Electronic Cam Module
Installation precautions for the TSX CCY 1128 Installation In order to guarantee good working order, it is necessary to take certain precautions during its installation and removal, when plugging and unplugging the connectors on the front panel of the module, and when adjusting its fixing screws and the SUB D 15-pin connector. Installing and removing the module The module can be installed or removed without cutting the supply to the rack. The design of the module allows this action to be carried out with the power on in order to ensure the availability of the device. Plugging and unplugging the connectors on the front panel of the module It is not recommended that you plug in or unplug the connectors located at the front panel of the module when the sensor/pre-sensor supply is switched on. Reasons:
the encoders will not tolerate a simultaneous start-up or outage of the signals and supplies. The track outputs can become damaged if they are in state 1 and connected to an inductive supply
Adjusting the screws and locking the HE10 connectors in place In order to ensure good electrical contact between the devices and by doing so create effective resistance to electrostatic and electromagnetic interference:
266
the fixing screws on the module and the SUB D 15-pin connector must be correctly screwed in. tightening on the module’s fixing screw: 2.0 N.m tightening on the SUB D 15-pin connector’s fixing screw: 0.5 N.m
The HE10 connectors must be correctly locked.
33002439 10/2019