INTRODUCTION
4
GOALS + OBJECTIVES 1 Design an acoustically soothing environment in the boarding areas • Use materials that surpass the requirement of acoustic standards
2 Diffuse lingering odors of ammonia, commonly associated with pet urine • Use passive ventilation consistent with Net-Zero energy efficient practices to reduce strong odors in the interior
3 Ensure that the kennel areas are fit to accommodate animals of all sizes at all times • Develop a modular system that allows for the size of each kennel or cage to be modified
4 Make supplies easily accessible from all points of the unit • Maximize square footage by increasing storage within each unit
5 Create a more sustainable interior • Use Cradle to Cradle certified materials wherever possible
5
PROBLEM STATEMENT During emergencies such as hurricanes and flooding, there is rarely a plan for moving companion animals from shelters in ‘danger zones’ to safer locations. This lack of organization often leads to miscommunication, over crowding, and potentially harmful conditions for both the animals and their care takers. This project consists of modular housing structures for companion animals that will be designed specifically for the Osceola County Animal Services Facility, located in St. Cloud, Florida. The design intent for this project is to aid animal hospitals and shelters in need of additional housing space due to the influx of companion animals seeking safety during emergencies.
THESIS STATEMENT By designing a modular, net-zero structure with sustainable materials and finishes, an efficient and comfortable space for displaced dogs and cats can be created. To enhance the efficacy of the space, materials and finishes will be carefully selected to ensure an interior that is:
6
• Easy to maintain • Efficient in reducing noise levels due to barking • Adaptable, to better meet the demands of the client • Comfortable for dogs and cats of any size
CONCEPT STATEMENT By taking inspiration from a collapsible dog crate, a product that forms space by combining rectangular geometry with looped connections, the concept of components interacting with one another to create a versatile unified form was developed. This idea informs the construction of the exterior, where pre-fabricated panels that connect to one another using simple joint geometry will be used to create the main structure. These panels help to establish how the interior will function, whether it be used for various kennels, cages or both.
Parti Diagram
7
SITE DETAILS
8
Canine Shelter Exterior Axon
The EARS will be located adjacent to St. Cloud’s Osceola County Animal Services building, which sits on 10 acres of land. The existing building is approximately 60,000 square feet, and sits on 1.7 acres of land. The additional structures will occupy approximately 2 acres, leaving 6.3 acres open for further development.
Property and Building Usage Diagram
9
GEOGRAPHY
Florida
Saint Cloud
Osceola County
St. Cloud, Florida is located on the southern shore of East Lake Tohopekaliga. This town falls within Osceola County, and is 18.68 square miles large, of which 0.11% is water.
10
OSCEOLA COUNTY ANIMAL SERVICES The shelter’s primary missions and goals consist of 3 simple ideas: • To provide the best care possible to ALL animals that come to the shelter
• To be diligent in their efforts to save lives • To educate and assist the community with animal related problems
This shelter offers various services in addition to the housing and re-homing of animals. These additional services are listed below.
Adoption Services
LEASH
Free Ride Home Program
Licensing
Field Education and Enforcement
Live animal traps
11
URBAN PLANNING
Existing Facility
Solar Panels Feline Storage
Solar Panels
Canine
Feline
Solar Panels
Water Access Entry/Exit
Solar Panels
Feline Storage
Feline
Storage
Solar Panels
Solar Panels Existing Solar Path Panels
Feline
Storage
Existing Path
Canine
Canine Canine
Water Access Water Access Entry/Exit Entry/Exit
Storage
Feline
Storage
Canine
Solar Panels
WaterAccess Access Water
Storage
Canine
Water Access
Feline
Entry/Exit Entry/Exit
Entry/Exit
Storage
Urban Planning Diagram Water Access Canine
Water Access Entry/Exit
Canine
Entry/Exit
Water Access
Canine
Storage
Feline
Solar Panels
12
Feline
Existin
Existing
Entry/Exit
Existing Path Existing Path
The urban planning of the site focuses on the circulation for staff navigating the area. The two vertical axes allow staff to transport supplies to and from shelters, while the three horizontal axes connect each shelter to water and electricity. This area is meant to be navigated via truck, golf cart or ATV.
Conceptual Urban Planning Rendering
13
EXTERIOR DETAILS
14
Custom Rapidly Deployable Panels, created by World Housing Solution, will be used for the exterior of this structure. These 4’ x 8’ panels serve as the exterior walls. These modules feature an insulative core surrounded by one or more protective skins.
