CLIMATE RESPONSIVE ARCHITECTURE INTEGRATING CLIMATIC CONSIDERATIONS AS AN PART OF PLANNING AND BUILD

Page 32

Climatic responsive architecture: Integrating climatic considerations

12

as an part of planning and building design

Figure 2.4 - Wind catchers (Source - Climate Responsive architecture: A design handbook foe energy efficient building)

9) Building orientation •

Climatic Implications The quantity of radiation a structure gets is determined by its direction. The quantity of

natural ventilation available is affected by the direction in relation to air patterns. 10) Surface area to volume ratio •

Climatic Implications When it comes to calculating heat loss and gain, the surface area to volume (S/V) ratio is

crucial. •

Building Design The primary problem in warm-humid regions is the creation of airy rooms. A decreased S/V

ratio may or may not be the consequence. In addition, the construction materials should not retain heat. 11) Roof form KARTIKEY BHATT 17EAHAR012

2021-22 SOA, AGI


Turn static files into dynamic content formats.

Create a flipbook

Articles inside

Figure 3.46 - Main entrance of the wada

12min
pages 91-112

Figure 3.45 - Section of Wada house

0
page 90

Figure 3.43 - Hubli, Karnataka

1min
pages 87-88

Figure 3.28 - Initial design of the hamlet

0
page 81

Figure 3.18 - All Chettinadu residences have a rainwater collection system

1min
page 72

Figure 3.19 - The door jamb with stone edging

1min
page 73

Figure 3.17 - Flooring and ceiling

0
page 71

Figure 3.27 - Nalanchira, Trivandrum, Kerala, hamlet map

1min
pages 79-80

Figure 3.16 - Streets & arrangement of chettinadu residence

2min
pages 69-70

Figure 3.15 - Typical view of chettinadu residence

0
page 68

Figure 3.14 - Plan of conventional chettinadu residence

1min
pages 66-67

Figure 3.6 - Shaded windows with roof Projections

1min
page 58

Figure 3.2 - Typical rural houses, Figure 3.3 - Typical dwelling

1min
page 55

Figure 2.12 - Depicting some aspects of wind flow in and around courtyards

3min
pages 46-48

Figure 3.1 - Map of Pippara Village with grid iron street pattern

2min
pages 53-54

Figure 2.10 - Single sided ventilation

0
page 44

Figure 2.11 - Cross ventilation

1min
page 45

afternoon sun rays

0
page 42

Figure 2.9 - Wind pressure induced and temperature induced ventilation

0
page 43

Figure 2.7 - In a warm and humid climate, window building processes are different Figure 2.8 - In a humid climate, shading (Chajja) and shutters on the veranda prevent

1min
page 41

2.2.3 Settlement pattern and site planning

1min
page 38

2.2.4 Envelope design

1min
page 39

Figure 2.2 - Air speed are greatest on the crest

0
page 28

Figure 2.3 - Wide east-west streets maximize the scope for south winter sun

3min
pages 29-31

Figure 2.1 - Map of India indicating the 5 climatic zones

0
page 26

chimneys

1min
page 40

Figure 2.4 - Wind catchers

0
page 32
Issuu converts static files into: digital portfolios, online yearbooks, online catalogs, digital photo albums and more. Sign up and create your flipbook.