PORTAFOLIO INSTALACIONES II ALEX VIVANCO

Page 1

PORTAFOLIO 2021-0

INSTALACIONES II 5

6

4

2S (3) 5,6

S (3) 4

2S (3) 5,6

S7

4

5

4 (3) S

S 14

S (3) 4

14 S

5,6 (3) 2S

4 (3) S

S (3) 3

SH8

9

7 SH

ALEX MIGUEL VIVANCO DAMIAN 20161559 S8

14

14

3 (3) S

14

14

3

S9

3

15 S

S 15

2S (3) 10,11

10

15

2S

15

3

3

11

S 16

16 S

2S (3) 12,13

2S

16

16

S (3) 3

2S (3) 1,2

3 (3) S

1,2 (3) 2S

12 2

1

1

2S (3) 1

2

1(3) 2S

13

S 20

S 20

18

18

S 19

S 18 2S(3) 1,2

Profesores JOSE LUIS REYES ÑIQUE

3

1

2

1

S3 S(3) 8

2S(3) 1,2

2S(3) 4,5

2

4,5 2S(3)

S6

S7

6S

SH 8

7

SH 6

5

4

4

5

2S(3) 4,5

S 18

4,5 2S(3)

S9

9S 9

18

8

18

11 S

11

S(3) 10

S(3) 10

8

10

10

18 S

9

S 11

S(3) 8

6

11

10 (3)S

10

10

S(3) 16

10

16 (3)S

2S(3) 14,17

14,17 2S(3)

621

17

17

12

SH S(3) 12 14

13

16

15

16

15

S(3) 13

15

S(3) 15

Facultad de Ingeniería y Arquitectura

15

15 (3)S

4.60

Carrera de Arquitectura - Área de CONSTRUCCIÓN Y ESTRUCTURAS Ciclo 2021-0 1.93

4.80

1.77

1.88

1.93

1.88

1.08


4

.25

7.00

A

.60 .80 .15 1.45 .15 .95

B

.60

6

5,6 (3) 2S

3.00

SALA DE ESTAR

.15 .75

SH

8

C

9 8S

.60 .15

9S

1 (3) 2S

2.66

10

DORMITORIO PRINCIPAL 11

10,11 (3) 2S

DORMITORIO 2

.15

12,13 (3) 2S

3.04 12

D

.60

3.30

.60 .15

E

39.97

3

4.50

SALA DE ESTAR 3S 8 (3)S

7S

.60 .15

B

F

.89 7

8

1.33

ORMITORIO 1

5.08

.15 6.00

1.64 8

0

2.55

10 (3)S

8

.90

10

8 (3)S

.60

12

SH

G

1.98

12 (3)S

.15

13 (3)S

13

2.47

H 1.15


INTRODUCCIÓN En el presente portafolio se presenta el compendio de trabajos realizados durante el periodo academico 2021-0 del curso INSTALACIONES II de la carrera de Arquitectura de la Universidad de Lima. En este curso se trabajaron conceptos practicos para el desarrollo de las instalaciones electricas y mecanicas en un proyecto arquitectonico.


CONTENIDO 01

02

03

-PC1: DEMANDA INSTALADA

-TRBAJO: MEMORIA DESCRIPTIVA

-LABORATORIO 1: ALUMBRADO

CRITERIOS RIBA

CRITERIOS RIBA

CRITERIOS RIBA

CG10

CG7, CG11

CG1, CG5, CG8, CG10

pag. 6-9

-PC2: ALUMBRADO

04

CRITERIOS RIBA CG1, CG5, CG8, CG9, CG10

pag. 34-35

pag. 10-27

-DISEÑO: ALUMBRADO

05

pag. 28-33

06

-LABORATORIO 2: TOMACORRIENTES

CRITERIOS RIBA

CRITERIOS RIBA

CG1, CG5, CG8, CG9, CG10, CG11

CG1, CG5, CG8, CG9, CG10

pag. 36-43

pag. 44-51


-PC3: TOMACORRIENTES

07

08

-DISEÑO: TOMACORRIENTES

CRITERIOS RIBA

CRITERIOS RIBA

CG1, CG5, CG8, CG9, CG10

CG1, CG5, CG8, CG9, CG10, CG11

pag. 52-57

-CUIRRICULUM VITAE

cv

pag. 68-69

pag. 58-65

inf.

-INFORMACION DEL CURSO

pag. 66-67


01. PC1: Demanda Instalada

ENCARGO Calcular la potencia instalada y demanda máxima de potencia que requerirán las nstalaciones proyectadas, tales como viviendas unifamiliares o edificios dediferentes usos.

EP1 CRITERIOS RIBA CG10

pag. 5


pregunta 1: un plano que represente una expresion completa del proyecto. que exprese claramente las obras de este con los detalles mas importantes preunta 2:centro de luz tomacorrientes slaida para cocina elecctrica interruptor de calentador de agua salida de artefactos electrodomesticos ubicacion de tablero general ubicacion de medidor de energia union de interconexion entre el medidr de energia electrica y el tablero general cierre de circuitos

EDIFICIO 1 D1 (75m2) primeros 45m2 siguientes 45m2 o fracción cocina electrica terma horno microondas refrigeradora

Potencia Instalada

10.35 kw D2 (90m2) primeros 45m2 siguientes 45m2 o fracción adicionales 90m2 o fraccion cocina electrica termas microondas refrigeradora

1500 1000 4500 1500 1500 350 10350

Potencia Instalada

1500 1000

Factor de Demanda

Factor de Demanda

4500 1500 1500 450

Potencia Instalada

1500 1000 2000 6000 4500 1500 450 4000 20950 20.95

Maxima Demanda

10.35 kw

10450 10.45 D3 (200M2) primeros 45m2 siguientes 45m2 o fracción adicionales cada 90m2 o fraccion cocina electrica 3 termas microondas refrigeradora secadora

100 100 100 100 100 100

Factor de Demanda

100 100 100 100 100 100 100 100

100 100 100 100 75 100 100 100

Maxima Demanda

Maxima Demanda

1500 1000 4500 1500 1500 350 10350

1500 1000 0 4500 4500 1500 450 0 13450 13.45

1500 1000 2000 6000 3375 1500 450 4000 19825 19.825

pag. 6


CAPACIDAD DEL EDIFICIO

El 100% de la carga mayor de cualquier unidad de vivienda; más El 65% de la suma de cargas de las 2 unidades de vivienda con cargas iguales o inmediatamente menores a la del subpárrafo (i); más El 40% de la suma de cargas de las 2 unidades de vivienda con cargas iguales o inmediatamente menores que las del subpárrafo (ii); más El 30% de la suma de las cargas de las 15 unidades de vivienda con cargas iguales o inmediatamente menores a las del subpárrafo (iii); más El 25% de la suma de las cargas de las unidades de vivienda restantes. Cualquier carga de alumbrado, calefacción y potencia no ubicada en las unidades de vivienda, debe ser añadida con un factor de demanda de 75%

Area comun Sotanos comercio computadoras comercio

POTENCIA INSTALADA

FACTOR DE DEMANDA

MAXIMA DEMANDA

20950 x 1

20950

100

20950

20950 x 2

41900

65

27235

20950 x 2

41900

40

16760

188050

30

56415

82800

25

20700

5884 6000 300 40000 3750 12000 5000 75000 523534 523.534

75 75 75 75 75 75 75 75

4413 4500 225 30000 2812.5 9000 3750 56250 253010.5 253.0105

10350 x 8

4x1471 1x6000 1x300 1x40000 25x150 25x120x4 25x200 20x150x25


EDIFICIO 2 D1 (80m2) primeros 45m2 siguientes 45m2 o fracción cocina electrica terma horno microondas refrigeradora

Potencia Instalada

10.35 kw D2 (150m2) primeros 45m2 siguientes 45m2 o fracción adicionales 90m2 o fraccion cocina electrica 3 termas microondas refrigeradora secadora

Potencia Instalada

16.95 kw D3 (250M2) primeros 45m2 siguientes 45m2 o fracción adicionales cada 90m2 o fraccion cocina electrica 3 termas microondas refrigeradora secadora

1500 1000 4500 1500 1500 350 10350

1500 1000 1000 6000 1500 1500 450 4000 16950

Potencia Instalada

17.95 kw

1500 1000 2000 6000 1500 1500 450 4000 17950

Factor de Demanda

100 100 100 100 100 100

Maxima Demanda

10.35 kw Factor de Demanda

100 100 100 100 75 100 100 100

Maxima Demanda

18825 kw Factor de Demanda

100 100 100 100 75 100 100 100

Maxima Demanda

19.825 kw

1500 1000 4500 1500 1500 350 10350

1500 1000 1000 6000 3375 1500 450 4000 18825

1500 1000 2000 6000 3375 1500 450 4000 19825

CAPACIDAD DEL EDIFICIO

El 100% de la carga mayor de cualquier unidad de vivienda; más El 65% de la suma de cargas de las 2 unidades de vivienda con cargas iguales o inmediatamente menores a la del subpárrafo (i); más El 40% de la suma de cargas de las 2 unidades de vivienda con cargas iguales o inmediatamente menores que las del subpárrafo (ii); más El 30% de la suma de las cargas de las 15 unidades de vivienda con cargas iguales o inmediatamente menores a las del subpárrafo (iii); más El 25% de la suma de las cargas de las unidades de vivienda restantes. Cualquier carga de alumbrado, calefacción y potencia no ubicada en las unidades de vivienda, debe ser añadida con un factor de demanda de 75%

Area comun Sotanos comercio tvs comercio

POTENCIA INSTALADA

FACTOR DE DEMANDA

MAXIMA DEMANDA

17950 x 1

17950

100

17950

17950 x 2

35900

65

23335

17950 x2

35900

40

14360

228850

30

68655

82800

25

20700

5884 6000 300 40000 3750 15000 3750 100000 576084 576.084

75 75 75 75 75 75 75 75

4413 4500 225 30000 2812.5 11250 2812.5 75000 276013 276.013

10350 x 8

4x1471 1x6000 1x300 1x40000 25x150 25x150x4 25x150 20x200x25


02. TRABAJO: Memoria Descriptiva

ENCARGO Los alumnos aprenden a diseñar los circuitos de alumbrado de un edificio multifamiliar con sótanos. Se elaborará la memoria descriptiva del proyecto incluyendo el cálculo de cuadro de cargas del proyecto y la red unifilar.

EP1 CRITERIOS RIBA CG7

CG11


MEMORIA DESCRIPTIVA


1 CAPÍTULO I: INTRODUCCIÓN Y ANTECEDENTES 1.1

Datos Generales

El presente proyecto se desarrolla por encargo del/de la Señor Don Ramón para el diseño y la construcción de un Edificio Multifamiliar de 5 pisos con un sótano en el emplazamiento señalado. 1.2

Objeto del Proyecto

Se redacta el presente proyecto con el objeto de describir los trabajos necesarios para el diseño y la construcción de la edificación, la cual consistente en un edificio de 16 departamentos con 4 departamentos por piso. Además, se detallará el cálculo eléctrico que se usará para este proyecto, de acuerdo con la normativa vigente y mediante herramientas informáticas. 1.3

Situación y Emplazamiento

El edificio multifamiliar se ubicará en Av. Olguín 565. El terreno a tratar ocupa una superficie de 880 m2, siendo sus dimensiones de 22 m de ancho por 40 m de fondo.

Figura 1 Emplazamiento y localización del terreno.