Panel Composition Sketch
15
STANDARD FLOOR PANEL A
0’- 2”
4’- 0”
0’- 2”
24’- 0”
Standard Floor Panel A Plan
Tarkett LinoFloor 2 Acoustic Floor xf Frost 700 Wall Panel in Elevation Galvanized Steel Channel MycoComposite Foam Insulation
Standard Floor Panel A Section
16
Standard Floor Panel A Assembly Axon
LinoFloor 2 Acoustic Floor xf Frost 700
MycoComposite Foam Insulation
Galvanized Steel Channel
SKYGREEN PETG Resin
Standard Floor Panel A Material Axon
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida. • All materials, except the galvanized steel, are Cradle to Cradle certified. • SKYGREEN PETG Resin and LinoFloor are attached to foam insulation by a SIP bonding agent. • The SKYGREEN PETG resin and LinoFloor Acoustic Floor are flush with one another, but are offset 2” into the MycoComposite foam, leaving a 2”groove on one end of the panel, and a 2” tail on the opposite end. This customization allows for the panels to slide into one another and creates an airtight seal.
17
STANDARD FLOOR PANEL B
24’- 0”
0’- 4” 0’- 1/8”
23’- 3 1/2”
0’- 1/8”
0’- 4 1/2”
4’- 2”
0’- 1/8”
0’- 4” 0’- 1/8”
Standard Floor Panel B Plan
el A
Pan
Tarkett LinoFloor 2 Acoustic Floor xf Frost 700 Wall Panel in Elevation Galvanized Steel Channel
el A
Pan
MycoComposite Foam Insulation
Standard Floor Panel B Section
18
Standard Floor Panel B Assembly Axon
LinoFloor 2 Acoustic Floor xf Frost 700
Galvanized Steel Channel MycoComposite Foam Insulation
SKYGREEN PETG Resin
Standard Floor Panel B Material Axon
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida. • All materials, except the galvanized steel, are Cradle to Cradle certified. • SKYGREEN PETG Resin and LinoFloor are attached to foam insulation by a SIP bonding agent. • The SKYGREEN PETG resin and LinoFloor Acoustic Floor are flush with one another, but are offset 2” into the MycoComposite foam, leaving a 2”groove on one end of the panel, and a 2” tail on the opposite end. This customization allows for the panels to slide into one another and creates an airtight seal.
19
8’- 0”
0’- 0 1/4”
0’- 3 1/2”
7’- 11 3/4”
0’- 0 1/4”
STANDARD WALL PANEL A
Standard Wall Panel A Plan
Interior
Exterior
Tarkett 2 LinoWall xf Jute 315 SKYGREEN PETG Resin
Galvanized Steel Frame
MycoComposite Foam Insulation
Standard Wall Panel A Section
20
Standard Wall Panel A Assembly Axon
8’- 0”
0’- 0 1/4” 6’- 11”
0’- 1 3/4” 0’- 4 1/2”
6’- 9 1/4”
0’- 2”
0’- 2”
0’- 0 1/4”
1’- 6”
0’- 4 1/2”
0’- 4 3/4”
0’- 1 3/4”
Standard Wall Panel A Interior Elevation
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida.
• All materials and installations, except the galvanized steel, are Cradle to Cradle certified.
• SKYGREEN PETG Resin and LinoWall are attached to the foam insulation by a SIP bonding agent.
• Windows are placed using typical World Housing Solution construction.
21
2’- 3”
0’- 3”
3’- 0”
0’- 3”
2’- 3”
8’- 0” Standard Wall Panel B Plan
Interior
Exterior
Tarkett 2 LinoWall xf Jute 315 SKYGREEN PETG Resin
Galvanized Steel Frame
MycoComposite Foam Insulation
Standard Wall Panel B Section
22
Standard Wall Panel B Axon
0’- 3 1/2”
0’- 4”
STANDARD WALL PANEL B
0’- 3”
3’- 0”
0’- 3”
2’- 3”
0’- 5”
7’- 0”
1’- 7”
2’- 3”
Standard Wall Panel B Interior Elevation
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida.
• All materials and installations, except the galvanized steel, are Cradle to Cradle certified.
• SKYGREEN PETG Resin and LinoWall are attached to the foam insulation by a SIP bonding agent.
• Doors are placed using typical World Housing Solution construction.
