below. 47.8 °C (118 °F). All pool functions are disabled. Press any button on the control panel to reset the heater operation

HTR

TOO

HOT

---Figure 35: Message MO30

A restore message may accompany other messages: Some errors may require the power to be cut and then restored.

PRE5

BTTN

TO

R5ET

---Figure 36: Reset message

SENSOR ALARMS MESSAGES Incorrect sensor calibration - MO15: The sensors connected to the temperature measurement may be out of calibration by 3° F. Call technical service.

5N5R

BAL-

ANCE Figure 37: Message MO15

Incorrect sensor calibration* - MO26: The sensors connected to the water temperature measurement ARE out of sync. There is a fault Incorrect calibration of the sensors for at least 1 hour. Call technical service.

5N5R

5YNC

----

CALL -32-

FOR

5RVC

---Figure 38: Messaggio MO26