1


En la siguiente tabla se detallan los parámetros urbanísticos más importantes que se deben de tener en cuenta a la hora de realizar el proyecto. PARÁMETROS NORMATIVOS AL ÁREA DEL LOTE ZONIFICACIÓN

RMD (Residencial de Mediana Denidad)

SECTOR DE ÍNDICE DE USOS

B

USOS PERMISIBLES

Residencial

USOS COMPATIBLES

CL, CV CZ, E1, E2, E3, E4

LOTE NORMATIVO

880 m2

ÁREA LIBRE

11%

ALTURA MÁXIMA

10.2 (a+r)

RETIRO FRONTAL

4.60 m Frente a AV. OLGUÍN

FRENTE GRAFICO DEL LOTE

22 m Frente a AV. OLGUÍN

ESTACIONAMIENTO

44 estacionamientos

Tabla 1 Parámetros urbanísticos del terreno

1.4

Topografía

El lote no presenta desniveles apreciables en el nivel de la calle. 1.5

Accesos

La edificación analizada tendrá un ingreso vehicular por la Av. Manuel Olguín y un ingreso peatonal por la misma avenida. 1.6

Alturas

Respetando los límites dictados por los parámetros urbanísticos, los cuales permiten tener una altura máxima de 10.50 m, el proyecto a tratar constará de 5 pisos con 10.20 m. 1.7

Descripción Funcional por Niveles

Este proyecto constará de 1 sótano y 1 nivele de área común y 4 niveles de vivienda. A continuación, se detallarán las funciones de cada nivel a tratar.

2


1.7.1

Planta 1

La primera planta se ubicará en el nivel +1.70. La planta consta de un espacio designado al área común (gimnasio), 2 servicios higiénicos y 1 recepción. 1.7.2

Planta 2, 3 4 y 5

La segunda, tercera, cuarta y quinta planta se encontrarán en los niveles +3.40, +5.10, +6.80 y +8.50 respectivamente. Estos pisos cuentan con 2 tipologías: 2 departamentos cuentan con 2 dormitorios, 1 sala de estar, comedor, kitchenette, lavandería, 2 servicios higiénicos y 1 cuarto de servicio y los otros 2 departamentos cuentan con 3 dormitorios, 1 sala de estar, comedor, kitchenette, lavandería, 2 servicios higiénicos y 1 cuarto de servicio. 1.7.3

Planta del Semi-Sótano

La planta del semi-sótano se encontrará en el nivel -1.50m. En este nivel se ubicarán los Estacionamientos.

1.8

Cuadro de Superficies

El terreno del proyecto cuenta con un área de 880 m2, considerando un área libre de 99.63 m2, un 11% del proyecto. NIVELES 1. SEMI-SÓTANO 2. PLANTA 1 3. PLANTA 2 4. PLANTA 3 5. PLANTA 4 6. PLANTA 5 TOTAL

m2 CONST. 795.79 813.38 742.36 742.36 742.36 742.36 4578.61

3


1.9

Número de Usuarios de la Edificación (Aforo)

Respetando los límites dictados por el RNE en la Norma A.020 – Artículo 5, se realizó el cálculo del aforo público y de empleados. Ambiente Recepción Gimnacio PLANTA 2 Departamento 1 Departamento 2 Departamento 3 Departamento 4 PLANTA 3 Departamento 1 Departamento 2 Departamento 3 Departamento 4 PLANTA 4 Departamento 1 Departamento 2 Departamento 3 Departamento 4 PLANTA 5 Departamento 1 Departamento 2 Departamento 3 Departamento 4

m2

m2 por persona

Aforo EMPLEADOS

90 130.68

15 4

6 32

TOTAL

2 Dormitorios 2 Dormitorios 3 Dormitorios 3 Dormitorios

3 3 5 5

2 Dormitorios 2 Dormitorios 3 Dormitorios 3 Dormitorios

3 3 5 5

2 Dormitorios 2 Dormitorios 3 Dormitorios 3 Dormitorios

3 3 5 5

2 Dormitorios 2 Dormitorios 3 Dormitorios 3 Dormitorios

3 3 5 5 102 personas

4


2 CAPÍTULO II: NORMATIVA TÉCNICA 2.1

Justificación del cumplimiento de la Normativa Técnica

Para la redacción del presente proyecto se han tenido en cuenta las indicaciones que se dan en las disposiciones que a continuación se citan (lista no exhaustiva) del Reglamento Nacional de Edificaciones del Perú y sus generalidades. 2.2

TITULO I: GENERALIDADES

El Título Primero norma las Generalidades y constituye la base introductoria a las normas contenidas en los Títulos siguientes. 2.2.1

Norma G.010 Consideraciones Básicas

Consideraciones básicas sobre el Reglamento Nacional de Edificaciones. 2.2.2

Norma G.020 Principios Generales

Principios generales: 

De la Seguridad de las Personas;

De la Calidad de Vida;

De la Seguridad Jurídica;

De la Subordinación del Interés Personal al Interés General;

Del Diseño Universal.

2.2.3

Norma G.030 Derechos y Responsabilidades

Los actores del Proceso de la Edificación que intervienen como personas naturales o jurídicas, instituciones y entidades públicas o privadas, son los siguientes: 

El Propietario;

El Promotor Inmobiliario;

Los Profesionales Responsables del Proyecto;

Las Personas Responsables por la Construcción;

Las Municipalidades;

Las Personas Responsables de la Revisión de Proyectos; y

El Ministerio de Vivienda, Construcción y Saneamiento.

5


Sus derechos y responsabilidades están determinados por lo dispuesto en la presente norma, la Ley del Procedimiento Administrativo General, el Código Civil, el Código Penal, y las demás disposiciones que le sean aplicables; así como por lo pactado e el Contrato que acuerda su intervención. 2.2.4

Norma G.040 Definiciones

Definiciones usadas en las Normas del Reglamento Nacional de Edificaciones. 2.2.5

Norma G.050 Seguridad Durante la Construcción

Establece los lineamientos técnicos necesarios para garantizar que las actividades de construcción se desarrollen sin accidentes de trabajo ni causen enfermedades. 2.3

TITULO II: HABILITACIONES URBANAS

El Título Segundo norma las Habilitaciones Urbanas y contiene las normas referidas a los tipos de habilitaciones, los componentes estructurales, las obras de saneamiento y las obras de suministro de energía y comunicaciones. 2.3.1

Norma GH.010 Alcances y Contenidos

Alcances y Contenidos de la normas técnicas contenidas en el Título II Habilitaciones Urbanas. 2.3.2

Norma GH.020 Componentes de Diseño Urbano

Detalla los componentes de diseño de una Habilitación Urbana: los Espacios Públicos y los Terrenos aptos para ser edificados. 2.4

Tipos de Habilitaciones

Serán usadas las normas peruanas vigentes detalladas a continuación: 2.4.1

Norma TH.010 Habilitaciones Residenciales

Constituyen Habilitaciones Residenciales aquellos procesos de habilitación urbana que están destinados predominantemente a la edificación de viviendas y que se realizan sobre terrenos calificados con una Zonificación afín. 2.4.2

Norma TH.020 Habilitaciones Comerciales

Las Habilitaciones para uso Comercial son aquellas destinadas predominantemente a la edificación de locales donde se comercializan bienes y/o servicios y que se realizan sobre terrenos calificados con una Zonificación afín o compatible. 6


2.4.3

Norma TH.030 Habilitaciones para Uso Industrial

Son Habilitaciones para uso Industrial aquellas destinadas predominantemente a la edificación de locales industriales y que se realizan sobre terrenos calificados con una Zonificación afín o compatible. 2.4.4

Norma TH.040 Habilitaciones para Usos Especiales

Constituyen Habilitaciones para Usos Especiales aquellos procesos de habilitación urbana que están destinados a la edificación de locales educativos, religiosos, de salud, institucionales, deportivos, recreacionales y campos feriales. 2.5

Componentes Estructurales

Serán usadas las normas peruanas vigentes detalladas a continuación: 2.5.1

Norma CE.010 Pavimentos Urbanos

Establece los requisitos mínimos para el diseño, construcción, rehabilitación, mantenimiento, rotura y reposición de pavimentos urbanos, desde los puntos de vista de la Mecánica de Suelos y de la Ingeniería de Pavimentos, a fin de asegurar la durabilidad, el uso racional de los recursos y el buen comportamiento de aceras, pistas y estacionamientos de pavimentos urbanos, a lo largo de su vida de servicio. 2.5.2

Norma CE.020 Estabilización de Suelos y Taludes

Establece las consideraciones técnicas mínimas, para el mejoramiento requerido de la resistencia de los suelos y de la estabilidad de taludes, mediante métodos químicos, mecánicos o de modificación topográfica. 2.5.3

Norma CE.030 Obras Especiales y Complementarias

Diseño y Construcción de Ciclovías: Establecer los lineamientos técnicos mínimos para el diseño y construcción de infraestructura para bicicletas.

2.6

Obras de Suministro de Energía y Comunicaciones

Serán usadas las normas peruanas vigentes detalladas a continuación: 2.6.1

Norma EC.010 Redes de distribución de energía eléctrica

Las disposiciones de esta norma son aplicables a todo proceso de electrificación de habilitación de tierras y edificaciones. 7


2.6.2

Norma EC.020 Redes de Alumbrado Público

Las disposiciones de esta norma son aplicables a todo proceso de alumbrado público para habilitaciones urbanas o rurales, así como a su mantenimiento. 2.6.3

Norma EC.030 Subestaciones Eléctricas

Las disposiciones de esta norma son aplicables a todo proceso de electrificación de habilitación de tierras y de edificaciones. 2.6.4

Norma EC.040 Redes de Instalaciones de Comunicaciones

Establece los lineamientos técnicos que deben seguirse para el diseño y la construcción de infraestructura, a fin de dotar de redes de telecomunicaciones, a una habilitación urbana. 2.7

TÍTULO III: EDIFICACIONES

El Título Tercero norma las Edificaciones y comprende las normas referidas a arquitectura, estructuras, instalaciones sanitarias e instalaciones eléctricas y mecánicas. 2.7.1

Norma GE.010 Alcances y Contenidos

Alcances y Contenidos de las normas técnicas contenidas en el Título III Edificaciones, aplicables en el diseño y ejecución de las edificaciones a nivel nacional. 2.7.2

Norma GE.020 Componentes y Características de los Proyectos

Requisitos de información que deberán ser cumplidos por los profesionales responsables por la elaboración de los proyectos. 2.7.3

Norma GE.030 Calidad en la Construcción

Identifica las características de diseño y de ejecución que son críticas para el cumplimiento del nivel requerido para cada una de las etapas del proyecto de construcción y para su vida útil, así como los puntos de control y los criterios de aceptación aplicables a la ejecución de las obras. 2.7.4

Norma GE.040 Uso y Mantenimiento

Identifica las características del uso y del mantenimiento de las edificaciones. 2.8

Arquitectura

Serán usadas las normas peruanas vigentes detalladas a continuación:

8


2.8.1

Norma A.010 Consideraciones generales de Diseño

Establece los criterios y requisitos mínimos de diseño arquitectónico que deberán cumplir las edificaciones. 2.8.2

Norma A.020 Vivienda

Constituyen edificaciones para fines de vivienda aquellas que tienen como uso principal o exclusivo la residencia de las familias, satisfaciendo sus necesidades habitacionales y funcionales de manera adecuada. 2.8.3

Norma A.030 Hospedaje

Aplica sobre las edificaciones destinadas a hospedaje cualquiera sea su naturaleza y régimen de explotación, las cuales son establecimientos que prestan servicio y atención temporal de alojamiento a personas en condiciones de habitabilidad. 2.9

Instalaciones Eléctricas y Mecánicas

Serán usadas las normas peruanas vigentes detalladas a continuación: 2.9.1

Norma EM.010 Instalaciones Eléctricas Interiores

Las instalaciones eléctricas que se efectúan a partir de la acometida hasta los puntos de utilización y se aplica obligatoriamente a todo proyecto. 2.9.2

Norma EM.020 Instalaciones de Comunicaciones

Establece las condiciones que deben cumplir, las redes e instalaciones de comunicaciones en edificaciones que involucran a las telecomunicaciones y a los servicios postales de ser el caso. 2.9.3

Norma EM.030 Instalaciones de Ventilación

Se refiere principalmente a disposiciones para la ventilación mecánica, la cual es desde la simple renovación del aire en un ambiente o conjunto determinado de ambientes sin ningún tratamiento, hasta la renovación del aire y su tratamiento con procesos diversos simples o combinados de limpieza, mezcla, humectación, deshumectación, calentamiento y enfriamiento.