23
CANINE FLOOR PANEL A 0’- 0 1/8” 0’- 5” 0’- 7 1/2”
0’- 7 1/2”
21’- 3”
0’- 2”
0’- 2” 3’- 8”
0’- 2”
0’- 4” 0’- 0 1/8”
Canine Floor Panel A Plan
Canine Floor Panel A Assembly Axon
0’- 3 7/8” 0’- 1/2”1/8”
12”
Canine Floor Panel A Section
24
0’- 1/8” 0’- 5”
22’- 5 1/2”
0”
12”
1/8”
0’- 3 7/8” 0’- 1/2” 12”
0’- 4” 0’- 1/8” 0’- 1/2”
0’- 1/4”
0’- 1/2”
0’- 1/8” 0’- 5”
0’- 5 1/4” 0’- 3 1/2”
0’- 4” 0’- 1/8”
Galvanized Steel Drain Cover
Tarkett LinoFloor 2 Acoustic Floor xf Frost 700
Galvanized Steel Channel MycoComposite Foam Insulation
SKYGREEN PETG Resin
Canine Floor Panel A Material Axon
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida.
• All materials and installations, except the galvanized steel, are Cradle to Cradle certified.
• SKYGREEN PETG Resin and LinoWall are attached to the foam insulation by a SIP bonding agent.
• Each panel is customized to accommodate a tunnel drain system and grate. This system filters black water into the plumbing below the structure via sloped pipes that connect to the existing septic tank on the property.
25
CANINE FLOOR PANEL B 24’- 0” 0’- 0 1/8” 0’- 5” 0’- 7 1/2”
0’- 0 1/8” 0’- 5” 0’- 7 1/2”
21’- 3”
0’- 4” 0’- 0 1/8” 0’- 4” 3’- 6” 0’- 4” 0’- 0 1/8” 0’- 0 1/8”
0’- 4” 0’- 0 1/8”
Canine Floor Panel B Plan
el A
el A
Pan
Pan
Canine Floor Panel B Assembly Axon
0’- 3 7/8” 0’- 1/2”1/8”
12”
Canine Floor Panel B Section
26
0’- 1/8” 0’- 5”
22’- 5 1/2”
0”
12”
1/8”
0’- 3 7/8” 0’- 1/2” 12”
0’- 4” 0’- 1/8” 0’- 1/2”
0’- 1/4”
0’- 1/2”
0’- 1/8” 0’- 5”
0’- 5 1/4” 0’- 3 1/2”
0’- 4” 0’- 1/8”
Galvanized Steel Drain Cover
Tarkett LinoFloor 2 Acoustic Floor xf Frost 700
Galvanized Steel Channel MycoComposite Foam Insulation
SKYGREEN PETG Resin
Canine Floor Panel B Material Axon
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida.
• All materials and installations, except the galvanized steel, are Cradle to Cradle certified.
• SKYGREEN PETG Resin and LinoWall are attached to the foam insulation by a SIP bonding agent.
• Each panel is customized to accommodate a tunnel drain system and grate. This system filters black water into the plumbing below the structure via sloped pipes that connect to the existing septic tank on the property.
27
8’- 0”
0’- 0 1/4”
0’- 3 1/2”
7’- 11 3/4”
0’- 0 1/4”
CANINE WALL PANEL A
Canine Wall Panel A Plan
Interior
Exterior
Tarkett 2 LinoWall xf Flax 350 SKYGREEN PETG Resin
Galvanized Steel Frame
MycoComposite Foam Insulation
Canine Wall Panel A Section
28
Canine Wall Panel A Assembly Axon
0’- 1 3/4” 0’- 4 1/2” 0’- 4 3/4”
6’- 11”
0’- 0 1/4”
6’- 9 1/4”
0’- 2”
0’- 2”
0’- 0 1/4”
1’- 6”
0’- 1 3/4” 0’- 4 1/2”
Canine Wall Panel A Interior Elevation
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida.
• All materials and installations, except the galvanized steel, are Cradle to Cradle certified.
• SKYGREEN PETG Resin and LinoWall are attached to the foam insulation by a SIP bonding agent.
• Windows are placed using typical World Housing Solution construction.
29
2’- 3”
0’- 3”
3’- 0” 8’- 0”
0’- 3”
2’- 3”
0’- 3 1/2”
0’- 4”
CANINE WALL PANEL B
Canine Wall Panel B Plan
Interior
Exterior
Tarkett 2 LinoWall xf Flax 350 SKYGREEN PETG Resin
Galvanized Steel Frame
MycoComposite Foam Insulation
Canine Wall Panel B Section
30
Canine Wall Panel B Exterior Axon
8’- 0” 0’- 3”
3’- 0”
0’- 3”
2’- 3”
0’- 9”
7’- 0”
1’- 3”
2’- 3”
Canine Wall Panel B Interior Elevation
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida.
• All materials and installations, except the galvanized steel, are Cradle to Cradle certified.
• SKYGREEN PETG Resin and LinoWall are attached to the foam insulation by a SIP bonding agent.
