As technology advances, The amount of data accumulated worldwide is increasing. The amount of data accumulated within the city at an unprecedented level has led to the use of more electricity and the production of a lot of heat. This figure has prompted companies in the world's metropolitan areas to more efficiently utilize data and the heat generated.

This project is a data storage center using waste heat, which is proposed as a countermeasure against the current and future crises in the city. It presents an alternative to utilize the waste heat generated by many commercial buildings along with programs needed in Midtown Manhattan. In addition, it can be confirmed that a sustainable building plan using TIMBER can be proposed and it can play the role of a park, an existing site.

_Commercial Building Electricity Consumption (MWH)

Current Situation

As one of the world's largest metropolitan areas, New York City in the United States has the highest commercial building electricity usage. The site is proposed as a park surrounded by tall buildings. This is where the consumption of a lot of data within the city of Manhattan is required.

It is a wooden structure module that can be assembled into 'GAGU structure'.

Waste Heat Re-Use

ed

As technology advances, The amount of data accumulated worldwide is increasing. In the future, the development of cities using data is expect

Accordingly, the data market for managing and storing not only commercial usage but individual data usage are growing.

The energy consumption of data centers running with a large number of digital devices is enormous.

Program Design Concept

Mass Generation

Formation of programs to expand necessary facilities in the city.

Vertical mix of in-building programs for aggregated data utilization.

Flexible combination between units arranged to execute the formed program.

Floor Plan

UNIT 0 og am Massing OpennessHeight og am Massing Openness HeightUNIT 03 2 4 6 11 19 10 3 12 13 14 17 22 18 21 30 23 24 25 27 28 32 31 29 26 15 20 16 7 8 1. Server Room 2. Ware House 3. Studio 4. Smart Farm 5. Community 6. Studio 7. Fire Exingushing Gas Chamber 8. Pre-Treatment 9. Community 10. Office 11. Air Conditioning 12. Staff Room 13. Robot Charging Station 14. Office 15. Server Room 16. Study Room 17. Studio 18. Ware House 19. Library 20. Server Room 21. Smart Farm 22. Office 23. Staff Room 24. Pre-Treatment 25. Smart Farm 26. Ware House 27. Server Room 28. Studio 29. Studio 30. Farming Office 31. Smart Farm 32. Farming Office N 1/1200 Smart Farm Corridor for Robot Movement Having wide corridor of meters increase robot Smart Farm Using Waste Heat used indoor greenhouses. Studio City Community Community Studio Farm Park Office Data Center External Environment Data Center Community District heating Smart Farm Sustainability Waste Heat Digital Device Algorithm Air Conditioning Data Space Data center is convergence of ever-changing programs and sustainable. Renewable plan accumulating waste heat from data usage neighboring buildings. room heat and carbon dioxide used indoor greenhouses. agricultural water using rainwater and heat pump. Meeting space with people studio facilities using data. YouTube, private, collaboindividual creators' capabilities and stages. Coworking space for farming and data center operation. Verticalization of green spaces that existed only space for agricultural cultivation facilities Studio Office Farm Annual Size of the G obal Da asphe Z aby wth of Hype Da Mar 201 201 201 201 202 ectricity Usage of Da 200 900 201 202 202 201 201 201 202 202 Heat Pump Water Tank Waste Heat Waste Heat Waste Heat Waste Heat Rain Fall Rain Fall Water Tank Filter Treatment Ground Heat Exchange Geothermal Heat Pump Wall Glass Cover Supply (SA) Outside Air (OA) Supply Cooling Recirculated Air (CA) Cooling System Water Re-Use Rainfall collected in underground water tanks through several buildings is used for agriculture and recycled water through heat pumps. Solar Thermal The heat storage collected from waste heat and solar heat passes through the double-glazed façade and is used for internal cooling and heating and data keeping. Waste Heat Re-Use The waste heat that passes through the double-glazed façade helps power the data center and is used to operate the agricultural facilities in the tower. Mist System This technology helps to maintain green spaces on unit rooftops and irrigate green spaces located in parks. Solar Panel Solar Panels on the tower containers offset energy consumed for Data keeping and light on the day. Mechanical Ventilation The intentional movement of air into and out of a building using fans, intake vents, and exhaust vents. Double Skin Facade Through interspaces in the façade using the stack effect, internal air circulation, which is insufficient with natural ventilation, is led. Bank America Bain Company Salesfo New Co. 5th M. Baruch College Waste Heat RE-USE & C cle diag Return Air Winter Season VIA Pipe 36°C 36°C 40°C 36°C AMU Heat changer Neighbor ood Use Neighborbuildings Heat Neighbor ood Use Domestic Hot Water Space Heating G ouse / arming Heat Pump Heat Pump Room 4°C Supply Air Summer Season VIA Pipe 1°C 7°C AMU Water ank Cooling er Chiller Plant Room Radiati Night Cooling ermal Mass Centrifiugal Chiller ater/Ice Sto Heat changer Neighborbuildings Heat On-Site Reused Heat Neighbor ood Use Neighbor ood Use Heat Pump Se Room 4°C Chilled Condenser W Program Massing Openness Height Area - Community - Studio 1,800M UNIT 02 New York_26,024,809(MWH) 10 million (MWH) 1~5 million (MWH) 500 thousand 1million (MWH) 100 thousand 500 thousand (MWH) 100 thousand (MWH)
-
Site Selection
Location Timber Module & Structure Sustainability Strategies 32
Basic Massing Connected Green
Units Injuction Atrium Data Community
Layered Green Spaces Layered Programs