9


2.9.4

Norma EM.040 Instalaciones de Gas

Establece los mínimos requerimientos técnicos que se deben incluir en el diseño y construcción de una edificación en la que se instale redes internas de gas natural y/o redes de media y baja presión de gas licuado de petróleo. 2.9.5

Norma EM.050 Instalaciones de Climatización

Establece las especificaciones generales de construcción para instalaciones de climatización a fin de conseguir que la construcción y la supervisión de obra tengan los elementos suficientes para conocer el sistema y la correcta instalación. 2.9.6

Norma EM.060 Chimeneas y Hogares

Establece los requerimientos para las chimeneas, salidas de humo, ventilaciones, hornos, sus conexiones y transporte de productos de combustión; en resumen, todas aplicaciones que se refieran a actividades que requieran la utilización del calor. 2.9.7

Norma EM.070 Transporte Mecánico

Establece los estándares y consideraciones que se aplican al diseño, los dispositivos de seguridad y mantenimiento de los equipos y materiales de los sistemas de transporte mecánico de pasajeros y objetos en las edificaciones. 2.9.8

Norma EM.080 Instalaciones con Energía Solar

Establece las mínimas condiciones técnicas que se deben incluir en el diseño y construcción de una vivienda en las que se incluya el aprovechamiento de energía solar. 2.9.9

Norma EM.090 Instalaciones con Energía Eólica

Establecer las consideraciones técnicas mínimas que debe cumplir un sistema de energía eólica para una edificación. 2.9.10 Norma EM.100 Instalaciones de Alto Riesgo Establecer los requisitos de seguridad para las instalaciones en los proyectos de edificaciones según las necesidades de las actividades a realizar como manipular materiales inflamables, explosivos; llevar a cabo procesos que producen atmósferas de cuidado, instalar equipos de riesgo.

10


2.9.11 Norma EM.110 Confort Térmico y Lumínico con Eficiencia Energética Establecer zonas del territorio de la República del Perú de acuerdo a criterios bioclimáticos para la construcción, indicando las características de cada zona. Además, establecer lineamientos o parámetros técnicos de diseño para el confort térmico y lumínico con eficiencia energética, para cada zona bioclimática definida.

2.10 Sistema de puesta a tierra El sistema de puesta a tierra de acuerdo al diagrama del Piano IE S1. 2.11 Bases de Cálculo Eléctrico El cálculo de los alimentadores, circuitos derivados y especiales cumple con los requisitos del Código Nacional de Electricidad Utilización y el Reglamento Nacional de Edificaciones. 2.12 Especificaciones y Planos El carácter general y alcances de los trabajos, están ilustrados en los diversos planos de instalaciones y las especificaciones técnicas respectivas. 2.13 Planos Además de esta Memoria Descriptiva, se integra con los planos y las especificaciones técnicas, los cuales tratan de presentar y describir un conjunto de partes esenciales para la apreciación completa y satisfactoria del sistema eléctrico. En los planos se indica el funcionamiento general de todo el sistema eléctrico, disposición de los alimentadores, ubicación de circuitos, salidas, interruptores, etc., así como el detalle de los tableros eléctricos. 2.14 Códigos y Reglamentos Para todo lo no indicado en planos y/o especificaciones se ha cumplido con las prescripciones del Código Nacional de Electricidad Utilización y el Reglamento Nacional de Edificaciones.

11


3 CAPÍTULO III: PLANIMETRÍA

12


13


14


4 CAPÍTULO IV: CUADRO DE CARGAS DEPARTAMENTO DE 130 M2 por los primeros 45m2 1500w por los siguientes 45m2 1000w por cada 90m2 adicionales o fraccion 1000w 1 cocina electrica 1 therma 1 Lavadora 1 horno microondas 1 Refrigeradora TOTAL

POTENCIA INSTALADA (PI)

FACTOR DE DEMANDA %

MAXIMA DEMANDA (MD)

1500 1000 1000 4500 1500 2000 1500 350 13350 13.35 KW

100 100 100 100 100 100 100

1500 1000 1000 4500 1500 2000 1500 350

DEPARTAMENTO DE 130 M2 por los primeros 45m2 1500w por los siguientes 45m2 1000w por cada 90m2 adicionales o fraccion 1000w 1 cocina electrica 1 therma 1 Lavadora 1 horno microondas 1 Refrigeradora TOTAL

POTENCIA INSTALADA (PI)

FACTOR DE DEMANDA %

MAXIMA DEMANDA (MD)

1500 1000 1000 6000 1500 2000 1500 450 14950 14.95 KW

100 100 100 100 75 100 100

1500 1000 1000 6000 1125 2000 1500 450

(i) El 100% de la carga mayor de cualquier unidad de vivienda; más (ii) El 65% de la suma de cargas de las 2 unidades de vivienda con cargas iguales o inmediatamente menores (iii) El 40% de la suma de cargas de las 2 unidades de vivienda con cargas iguales o inmediatamente menores que las del subpárrafo (ii); más (iv) El 30% de la suma de las cargas de las 15 unidadesde vivienda con cargas iguales o inmediatamente menores a las del subpárrafo (iii); más (v) El 25% de la suma de las cargas de las unidades de vivienda restantes. (d) Cualquier carga de alumbrado, no ubicada en las unidades de vivienda, debe ser añadida con un factor de demanda de 75%. Bomba de agua Ascensor Puerta de acceso

100

13350 13.35 KW

100

14575 14.575 KW

POTENCIA INSTALADA (PI)

FACTOR DE DEMANDA %

14950 x 1

14950

100

MAXIMA DEMANDA (MD) 14950

14950 x 2

29900

65

19435

14950 x 2

29900

40

11960

14950 x 3 + 13350 x8

112600

30

33780

0

0

25

0

25 x 311.8 10 x 1128.75

7795 11287.5

75 75 75

5846.25 8465.625 0

1471 4000 300

1471 4000 300 212203.5 212.2035 KW

75 75 75

1103.25 3000 225 98765.125 98.765125 KW

18


5 REFERENCIAS Anexo 06 - Cálculo de Aforo. (s.f.). Obtenido de http://www.cenepred.gob.pe/web/wpcontent/uploads/Itse/Anexos%202017/Anexo_06_Calculo_de_Aforo.pdf Google Maps. (2021). Obtenido de https://www.google.com/maps/place/Universidad+de+Lima/@-12.088618,76.9740535,148m/data=!3m1!1e3!4m5!3m4!1s0x0:0xc55a9050acb093fc!8m2! 3d-12.0847243!4d-76.9710095 (2013). NORMAS LEGALES: SANTIAGO DE SURCO. El Peruano.

19


03. LAB1: Alumbrado

ENCARGO Práctica de laboratorio. Se muestra el armado de la red de alumbrado de una vivienda unifamiliar en base a los planos de arquitectura entregados. Los alumnos toman notas, imágenes y elaboran un informe.

EP1 CRITERIOS RIBA CG1

CG5

CG8

CG10


INFORME 1

LABORATORIO 1 / RED DE ALUMBRADO

En el presente informe se explicará lo aprendido en la clase de laboratorio, en la cual se vio como primer acercamiento al tema de instalaciones eléctricas que herramientas, materiales y cables se utilizan para las instalaciones en viviendas y edificaciones. HERRAMIENTAS BÁSICAS PARA LAS INTALACIONES ELÉCTRICAS Pelacables

Desarmadores

Alicates En punta, universal y pico de loro

En estrella, plano y distintos tamaños.

ACCESORIOS Tablero Eléctrico

Llave Termo magnética Va dentro del tablero eléctrico y sirve de protección a los cables ante sobrecargas y cortocircuitos.

Caja Octogonal Sirven para las iluminarias que sirven para unir conexiones entre los conductores de la instalación y proteger los empalmes.

Tuberías Conduit Tubo de acero galvanizado, se usa en instalaciones ocultas o visibles.

Caja Rectangular Se utiliza para los interruptores sirven para unir conexiones entre los conductores de la instalación y proteger los empalmes.

Tuberías PVC

Se usa en instalaciones eléctricas domesticas por su bajo peso, rápida y fácil colocación.

Llave Diferencial Se coloca para detectar figas a tierra o fallas de aislamiento ya sea por contacto accidental ó por mal funcionamiento de un artefacto.

Caja de Pase Funciona como paso a los cables eléctricos garantizando la derivación y acceso a las redes eléctricas de telefonía, TV y datos.

Tuberías Curveadas Sirven para ayudar al proceso de instalación eléctrica sanitaria.


CABLES ELÉCTRICOS Son conductores de electricidad que se fabrica generalmente en cobre, por la excelente conductividad de este metal, o de aluminio por ser económico.

Encontramos tipos de cables eléctricos dependiendo del color: Cable Verde y Amarillo

Cable Azul

Se utiliza para toma a tierra.

Cable Blanco

Se utiliza como cable neutro

Se utiliza como cables neutrales.

Cable Negro Estos se pueden utilizan como cable de fase, dependiendo de motivos estéticos.

INTERRUPTORES Interruptores Simples

Interruptores Triples Estos cuentan con tres botones.

Estos cuentan con un solo botón.

Interruptores Dobles Estos cuentan con un dos botones.

Interruptores Conmutadores Estos se utilizan para tener la posibilidad de prender o apagar iluminarias desde dos lugares diferentes dentro de la vivienda.

ESQUEMAS c. neutro

octógono c. fase c. retorno

socket Interruptor Individual Simple


c. neutro

empalme c. fase c. retorno

socket

socket

puente Interruptor Doble Simple

c. retorno c. comunes c. fase

octogono c. neutro

socket

Interruptor Simple de Conmutación

Interruptor Doble de Conmutación


METRADO PC2



04. PC2: Alumbrado

ENCARGO Diseñar las redes de alumbrado de una vivienda unifamiliar, considerando interruptores simples, dobles, triples, conmutación simple, conmutación doble, número de cables.

EP1 CRITERIOS RIBA CG1

CG5

CG8

CG9

CG10


INTALACIONES II NOMBRE Alex Vivanco SECCION:

621

PREGUNTA 1: EL DISEÑO DEBE CONTENER COMO MINIMO 1.- EL DISEÑO DE LAS REDES DE ALUMBRADO DE LOS DOS PISOS 2.- COLOQUE EL NUMERO DE CABLES 2.- UN INERRUPTOR DOBLE, 4.- UN INTERRUPTOR TRIPLE, 5.- UN INTERRUPTOR DE CONMUTACION SIMPLE 6.- UN INTERRUPTOR DE CONMUTACION DOBLE 7.- UBIQUE EL POZO A TIERRA 8.- UBIQUE EL TABLERO GENERAL 9.- UBIQUE EL SUBTABLERO 10.- UBIQUE EL MEDIDOR

CTO. SERV.

L

BAÑO SERV.

PATIO DE SERVICIO

S

E

SIMBOLOGIA

S

LAVANDERIA

Y

E

N

DESCRIPCION

D

A ALTURA m.s.p.t. (borde inferior)

CAJAS (mm)

TUBERIA EMPOTRADA EN TECHO O PARED 15mmØ PVC-P MINIMO TUBERIA EMPOTRADA EN PISO 15mmØ PVC-P MINIMO

S

CENTRO DE LUZ

S

BRAQUETE INTERRUPTOR UNIPOLAR 1 GOLPE

S

INTERRUPTOR UNIPOLAR 2 GOLPE

2Sa,b 3Sa,b,c S (3)

2S (3)

CIELO RASO 2.20 1.20 1.20

OCTOGONAL 100x55 OCTOGONAL 100x55 RECTANGULAR 100x55x40 RECTANGULAR 100x55x40

INTERRUPTOR UNIPOLAR 3 GOLPES

1.20

RECTANGULAR 100x55x40

INTERRUPTOR UNIPOLAR DE CONMUTACION

1.20

RECTANGULAR 100x55x40

1.80

ESPECIAL

TABLERO ELECTRICO EMPOTRADO NUMERO DE CABLES Wh

KW

MEDIDOR WATT-HORA POZO DE TOMA A TIERRA

JARDÌN

2S (3)

2S (3)

TERRAZA

2Sa,b

BAÑO DORMITORIO

COMEDOR

COCINA 2S (3)

S (3) S



2S (3)

DORMITORIO

2Sa,b

S S

S

10

9

8

7

6

5

4

3

8

7

6

5

4

2

3

S (3)

S (3)

SALA

11

S

vestidor

12

1

14

13

BAÑO

S

S (3)

16

S (3)

15

S

2S (3)

HALL

3Sa,b,c

2Sa,b



2S (3) S

BAÑO

DORMITORIO

S

S

HALL DE DISTRIBUCIÓN

vestidor



S (3)

2Sa,b

GARAJE S (3)

INGRESO DORMITORIO

S (3)

2

1

KW

PLANTA 1°PISO esc. 1/50

PLANTA 2°PISO esc. 1/50

0.60

ESPECIAL VER DETALLE


05. DISEÑO: Alumbrado

ENCARGO Los alumnos diseñan las redes de alumbrado y diagramas unifilares de un edificio multifamiliar con sótanos. Se elaborará los planos con las redes incluyendo leyenda, especificaciones técnicas y detalles.