• Doors are placed using typical World Housing Solution construction.
31
CANINE WALL PANEL C
1’- 6”
1’- 3”
Canine Wall Panel C Plan
Interior
Exterior
Tarkett 2 LinoWall xf Flax 350 SKYGREEN PETG Resin Galvanized Steel Door Slot Galvanized Steel Frame
MycoComposite Foam Insulation
Canine Wall Panel C Section
32
Canine Wall Panel C Interior Axon
0’- 3 1/2”
2’- 6”
0’- 0 1/4”
1’- 6”
0’- 0 1/4” 0’- 0 1/4”
1’- 3”
0’- 0 1/4”
8’- 0”
8’- 0” 6’- 11”
0’- 0 1/4” 0’- 1 3/4”
0’- 1 3/4” 0’- 0 1/4” 6’- 9 1/4”
2’- 6”
2’- 4 1/2”
1’- 6”
1’- 6 1/4” 0’- 1 1/2” 0’- 1 1/2”
0’- 4 3/4” 0’- 1 3/4” 0’- 0 1/4”
0’- 4 1/2”
0’- 1 3/4” 0’- 0 1/4”
Canine Wall Panel C Interior Elevation
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida. • All materials and installations, except the galvanized steel, are Cradle to Cradle certified. • SKYGREEN PETG Resin and LinoWall are attached to the foam insulation by a SIP bonding agent. • Doors are placed using typical World Housing Solution construction. • Guillotine door details located on page 48
33
CEILING PANEL A 24’- 0” 0’- 4” 0’- 1/8”
23’- 3 1/2”
0’- 1/8”
Ceiling Panel A Plan
DerbiPure Galvanized Steel Channel MycoComposite Foam Insulation Fade Acoustic Plaster Plus+ Standard White Wall Panel in Elevation
Ceiling Panel A Section
34
Ceiling Panel A Axon
0’- 2”
0’- 1/8”
4’- 0”
0’- 4” 0’- 1/8”
DerbiPure
Galvanized Steel Channel
MycoComposite Foam Insulation
Fade Acoustic Plaster Plus+ Standard White
Ceiling Panel A Material Axon
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida. • All materials, except the galvanized steel, are Cradle to Cradle certified. • DerbiPure and Fade Acoustic Plaster are attached to foam insulation by a SIP bonding agent. • The DerbiPure Sheet and Fade Acoustic Plaster are flush with one another, but are offset 2” into the MycoComposite foam, leaving a 2”groove on one end of the panel, and a 2” tail on the opposite end. This customization allows for the panels to slide into one another and creates an airtight seal. The panels are wedged together using rubber mallets.
35
CEILING PANEL B 24’- 0” 23’- 3 1/2”
0’- 4” 0’- 1/8”
0’- 1/8”
Ceiling Panel B Plan
DerbiPure Galvanized Steel Channel MycoComposite Foam Insulation Fade Acoustic Plaster Plus+ Standard White Wall Panel in Elevation
Ceiling Panel B Section
36
Ceiling Panel B Axon
0’- 4 1/8”
0’- 4” 0’- 1/8”
4’- 2 1/8”
0’- 1/8”
DerbiPure Galvanized Steel Channel MycoComposite Foam Insulation
Fade Acoustic Plaster Plus+ Standard White
Ceiling Panel B Material Axon
MATERIAL DETAILS • All panels are pre-fabricated in the World Housing Solution warehouse in Sanford, Florida. • All materials, except the galvanized steel, are Cradle to Cradle certified. • DerbiPure and Fade Acoustic Plaster are attached to foam insulation by a SIP bonding agent. • The DerbiPure Sheet and Fade Acoustic Plaster are flush with one another, but are offset 2” into the MycoComposite foam, leaving a 2”groove on one end of the panel, and a 2” tail on the opposite end. This customization allows for the panels to slide into one another and creates an airtight seal. The panels are wedged together using rubber mallets.
37
INTERIOR DETAILS
38
The interior of each EARS is designed to be completely customizable to accommodate the various needs of different animals. The furnishings and fixtures in these spaces are either pre-fabricated and placed inside or are attached on-site using a pin joint.
