EDEN Pavilion Technical Boards

Page 1

EDEN PAVILION Technical Drawings and Specifications

ELEVATIONS 1 0

B

B

Scale 1:100 5 Elevation E1

Elevation E2

Elevation E4

Elevation E3

2.1

2.2

2.3

2.4

2.5

4.1 2.6 4.2 4.3

4.4

SECTION B-B’ Scale 1:20

4.5

4.6

4.7

11. Sectioned Elevation View Scale 1:5

2.1 2.2 2.3 2.4 2.5 2.6

Timber Frame (80mmx80mm) Cavity Trim (20mmx120mm) 8mm Cement-Composite Panel Insulation Membrane Sheet (1-2mm) 3mm Size 4 (25mm Length) Screw 4.5mm Size 9 (40mm Length) Screw

4.1 4.2 4.3 4.4 4.5 4.6 4.7

Upper Surface Timber Planks (20mmx80mm) 3mm Size 4 (25mm Length) Screw 4.5mm Size 9 (50mm Length) Screw Platform Vertical Timber member (80mmx80mm) Double Screw Angle Bracket Timber Spacer for securing Screws (30mmx80mm) Key for interlocking Base to vertical member

C