EP2 CRITERIOS RIBA CG1

CG5

CG8

CG9

CG10

CG11


1

2

A

.20 .25

A

3

22.00 21.60 21.50

.25

4

.20 .25

.25

.20

A

.20

4

4

4

B

B 9.00

9.00

4

4

4

C

C 7.00

6.00

7.00

7.00

6.00

2S3,4 4

4

4

ESTACIONAMIENTO SEMISOTANO

2.10

7.00

D

3.75

1.00

D

S4

1.31 2.49 3

3

.90 2.18

E

9.00

9.00 3.13

E

40.00

S3

B

3

3

B

2

1.50

.98

F

F

7.00

6.00

6.00

S1,2,3 2

7.00

2

.25

7.00

2

.25

3.45

G

G

5.20

1

1

5.00

1

10.00 .20

H

4.60

4.60

21.60

.20

.20

22.00

A 1 PLANO SEMISOTANO ESC.: 1/100

2

3

1

H


1

2

3

4

A .25

A

22.00

.25

7.00

.25

7.00

.25

7.00

A

.20

.60

1.20 .15 3.50

19

18

S19

S18

B

.60

2.33

21

20

S20

2.18

23

22

S21

S22

2.18

S23

2.43

S24

2.18

S25

2.18

2.40

S26

2.43

2.18

15

3.90

26

25

24

B

.15 .60

2.23

C-3

15

5.00

15

C-4

C

C

.60

ESTACIONAMIENTO PRIMER PISO

6.00

16

.25

3.75

D

2.05

6.00

16

16

.92

.25

4.03

7.00

D

3S15,16,17

.60

.60

.97 3.30

10

3.75

9 8

.97 1.00 17

.60

E

C-2

1.95

1.00 2.77 .15

2.09

S10 2S 11,12 (3)

2S8,9

B

TG

1.78

2.17 4.90

C-1

3.90

E

.15 40.00

3.57

2S5,6

5

11

S

4.50

7 (3)

B

1.88

F

.15

.60

F

S14

14

SH MUJERES

4.80

1.50

11

6.00

6

RECEPCION

6.00

SH HOMBRES

17

13 S13

G

6

.60

.60

1.88

2S 11,12 (3)

4.00

G

1.36

GYM

.15 1.15

12

12

S 7 (3)

.15

7

H

.60

H

17

1.15

1.55

.25

1.55 6.39

Wh

4.60

.20

3.30

11.00

3.85

22.00

3.50

A 1 PLANO PRIMERA PISO ESC.: 1/100

2

3

1


1

2

3

4

A .25

A

22.00

.25

7.00

.25

7.00

.25

7.00

.20

A

.60

1.20

.80

.15

.15

1.45

1.45

.15

.15 .95

B

B

.60

4.55

6

5

4

4

5

6

COMEDOR

COMEDOR

SALA DE ESTAR 2S (3) 5,6

S (3) 4

3.00

5,6 (3) 2S

4 (3) S

SALA DE ESTAR

.15

2S (3) 5,6

S7

S 14

S (3) 4

14 S

S (3) 3

C

1.35

SH8

9 S8

.15

KITCHENET

7 SH

14

14

.15

7S

3 (3) S 7

14

8

S 15

15 S

LAVANDERIA 15

3

DORMITORIO PRINCIPAL S 16

16

16

1

1

10,11 (3) 2S

DORMITORIO 2 3 (3) S

12,13 (3) 2S

1,2 (3) 2S

3.04

12

12 2

2S (3)1

D

.15

12,13 (3) 2S

S (3) 3

2S (3) 1,2

3.04

11

16 S

CUARTO DE SERVICIO

CUARTO DE SERVICIO

2S (3) 12,13

DORMITORIO 2

2S (3) 12,13

2.66

10

LAVANDERIA 15

3

DORMITORIO PRINCIPAL 11

2S (3) 10,11

.60 .15

9S

10,11 (3) 2S

10

.15

C

9

3

2S (3) 10,11

2.66

.75

SH

SH

8S

3

S9

5,6 (3) 2S

4 (3) S

KITCHENET 14

2

1(3) 2S

13

.15 .60

D

13

.60

S 20

3.30

3.30 S 20

18

18

.60

E

B

2S(3) 1,2

3.90

3

2

1

1

COMEDOR

2

3

4.50

SALA DE ESTAR

.60

S3

2S(3) 4,5

S(3) 8

.60 .15

3S

4,5 2S(3)

S6

S7

6S

8 (3)S

7S

7

KITCHENET 5

6

4

4

SH

5

6

7

DORMITORIO 1 2S(3) 4,5

1.64

6.00

1.42

5.50

S 18

S9 9

LAVANDERIA

10

11

11

2.55

10 (3)S

10 (3)S

10

S(3) 16

.60

5.50

CUARTO DE SERVICIO

10

10

8

11 S

S(3) 10

S(3) 10

6.00

1.64

LAVANDERIA

CUARTO DE SERVICIO 8

1.42 18

S 11

10

8

.90

10

8 (3)S

16 (3)S

2S(3) 14,17

.60

14,17 2S(3)

17

17

12

1.98

.15

5.08 18 S

9S 9

2.40

.90

1.33

4,5 2S(3)

18

8

S(3) 8

8

DORMITORIO 1

5.08

12

SH

G

1.98

SH S(3) 12

.15

F

.89

KITCHENET 8

B

COMEDOR

SH

G

E

39.97

SALA DE ESTAR

F

.60 .15

S 19

S 18 2S(3) 1,2

40.00

12 (3)S 14

16

15

16

15

.15

14

DORMITORIO 2

13

H

DORMITORIO 2

DORMITORIO PRINCIPAL

1.87

15

S(3) 13

15

3.56 1.78

.60

DORMITORIO PRINCIPAL

S(3) 15

13 (3)S

2.47

13

3.56 1.78

15 (3)S

H

1.15

1.15

4.60

1.93

4.80

1.77

1.88

1.93

1.88

1.08

4.80

22.00

1 PLANO SEGUNDO PISO ESC.: 1/100

2

3

1


1

2

3

4

A .25

22.00

.25

7.00

.25

7.00

.25

7.00

A

A 3.00

3.00

.15

.15 .95

B

B

.60

4.55

6

5

4

4

5

6

COMEDOR

COMEDOR

SALA DE ESTAR 2S (3) 5,6

S (3) 4

3.00

5,6 (3) 2S

4 (3) S

SALA DE ESTAR

.15

2S (3) 5,6

S7

S 14

S (3) 4

14 S

S (3) 3

C

1.35

SH8

9 S8

.15

KITCHENET

7 SH

14

14

.15

7S

3 (3) S 7

14

SH

8

S 15

15 S

LAVANDERIA 15

3

DORMITORIO PRINCIPAL S 16

16

16

1

1

10,11 (3) 2S

DORMITORIO 2 3 (3) S

12,13 (3) 2S

1,2 (3) 2S

3.04

12

12 2

2S (3)1

D

.15

12,13 (3) 2S

S (3) 3

2S (3) 1,2

3.04

11

16 S

CUARTO DE SERVICIO

CUARTO DE SERVICIO

2S (3) 12,13

DORMITORIO 2

2S (3) 12,13

2.66

10

LAVANDERIA 15

3

DORMITORIO PRINCIPAL 11

2S (3) 10,11

.60 .15

9S

10,11 (3) 2S

10

.15

C

9

3

2S (3) 10,11

2.66

.75

SH 8S

3

S9

5,6 (3) 2S

4 (3) S

KITCHENET 14

2

1(3) 2S

13

.15 .60

D

13

.60

S 20

3.30

3.30 S 20

18

18

.60

E

B

2S(3) 1,2

E

39.97

3.90

3

2

1

1

COMEDOR

F

.60 .15

S 19

S 18 2S(3) 1,2

40.00

2

3

SALA DE ESTAR

SALA DE ESTAR

.60

S3

2S(3) 4,5

S(3) 8

4.50

.60 .15

3S

4,5 2S(3)

S6

S7

B

COMEDOR

6S

8 (3)S

7S

F

.89 SH 8

7

6

5

KITCHENET

KITCHENET 4

4

SH 6

5

7

DORMITORIO 1 2S(3) 4,5

5.08 1.64

6.00

1.42

5.50

S 18

S9 9

LAVANDERIA

G

10

11

2.55

10 (3)S

10 (3)S

10

10

.60

17

12

12

SH

.15

14

12 (3)S

DORMITORIO 2 16

15

DORMITORIO 16 2

15

DORMITORIO PRINCIPAL

1.87

.15

14

DORMITORIO PRINCIPAL 15

S(3) 13

15

3.56 1.78

S(3) 15

13 (3)S

2.47

13

3.56 1.78

15 (3)S

H

1.15

1.15

4.60

1.93

4.80

1.77

1.88

1.93

1.88

1.08

4.80

22.00

A 1 PLANO CUARTO PISO ESC.: 1/100

G

1.98

SH S(3) 12

.60

8 (3)S

14,17 2S(3)

17

13

8

.90

10

16 (3)S

2S(3) 14,17

1.98

H

11

S(3) 16

.60

5.50

CUARTO DE SERVICIO

10

10

8

11 S

S(3) 10

S(3) 10

6.00

1.64

LAVANDERIA

CUARTO DE SERVICIO 8

1.42 18

S 11

.15

5.08 18 S

9S 9

2.40

.90

1.33

4,5 2S(3)

18

8

S(3) 8

8

DORMITORIO 1

2

3

1


1

2

3

4

A .25

22.00

.25

7.00

.25

7.00

.25

7.00

A

A 3.00

3.00

.15

.15 .95

B

B

.60

4.55

6

5

4

4

5

6

COMEDOR

COMEDOR

SALA DE ESTAR 2S (3) 5,6

S (3) 4

3.00

5,6 (3) 2S

4 (3) S

SALA DE ESTAR

.15

C

2S (3) 5,6

S7

1.35

SH

SH8

9

S 14

S (3) 4

14 S

S (3) 3

KITCHENET

7

14

S8

.15

14

.15

7S

3 (3) S 7

14

8

S 15

15 S

LAVANDERIA 15

3

DORMITORIO PRINCIPAL

DORMITORIO PRINCIPAL 11

2S (3) 10,11

S 16

11

16 S

CUARTO DE SERVICIO

CUARTO DE SERVICIO

2S (3) 12,13

DORMITORIO 2

16

16

1

1

10,11 (3) 2S

.15

12,13 (3) 2S

DORMITORIO 2

S (3) 3

2S (3) 1,2

3.04

3 (3) S

12,13 (3) 2S

1,2 (3) 2S

3.04

12

12 2

2S (3)1

D

2.66

10

LAVANDERIA 15

3

2S (3) 12,13

.60 .15

9S

10,11 (3) 2S

10

.15

C

9

3

2S (3) 10,11

2.66

.75

SH

SH

8S

3

S9

5,6 (3) 2S

4 (3) S

KITCHENET 14

2

1(3) 2S

13

.15 .60

D

13

.60

S 20

3.30

3.30 S 20

18

18

.60

E

B

2S(3) 1,2

E

39.97

3.90

3

2

1

1

COMEDOR

F

.60 .15

S 19

S 18 2S(3) 1,2

40.00

2

3

SALA DE ESTAR

SALA DE ESTAR

.60

S3

2S(3) 4,5

S(3) 8

4.50

.60 .15

3S

4,5 2S(3)