Pin Joint Sketch
39
FELINE HOUSING CONDO 5' -- 6” 6" 5’ - 03/4” 3/4" 0’ 0' -0
1/2" 0’0'--111/2”
1’1'-- 44 1/2” 1/2"
- 03/4” 3/4" 0’ 0' -0 10 1/2” 1/2" 1’1'--10
0’ - 8 3/4” 0' - 8 3/4"
1’1'-- 11 1/4" 1/4”
2’2'-- 0" 0”
0’- 0- 3/4" 0 3/4” 0'
1’ 10 1/2" 1/2” 1' -- 10
0’0'--111/2” 1/2"
Feline Housing Condo Plan
0' - 0 3/4"
1' - 10 1/2"
0' - 8 3/4"
Feline Housing Condo Axon
40
0' - 2 23/32"
0' - 5 3/8"
1' - 5 3/4"
0' - 2 25/32" 0' - 6 1/2"
0' - 2 23/32"
1' - 5 3/4"
- 3 1/8"
0' - 5 3/8" 0' - 2 25/32"
Staff Changing the Litter in Cat Condo
DETAILS • These cat condos will be produced and shipped by Mason Company, and installed on-site. • To achieve a more residential atmosphere, a wood veneer by WilsonArt will be used. This product is commonly used in this type of construction. • Glass windows will be attached at the front the back of each unit. The use of glass in high-occupancy spaces like this is preferred, to reduce the spread of contagious diseases. • These units can hold up to four large cats, and feature a separate compartment for litter. • The litter compartments include an air filter system that pulls the contaminated air into a ventilation system; this helps to reduce the smell of ammonia associated with cat urine.
41
0’ - 0 3/4”
0’ - 0 3/4”
CANINE INDOOR KENNEL
0’ - 0 13/16”
Canine Indoor Kennel Plan
Canine Indoor Kennel Axon
42
0’ - 0 3/4”
0’ - 2 3/4”
3’ - 11 1/4”
5’ - 11 1/4”
Staff Hosing Down a Kennel
DETAILS • These custom indoor dog kennels will be produced and shipped by Mason Company, and installed on-site. • To achieve a more residential atmosphere, a wood veneer by WilsonArt will be used. This product is commonly used in this type of construction. • The wall panels for these kennels feature a rubber beveled insert that is used to prevent cross contamination of liquids from one kennel to another. • Each kennel is designed to house one large dog, or two small dogs. • The panels that create the walls for each kennel are connected to the wall using a pin joint. This allows for the kennels to be installed at any dimension, although 4’ is the recommended size based on the door size.
43
CANINE OUTDOOR KENNEL 5’ - 10”
3’ - 2”
0’ - 2”
Canine Outdoor Kennel Plan
Canine Outdoor Kennel Axon
44
0’ - 2”
Outdoor Kennels
DETAILS • The outdoor kennels are constructed of chain link fencing, this allows for further customization if necessary.
• An additional sheet of galvanized steel is used in front of the supporting platform to ensure that each kennel is secure.
• The fencing is connected to the wall panels using a pin joint. This allows for the kennels to be installed at any dimension, although 4’ is the recommended size based on the door size.
• Each kennel is designed to house one large dog, or two small dogs.
45
CANINE OUTDOOR ACCESS 0’ - 1 1/4”
0’ - 1 1/4” 0’ - 1 1/4”
0’ - 1 1/4”
4’ - 3”
0’ - 0 1/4”
0’ - 0 1/4”
1’ - 6 1/4”
Canine Outdoor Access Ramp Plan
Stair + Ramp Installation Diagram
46
0’ - 9” 0’ - 9” 0’ - 9”
Canine Outdoor Access Stair Plan
DETAILS • A stair or ramp attachment is necessary for outdoor access because the kennel structures are raised 1’-10” from grade. • Each Canine Wall Panel C will be accompanied by two stair attachments and two ramp attachments. This allows for maximum customization based on any mobility restrictions of each animal. • The ramp and stair attachments are constructed of wood, and feature a galvanized steel edge for installation purposes. • To install the ramp or stair attachment, the user would place the stair or ramp’s metal edge into the floor channel before or after the Canine Wall Panel C is installed. This channel is custom made to fit both the wall and access unit securely.
47
CANINE OUTDOOR ACCESS
Canine Wall Panel C Guillotine Door Axon
Canine Wall Panel C Exploded Axon
48
Staff Raising the Guillotine Door
DETAILS • The guillotine door and its attachment fixtures are made of galvanized steel. • A pulley system is used to open and close the guillotine door for each kennel. This system involves a chain with a hook on one end, to attach to the guillotine door, and a weight on the other. Once installed, the staff pull down on the weight to open the door. • The weight has an attachment hook on both ends, so that they can be connected to the chain and also locked into place if necessary. • To ensure that dogs of all shapes and sizes can use this access system, the doors for this project surpass the recommended doggy door size for extra-large dogs.
49
LIGHTING
Natural Light Diagram
Because the shelter has windows on each face, natural light will help to illuminate the space during the day time.
