Electronic Cam Module
General wiring instructions Introduction In order to guarantee that the automatism operates correctly, it is necessary to respect some basic rules. Section of wires used Must be of sufficient size to avoid on-line voltage falls and overheating. Cable path. The encoder connector cables, the other sensors and the pre-actuators must be kept away from any source of radiation resulting from high-power electric circuit switches and which could cause malfunctions. Encoder signal connector cables The module/encoder connector cables must adhere to the following rules:
They must be shielded using a high quality shielding, they must only carry related signals to the encoder, the cable shielding must be linked to the protective ground connection both at the module and the encoder, the grounding must be continuous throughout the connection.
33002439 10/2019
267