S6

S7

B

COMEDOR

6S

8 (3)S

7S

F

.89 SH 8

7

6

5

KITCHENET

KITCHENET 4

4

SH 6

5

7

DORMITORIO 1 2S(3) 4,5

5.08 1.64

6.00

1.42

5.50

S 18

S9 9

LAVANDERIA

G

10

11

2.55

10 (3)S

10 (3)S

10

10

.60

17

12

12

SH

.15

14

12 (3)S

DORMITORIO 2 16

15

DORMITORIO 16 2

15

DORMITORIO PRINCIPAL

1.87

.15

14

DORMITORIO PRINCIPAL 15

S(3) 13

15

3.56 1.78

S(3) 15

13 (3)S

2.47

13

3.56 1.78

15 (3)S

H

1.15

1.15

4.60

1.93

4.80

1.77

1.88

1.93

1.88

1.08

4.80

22.00

A 1 PLANO TERCER PISO ESC.: 1/100

G

1.98

SH S(3) 12

.60

8 (3)S

14,17 2S(3)

17

13

8

.90

10

16 (3)S

2S(3) 14,17

1.98

H

11

S(3) 16

.60

5.50

CUARTO DE SERVICIO

10

10

8

11 S

S(3) 10

S(3) 10

6.00

1.64

LAVANDERIA

CUARTO DE SERVICIO 8

1.42 18

S 11

.15

5.08 18 S

9S 9

2.40

.90

1.33

4,5 2S(3)

18

8

S(3) 8

8

DORMITORIO 1

2

3

1


1

2

3

4

A .25

22.00

.25

7.00

.25

7.00

.25

7.00

A

A 3.00

3.00

.15

.15 .95

B

B

.60

4.55

6

5

4

4

5

6

COMEDOR

COMEDOR

SALA DE ESTAR 2S (3) 5,6

S (3) 4

3.00

5,6 (3) 2S

4 (3) S

SALA DE ESTAR

.15

2S (3) 5,6

S7

S 14

S (3) 4

14 S

S (3) 3

C

1.35

SH8

9 S8

.15

KITCHENET

7 SH

14

14

.15

7S

3 (3) S 7

14

8

S 15

15 S

LAVANDERIA 15

3

DORMITORIO PRINCIPAL S 16

16

16

1

1

10,11 (3) 2S

DORMITORIO 2 3 (3) S

12,13 (3) 2S

1,2 (3) 2S

3.04

12

12 2

2S (3)1

D

.15

12,13 (3) 2S

S (3) 3

2S (3) 1,2

3.04

11

16 S

CUARTO DE SERVICIO

CUARTO DE SERVICIO

2S (3) 12,13

DORMITORIO 2

2S (3) 12,13

2.66

10

LAVANDERIA 15

3

DORMITORIO PRINCIPAL 11

2S (3) 10,11

.60 .15

9S

10,11 (3) 2S

10

.15

C

9

3

2S (3) 10,11

2.66

.75

SH

SH

8S

3

S9

5,6 (3) 2S

4 (3) S

KITCHENET 14

2

1(3) 2S

13

.15 .60

D

13

.60

S 20

3.30

3.30 S 20

18

18

.60

E

B

2S(3) 1,2

E

39.97

3.90

3

2

1

1

COMEDOR

F

.60 .15

S 19

S 18 2S(3) 1,2

40.00

2

3

SALA DE ESTAR

SALA DE ESTAR

.60

S3

2S(3) 4,5

S(3) 8

4.50

.60 .15

3S

4,5 2S(3)

S6

S7

B

COMEDOR

6S

8 (3)S

7S

F

.89 SH 8

7

6

5

KITCHENET

KITCHENET 4

4

SH 6

5

7

DORMITORIO 1 2S(3) 4,5

5.08 1.64

6.00

1.42

5.50

S 18

S9 9

LAVANDERIA

G

10

11

2.55

10 (3)S

10 (3)S

10

10

.60

17

12

12

SH

.15

14

12 (3)S

DORMITORIO 2 16

15

DORMITORIO 16 2

15

DORMITORIO PRINCIPAL

1.87

.15

14

DORMITORIO PRINCIPAL 15

S(3) 13

15

3.56 1.78

S(3) 15

13 (3)S

2.47

13

3.56 1.78

15 (3)S

H

1.15

1.15

4.60

1.93

4.80

1.77

1.88

1.93

1.88

1.08

4.80

22.00

A 1 PLANO QUINTO PISO ESC.: 1/100

G

1.98

SH S(3) 12

.60

8 (3)S

14,17 2S(3)

17

13

8

.90

10

16 (3)S

2S(3) 14,17

1.98

H

11

S(3) 16

.60

5.50

CUARTO DE SERVICIO

10

10

8

11 S

S(3) 10

S(3) 10

6.00

1.64

LAVANDERIA

CUARTO DE SERVICIO 8

1.42 18

S 11

.15

5.08 18 S

9S 9

2.40

.90

1.33

4,5 2S(3)

18

8

S(3) 8

8

DORMITORIO 1

2

3

1


TD-01 - TD-16 (TABLERO DE DISTRIBUCION DE TODAS LAS TIPOLOGÍAS)

(F) : FASE (N) : NEUTRO (T) : TIERRA

A

TAB. EMPOTRADO 220V, 3Ø, 60 HZ

C-1 C-2 C-3

LLEGA DE MEDIDOR

2-1x16mm²THW+1x10mm²(T)-40mm.ØPVC-P

3x50A

C-4 C-5

2x15A 2x20A 3x30A 2x20A 2x20A

2x25A

1x2.5mm²TW(F)+1x2.5mm²TW(N)- 15mmØPVC-P

ALUMBRADO

2x25A

1x4mm²TW(F)+1x4mm²TW(N)+1x4mm²(T)- 20mmØPVC-P

TOMACORRIENTES

3x40A

3x6mm² TW + 1x6mm²(T) - 20mmØPVC-P

COCINA ELECTRICA

2x25A

1x4mm²TW(F)+1x4mm²TW(N)+1x4mm²(T)- 20mmØPVC-P

TERMA

2x25A

1x4mm²TW(F)+1x4mm²TW(N)+1x4mm²(T)- 20mmØPVC-P

INTERCOMUNICADOR

C-6

RESERVA

C-7

RESERVA

Bornera Tierra

Kw/h 1x10mm2 TW 20mmØ FºGº

P.T.

TD - SG (TABLERO DE DISTRIBUCION DE SERVICIOS GENERALES)

(F) : FASE (N) : NEUTRO (T) : TIERRA

A

TAB. EMPOTRADO 220V, 3Ø, 60 HZ

C-1 C-2 C-3

LLEGA DE MEDIDOR

2-1x16mm²THW+1x10mm²(T)-40mm.ØPVC-P

3x50A

C-4 C-5 C-6

Bornera Tierra

Kw/h 1x10mm2 TW 20mmØ FºGº

P.T.

2x15A 2x15A 2x20A 2x20A 2x20A 2x20A

2x25A

1x2.5mm²TW(F)+1x2.5mm²TW(N)- 15mmØPVC-P

ALUMBRADO SOTANO

2x25A

1x2.5mm²TW(F)+1x2.5mm²TW(N)- 15mmØPVC-P

ALUMBRADO ZONAS COMUNES

2x25A

1x4mm²TW(F)+1x4mm²TW(N)+1x4mm²(T)- 20mmØPVC-P

TOMACORRIENTES

2x25A

1x4mm²TW(F)+1x4mm²TW(N)+1x4mm²(T)- 20mmØPVC-P

INTERCOMUNICADOR

2x25A

1x4mm²TW(F)+1x4mm²TW(N)+1x4mm²(T)- 20mmØPVC-P

ELECTROBOMBAS

2x25A

1x4mm²TW(F)+1x4mm²TW(N)+1x4mm²(T)- 20mmØPVC-P

ASCENSOR

C-7

RESERVA

C-8

RESERVA


06. LAB2: Tomacorrientes

ENCARGO Práctica de laboratorio. Se muestra el armado de la red de tomacorrientes de una vivienda unifamiliar en base a los planos de arquitectura entregados. Los alumnos toman notas, imágenes y elaboran un informe.

EP2 CRITERIOS RIBA CG1

CG5

CG8

CG9

CG10


OBJETIVO

Este trabajo tiene el objetivo de permitirnos conocer los elementos y materiales involucrados en el proceso de instalaciones de tomacorrientes y el circuito de comunicaciones, para el desarrollo de un proyecto integral de una vivienda unifamiliar. El reconocer dichos elementos, la forma de representación y diagramas desarrolla una habilidad esencial en el profesional que se busca formar, el poder trabajar en obra con una experiencia empírica de dichos procesos.

1


1. MATERIALES UTILIZADOS - HERRAMIENTAS Pelacables

Desarmadores

Wincha pasa cable En estrella, plano y distintos tamaños.

ACCESORIOS TABLERO DE DISTRIBUCIÓN

LLAVE TERMOMÁGENTICA Va dentro del tablero eléctrico y sirve de protección a los cables ante sobrecargas y cortocircuitos.

En este se ubica la llave termo magnéticas que alimentan a la diferencial.

LLAVE DIREFENCIAL

CAJA RECTANGULAR

Se coloca para detectar figas a tierra o fallas de aislamiento ya sea por contacto accidental o por mal funcionamiento del aparato.

Se utiliza para los interruptores sirven para unir conexiones entre los conductores de la instalación y proteger los empalmes.

CAJA RECTANGULAR Funciona como paso a los cables eléctricos garantizando la derivación y acceso a las redes eléctricas de telefonía, TV y datos.

TUBERÍA PVC

Se usa en instalaciones eléctricas domesticas por su bajo peso, rápida y fácil colocación. .

TUBERÍAS CURVADAS

Sirven para ayudar al . proceso de instalación eléctrica sanitaria.

2


CABLES ELÉCTRICOS Son conductores de electricidad que se fabrica generalmente en cobre, por la excelente conductividad de este metal, o de aluminio por ser económico.

Se utilizan 3 para el circuito de tomacorrientes CABLE VERDE Y AMARILLO Se utiliza para toma a tierra.

del color:

CABLE BLANCO Se utiliza como cables neutrales.

CABLE NEGRO Estos se pueden utilizar como cable de fase, dependiendo de motivos estéticos. .

TOMACORRIENTES Tomacorriente Simple Este solo tiene para enchufar un aparato electrónico. Este tiene para enchufar tres aparatos electrónicos con solo 2 patas.

Tomacorrientes Dobles Este tiene para enchufar dos aparatos electrónicos.

Tomacorriente Triple Este tiene para enchufar tres aparatos electrónicos con 3 patas.

3


Caja de distribución e interruptores. Una caja de distribución es uno de los componentes principales de una instalación eléctrica en el que se protegen cada uno de los disantos circuitos en los que se divide la instalación a través de fusibles, protección magneto térmicas y diferenciales1. Al menos existe un cuadro principal por instalación, como ocurre en la mayoría de las viviendas, y desde este pueden alimentarse uno o más cuadros secundarios, como ocurre normalmente en instalaciones industriales y grandes comercios. En el tablero se tienen los interruptores de cada circuito. Donde cada interruptor recibe energía desde las entradas superiores para que al bajar la llave de un solo circuito no se corte la electricidad de los demás. Luego del interruptos los cables pasan por los diferenciales y luego continúa fuera de la caja para seguir el circuito. En la parte inferior o superior del tablero

de

distribución

se

encuentran un par de borneros de cobre con un puente entre ellos

hecho

con

un

cable

amarillo/verde, el que lleva a tierra,

de

esta

manera

se

distribuye este cable por cada circuito.