KAUK sketch
Although any lighting fixture can be used in the EARS, the recommended product is the KUAK by GARVILED. This suspended fixture is Cradle to Cradle certified and comes in various sizes.
50
Platek’s One 2.0 Down light and Mini ONE Bollard Sketches
Outdoor lighting is used along the travel paths and on the facade of each EARS. Any outdoor lighting fixture could be used, but the recommended products are Platek’s ONE 2.0 down light and Mini ONE Bollard. By using these two products, the outdoor paths are safe and cohesive.
51
FLOOR PLANS + NET-ZERO DESIGN DETAILS
52
Net-zero design consists of the idea that buildings can meet their annual energy requirements by using low-cost, locally available and non-polluting renewable sources. The site and structures facilitate net-zero design by the use of passive cooling, water catchment systems, sloped drainage and other unique features.
Net-Zero Energy Diagram
53
FELINE EARS
6 24’ - 8”
4’ - 0”
4’ - 2”
24’ - 0”
7
7’ - 10”
6’ - 10”
1 2
3 4
5 Feline EARS Plan Example
54
DETAILS 1
Each EARS uses ULINE heavy duty steel shelving or a similar product.
2
Storage racks are located in both feline and canine shelters for ease of access. The feline and canine storage racks can be restocked using the bulk items stored in the designated storage shelters.
3
All windows are operable for passive cooling and cross ventilation.
4
The windows and doors used for these spaces are manufactured by WICONA. These windows and doors are highly insulated and Cradle to Cradle certified.
5
These shelters access water by use of a spigot and hose on the exterior.
6
The floor plan shown is 24’ x 24’ but the size of these shelters can vary as needed. Users can make shelters smaller or larger by using more or less panels. Sizes vary in 8 foot increments.
7
The main corridor in the space is enlarged to ensure that bulky supplies can be moved easily.
55
STORAGE SHELTER
3’ - 2”
24’ - 0”
3’ - 0”
7
3’ - 0”
24’ - 8”
6
3’ - 2”
3’ - 2”
3 1
2
4
5 Storage Shelter Plan Example
56
DETAILS 1
Each shelter uses ULINE heavy duty steel shelving or a similar product.
2
Storage racks are located in both feline and canine shelters for ease of access. The feline and canine storage racks can be restocked using the bulk items stored in the designated storage shelters.
3
All windows are operable for passive cooling and cross ventilation.
4
The windows and doors used for these spaces are manufactured by WICONA. These windows and doors are highly insulated and Cradle to Cradle certified.
5
These shelters access water by use of a spigot and hose on the exterior.
6
The floor plan shown is 24’ x 24’ but the size of these shelters can vary as needed. Users can make shelters smaller or larger by using more or less panels. Sizes vary in 8 foot increments.
7
Storage racks are spaced 6 inches away from each other to accommodate extra large and irregularly shaped bulk items.
57
CANINE EARS
3’ - 11”
24’ - 0”
24’ - 8”
7
6 12’ - 0”
1
2
3’ - 11”
3 4 5
Canine EARS Plan Example
58
DETAILS 1
Each EARS uses ULINE heavy duty steel shelving or a similar product.
2
Storage racks are located in both feline and canine shelters for ease of access. The feline and canine storage racks can be restocked using the bulk items stored in the designated storage shelters.
3
All windows are operable for passive cooling and cross ventilation.
4
The windows and doors used for these spaces are manufactured by WICONA. These windows and doors are highly insulated and Cradle to Cradle certified.
5
These shelters access water by use of a spigot and hose on the exterior.
6
The floor plan shown is 24’ x 24’ but the size of these shelters can vary as needed. Users can make shelters smaller or larger by using more or less panels. Sizes vary in 8 foot increments.
7
The main corridor in the shelter is large enough to open all of the kennels and still walk through the space.
59
ASSEMBLY OPTIONS
60
The process of assembling these structures is repetitive and constant until finished. With 5-6 adults, one EARS can be constructed in approximately 2 hours.
Simplified Panel Assembly Sketch
61
FELINE EARS ASSEMBLY OPTION 1
Feline EARS Assembly Option 1 Plan
Feline EARS Assembly Option 1 Axon
62
DETAILS Exterior Parts Needed: 4 Standard Floor Panel A 2 Standard Floor Panel B 8 Floor Panel Channel 11 Standard Wall Panel A
1 Standard Wall Panel B 4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel
Interior Parts Needed: 12 Mason Company Cat Condo 6 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit
The recommended installation procedure is as follows:
1
Place 1 Standard Floor Panel B and then insert the Standard Floor Panel A’s. Then place the remaining Floor Panel B and secure the Floor Panel Channels onto each of the Standard Floor Panel A’s.
