Chapter 3
46
3.3
Test cases
A 2 × 2 array of high-rise buildings placed in close proximity is studied. The four buildings are identical with length (L) and breadth (B) equal to 20 m and height (H) equal to 90 m. The street passage width (w) between the buildings is 3 m. Details of the building corner modifications for the different test cases are given in Table 3.3. Note that the building corner modifications are applied to all the edges of the facades and roofs of the buildings. Fig. 3.4 shows the different shapes of the building corner modifications: (a) sharp, (b) chamfered, and (c) rounded. Note that the values are normalized with the building length, B. The building with sharp edges is selected as the reference case.
Figure 3.4. Schematic of the buildings with different corner shapes: (a) sharp, (b) chamfered and (c) rounded. Table 3.3. Details of the test cases. Corner modification
Case ID
Building length, B
Chamfer length, l
Corner radius, r
Ref. case
20 m
0
0
Sharp corner
Chamfered corner
Case C1 Case C2 Case C3
0.05B 20 m
Case C4 Rounded corner
0.10B 0.15B 0.20B
Case R1 Case R2 Case R3 Case R4
-
0.05B 20 m
-
0.10B 0.15B 0.20B