Finalmente, todos los circuitos pasan por tubos en el inferior de la caja para hacer su recorrido a través del sistema eléctrico.

1

Son capaces de medir la posible diferencia de corriente de entrada y de retorno en un sistema eléctrico y por eso se llama diferencial. Se trata de dispositivos electromagnéticos cuya función principal es interrumpir inmediatamente la corriente cuando detectan una falla o fuga en el circuito eléctrico.

4


Circuito de Tomacorrientes El circuito de tomacorrientes es uno de los circuitos de mayor facilidad de instalación debido a la presencia de solo dos terminales por cable lo que facilita la camino eléctrico. El circuito de Tomacorrientes tiene origen como todo los circuitos en el Tablero Eléctrico el cual es el encargado de proteger los componentes de mando y control de cualquiera de sus circuitos. De este tablero comienza el circuito a partir de una llave termo magnética. Esta llave termo magnética es alimentada por los cables de fase y neutro lo cuales también salen de la misma para alimentar todo el circuito. No olvidar que también en el tablero se encuentra una bornera de cobre la cual es la portadora del cable de pozo a tierra (verde/amarillo) que va ser el tercer cable que a acompañar al fase y al neutro en el circuito de tomacorrientes. Estos tres cables salen por una tubería en dirección hacia el piso, luego esta hace un doblez de 90 grados y va de forma horizontal por el piso en dirección hacia su destino (tomacorriente). Estos tomacorrientes dependiendo de su uso van a estar ubicados a cierta distancia del piso. En el caso de la cocina los tomacorrientes estarán ubicados por lo menos a 1.20 metros. En el caso que la cocina sea eléctrica no se colocara tomacorrientes pues los cables del circuito se conectaran directamente con la cocina. Llegan los tres cables al tomacorriente (simple) y son conectados a los terminales designados para cada uno. Luego si se desea seguir el circuito, salen del mismo tomacorrientes a través de terminales, los mismos cables (fase, neutro y pozo a tierra). Y el mismo procedimiento se realiza con un tomacorriente doble de mayor complejidad solo que este contara con los dos terminales por cable en cada una de las tomas o enchufes los cuales ser comunicaran por puentes en el mismo tomacorriente.


Circuito de Comunicaciones El circuito de comunicaciones ya sea la instalación de cable tv, telefonía e internet no implica una instalación dependiente de la alimentación eléctrica del lugar, es decir, estas instalaciones no parten del tablero de distribución, parten de el cableado de la compañía contratada para el servicio. A lo largo de los años, el servicio de instalaciones de comunicación ha ido mejorando hasta el punto en que actualmente se necesita solo un cable que proporcione los 3 servicios dentro de un mismo espacio, 1 CABLE FIBRAOPTICA esto facilita la forma de instalación dentro de la vivienda ya que se dejan puntos de salida para dichos cableados, se deja unas tuberías libres que den paso a dichos puntos de salida para poder instalar el cable tv, modem de internet o cable ethernet y/o cable de telefonía. Del cableado externo de la compañía que provee el servicio de comunicaciones a la vivienda entra a una caja de paso la cual esta conectada a una tubería que sube o baja dependiendo de la vivienda; a partir de la caja de paso parte un ramal de tuberías que dan paso a los puntos de acceso en los lugares posibles en los que necesitaremos dichos servicios. *El cable de intercomunicador tiene una instalación diferente; sin embargo, es bastante simple ya que basta con la alimentación eléctrica del tomacorriente más cercano.

6


RECOMENDACIONES  En cuanto al espacio dimensional de los interruptores (entre estos mismos o hacia otros aparatos) debe radicar cada 3.6 mts, lo que implica que nunca debe extenderse un cable eléctrico para un aparato electrónico más de 1.8 mts por prevenciones de seguridad.  Un tomacorriente debe ser resistente a la manipulación en 15A o 20A, dependiendo del amperaje que lleve el cable que da servicio a ese tomacorriente.  Para la instalación de tomacorrientes en servicios higiénicos, estos deben instalarse al menos a 90 cm del borde exterior del lavadero. El tipo de salida que se instalara debe ser interruptores de falla a tierra, por ello no debe haber tomacorrientes boca arriba de las encimeras.  En el caso de las cocinas, los tomacorrientes deben colocarse a una distancia máxima de 1.20 mts entre sí. Es decir, la idea es que ningún punto en el mostrador debe estar a más de 60 cm de una toma de corriente.  Se deben instalar los tomacorrientes de tal forma que el terminal de neutro quede arriba en las instalaciones horizontales.  Los tomacorrientes polarizados con polo a tierra deben tener claramente identificados mediante letras, colores o símbolos los terminales de neutro y tierra y si son trifásicos los terminales, donde se conectan las fases también se deben marcar con letras. En los monofásicos el terminal plano mas corto debe ser el de fase.  No debemos ajustar demasiado los tornillos del terminal potencial cuando se conecte los cables. Si lo haces y escuchas que algo se rompe dentro del tomacorriente, deberás descartarlo y usar otro.  No debemos sobrecargar los tomacorrientes. Si enchufa muchos electrodomésticos en un mismo tomacorriente los cables de la instalación sufren una sobrecarga y pueden provocar cortocircuito.  Los tomacorrientes que no funcionen correctamente pueden indicar la existencia de una condición insegura en ele sistema eléctrico, como se en el caso de las placas exteriores de los tomacorrientes cuando se caliente indicando inseguridad en el sistema eléctrico.

CONCLUSIONES   

Cuando hay una caída de tensión sucede que hay corto circuitos por el exceso de cargas esto se debe a que lo han conectado a la red de luminarias, ya que la red de alumbrado es diferente a la de tomacorrientes. En el área que se van a conectar los montantes se debería una placa de las bandejas metálicas, porque una es para las camarras y otra para los tomacorrientes. En el mercado existe una infinidad de modelos de tomacorrientes. Uno es un modelo universal con toma de tierra que internamente comparten energía y hacia otros puntos. A diferencia de otros que llegan fase y neutro, solo al primero y para alimentar al segundo, se utilizan puentes, que no deben quedar expuestos porque podrían generar un cortocircuito. El responsable de la instalación debe ser cuidadoso en el trato de los cables, de estar todo el tiempo al pendiente de cómo se está desarrollando la instalación, supervisar las conexiones con los empalmes y sobre todo tener gente especializada en el área para la conexión de los empalmes, terminales y los elementos necesarios para su adecuado funcionamiento, pues una falla en la mano de obra puede tener grandes costos. Lo que se rescata de este laboratorio es la importancia que se le tiene que dar al desarrollo de un buen diseño de circuito de tomacorrientes, conociendo todos sus componentes y detalles para que próximamente se utilice este conocimiento en proyectos y supervisión de obras.

7


07. PC3: Tomacorrientes

ENCARGO Diseñar las redes de tomacorrientes y comunicación de una vivienda unifamiliar, considerando los tomacorrientes, salidas de TV, salidas de teléfono, bombas, intercomunicadores.

EP2 CRITERIOS RIBA CG1

CG5

CG8

CG9

CG10


Instalaciones II 2021-0 Evaluación 7 Pregunta 2

Se desea diseñar una instalación de alumbrado para un laboratorio con las siguientes dimensiones: 20 m de ancho por 20 m de largo y 3.5 m de alto. La altura del plano de trabajo es de 0.76 m sobre el suelo. El laboratorio requiere 800 luxes de iluminación. Sus paredes son claras, tiene el techo blanco y piso negro. Se utilizarán luminarias con lámparas que consumen 60w y generan 6,000 lúmenes. Calcular: a) b) c) d) e)

El índice del local K El factor de utilización (Cu) El flujo luminoso total El número de lámparas Dibujar un esquema de su distribución

(1.0 puntos) (1.0 puntos) (1.0 puntos) (1.0 puntos) (1.0 puntos)

Pregunta 3

Si el laboratorio cuenta con el siguiente equipamiento y personal: 05 Tv de 55 pulgadas de 200w cada uno 06 equipos de procesamiento de 400w cada uno 01 equipo de audio de 1000w 20 computadoras de 100w c/u Ocuparán 30 personas El área total de ventanas es 48 m2 El recinto tiene exposición al sol Calcular: a) b) c) d) e)

Calcular el total de BTU por área Calcular el total de BTU por personas Calcular el total de BTU por ventanas Calcular el total de BTU por equipos eléctricos Calcular el total de BTU

(0.5 puntos) (0.5 puntos) (1.0 puntos) (1.0 puntos) (1.0 puntos)


INTALACIONES II NOMBRE ALEX VIVANCO SECCION:

621

PREGUNTA 1: Realice el diseño de las redes de tomacorrientes y comunicación para las plantas del primer y segundo piso de la vivienda. a) Salida de tomacorrientes

(1.0 puntos)

b) Salidas de TV

(0.5 puntos)

c) Salidas de teléfono

(0.5 puntos)

d) Salida de Intercomunicadores

(0.5 puntos)

e) Tablero general

(0.5 puntos)

f) Bomba

(0.5 puntos)

g) Calentadores

(0.5 puntos)

h) Diseño de red de tomacorrientes

(3.0 puntos)

i) Diseño de red de tv / internet

(2.0 puntos)

j) Diseño de red de telefonía

(1.0 puntos)

k) Diseño de red de intercomunicadores

(1.0 puntos)

LEYENDA TPA

T

T

T

T

T

T T

T



TV

T

T

C-2 sube C-3 y C-4

T

T

TE

TV

TV

TE

TI



T

T

T

T

T

PLANTA 1° PISO

T

T  TV

T

T

T

C-3

T TV

T T TV

C-4

TE

C-1

T

T

T

PLANTA 2° PISO

PLANO DE TECHOS


EJERCICIO 2 VALOR DE K K=(20*20)/(2.74*40)=3.649

VALOR DE CU CU=58

FLUJO LUMINOSO Ot= (500*20*20)/(0.58*0.8)=431034.482

NUMERO DE LUMINARIAS NL= 431034.482/6000=71.839 REDONDEAR 72 LUMINARIAS

ESQUEMA


EJERCICIO 3 Procedimiento de Cálculo para Equipos de Aire Acondicionado 400 m2 30 2 m de Ventanas = 48 m2 Equipos electónicos = 21,849.60 Wa�s

Area = Número de Personas =

m2

Area cocina = Exposición del recinto = 2

3. m del área para acondicionar �

2

75 100 150 200 250 300 350 400 500 600 800 900 1000 1250 1500 1750 2000 2250 2500 2750 3000 3250 3500 3750 4000 4500 5000 6000 7000 8000 9000 10000 11000

m

2

7 9 14 19 23 28 33 37 47 56 75 84 93 117 140 163 187 210 233 257 280 303 327 350 373 420 467 560 653 747 840 933 1027

6

BTU´s/Hr 2600 3350 5200 6000 6900 7500 7900 9000 10900 12800 14900 17000 18000 24900 28900 35800 36100 42900 46900 53800 54000 64700 71600 78500 82500 89450 100350 118400 136200 154300 172500 190400 208700

4. Número de Personas Personas BTU´s/Hr 1 2 3 4 5 10 15 20 30 40 50 60 70 80 90 100 120 140 160 180 200 220 240 260 280 300 350 400 450 500 600 700 800

600 1200 1800 2400 3000 6000 9000 12000 18000 24000 30000 36000 42000 48000 54000 60000 72000 84000 96000 108000 120000 132000 144000 156000 168000 180000 210000 240000 270000 300000 360000 420000 480000

2

5. m de Ventanas m

2

1 2 3 4 5 10 15 20 25 30 35 40 45 50 60 70 80 100

BTU´s/Hr 714 1429 2143 2857 3571 7143 10714 14285 17857 21428 25000 28571 32142 35714 42857 50000 57142 71428

6. Equipos Electrónicos Wa�s

1000 2000 3000 4000 5000 7500 10000 12500 15000 17500 20000 25000 30000 40000 50000 70000 80000 100000


6. Equipos Electrónicos BTU´s/Hr 3414 6828 10242 13656 17070 25605 34140 42675 51210 59745 68280 85350 102420 136560 170700 238980 273120 341400

7. Cocinas m2 BTU´s/Hr 10 15 20 25 30 35 40 45 50 60 70 80 90 100 120

4000 6000 8000 10000 12000 14000 16000 18000 20000 24000 28000 32000 36000 40000 48000

8. Exposición del Reciento +10%

-10%

Resumen Descripción BTU´s/Hr 1. Nombre del Área: 2. Ubicación Geográfica: 3. Metros Cuadrados = 88471 4. Personas = 18000 5. Ventanas = 34286 6. Equipo Electrónico = 21849.6 7. Cocinas = Total 1 = 162607 8. Exposición del Recinto =16260.7 Total 2 = 146346


08. DISEÑO: Tomacorrientes

ENCARGO Los alumnos diseñan las redes de tomacorrientes y comunicación de un edificio multifamiliar con sótanos. Se elaborará los planos con las redes incluyendo leyenda, especificaciones técnicas.