2
Determine which side will be the entrance of the shelter and position 1 Standard Wall Panel A into the respective floor channel (on either the far left or right). Next place the Standard Wall Panel B and 1 Standard Wall Panel A to complete the entrance wall facade.
3
Position 1 Standard Wall Panel A in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel A parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Standard Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
63
FELINE EARS ASSEMBLY OPTION 2
Feline EARS Assembly Option 2 Plan
Feline EARS Assembly Option 2 Axon
64
DETAILS Exterior Parts Needed: 4 Standard Floor Panel A 2 Standard Floor Panel B 8 Floor Panel Channel 11 Standard Wall Panel A
1 Standard Wall Panel B 4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel
Interior Parts Needed: 12 Mason Company Cat Condo 6 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit
The recommended installation procedure is as follows:
1
Place 1 Standard Floor Panel B and then insert the Standard Floor Panel A’s. Then place the remaining Floor Panel B and secure the Floor Panel Channels onto each of the Standard Floor Panel A’s.
2
Determine which side will be the entrance of the shelter and position 1 Standard Wall Panel A into the respective floor channel (on either the far left or right). Next place the Standard Wall Panel B and 1 Standard Wall Panel A to complete the entrance wall facade.
3
Position 1 Standard Wall Panel A in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel A parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Standard Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
65
FELINE EARS ASSEMBLY OPTION 3
Feline EARS Assembly Option 3 Plan
Feline EARS Assembly Option 3 Axon
66
DETAILS Exterior Parts Needed: 4 Standard Floor Panel A 2 Standard Floor Panel B 8 Floor Panel Channel 11 Standard Wall Panel A
1 Standard Wall Panel B 4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel
Interior Parts Needed: 12 Mason Company Cat Condo 6 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit
The recommended installation procedure is as follows:
1
Place 1 Standard Floor Panel B and then insert the Standard Floor Panel A’s. Then place the remaining Floor Panel B and secure the Floor Panel Channels onto each of the Standard Floor Panel A’s.
2
Determine which side will be the entrance of the shelter and position 1 Standard Wall Panel A into the respective floor channel (on either the far left or right). Next place the Standard Wall Panel B and 1 Standard Wall Panel A to complete the entrance wall facade.
3
Position 1 Standard Wall Panel A in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel A parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Standard Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
67
STORAGE SHELTER ASSEMBLY OPTION 1
Storage Shelter Assembly Option 1 Plan
Storage Shelter Assembly Option 1 Axon
68
DETAILS Exterior Parts Needed: 4 Standard Floor Panel A 2 Standard Floor Panel B 8 Floor Panel Channel 11 Standard Wall Panel A
1 Standard Wall Panel B 4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel
Interior Parts Needed: 36 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit
The recommended installation procedure is as follows:
1
Place 1 Standard Floor Panel B and then insert the Standard Floor Panel A’s. Then place the remaining Floor Panel B and secure the Floor Panel Channels onto each of the Standard Floor Panel A’s.
2
Determine which side will be the entrance of the shelter and position 1 Standard Wall Panel A into the respective floor channel (on either the far left or right). Next place the Standard Wall Panel B and 1 Standard Wall Panel A to complete the entrance wall facade.
3
Position 1 Standard Wall Panel A in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel A parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Standard Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
69
STORAGE SHELTER ASSEMBLY OPTION 2
Storage Shelter Assembly Option 2 Plan
Storage Shelter Assembly Option 2 Axon
70
DETAILS Exterior Parts Needed: 4 Standard Floor Panel A 2 Standard Floor Panel B 8 Floor Panel Channel 11 Standard Wall Panel A
1 Standard Wall Panel B 4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel
Interior Parts Needed: 36 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit
The recommended installation procedure is as follows:
1
Place 1 Standard Floor Panel B and then insert the Standard Floor Panel A’s. Then place the remaining Floor Panel B and secure the Floor Panel Channels onto each of the Standard Floor Panel A’s.
2
Determine which side will be the entrance of the shelter and position 1 Standard Wall Panel A into the respective floor channel (on either the far left or right). Next place the Standard Wall Panel B and 1 Standard Wall Panel A to complete the entrance wall facade.
