Note the following with regard to defaults in the Submaster List display: • • • •
Pile-on is the default type for a newly defined submaster. Bump status does not display unless changed from the default, which is “enabled.” Dwell time defaults to “manual.” Rate does not display unless changed from the default, which is 100.
Navigation and Feedback - Submaster List Select a submaster
7
8
9
4
5
6
1
2
3
[S]
X
Select a field
± X
X
X X
White row
selected submaster
Yellow field
selected field
Editing submasters Changes made to a submaster in the Submaster List are immediately recorded. Edit in the Submaster List as follows.11 Keystrokes:
Actions:
1. Press [Blind].
Selects Blind display
2. Press[Sub] [S2], Sub List.
Displays Submaster List Select submaster number(s)
3. Press [1][3] [Enter].
Selects submaster 13. Prompt reads: Select bump status and press ENTER (1=enabled, 2=disabled, 3=solo)
4. Press [2] [Enter].
Disables bump status for the submaster and prints a “D” in the column. Prompt reads: Enter upfade time
5. Press [5] [Enter].
Specifies 5 second upfade time Prompt reads: Enter dwell time (For hold or manual operation, press CLEAR until desired setting appears)
6. Press [1][5] [Enter].
Specifies 15 seconds dwell time Prompt reads: Enter downfade time
11.
174
Alternatively, you may press [Type] or [Time] keys to reach the field you want. Chapter 14 Lists and spreadsheets