EP2 CRITERIOS RIBA CG1

CG5

CG8

CG9

CG10

CG11


PRODUCED BY AN AUTODESK STUDENT VERSION

1

2

A

.20 .25

A

3

.20

22.00 21.60 21.50

.25

4

.20 .25

.25

T

A

.20

T

B

B 9.00

9.00

T

T

C

C 7.00

7.00

7.00

6.00

6.00

ESTACIONAMIENTO SEMISOTANO

2.10

3.75

1.00

D

PRODUCED BY AN AUTODESK STUDENT VERSION

1.31 2.49

.90

T

2.18

E

9.00

9.00 3.13

B

E

40.00

B

T T

1.50 T

.98

F

F

7.00

6.00

6.00

7.00

.25

.25

7.00

3.45

G

G T

5.00

5.20

10.00 .20

H

H LEYENDA

4.60

4.60

DORMA PRUEBA DE AGUA

TPA T T T

TOMACORRIENTE ALTO

1.40

TOMACORRIENTE ALTO

1.80

TOMACORRIENTE

0.45

NUMERO DE CABLES CABLE DE TV

21.60

.20

CABLE DE INTERNET

.20

22.00

CABLE DE INTERCOMUNICADORES

A 1

BOTONERA FUENTE

2

3

1

TV

TE

TI

PLANO SEMISOTANO ESC.: 1/100

SALIDA DE TV SALIDA DE INTERNET SALIDA DE INTERCOMUNICADORES SALIDA DE FUERZA

INTEGRANTES:

WALTER ALCÁZAR DIEGO CAMACHO GUSTAVO CIERRA EVELYN SUAREZ ALEX VIVANCO

UNIVERSIDAD DE LIMA FACULTAD

Ingeniería y Arquitectura

PROYECTO:

Carrera

Arquitectura

PROFESOR(A):

PLANO:

SEMISÓTANO ESCALA:

1/100

EDIFICIO MULTIFAMILIAR CURSO:

LÁMINA:

JOSÉ REYES NIQUE

FECHA:

INSTALACIONES ELÉCTRICAS

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION

7.00

D

E-01

HOJA:

27/02/2021

1 DE 6


1

2

3

4

A .25

A

22.00 7.00

.25

7.00

.25

.25

7.00

A

.20

.60

1.20 .15 3.50 2.40

B

.60

2.33

2.18

2.18

2.43

2.18

2.18

2.43

2.18

C

B

.15 .60

2.23

3.90

5.00

C

.60

T

ESTACIONAMIENTO PRIMER PISO

T

6.00

.25

2.05

.92

.25

4.03

6.00

PRODUCED BY AN AUTODESK STUDENT VERSION

3.75

D

7.00

.60

D

.60

.97 3.30

3.75 .97 1.00

1.00 2.77 .15

.60

E

1.95

TG

2.09

T

1.78

E

.15 40.00

3.57 TI

TE

2.17

B

T

4.90

VT

3.90

4.50

T

B

1.88

F

.15

.60

F SH MUJERES

RECEPCION

T

4.80

1.50

6.00

SH HOMBRES

T

6.00

T

T

T

G

.60

.60

G

1.36

GYM

1.88

.15

4.00

1.15 .15 TI TV

T T

.60

TE

H

VT

H

Wh

TI

1.15

1.55

.25

1.55 6.39

Wh

LEYENDA

4.60

DORMA PRUEBA DE AGUA

TPA T T T

TOMACORRIENTEALTO

1.40

TOMACORRIENTEALTO

1.80

TOMACORRIENTE

0.45

NUMERO DE CABLES

.20

3.30

11.00

3.85

22.00

CABLE DE TV

3.50

CABLE DE INTERNET

CABLE DE INTERCOMUNICADORES

A 1

BOTONERA

2

3

1

FUENTE TV

TE

TI

PLANO PRIMERA PISO ESC.: 1/100

SALIDA DE TV SALIDA DE INTERNET SALIDA DE INTERCOMUNICADORES SALIDA DE FUERZA

INTEGRANTES:

WALTER ALCÁZAR DIEGO CAMACHO GUSTAVO CIERRA EVELYN SUAREZ ALEX VIVANCO

UNIVERSIDAD DE LIMA FACULTAD

Ingeniería y Arquitectura

Carrera

Arquitectura

PROYECTO:

PROFESOR(A):

PLANO:

PRIMER PISO ESCALA:

1/100

EDIFICIO MULTIFAMILIAR CURSO:

LÁMINA:

JOSÉ REYES NIQUE

FECHA:

INSTALACIONES ELÉCTRICAS

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION

E-02

HOJA:

27/02/2021

2 DE 6


1

2

3

4

A .25

A

22.00

.25

7.00

.25

7.00

.25

7.00

.20

.80

.15

.15

1.45

1.45

.15

T

T

.15

T

T

TV

.95

B T

T

SALA DE ESTAR

T

T

COMEDOR

COMEDOR

SALA DE ESTAR

TV

TV TE

T T

1.35

T

T

T TT

SH

KITCHENET

TI

TI

KITCHENET

SH

TT

.75

SH

SH

C-2

C-2

T

T

T

T

TE

T

TE

T T

LAVANDERIA

LAVANDERIA

C-5

T

DORMITORIO PRINCIPAL

T

DORMITORIO 2

C-5

T

.15

T

DORMITORIO PRINCIPAL

.15 C-3

T T

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

3.04

T

DORMITORIO 2

T

3.04

T TV

T

TV

T

T

.15 .60

3.30

3.30

.60

E

.60 .15 T

40.00

T

T

T

3.90

4.50 COMEDOR

TV

T

SALA DE ESTAR

TV

TV

T

KITCHENET

T

SH

T

KITCHENET

C-4

T

DORMITORIO 1

T

T T

C-5

6.00

TV

TV

T T

C-5

LAVANDERIA

6.00

LAVANDERIA

T

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

C-3 TV

TV

T

T

TV

TV

TE

.60

TE

T

G

T

T

T

SH T

.15

T

.15

T

T

DORMITORIO 2

TV

TV

VT

DORMITORIO 2

DORMITORIO PRINCIPAL

T

1.98

SH

TV

DORMITORIO PRINCIPAL

T

T

2.47

T

T

T

.60

H

1.15

1.15

4.60

LEYENDA DORMA PRUEBA DE AGUA

TPA T T T

1.93

1.77

4.80

1.88

1.93

1.88

1.08

4.80

TOMACORRIENTE ALTO

1.40

TOMACORRIENTE ALTO

1.80

TOMACORRIENTE

0.45

NUMERO DE CABLES

22.00

CABLE DE TV CABLE DE INTERNET

CABLE DE INTERCOMUNICADORES

1

2

3

BOTONERA

1

FUENTE TV

PLANO SEGUNDO PISO ESC.: 1/100

TE

TI

SALIDA DE TV SALIDA DE INTERNET SALIDA DE INTERCOMUNICADORES SALIDA DE FUERZA

INTEGRANTES:

WALTER ALCÁZAR DIEGO CAMACHO GUSTAVO CIERRA EVELYN SUAREZ ALEX VIVANCO

UNIVERSIDAD DE LIMA FACULTAD

Ingeniería y Arquitectura

PROYECTO:

Carrera

Arquitectura

PROFESOR(A):

PLANO:

SEGUNDO PISO ESCALA:

1/100

EDIFICIO MULTIFAMILIAR CURSO:

LÁMINA:

JOSÉ REYES NIQUE

FECHA:

INSTALACIONES ELÉCTRICAS

PRODUCED BY AN AUTODESK STUDENT VERSION

H

SH C-2

C-2

T

1.87

F

T

C-4

DORMITORIO 1

.60

.60

T

T

T

T

B

T

T

TV

.60

T

COMEDOR

TE

SALA DE ESTAR

TV

TE

T

1.98

E

39.97 TV

TV

B

D

.60

PRODUCED BY AN AUTODESK STUDENT VERSION

T

D

2.66

TV

T

TV

2.66

C

.60 .15

C-4

C-4

.15

.15

TE

T

.15

C

3.00

TV

TV

G

B

.60

4.55

F

A

.60

1.20

TV

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION

E-03

HOJA:

27/02/2021

3 DE 6


1

2

3

4

A .25

A

22.00 7.00

.25

7.00

.25

.25

7.00

.20

.80

.15

.15

1.45

1.45

.15

T

.15

T

T

.95

TV

T

B T

T

T

T

COMEDOR

SALA DE ESTAR

TV

COMEDOR

SALA DE ESTAR

TV

T

T

T TT

SH

KITCHENET

TI

TI

KITCHENET

SH

TT

.75

SH

SH

C-2

C-2

T

T

T

T

TE

T

TE

T T

T

DORMITORIO PRINCIPAL

LAVANDERIA

T

DORMITORIO 2

C-5

T

.15

T

DORMITORIO PRINCIPAL

.15 C-3

T T

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

3.04

2.66

TV

TV

T

LAVANDERIA C-5

T

DORMITORIO 2

T

3.04

T TV

T

TV

T

T

.15 .60

3.30

.60

E

.60 .15 T

40.00

T

T

T

3.90

4.50 COMEDOR

TV

T

SALA DE ESTAR

TV

TV

KITCHENET

T

SH

T

KITCHENET

C-4

SH T

T

T

T

T

T

C-5

6.00

TV

TV

DORMITORIO 1

C-2

C-2

T

C-5

LAVANDERIA

6.00

LAVANDERIA

T

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

C-3 TV

TV

T

T

TV

TV

TE

.60

TE

T

G

T

T

T

SH T

.15

.15

T

DORMITORIO 2

VT

DORMITORIO 2

TV

TV

TV

DORMITORIO PRINCIPAL

T

1.98

SH

T

T

1.87

F

T

C-4

DORMITORIO 1

.60

.60

T

T

T

DORMITORIO PRINCIPAL

T

T

2.47

T

T

T

.60

H

1.15

1.15

4.60

LEYENDA DORMA PRUEBA DE AGUA

TPA T T T

1.93

4.80

1.77

1.88

1.93

1.88

1.08

4.80

TOMACORRIENTE ALTO

1.40

TOMACORRIENTE ALTO

1.80

TOMACORRIENTE

0.45

NUMERO DE CABLES

22.00

CABLE DE TV CABLE DE INTERNET

CABLE DE INTERCOMUNICADORES

1

2

3

BOTONERA

1

FUENTE TV

PLANO TERCER PISO ESC.: 1/100

TE

TI

SALIDA DE TV SALIDA DE INTERNET SALIDA DE INTERCOMUNICADORES SALIDA DE FUERZA

INTEGRANTES:

WALTER ALCÁZAR DIEGO CAMACHO GUSTAVO CIERRA EVELYN SUAREZ ALEX VIVANCO

UNIVERSIDAD DE LIMA FACULTAD

Ingeniería y Arquitectura

Carrera

Arquitectura

PROYECTO:

PROFESOR(A):

LÁMINA:

JOSÉ REYES NIQUE PLANO:

TERCER PISO ESCALA:

1/100

EDIFICIO MULTIFAMILIAR CURSO:

INSTALACIONES ELÉCTRICAS

FECHA:

E-04

HOJA:

27/02/2021

PRODUCED BY AN AUTODESK STUDENT VERSION

H

VT

T

T

B

T

T

TV

.60

T

COMEDOR

TE

SALA DE ESTAR

TV

TE

T

1.98

E

39.97 TV

TV

B

D

.60

3.30

PRODUCED BY AN AUTODESK STUDENT VERSION

T

D

C

.60 .15

C-4

C-4

.15

.15

TE

TE

T T

1.35

2.66

3.00

TV

TV

T

.15

C

G

B

.60

4.55

F

A

.60

1.20

TV

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION

4 DE 6


PRODUCED BY AN AUTODESK STUDENT VERSION

1

2

3

4

A .25

A

22.00 7.00

.25

7.00

.25

.25

7.00

.20

.80

.15

.15

1.45

1.45

.15

T

.15

T

T

.95

TV

TV

T

B T

T

T

T

COMEDOR

SALA DE ESTAR

TV

COMEDOR

SALA DE ESTAR

TV

T

T

T TT

SH

KITCHENET

TI

TI

KITCHENET

SH

TT

.75

SH

SH

C-2

C-2

T

T

T

T

TE

T

TE

T T

T

DORMITORIO PRINCIPAL

LAVANDERIA

T

DORMITORIO 2

C-5

T

.15

T

DORMITORIO PRINCIPAL

.15 C-3

T T

T

DORMITORIO 2

T

3.04

T TV

T

TV

T

T

3.30

.60

E

T

40.00

T

4.50

TE

COMEDOR

TV

T

VT

SALA DE ESTAR

TV

TV

T

KITCHENET

T

SH

T

KITCHENET

C-4

SH T

T

T

T

T

T

C-5

6.00

TV

TV

DORMITORIO 1

C-2

C-2

T

C-5

LAVANDERIA

6.00

LAVANDERIA

T

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

C-3 TV

TV

T

T

TV

TV

TE

.60

TE

T

G

T

T

T

SH T

.15

T

.15

T

DORMITORIO 2

VT

DORMITORIO 2

TV

TV

TV

DORMITORIO PRINCIPAL

T

1.98

SH

T

1.87

F

T

C-4

DORMITORIO 1

.60

.60

T

T

T

T

B

T

T

TV

.60

T

COMEDOR

TE

SALA DE ESTAR

TV

1.98

E

39.97

3.90 T

DORMITORIO PRINCIPAL

T

T

2.47

T

T

T

.60

H

1.15

1.15

4.60

LEYENDA DORMA PRUEBA DE AGUA

TPA T T T

1.93

4.80

1.77

1.88

1.93

1.88

1.08

4.80

TOMACORRIENTE ALTO

1.40

TOMACORRIENTE ALTO

1.80

TOMACORRIENTE

0.45

NUMERO DE CABLES

22.00

CABLE DE TV CABLE DE INTERNET

CABLE DE INTERCOMUNICADORES

1

2

3

BOTONERA

1

FUENTE TV

PLANO CUARTO PISO ESC.: 1/100

TE

TI

SALIDA DE TV SALIDA DE INTERNET SALIDA DE INTERCOMUNICADORES SALIDA DE FUERZA

INTEGRANTES:

WALTER ALCÁZAR DIEGO CAMACHO GUSTAVO CIERRA EVELYN SUAREZ ALEX VIVANCO

UNIVERSIDAD DE LIMA FACULTAD

Ingeniería y Arquitectura

Carrera

Arquitectura

PROYECTO:

PROFESOR(A):

PLANO:

CUARTO PISO ESCALA:

1/100

EDIFICIO MULTIFAMILIAR CURSO:

LÁMINA:

JOSÉ REYES NIQUE

FECHA:

INSTALACIONES ELÉCTRICAS

PRODUCED BY AN AUTODESK STUDENT VERSION

H

.60 .15

T

T

TV

B

D

.60

3.30

PRODUCED BY AN AUTODESK STUDENT VERSION

T

.15 .60

TV

PRODUCED BY AN AUTODESK STUDENT VERSION

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

3.04

2.66

TV

TV

T

LAVANDERIA C-5

D

C

.60 .15

C-4

C-4

.15

.15

TE

TE

T T

1.35

2.66

3.00

TV

TV

T

.15

C

G

B

.60

4.55

F

A

.60

1.20

E-05

HOJA:

27/02/2021

5 DE 6


1

2

3

4

A .25

A

22.00

.25

7.00

.25

7.00

.25

7.00

.20

.80

.15

.15

1.45

1.45

.15

T

.15

T

T

.95

TV

T

B T

T

T

T

COMEDOR

SALA DE ESTAR

TV

COMEDOR

SALA DE ESTAR

TV

T

T

T TT

SH

KITCHENET

TI

TI

KITCHENET

SH

TT

.75

SH

SH

C-2

C-2

T

T

T

T

TE

T

TE

T T

T

DORMITORIO PRINCIPAL

LAVANDERIA

T

DORMITORIO 2

C-5

T

.15

T

DORMITORIO PRINCIPAL

.15 C-3

T T

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

3.04

T

DORMITORIO 2

T

3.04

T TV

T

TV

T

T

.60

3.30

3.30

.60

.60 .15 T

T

T

T

3.90

4.50 COMEDOR

TV

T

VT

SALA DE ESTAR

TV

TV

T

KITCHENET

T

SH

T

KITCHENET

C-4

SH T

T

T

T

T

T

C-5

6.00

TV

TV

DORMITORIO 1

C-2

C-2

T

C-5

LAVANDERIA

6.00

LAVANDERIA

T

T

CUARTO DE SERVICIO

CUARTO DE SERVICIO C-3

C-3 TV

TV

T

T

TV

TV

TE

.60

TE

T

G

T

T

T

SH T

.15

.15

T

DORMITORIO 2

VT

DORMITORIO 2

TV

TV

TV

DORMITORIO PRINCIPAL

T

1.98

SH

T

T

1.87

F

T

C-4

DORMITORIO 1

.60

.60

T

T

T

T

B

T

T

TV

.60

T

COMEDOR

TE

SALA DE ESTAR

TV

TE

T

1.98

E

39.97 TV

TV

B

D

.15 .60

40.00

PRODUCED BY AN AUTODESK STUDENT VERSION

T

E

DORMITORIO PRINCIPAL

T

T

2.47

T

T

T

.60

H

1.15

1.15

4.60

LEYENDA DORMA PRUEBA DE AGUA

TPA T T T

1.93

1.77

4.80

1.88

1.93

1.88

1.08

4.80

TOMACORRIENTE ALTO

1.40

TOMACORRIENTE ALTO

1.80

TOMACORRIENTE

0.45

NUMERO DE CABLES

22.00

CABLE DE TV CABLE DE INTERNET

CABLE DE INTERCOMUNICADORES

1

2

3

BOTONERA

1

FUENTE TV

PLANO QUINTO PISO ESC.: 1/100

TE

TI

SALIDA DE TV SALIDA DE INTERNET SALIDA DE INTERCOMUNICADORES SALIDA DE FUERZA

INTEGRANTES:

WALTER ALCÁZAR DIEGO CAMACHO GUSTAVO CIERRA EVELYN SUAREZ ALEX VIVANCO

UNIVERSIDAD DE LIMA FACULTAD

Ingeniería y Arquitectura

Carrera

Arquitectura

PROYECTO:

PROFESOR(A):

PLANO:

QUINTO PISO ESCALA:

1/100

EDIFICIO MULTIFAMILIAR CURSO:

LÁMINA:

JOSÉ REYES NIQUE

FECHA:

INSTALACIONES ELÉCTRICAS

PRODUCED BY AN AUTODESK STUDENT VERSION

H

2.66

TV

TV

T

LAVANDERIA C-5

D

C

.60 .15

C-4

C-4

.15

.15

TE

TE

T T

1.35

2.66

3.00

TV

TV

T

.15

C

G

B

.60

4.55

F

A

.60

1.20

TV

PRODUCED BY AN AUTODESK STUDENT VERSION

PRODUCED BY AN AUTODESK STUDENT VERSION

E-06

HOJA:

27/02/2021

6 DE 6




INFORMACION DEL CURSO I.SUMILLA Instalaciones 2 es una asignatura de carácter teórico práctico obligatoria destinada a desarrollar la capacidad de definir, desarrollar, representar, coordinar, y supervisar los sistemas de instalaciones eléctricas y mecánicas de un proyecto de edificación según la normativa vigente, así como desarrollar la capacidad de trabajo en equipo con compromiso ético y de calidad.

II. OBJETIVO GENERAL Desarrollar la capacidad de definir, desarrollar, representar, coordinar y supervisar las instalaciones electromecánicas de un proyecto de edificación, tomando en cuenta los estándares de calidad, para poder ejercer el rol de coordinador principal de los proyectos, así como tomar las consideraciones necesarias para su correcta aplicación durante el proceso de diseño arquitectónico optimizando el funcionamiento y seguridad de la edificación y de sus usuarios.

III. OBJETIVOS ESPECIFICOS 1. Comprender los conceptos básicos de instalaciones eléctricas y mecánicas para su óptima aplicación, de manera integral en el desarrollo de un proyecto arquitectónico, así como su compatibilización con otras especialidades a partir del análisis de casos prácticos, modelos a escala y aplicándolo en el diseño de proyectos de baja dificultad. 2. Comprender, y evaluar documentos técnicos de proyectos electromecánicos de edificaciones mediante representación gráfica técnica de planos y memorias descriptivas de diversos proyectos que permitan una adecuada, supervisión y control de calidad en obra. 3. Desarrollar la capacidad de trabajo en equipo, así como una actitud crítica, mediante la ejecución de trabajos grupales de planos y maquetas de instalaciones eléctricas, complementadas por una reflexión crítica en la elaboración de un portafolio, demostrando una adecuada coordinación, actitud reflexiva, crítica y compromiso ético.


CV ALEX VIVANCO - 20161559 @alex_vivanco.arq 20161559@aloe.ulima.edu.pe 937533193


ALEX VIVANCO VIVANCO ALEX ESTUDIANTE DE ARQUITECTURA CÓDIGO :20161559

PERFIL PERSONAL

PERFIL ACADEMICO

Soy un estudiante de 24 23 años de la Universidad de Lima de la carrera de Arquitectura. Tengo conocimientos intermedios de programas de diseño.Tengo facilidad para trabajar en equipo, tomar buenas decisiones bajo presión y tomar la labor de líder según las circunstancias dadas. No tengo inconveniente con expresarme en público, lo que facilita exponer mis ideas a los demás. Estoy en busca de adquirir nuevos conocimientos y experiencias que puedan nutrir mi desarrollo profesional.

2003 - 2008 Cooperativa San Felipe

IDIOMAS

Español: Nativo Ingles: Avanzado CONTACTAME

Celular: 937533193 20161559@aloe.ulima.edu.pe Calle Y Mz D lt 20, Urbanización Santa Rosa, Santiago de Surco, Lima, Perú IG: @alex_vivanco.arq

HABILIDADES

AUTOCAD LUMION REVIT ADOBE ILLUSTRATOR ADOBE PHOTOSHOP CC MICROSOFT OFFICE SKETCHUP

LIMA – PERÚ INSTITUCIÓN EDUCATIVA (PRIMARIA) 2009 – 2013 Cooperativa San Felipe LIMA – PERÚ INSTITUCIÓN EDUCATIVA (SECUNDARIA) 2021 2020 - Cursando Arquitectura

LIMA – PERÚ UNIVERSIDAD DE LIMA (7MO CICLO)


621

Profesores: JOSE LUIS REYES ÑIQUE Alumno: ALEX MIGUEL VIVANCO DAMIAN - 20161559


Turn static files into dynamic content formats.

Create a flipbook
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.