3
Position 1 Standard Wall Panel A in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel A parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Standard Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
71
CANINE EARS ASSEMBLY OPTION 1
Canine EARS Assembly Option 1 Plan
Canine EARS Assembly Option 1 Axon
72
DETAILS Exterior Parts Needed: 4 Canine Floor Panel A 2 Canine Floor Panel B 2 Canine Wall Panel A 1 Canine Wall Panel B 6 Canine Wall Panel C
4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel 10 Chain link Fence Walls 8 Chain link Fence Gates
Interior Parts Needed: 8 Custom Mason Company Dog Kennels 6 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit The recommended installation procedure is as follows:
1
Place 1 Canine Floor Panel B and then insert the Canine Floor Panel A’s. Then place the remaining Floor Panel B to complete the floor unit.
2
Determine which side will be the entrance of the shelter and position 1 Canine Wall Panel A into the respective floor channel (on either the far left or right). Next place the Canine Wall Panel B and 1 Canine Wall Panel A to complete the entrance wall facade.
3
Position 1 Canine Wall Panel C in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel C parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Canine Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
73
CANINE EARS ASSEMBLY OPTION 2
Canine EARS Assembly Option 2 Plan
Canine EARS Assembly Option 2 Axon
74
DETAILS Exterior Parts Needed: 4 Canine Floor Panel A 2 Canine Floor Panel B 2 Canine Wall Panel A 1 Canine Wall Panel B 6 Canine Wall Panel C
4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel 14 Chain link Fence Walls 12 Chain link Fence Gates
Interior Parts Needed: 12 Custom Mason Company Dog Kennels 8 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit The recommended installation procedure is as follows:
1
Place 1 Canine Floor Panel B and then insert the Canine Floor Panel A’s. Then place the remaining Floor Panel B to complete the floor unit.
2
Determine which side will be the entrance of the shelter and position 1 Canine Wall Panel A into the respective floor channel (on either the far left or right). Next place the Canine Wall Panel B and 1 Canine Wall Panel A to complete the entrance wall facade.
3
Position 1 Canine Wall Panel C in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel C parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Canine Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
75
CANINE EARS ASSEMBLY OPTION 3
Canine EARS Assembly Option 3 Plan
Canine EARS Assembly Option 3 Axon
76
DETAILS Exterior Parts Needed: 4 Canine Floor Panel A 2 Canine Floor Panel B 2 Canine Wall Panel A 1 Canine Wall Panel B 6 Canine Wall Panel C
4 Ceiling Panel A 2 Ceiling Panel B 8 Ceiling Panel Channel 10 Chain link Fence Walls 8 Chain link Fence Gates
Interior Parts Needed: 8 Custom Mason Company Dog Kennels 8 ULINE Heavy Duty Storage Shelves 4 GARVILED KUAK Suspended Light Fixture 1 Window Air Conditioner Unit The recommended installation procedure is as follows:
1
Place 1 Canine Floor Panel B and then insert the Canine Floor Panel A’s. Then place the remaining Floor Panel B to complete the floor unit.
2
Determine which side will be the entrance of the shelter and position 1 Canine Wall Panel A into the respective floor channel (on either the far left or right). Next place the Canine Wall Panel B and 1 Canine Wall Panel A to complete the entrance wall facade.
3
Position 1 Canine Wall Panel C in the floor channel perpendicular to the entrance wall. Place 1 Standard Wall Panel C parallel to the one just installed.
4
Next, position 1 Ceiling Panel B onto the entrance wall and the perpendicular side walls. This will help secure the wall panels that have been installed. Then insert 1 Ceiling Panel A to cover the current structure.
5
Continue to place the remaining Canine Wall Panel’s and Ceiling Panels in a similar manner until the structure is complete.
6
Install interior fixtures where needed and place furnishings.
77
CITATIONS
78
79
GEOGRAPHY https://www.osceola.org/about-osceola-county/general-information/ economy.stml https://www2.census.gov/geo/docs/maps-data/data/gazetteer/2016_ Gazetteer/2016_gaz_place_12.txt https://msc.fema.gov/portal/search#searchresultsanchor https://www.stcloud.org/ https://statesummaries.ncics.org/chapter/fl/
PROGRAMMING https://www.osceolacountypets.com/mission/ https://www.osceolacountypets.com/our-team/ https://www.sheltermedicine.com/library/resources/?r=all-you-need-toknow-about-housing-dogs-in-animal-shelters
DESIGN https://tcvccares.com/ Tour of Town and Country Veterinary Clinic Tour of Montgomery County Animal Care and Adoption Center Contact with Bill Wenchell from TWC Construction Contact with Ron Ben-Zeev from World Housing Solution
80
CONSULTATIONS Blake Woodall from Ayers Construction Alex Barrette from WestRock Company Kaitey Crouse from LPA
ANIMAL MODELS Riley Brads Cali Woodall Cash Woodall Tigger Grennon Pumpkin Grennon
81
82
83