Dropbox (Data Center in Manhattan)

Project Description

Project name

Dropbox

1. PROJECT SUMMARY

Pointed Currrent Situation :

As technology advances, The amount of data accumulated worldwide is increasing. In the future, the development of cities using data is expected Accordingly, the data market for managing and storing not only commercial usage but individual data usage are growing. The situation that the energy consumption of data centers running with a large number of digital devices is enormous is one of the important reason of this project.

Site Info :

New York, NY 10018, Bryantpark

As one of the world's largest metropolitan areas, New York City in the United States has the highest commercial building electricity usage. The figure is more than twice as high as that of LA, the second highest in the US at 26,024,809 (MHP). In particular, the distribution of banks, offices, television networks, and entertainment industries in Manhattan's Midtown necessitates the existing of data centers. This site is proposed as a park surrounded by tall buildings. This is where the consumption of a lot of data within the city of Manhattan is required. Through the data center on the park, we propose convergence between existing green areas and programs for the city using data.

Building Info : -Floor

Proposed Programs :

Programs are proposed flexibly in relation to algorithms based on data.

Data Center - Data center is a convergence of ever-changing programs and sustainable. Smart Farm - Waste heat such as server room heat and carbon dioxide is used in indoor greenhouses. Studio - YouTube, a private, collaborative workspace for individual creators' capabilities and stages. Office - Coworking space for farming and data center operation.

Design Concept :

As data accumulates, it gives us a much wider variety of algorithms. Based on the accumulated data, it allows users to combine and experience optimal programs. In the future, the relationship between programs we will experience will be more fluid. Formation of programs to expand necessary facilities in the city. → Vertical mix of in-building programs for aggregated data utilization. → Flexible combination between units arranged to execute the formed program It is a wooden structure module that can be assembled into 'GAGU structure'.

Sustainability Strategies :

Solar Panel

Solar Panels on the tower containers offset energy consumed for Data keeping and light on the day. Water Re-Use

Rainfall collected in underground water tanks through several buildings is used for agriculture and recycled water through heat pumps.

Waste Heat Re-Use

The waste heat that passes through the double-glazed façade helps power the data center and is used to operate the agricultural facilities in the tower

Double Skin Facade

: 61F, -Gross Floor Area : 728,040m ² , -Height of the Building : 248m

Through interspaces in the façade using the stack effect, internal air circulation, which is insufficient with natural ventilation, is led. The inner shell use well – insulates timber to reduce heat loss.