Dynamics System
Document No: D0155 (Revision 8)
Motion: Using Light gates on a slope to measure speed or acceleration Measuring speed with one Light gate
Attach the track to the vertical pillar with the top edge of the track at the 5 cm mark (the vertical height on the support pillar divided by 2 gives the angle). Fit a crash box (page 10) at the bottom of the track.
Position a Light gate approximately 20 cm from the top of the track and connect to input A on the EasySense data logger.
Fit the interrupt card to the cart so the single interrupt edge will pass through the Light gate.
Open the EasySense program and select Timing. Select to record Speed at A with a single interrupt card, and enter the length of the card as 120 mm.
Select Start to begin. Position the cart in the start position at the top of the track and release the cart.
Adjust the track to a new height / angle, and repeat using the same start position each time.
To Input A
Measuring acceleration with one Light gate
Fit the interrupt card to the cart so the double interrupt edge will pass through the Light gate.
Select to record Acceleration at A with a double interrupt card, and enter the length of the interrupt card segment as 40 mm.
Proceed as before.
14 Data Harvest Group Ltd.